已阅读5页,还剩10页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
Development of polymer-based sensors for integration into a wireless data acquisition system suitable for monitoring environmental and physiological processes Biomolecular Engineering Volume 23, Issue 5, October 2006, Pages 253-257 AbstractIn this work, the pressure sensing properties of polyethylene (PE) and polyvinylidene fluoride (PVDF) polymer films were evaluated by integrating them with a wireless data acquisition system. Each device was connected to an integrated interface circuit, which includes a capacitance to frequency converter (C/F) and an internal voltage regulator to suppress supply voltage fluctuations on the transponder side. The system was tested under hydrostatic pressures ranging from 0 to 17kPa. Results show PE to be the more sensitive to pressure changes, indicating that it is useful for the accurate measurement of pressure over a small range. On the other hand PVDF devices could be used for measurement over a wider range and should be considered due to the low hysteresis and good repeatability displayed during testing. It is thought that this arrangement could form the basis of a cost-effective wireless monitoring system for the evaluation of environmental or physiological processes.Keywords: Pressure; Thick film; Polymers; Sensor; Wireless1. IntroductionIn many professions and industries, the ability to make measurements in difficult to reach or dangerous environments without risking the health of an individual is now a necessity. A way of wirelessly transmitting data from the sensor, which is at the point of interest, to a remote receiver is required. Using this approach, sensors can be implanted in a difficult to reach or harsh environment and left there for a period of time. Sensors designed to measure any number of parameters including pressure, conductivity and pH could be used (Barrie, 1992, Astaras, 2002and Flick and Orglmeister, 2000). Data transfer is typically achieved using radio frequencies to send information to a receiver, which is remote from the area of interest.Apart from industrial and environmental applications, these acquisition systems could revolutionise the healthcare system in a number of areas. They could find applications in the treatment of patients which have experienced extreme traumas by monitoring critical parameters such as intra-cranial pressure (Flick and Orglmeister, 2000 B.B. Flick and R. Orglmeister, A portable microsystem-based telemetric pressure and temperature measurement unit, IEEE T. Bio-Med. Eng. 47 (2000), pp. 1216. Full Text via CrossRef | View Record in Scopus | Cited By in Scopus (15)Flick and Orglmeister, 2000). However, in a more routine setting they could also be used to make long term measurements of biological fluid pressure for clinical studies in several areas, such as cardiology, pulmonology and gastroenterology (Yang et al., 2003). In the future, it may even be possible to monitor patients while they reside in their home or continue to work (Budinger, 2003).With these applications in mind, a wireless data acquisition system, including a capacitance to frequency converter (C/F) and an internal voltage regulator to provide a stable operation has been developed. The circuitry was developed to minimise power consumption, as power will not be randomly available in the test environment. The system was developed specifically for the measurement of pressure. Two capacitive structures were formed using polyethylene (PE) and polyvinylidene fluoride (PVDF) for the sensing layer. These materials were chosen for their biocompatible and mechanical properties. Capacitive structures are preferred as they lead to lower power consumption and higher sensitivity than their piezoelectric counterparts (Puers, 1993).PVDF is a low-density semi-crystalline material, consisting of long repeating chains of CF2CH2 molecules. The crystalline region consists of a number of polymorphs, of which the - and -phase are most common. The -phase is piezoelectric and has many advantages including its mechanical strength, wide dynamic range, flexibility and ease of fabrication (Payne and Chen, 1990). Poled PVDF films have been employed in the development of devices, which can be used in a wide range of applications, for example, providing robots with tactile sensors and the measurement of explosive forces (Payne et al., 1990 and Bauer, 1999).In a medical context, poled PVDF films have been popular in the development of plantar pressure-measurement systems, where their flexibility and the ease with which electrode patterns can be attached has been a particular advantage (Lee and Sung, 1999). Micromachined devices using PVDF as a flexible element in the system have also been developed for use in an endoscopic grasper because of its high force sensitivity, large dynamic range and good linearity (Dargahi et al., 1998).Polyethylene is a cost effective and versatile semi-crystalline polymer consisting of repeating CH2CH2 units. The most common forms are low-density polyethylene (LDPE) and high-density polyethylene (HDPE), where the density is related to the degree of chain branching. It is a material which is useful in pressure-sensing applications and has been popular for use in the development of flexible electronics (Harsanyi, 1995 and Domenech et al., 2005). PE is particularly popular in the fabrication of polymer/carbon-black composites for pressure measurement (Zheng et al., 1999 and Xu et al., 2005). Furthermore, polyethylene terephtalate (PET) has been identified as an