




已阅读5页,还剩42页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
EMCCLARiiON安装及配置 CLARiiON安装配置 GatherNetworkInformationVerifyPowerSupplySettingsConfirmtheStandbyPowerSupply SPS ConnectionsStartTheFC4700InitializetheFC4700ConnectaManagementStationConfigureTheFC4700MakeSwitchAndHostConnectionsSetupTheHostsCreatTheFC4700StorageGroupCompleteTheHostSetupSetupSnapViewAndMirrorViewSoftWareSetupEventMonitor BeforeYouStart Confirmthatelectricalwiringisinplaceatyourfacilitytoaccommodatethecabinet stwo240 voltacpowercables TosupportalloftheFC4700high availabilityfeatures youmustconnecteachpowerdistributionunittoadifferentcircuit 2 Verifythatyourfacilityhasadequatenetworkwiringforyoursub network subnet connections Tomanagethestoragesystem eachstorageprocessor SP requiresaseparatnetworkconnection 3 IfyourenvironmentincludesswitchesonthepathbetweentheFC4700andthehosts servers thathaveaccesstoit makesuretheswitchesareinstalled Refertothedevice specificinstallationmanualsforeachswitch 4 VerifythattheStandbyPowerSupplies SPSs DiskProcessorEnclosure DPE andanyoptionalDiskArrayEnclosures DAEs areinstalledinyourcabinet Ifnecessary refertotheappropriatecabinet rail ordevicehardwareinstallationdocumentationyoureceivedwithyoursystem BeforeYouStart 5 HavethenetworkadministratoratyourfacilitysetupIPaddressesfortheFC47006 MakesurethatthelatestrevisionsofNavisphereManagerandEventMonitorareinstalledontheWindows2000orWindowsNThostyouwilluseastheNavispheremanagementstation BeforeYouStart SP ASP BHostname Upto15alphanumericcharacters Dashesareacceptable Specialcharacterssuchasdots spaces orunderscoresarenotallowed Examples Array1 A Array1 B IPAddress SubnetMask Gateway Step1GatherNetworkInformation Step2VerifyPowerSupplySetting Removethediskdrivefanpack 2 Confirmthatthepowerswitchoneachpowersupplybehindthefanpackison thenreplacethefanpack Step3ConfirmtheStandbyPowerSupplyConnection 1 StandbypowersupplyA SPS A connectstothelowerserialport COM2 ofSP A 2 StandbypowersupplyB SPS B connectstothelowerserialport COM2 ofSP B Step4StartFC4700 1 Plugthetwo240 voltacpowercablesintothepoweroutletsinyourfacility Werecommendconnectingeachpowercabletoadifferentbranchcircuit ConnectingonlyonepowersourcewilldegradetheFC4700 sperformance 2 Turnonthecircuitbreakersoneachofthecabinet ssidepowerstrips 3 Turnonthepowerswitchoneachstandbypowersupply IfwarninglightsappearonthefrontoftheDPE makesurethesystemiscorrectlycabled Step4StartFC4700 Step5InitalizeTheFC4700 InitializingtheFC4700requiresadirectlyconnectedcomputer usuallyalaptopmodel thatwerefertoasaservicelaptop IMPORTANTThefollowingguidelinesoutlinehowexperiencedtechnicalpersonnelinitializeanFC4700storagesystem ServiceLaptopSetup1 ConnecttheservicelaptoptotheserialportonSP Awiththenullmodemcable 2 MakesureDial UpNetworkingbetween2PCsisinstalledandsetupontheservicelaptop 3 SetupDial UpNetworking 4 Modifythelaptop sTCP IPnetworksettingstouseDHCP Step5InitalizeTheFC4700 CriticalParameterSetupOntheFC4700 5 Setupauseraccount 6 CreatethePersistentStorageManagement PSM LUN 7 SpecifyprivilegedusersfortheFC4700 8 SettheSPStesttimeforeachSPSinyoursystem Step5InitalizeTheFC4700 NetworkInformationSetup9 Specifythehostname IPaddress subnetmask andgatewayaddressforSP A UsetheinformationyoucollectedandenteredearlierinStep1 GatherNetworkInformation 10 DisconnecttheservicelaptopfromSP AandconnectittotheserialportonSP B 11 Specifythehostname IPaddress subnetmask andgatewayaddressforSP B Step5InitalizeTheFC4700 SPALPHASCSIIDSetup12 UseNavisphereManagertoselecteachFC4700 2SPAgenttobemanaged 13 SettheALPHASCSIIDvalueforeachportonSP AandSP B 14 SetthedesiredFCspeedforeachportonSP AandSP B SetupConfirmation15 Makecertainallsoftwarepackagesarecommitted