流化床温湿度确认验证部于2015.04.07对一车间101区小GEA流化床和102区GLATT流化床的进风温湿度进行确认,对101区流化床转轮除湿机关闭和开启分别测量,测试开关除湿机对进风温湿度的影响。数据与结论如下:101区小GEA流化床:进风温度设定值:40 进风量:450m/h测量仪器:圆盘记录仪记录频率:每分钟一次条件:空载条件进风湿度%进风温度机器显示进风温度转轮除湿关闭时24.336.035.820.439.238.721.138.638.321.138.538.320.539.138.820.539.238.820.639.038.8条件进风湿度%进风温度机器显示进风温度转轮除湿开启5.438.938.95.938.838.86.138.538.55.838.338.35.238.238.25.438.538.35.138.838.65.439.138.85.338.138.75.838.438.4102区GLATT流化床:条件进风湿度%进风温度机器显示进风温度进风温度设定值:40 进风量:2800m/h22.840.839.923.540.240.023.239.740.023.439.739.822.940.140.223.139.840.123.439.740.123.639.640.023.639.540.023.639.540.023.639.540.0101区大GEA流化床:进风温度设定值:40 进风量:3600m/h测量仪器:圆盘记录仪条件:空载条件进风湿度%进风温度机器显示进风温度转轮除湿关闭时23.136.834.023.636.134.422.737.034.722.237.335.222.137.535.521.937.635.722.037.635.721.937.735.821.937.735.921.837.836.021.737.836.021.737.936.2条件进风湿度%进风温度机器显示进风温度转轮除湿开启11.838.937.712.238.837.711.438.837.711.838.737.612.138.737.6结论:对101区大小GEA流化床转轮除湿前后测量结果对比可知,设备本身产品温度探头误差在1范围内,符合要求,转轮除湿开启关闭对进风湿度影响很大。102区GLATT设备本身产