




已阅读5页,还剩11页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
CUTE-LV SERIES ULTRASONIC WATER METERPRODUCT INTRODUCTIONCHANGZHOU CUTE INTELLIGENT CO.,LTD 1、 Overview CUTE serial ultrasonic water meter module is the core part to work with the base meter to measure and display the water flow. CUTE serires ultrasonic water meter with the M-BUS interface, The staff can read the meter data at any time by the remote reading management system with the M-BUS interface and other device. 2、Function and Characteristic2.1 Under voltage warning;2.2 Automatic error correction tech;2.3 Temperature sensor cut and short circuit warning;2.4 Flow sensor failure warning;2.5 High definition and wide temperature LCD;2.6 Wide range ratio;2.7 Lithium battery life is more than 6+1;2.8 Can read the meter data by infrared tool at the spot;2.9 With the M-BUS interface;3、Usage instruction1.The water meter operated by the menu, can change the work condition and display contents by the button on panel; There are 4 menu, the default is main menu, the change flow is as below:Main menu xxxxx.xxx m3【F】【I】【E】 Means the long press time 2s;1) Main menu: normal condition; 2) Error menu【E】 3) Information menu【I】 4) Verification program【F】 The screen is off when stand by, press the button to awake the meter and enter the main menu, which show the accumulated flow(above figure), long press to change menu and read the data you need, the screen will be off after 3 minutes without any operation except the verification program【F】. Main Menu XXXXX.XXX m3XX.XXX m3/hAccumulation XXXXXXXX h DN20X.X.X.X.X.XXXInstant flowWork timeTypeFull screen Press2s Vacant pipe error (date)【E】1 XX.XX.XX S 2 XX.XX.XX SBattery fault (date)3 XX.XX.XX SReflux error (date)4 XX.XX.XX SSurpass the range ratio (date)Water temperature error (date)1 XXXXXXX h Accumulated time 2 XXXXXXX hAccumulated time program【F】 3 XXXXXXX hAccumulated time program【F】 4 XXXXXXX hAccumulated time program【F】 5 XXXXXXX hEE fault (date) 6 XXXXXXX hError menu operation【E】 5 XX.XX.XX S6 XX.XX.XX STranducer fault flow in (date) 7 XXXXXXX h7 XX.XX.XX STranducer fault flow out (date)换能器故障 出水端 发生日期(年月日) 8 XXXXXXX h8 XX.XX.XX SLong press 2sPress2sPress2.r-xx.xx.xx Y M DXXXXXXXXXXXXXXXXr XX d-xx.xx.xx Y M D xx.xx.xx H M S 【I】Main addSecond addEditionPresent datePresnet timeLast month Reading time r-xx.xx.xx Y M Dr-xx.xx.xx Y M D XXXX.XXX m3 XXXX.XXX m3Last 2 months ReadingLast 24 months Reading.Last 3 months Reading r-xx.xx.xx Y M D XXXX.XXX m3 XXXX.XXX m3Information Menu【I】 Verifivcation Menu【F】【F】 XXX.XXXXX m3FXX.XXXXF XX.XXXFXX.XXXF XXX.XXXXX m3/hF XX.XXFXX.XXXXFDirect flow usTime difference nsReflus time usZero clearSignal indicationWater temperature瞬流 Instant flowAccumulated flowRemark:Under the verification menu, the accumulated flow and heat can be zero clear automatically, when the flow rate is 0,,if detect the flow rate in pipe is higher than the set point, zero clear the present accumulated data; When cant make zero clear under some extrem conditio, which can be done by manual;Exit the verification menu without any operation in 2 hours;Press2s按大于2秒4、Characteristics:Accumulated volume definition0.001m(working)0.00001m(verifying)Present flow definition 0.001 m3/h(working) 0.001 m3/h (verifying)Measure rangeQ3/Q1=400Quiescentcurrent 6+1 yearLCD digits8 Max accumulated time4.2x109 hoours(work time99999999, only display the last 8 valid digits)Max accumulated flow4.2x109 m(flow99999.999 m, only display the last 8 valid digits)Accuracy classII class5、Failure analysis and solutionNo.ProblemCauseSolution1Battery faultUnder vlotage or bad connectionCheck the connector, change the battery;2Vacant pipe faultNo water or not full in the pipeFill the pipe full and eliminate the bubble3Reflux faultThe inflow and outflow reverseAdjust the inflow and outflow4Surpass range ratio The present instant flow is too highLower the flow or change the meter5Water temperature Water temperature faultLower the temperature or change the meter6EE faultEE storage invalidChange the PCB7Transducer InflowChange or reinstall the transducer8TransducerOutflowChange or reinstall the transducer6、PCB connector and outlineBattery connectorButtonLCD Note:Please read the documents carefully before using the products;If any qutstion, please dont hesitate to contact with us; Special instruction for the verification mode(1).Enter the verificaiton modeMain menu KWh【F】【I】【E】After turning on the water meter, press the button until seeing the 【F】,then press again to see the below content:Accumulation Flow 0.00000 m3Verification(2).Menu clausePress the button every time, you will see the caluse in order, please see thedetails in page 6;(3).NoteUnder the verification mode, the acc
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025北京市药品检验研究院(北京市疫苗检验中心)人才引进3人模拟试卷及参考答案详解1套
- 2025年合肥经济学院人才招聘72人模拟试卷(含答案详解)
- 2025春季内蒙古包头市中心医院引进高层次和紧缺急需人才招聘29人考前自测高频考点模拟试题及1套完整答案详解
- 2025江西省人民医院招聘康复治疗师助理2人模拟试卷及答案详解(名校卷)
- 2025福建泉州市面向教育部直属师范大学福建省生源公费师范生、福建省内高校泉州生源公费师范生招聘编制内新任教师52人考前自测高频考点模拟试题完整答案详解
- 2025广西北海市市场投资发展集团有限公司招聘5人模拟试卷及一套答案详解
- 2025年潍坊护理职业学院公开招聘控制总量工作人员(30人)模拟试卷附答案详解(黄金题型)
- 2025内蒙古巴林左旗林业和草原局国有公益林护林员招聘66人考前自测高频考点模拟试题及答案详解参考
- 2025年合肥经济学院人才招聘72人模拟试卷附答案详解(典型题)
- 2025年上半年上海市卫生健康技术评价中心工作人员公开招聘模拟试卷及参考答案详解
- 山西中考语文5年(21-25)真题分类汇编-文学类文本阅读
- 2025云南红河红家众服经营管理有限公司社会招聘工作人员8人笔试模拟试题及答案解析
- 蒋诗萌小品《谁杀死了周日》台词完整版
- JJG 707-2014扭矩扳子行业标准
- 超短波在植物病害防治中的应用
- 新媒体运营课件
- 《热敏电阻传感器》课件
- 志愿服务证明(多模板)
- 深圳市养老保险延趸缴申请告知承诺书
- D-阿洛酮糖团体标准
- JGJ114-2014 钢筋焊接网混凝土结构技术规程
评论
0/150
提交评论