InNavisphereManager checktheSoftwaretaboftheArrayPropertiesselectionforanysoftwarepackagesrequiringaCOMMIT Step5InitalizeTheFC4700 Step6ConnectaManagementStation ConnecteachSPseparatelytotheLANtowhichyourNavispheremanagementstationisconnected Step7ConfigureTheFC4700System 1 SelecttheFC4700storagesystemyouwanttoconfigure OptionalFC4700SoftwareInstallation2 IfyouhavetheAccessLogixsoftware installitwithanondistruptiveinstallation NDU IfyouhaveSnapVieworMirrorViewsoftware installtheminasubsequentNDU Refertotheoption specificdocumentationasappropriate Makecertainallsoftwarepackagesarecommitted InNavisphereManager checktheSoftwaretaboftheArrayPropertiesselectionforanysoftwarepackagesrequiringaCOMMIT Performthecommitifnecessary RemoteSPAgentConfiguration3 SpecifyanyadditionalprivilegedusersforeachSP Storage SystemPropertiesSetup4 Setthegeneralconfigurationproperties enableautomaticpolling automaticpollingpriority andSP AandSP Bstatisticslogging 5 SetthereadandwritecachememorypropertiesforeachSP 6 SettheFC4700cacheproperties 7 IftheFC4700isrunningAccessLogix setthedataaccessproperty Step7ConfigureTheFC4700System Removetheprotectivecoversfromeachopticalconnectorandcable 2 PlugthecablesintotheSPhostports 3 ConnecttheotherendofthePort0 top cableasfollows Foradirectattachconfiguration tothehostserver shostbusadapter NOTEIftheHBAisnotyetinstalledinthehostserver completeStep9 thenconnecttheSP Step8MakeSwitchorHostConnect 4 ConnecttheotherendofthePort1 bottom cableasfollows InasystemwithoutMirrorView toanHBAport directattachconfigurations orswitchport SANconfigurations InasystemwithMirrorView toastorageprocessor SP hostportontheremotestoragesystem Step8MakeSwitchorHostConnect Step9SetuptheHost HBAandDriverInstallationCompletethefollowingtasksoneachhostthatwillusethestoragesystem 1 Installthehostbusadapters HBAs inthehost Refertothe EMCFibreChannelHBAandDriverInstallationGuideand EMCFibreChannelHBA DriverReleaseNotesappropriateforyouroperatingsystem 2 ForaSANconfiguration connecteachHBAtotheappropriateswitchport 3 Foradirectattachconfiguration connecteachHBAtotheappropriateSPport 4 InstalltheHBAdriverandanyutilitiesfromtheHBAmedia ifappropriate oneachhost 5 SwitchZoneCreationRefertothedevice specificdocumentationprovidedwithyourFibreChannelswitch es tocompletethefollowing 6 Oneachswitchfabric createazoneforeachHBAandalltheSPportsthatyouwanttheHBAtoaccess UseWorldWidePortNames WWPNs tospecifytheHBAandtheSPportsforthezone Step9SetuptheHost HBAandDriverInstallation continued 7 InstallCLARiiONDriverExtension CDE softwareifCDEisavailableforyourhost andyourconfigurationrequiresit FC4700storagesystemssupportCDEinIBMAIX SunSolaris andMicrosoftWindowsNTandWindows2000environments ConfigurationswithonlyonehostHBArequireCDE 8 Activatethedriver Dependingonthehost youmayneedtorebootthehost Step9SetuptheHost NavisphereHostSoftwareInstallation1 IfthehosthasmultipleHBAsconnectedtothestoragesystemandNavisphereApplication TransparentFailover ATF isavailable installATF FC4700storagesystemssupportATFinAIX NovellSolaris WindowsNTandWindows2000environments 2 InstalltheNavisphereHostAgentandoptionalCLI 3 ActivatetheATFdevicesandHostAgentbyrebootingthehost 4 IfyouplantoinstallSnapViewsoftware installtheadmsnaphostmanagementutilitysoftware Step9SetuptheHost Step10CreateFC4700StorageGroup CreateaRAIDGroupRight clickstoragesystem Select CreateRAIDGroup inmenu Chooseeitherbasicoradvanceddialog Inadvanceddialog diskscanbeselectedmanually 2 BindaLUNInaRAIDGroup Step10CreateFC4700StorageGroup Right clickstoragesystemicon Inmenu select BindLUN Choosebasicoradvancedbinddialog Selectoptionsandclick Apply 3 AccessLogix Step10CreateFC4700StorageGroup Use DetailedView