electret material with possible dynamic pressure sensing applications (Paajanen et al., 2000).In this work, both PE and PVDF films were formed into a sandwich capacitor, which was then subjected to changing hydrostatic pressures. The films deformed under pressure and the resulting change in capacitance was transmitted wirelessly through the liquid to an external receiver, which converts the signal to a corresponding voltage.2. Experimental procedureThe sensing layers were in the form of films with thickness of approximately 100m. The PVDF film has a dominant -phase and was purchased from Precision Acoustics Ltd. The LDPE film was supplied from Goodfellow Cambridge Ltd. The Youngs modulus of each material is an indication of how likely the material is to deform under applied pressure and is quoted to be 8.3GPa and 0.10.3GPa for PVDF and PE, respectively.To form the capacitors, DuPont 4929 silver paste was deposited using a DEK RS 1202 automatic screen-printer to form electrodes measuring 15mm10mm. The sensor structure is shown in Fig. 1. This approach was used as difficulties in depositing other electrode materials on PVDF have been recorded (Payne and Chen, 1990). After deposition, the electrodes were dried in air and cured at 100C for 30min. The electrical properties of each device were measured, from 1Hz to 1MHz, using a Solatron S1 1260 Impedance Gain/Phase Analyser.Full-size image (12K)Fig. 1.Structure of the PVDF and PE capacitor.View Within ArticleTo evaluate the performance of each material under pressure, capacitors were individually connected to the interface and transmitter circuit. The sensor was protected using a thin, flexible waterproof membrane. The circuit was contained in a weatherproof housing. This was a rigid structure of dimensions 5459mm2 and was necessary to protect the electronics from the liquid environment. To connect the sensor to the interface an opening was drilled into the housing and the connections were made waterproof.The change in capacitance with increasing depth in a liquid environment was then recorded. The pressure in this case ranged from 0 to 17kPa. The change in capacitance was converted to a frequency, which was wirelessly transmitted to an external receiver. The transmitter and receiver are battery powered. A comparison of the power requirements, this circuit (marked with an asterisk) is compared to other standard interface circuits is shown in Table 1. A block diagram of the transmitter and receiver system can be seen in Fig. 2.Table 1. Power consumption for sensor interface circuitsInterface Current consumption Supply voltage (V) (minimum) Universal capacitive readout IC MS33102.96.0mA5AC bridge210mANoneAnderson loop13mA3C-F-V (using F-V converter) LM 290758mA3C-F-V (using F-V converter) TC94001.56mA10C-F-V (using PLL)*500A2.3Full-size tableView Within ArticleFull-size image (15K)Fig. 2.Block diagram of the interface, transmitter and receiver system used to make measurements under hydrostatic pressure.View Within ArticleThe main element of the sensor interface circuit is an integrated capacitance to frequency converter, which is used to link the sensor to the telemetry subsystem. An external voltage regulator is used to improve the stability of the output frequency and RF transmission. A CMOS dual timer (TLC 556) was selected to implement the C/F conversion in astable mode. The output frequency is given in Eq. (1).where fout is the output frequency, Cx is the sensor capacitance, R1 and R2 are the timer frequency set-up resistors. A frequency shift-keying (FSK) transmitter of 160kbps has been selected to send the signal coming from the CMOS oscillator. At the receiver side, the received tones are converted to voltage levels using phase locked loop (PLL) unit. This IC is a micro-power device since it typically draws 20A. The relationship between the frequency (f) and the voltage (V) has been measured to bef=V13.1kHz/V (2)The value of 13.1kHz/V was found by measuring the slope of the change in frequency with voltage for the voltage-controlled oscillator as shown in Fig. 3. It should be noted that while the PLL unit reduces power supply, it creates a non-linear output signal. Therefore the sensor response will appear to be non-linear. Full-size image (10K)Fig. 3.Measured F/V characteristics of the VCO.View Within ArticleFinally, a Lloyd Instruments LR50k was used to evaluate the sensitivity of the PVDF material over a wider pressure range. The LR50k is commonly used to place materials under tension or compression. In this work, it was used in compression mode, increasing the load on the capacitor over time. The change in sensor output was measured using a HP 4192A LF Impedance Analyser at a frequency of 100kHz. The capacitor was repeatedly tested in the range 0560kPa.3. Results and discussionWhen parallel plate capacitors, such as those formed in this study, are placed under pressure, the thickness of the sensing layer changes, resulting in an alteration of the distance, d, between the electrodes or plates. When the pressure is applied uniformly, there is a correspondingly uniform change in d, which leads to a change in the overall capacitance, according to Eq. (3)(3)where, C is the capacitance, r, is the relative permittivity of the dielectric, o, is the permittivity of free space and A is the area of the capacitor plates. The capacitance was found to be 40pF and 140pF for the PE and PVDF sensors, respectively. The relative permittivity was measured to be 3.45 for PE and 9.27 for PVDF at a frequency of 1MHz. The capacitance of both materials showed a high stability over a wide range of frequencies, as shown in Fig. 4, making them well suited for integration into the wireless data acquisition system. Previous work on thick film capacitors using a PZT and PVDF dielectric layer have shown that device sensitivity is affected by operating frequency (Arshak et al., 2000). The differences are attributed to changes in dissipation factor. The PE sensor showed a stable response, however there is some variation the capacitance of the PVDF sensor at higher frequencies. Therefore, operating frequency could be used to optimize the sensor response. Full-size image (15K)Fig. 4.Variation of capacitance with frequency for PE and PVDF devices.View Within ArticleFig. 