ChinaChina HengweiHengwei OPERATION AND MAINTENANCE MANUAL FOR AUTO CONTRAL SYSTEM FOR AHU UNIT Hengwei Air Clean Equipment Co Ltd Suzhou China 1 PREFILE Controller 恒 威 环 控 China Hengwei 2 EXCEL50 控制器是 Honeywell 楼宇自动化系统中的现场 DDC 控制单元 EXCEL50 控制器采用 Flash EPROM 模块可自由编程适用于 Honeywell 的 CARE 编程软件包 控制器可根据需要提供不同的现场预制程序 EXCEL50 controller is the on site DDC controlling unit in Honeywell Building Automation System It adopts Flash EPROM Module which is programmable on the basis of Honeywell CARE programming software package Different site precasting programmes are available as required 硬件部分硬件部分 Hardware 结构结构 Structure 8 路通用传感器输入路通用传感器输入 Analog input 8 General sensor input Analog input 4 路无源数字量输入路无源数字量输入 Digital input 4 Passive digital value input Digital input 6 路数字点输出路数字点输出 Digital output 6 Digital point output Digital output 4 路模拟点输出路模拟点输出 Analog output 4 Analog point output Analog output I O 点特性点特性 I O Property 通用输入 通用输入 NTC 热敏电阻 热敏电阻 0 10VDC 信号 信号 4 20mA 信号 信号 General Input NTC thermistance 0 10VDCsIGNAL 4 20Ma signal 数字输入 无源数字输入 无源 ON OFF 接点 逻辑电平 记数脉冲 接点 逻辑电平 记数脉冲 Digital Input Passive ON OFF connection point logic level numeration pulse 通用输出 模拟输出通用输出 模拟输出 0 10VDC General output Analog output0 10VDC 数字输出 数字输出 TRAIC 输出 输出 Digital Output TRAIC Output 2 Specifications 技术规范技术规范 Technical specification China Hengwei 3 工作电压工作电压 Voltage 24VAC 工作频率工作频率 Frequency 50 60HZ 输入分辨率输入分辨率 Input resolution 0 1K 1MA 电压调节信号电压调节信号 Voltage regulation signal 0 10V 查询速度和刷新时间查询速度和刷新时间 1S Inquiry time Press to return to the front page 4 Troubleshooting 五 故障处理 五 故障处理 1 Analog Input 内的内的 RT RH 参数能正常显示 但是严重超标 参数能正常显示 但是严重超标 A 如果 如果 Analog Output 内的参数内的参数 CV HV HumV 均显示为均显示为 0 那么检查 那么检查 Digital Input 参数是否为参数是否为 off 如果是 如果是 off 那么就是 那么就是 AHU 风机未启动 或者是风机未启动 或者是 AHU 风机的风机的 DPS 故障 表现为皮管松脱或者皮管内有凝结水 故障 表现为皮管松脱或者皮管内有凝结水 DPS 的设定值太大导致的设定值太大导致 DPS 未动作未动作 可用人工吹气判断 可用人工吹气判断 DPS 损坏或线路断开 损坏或线路断开 B 如果 如果 Analog Output 内的参数内的参数 CV HV HumV 显示有的为显示有的为 0 有的 有的 50 或更或更 大 可将温湿度传感器从风管内拔出 放置在空气中 约大 可将温湿度传感器从风管内拔出 放置在空气中 约 2 分钟后检查分钟后检查 DDC 的的 RT RH 参数是否与空气的温湿度基本一致 若偏差较大 那么应更换回风管上的温湿度传感器 参数是否与空气的温湿度基本一致 若偏差较大 那么应更换回风管上的温湿度传感器 China Hengwei 8 2 Analog Input 内的内的 RT RH 参数出现负数 检查传感器接线 确认接线正常后更换温参数出现负数 检查传感器接线 确认接线正常后更换温 湿度传感器 湿度传感器 3 若若 DDC 出现显示界面出现显示界面 Firmware version V 2 07 01 那么是由于 那么是由于 DDC 在特殊情在特殊情 况下 因为断电丢失程序 或者遭人为丢失程序 解决方法 一直按况下 因为断电丢失程序 或者遭人为丢失程序 解决方法 一直按 NEXT 直到出现 直到出现 Select Applic 移动光标并选择 移动光标并选择 Select Applic 移动光标并选择 移动光标并选择 DDC1 03 03 10 按确按确 认键重新载入程序 认键重新载入程序 Troubleshooting Analog Input of RT RH parameters can appear as normal but excessive A If CV HV HumV of the parameters in Analog Output are displayed as 0 check the Digital Input parameter if it is off it shows the AHU fan does not to start or the AHU fan is failure of the DPS It may result from the tubed loosing or tube having condensed water the set value of DPS is too large to cause a DPS not action artificial blowing judgment needed DPS damaged or loop line break B If CV HV HumV of the parameters in Analog Output are displayed is 0 some are 50 or larger please take off the temperature and humidity sensor from air duct and set them in the air check the parameter RT RH of DDC about 2 minutes after and confirm whether they are subject to essentially the same to the air temperature and humidity measured Replace the temperature and humidity sensor on the return air duct if the deviation is larger RT RH of the Analog Input is a negative value Check the sensor wiring confirm that the connection is right or not if it is right replace the temperature and humidity sensor If the DDC appear interface Firmware version V 2 07 01 it is due to the program of DDC has lost because the failed or wrong operation Solution always press NEXT until Select Applic appear Move the cursor and choose Select Applic move the cursor and select DDC1 03 03 10 press ENTER to reload the program of DDC 六 注意事项六 注意事项 Cautions 1 操作密码和修改密码不允许任意修改 操作密码和修改密码不允许任意修改 Arbitrarily changes of Operation Code and Modification Code are not allowed 2 维护人员必须为专业空调和电气人员 维护人员必须为专业空调和电气人员 Maintenance personnels shall be professional AC and electrical specialty China Hengwei 9 七 七 DDC 培训确认单培训确认单 1 DDC 操作培训操作培训 Training for DDC Operation 2 DDC 芯片更换 备用芯片已移交 芯片更换 备用芯片已移交 Replacement for DDC chips Spare chips have been transferred to the owner 3 系统备件更换系统备件更换 Replacement of system spares China Hengw

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论