togetanoverviewoftheAccessLogixsetup Select DetailedView fromtheright clickmenuforthestoragesystem Alliconsareactive 4 TurningOnAccessLogixusingNavisphereManager Step10CreateFC4700StorageGroup Right clickstoragesystemiconandselect Properties Goto DataAccess tab Checkthe AccessControlEnabled checkbox Click OK Cannotbeunchecked 5 CreatinganddestroyingStorageGroupsusingManager Step10CreateFC4700StorageGroup Right clickstoragesystemiconandselect CreateStorageGroups Specifynameforstoragegroup MoveLUNstothe SelectedLUNs area CheckwhetherSGshouldbededicatedorsharable 6 ConnectingHostsUsingNavisphereManager Step10CreateFC4700StorageGroup Findstoragegroupin StorageGroups folderin Storage tab Right clickSGandselect ConnectHosts Movehostsbetweenareas Click OK or Apply 7 ChangingStorageGroupSettingsUsingNaviManager Step10CreateFC4700StorageGroup Right clickstoragegroupiconandselect Properties Makechangesinthepropertydialog Click OK or Apply 8 AddingorRemovingLUNsfromStorageGroupusingManager Step10CreateFC4700StorageGroup Inpropertydialogforstoragegroup click SelectLUNs MoveLUNsbetweenthetwoareas Click OK Click OK againinpropertiesdialog Step11CompletetheHostSetup RefertotheappropriateEMCNavisphereServerSoftwareSetupGuidetocompletethefollowingforeachhostthatwillusethestoragesystem 1 MaketheLUNsforeachhostavailabletothehost soperatingsystem Dependingontheoperatingsystem thismayinvolve LabelingandpartitioningLUNsMakingfilesystemsorcreatingvolumesonthepartitionsMountingthefilesystemsorvolumes 2 Ifhostsareclustered setuptheclusteringsoftwaretoworkwiththeFC4700 2 clicksessionSelect Properties CLARiiONCX600 InitializingtheCX600WithNavisphere6 1 Overview ConfigurationstepssimilartoFC4700withNavisphere6 05 noPSMsetup ServiceLaptopRequirements WindowsNTorWindows2000InternetExplorer5 5orNetscape6 0JavaRuntimeEnvironment1 3 1 01Navisphere6 1ManagementUI new SerialPPPConnectionSerialCable InitializingtheCX600 ConfiguretheServiceLaptopSettheStorageProcessorTCP IPParametersforSP AandSP BSettheArrayDateandTimeConfigureOperatingParametersCommitBaseSoftwarePerformNDUtoUpgradeorAddOptionalSoftwareComponentsConfigureRead WriteCacheCreateRAIDGroups StorageGroups BindLUNs andConnectHosts ConfiguringtheServiceLaptop InstalltherequiredServiceUINavispheresoftwareJava1 3 1 01Navisphere6 1WindowsUINavisphereCLICreateaWindowsdial upnetworkingPPPconnection ConfigureSP AIPParameters ConnectserialcabletoSP AEstablishaPPPnetworkconnectiontoSP AOpenInternetbrowserto http 192 168 1 1 setupSetnetworkpropertiesforSP AIPAddress Hostname SubnetMask Gateway PeerIPAddressApplysettings SP Areboots DisconnectserialcablefromSP A StorageProcessorNetworkSetupViaSerialPPPSession ConfigureSP BIPParameters ConnectserialcabletoSP BEstablishaPPPnetworkconnectiontoSP BOpenInternetbrowserto http 192 168 1 1 setupSetnetworkpropertiesforSP BIPAddress Hostname SubnetMask Gateway PeerIPAddressApplysettings SP Breboots DisconnectserialcablefromSP B RestartSP A sManagementServer Re connecttheserialcabletoSP AEstablishPPPsessiontoSP AOpenInternetbrowserto http 192 168 1 1 setupClickRestartManagementServerCheckYestorestarttheManagementServerWait60SecondsfortheManagementS
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 证券从业考试登录名错误及答案解析
- 南华大学护理习题库及答案解析
- 机修工安全题库及答案解析
- 考点解析人教版八年级上册物理声现象《声音的特性声的利用》同步测评试卷(附答案详解)
- 2025年人力资源管理师专业技能考核试卷:员工关系管理与冲突解决试题库
- 2025年素描构图考研真题及答案
- 财务部部长演讲稿15篇
- 2025年中学教师资格考试《综合素质》教育案例题库冲刺实战试题及答案
- 2025年乡村医生考试题库(农村急救技能操作)真题模拟解析
- 2025年大学《马来语》专业题库- 马来语诗歌的象征主题
- 信息论与编码(第4版)完整全套课件
- 汽修厂安全风险分级管控清单
- GB/T 2679.7-2005纸板戳穿强度的测定
- GB/T 25840-2010规定电气设备部件(特别是接线端子)允许温升的导则
- GB/T 25146-2010工业设备化学清洗质量验收规范
- 参考资深同传
- 多功能注氧仪说明书课件
- 科隆电磁流量计培训课件
- 全集举一反三课件奥数五年级(数学)
- 中国民间故事整本书导读课教学设计
- 商业银行贷款风险分类实务
评论
0/150
提交评论