5 shows the response of the PE and PVDF sensors to pressure in the range 017kPa. It was observed that PE shows a higher sensitivity to pressure changes than the PVDF film. The change in voltage is related to the capacitance change, which is a direct result of deformation of the dielectric layer under pressure. For the PE sensor, the voltage changes by 20mV over the entire range. For the PVDF sensor the change is 5mV. The relationship between capacitance and voltage is shown in Eqs. (1) and (2). Therefore, it can be seen from the results that PE sensors show the highest sensitivity, and are well suited to pressure measurement over the range tested. On the other hand PVDF devices may be more useful for measurements over larger ranges. For example, shock sensors based on PVDF are used to measure impact pressures up to 12GPa (Bauer, 1999).Full-size image (10K)Fig. 5.Change in voltage with pressure in the range 017kPa for the PE and PVDF sensors.View Within ArticleIn order to investigate the behaviour of the PVDF over a large pressure range, it was tested using an LR50k and the results are shown in Fig. 6. It can be seen that the material showed a high sensitivity, particularly for pressures up to 100kPa. It is thought that the dissimilarity in Youngs modulus can explain their different behaviour under pressure. PVDF is a tougher, more resilient material that PE and so it requires higher pressures, to achieve a measurable change in capacitance. Alternatively, PE will deform more easily, resulting in larger changes in capacitance over a reduced pressure range.Full-size image (7K)Fig. 6.Relative change in capacitance for PVDF sensors, tested using a Lloyd Instruments LR50k.View Within ArticleThe maximum difference between loading and unloading cycles was measured and expressed as a percentage of the full-scale deviation in order to calculate the hysteresis. Values ranging from 6 to 30% have previously been calculated for polymer thick film devices (Arshak et al., 1995 and Arshak et al., 2000). In this work, the hysteresis was calculated to be 5% and 6% for the PE and PVDF sensors, respectively, as shown in Fig. 7. This corresponds well with the values quoted above.Full-size image (18K)Fig. 7.Hysteresis of (a) the PE sensor and (b) the PVDF sensor as measured for one loading and unloading cycle.View Within ArticleEach device was also subjected to repeated cycling, in order to establish its repeatability (the maximum difference between output readings as determined by two calibrating cycles). Five cycles are shown for PE in Fig. 8(a) and PVDF in Fig. 8 (b). The repeatability was calculated to be 10% and 6% for PE and PVDF, respectively. This can be attributed to movement of the polymer chains while they are under pressure (Arshak et al., 1995). The more rigid nature of the PVDF can explain the lower percentage repeatability, as it does not suffer the same degree of slippage.Full-size image (26K)Fig. 8.Repeatability of (a) the PE sensor and (b) the PVDF sensor as measured for five loading cycles.View Within ArticleFrom the results shown above, it can be seen that both PE and PVDF have shown a good sensitivity to pressure. The measured levels of hysteresis and repeatability are similar to that previously measured for polymer devices (Arshak et al., 1995 and Arshak et al., 2000). PVDF is best suited to the measurement of pressure in the range 0100kPa. PE could also be used over this range, but it is expected that because of its lower Youngs modulus, the sensor would experience a high level of hysteresis and slippage of the polymer chains during its operation. However, for medical purposes, it is not likely, that measurements over a pressure of 40kPa will be required. In this respect, PE is more suited for the measurement of physiological processes.4. ConclusionIn this work, the pressure sensing properties of sandwich capacitors based on PE and PVDF were evaluated using a specially constructed data acquisition system. It was seen that each material displayed a high sensitivity to pressure changes in the range 017kPa. It was found that the PE sensors were the most sensitive, but each device displayed low hysteresis and repeatability. It can be concluded that PE is the most sensitive to pressures over a small range, however PVDF could find applications in systems where pressu
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- GB/T 26832-2026无损检测仪器钢丝绳电磁检测仪技术条件
- 简述多重耐药菌防控操作流程
- 2027年寒假开学摸底考试三年级英语测试卷
- 高二化学复习卷(2027年5月模拟考试)
- 八年级化学复习卷(2026-2027学年上学期单元测试)
- 2027年春季开学考试高三地理练习卷
- 2027年寒假开学摸底考试八年级化学基础卷打印版
- 2027年内蒙古中考二模历史试卷
- 儿童失踪紧急响应与搜寻指导书
- 游戏开发行业软件工程师绩效衡量表
- 视频监控系统试运行调试报告
- 4.1妈妈教学设计
- 神经内科诊疗新技术
- 非煤矿山安全生产管理与技术培训
- 双侧前庭病诊断与治疗专家共识
- 110kV变电站电气调试实施方案
- 八年级物理第二学期期中考试质量分析
- 心脏MRI在急性心肌梗死诊断中的临床价值与应用
- 两品一械培训
- 2026 年离婚协议书 2026 版民政局专用模板
- GB/T 7714-2025信息与文献参考文献著录规则
评论
0/150
提交评论