Error code:0System working correctly2Memory test failed:Remove the power to the PLS for at least 3 seconds. If the problem persists, consult the Sick Hotline.17-20Contamination of front screen:Clean the front screen or replace it as necessary (note that you must run Balance Contamination Measurement after replacing).24Mutual interference between other PLS units:Eliminate the interference by modifying the mounting of the PLS units. Refer to the mounting instructions in section 7.Motor speed incorrect:Operation at low temperatures. Be sure to comply with the device specifications (see technical data).27External circuitry of OSSD 1 faulty:Check the external wiring. Test for short circuit of OSSD1 to 0 Volts, to 24 V and to the second OSSD. Make sure the resistive and capacitive loading of the outputs conforms to the device specifications. Also check the connectors and cable terminations .Undervoltage supply to device:Make sure the voltage supply to the device conforms to the technical data set out in the specifications. Measure the voltage directly on the PLS to take account of any voltage drop resulting from long supply leads.28External circuitry of OSSD2 faulty:Check the external wiring. Test for short circuit of OSSD1 to 0 Volts, to 24 V and to the second OSSD. Make sure the resistive and capacitive loading of the outputs conforms to the device specifications. Also check the connectors and cable terminations.Undervoltage supply to device:Make sure the voltage supply to the device conforms to the technical data set out in the specifications. Measure the voltage directly on the PLS to take account of any voltage drop resulting from long supply leads.29Motor speed not correct:Operation at low temperatures. Be sure to comply with the device specifications (see technical data).31Sensor glare during a measurement:Check whether the PLS is subject to glare from an external light source, such as spotlamps, infrared light, the sun etc. You may be able to remedy the problem by modifying the mounting of the PLS slightly. (Refer to the mounting instructions set out in section 5). When in use on an AGV, check that the Vehicle protection application variant is selected.32Object in warning field:Check the monitored area. Modify the configuration of the PLS if necessary to conform to the monitored area conditions.33Object in protective field:Check the monitored area. Modify the configuration of the PLS if necessary to conform to the monitored area conditions.41Incorrect Output operation:Check the external wiring. Test for short circuit of OSSD to 0 Volts, to 24 V and to the second OSSD. Make sure the resistive and capacitive loading of the outputs conforms to the device specifications. Also check the connectors and the cable terminations .Undervoltage supply to device:Make sure the voltage supply to the device conforms to the technical data set out in the specifications. Measure the voltage directly on the PLS to take account of any voltage drop resulting from long supply leads.42Sensor receiving data over 90 of its measuring range:To ensure fault-free operation of the sensor, the PLS will after 3 seconds signal an error if it receives object detection that is greater than 90 of its scan area. In vehic

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

最新文档

评论

0/150

提交评论