




已阅读5页,还剩42页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
EMCCLARiiON安装及配置 CLARiiON安装配置 GatherNetworkInformationVerifyPowerSupplySettingsConfirmtheStandbyPowerSupply SPS ConnectionsStartTheFC4700InitializetheFC4700ConnectaManagementStationConfigureTheFC4700MakeSwitchAndHostConnectionsSetupTheHostsCreatTheFC4700StorageGroupCompleteTheHostSetupSetupSnapViewAndMirrorViewSoftWareSetupEventMonitor BeforeYouStart Confirmthatelectricalwiringisinplaceatyourfacilitytoaccommodatethecabinet stwo240 voltacpowercables TosupportalloftheFC4700high availabilityfeatures youmustconnecteachpowerdistributionunittoadifferentcircuit 2 Verifythatyourfacilityhasadequatenetworkwiringforyoursub network subnet connections Tomanagethestoragesystem eachstorageprocessor SP requiresaseparatnetworkconnection 3 IfyourenvironmentincludesswitchesonthepathbetweentheFC4700andthehosts servers thathaveaccesstoit makesuretheswitchesareinstalled Refertothedevice specificinstallationmanualsforeachswitch 4 VerifythattheStandbyPowerSupplies SPSs DiskProcessorEnclosure DPE andanyoptionalDiskArrayEnclosures DAEs areinstalledinyourcabinet Ifnecessary refertotheappropriatecabinet rail ordevicehardwareinstallationdocumentationyoureceivedwithyoursystem BeforeYouStart 5 HavethenetworkadministratoratyourfacilitysetupIPaddressesfortheFC47006 MakesurethatthelatestrevisionsofNavisphereManagerandEventMonitorareinstalledontheWindows2000orWindowsNThostyouwilluseastheNavispheremanagementstation BeforeYouStart SP ASP BHostname Upto15alphanumericcharacters Dashesareacceptable Specialcharacterssuchasdots spaces orunderscoresarenotallowed Examples Array1 A Array1 B IPAddress SubnetMask Gateway Step1GatherNetworkInformation Step2VerifyPowerSupplySetting Removethediskdrivefanpack 2 Confirmthatthepowerswitchoneachpowersupplybehindthefanpackison thenreplacethefanpack Step3ConfirmtheStandbyPowerSupplyConnection 1 StandbypowersupplyA SPS A connectstothelowerserialport COM2 ofSP A 2 StandbypowersupplyB SPS B connectstothelowerserialport COM2 ofSP B Step4StartFC4700 1 Plugthetwo240 voltacpowercablesintothepoweroutletsinyourfacility Werecommendconnectingeachpowercabletoadifferentbranchcircuit ConnectingonlyonepowersourcewilldegradetheFC4700 sperformance 2 Turnonthecircuitbreakersoneachofthecabinet ssidepowerstrips 3 Turnonthepowerswitchoneachstandbypowersupply IfwarninglightsappearonthefrontoftheDPE makesurethesystemiscorrectlycabled Step4StartFC4700 Step5InitalizeTheFC4700 InitializingtheFC4700requiresadirectlyconnectedcomputer usuallyalaptopmodel thatwerefertoasaservicelaptop IMPORTANTThefollowingguidelinesoutlinehowexperiencedtechnicalpersonnelinitializeanFC4700storagesystem ServiceLaptopSetup1 ConnecttheservicelaptoptotheserialportonSP Awiththenullmodemcable 2 MakesureDial UpNetworkingbetween2PCsisinstalledandsetupontheservicelaptop 3 SetupDial UpNetworking 4 Modifythelaptop sTCP IPnetworksettingstouseDHCP Step5InitalizeTheFC4700 CriticalParameterSetupOntheFC4700 5 Setupauseraccount 6 CreatethePersistentStorageManagement PSM LUN 7 SpecifyprivilegedusersfortheFC4700 8 SettheSPStesttimeforeachSPSinyoursystem Step5InitalizeTheFC4700 NetworkInformationSetup9 Specifythehostname IPaddress subnetmask andgatewayaddressforSP A UsetheinformationyoucollectedandenteredearlierinStep1 GatherNetworkInformation 10 DisconnecttheservicelaptopfromSP AandconnectittotheserialportonSP B 11 Specifythehostname IPaddress subnetmask andgatewayaddressforSP B Step5InitalizeTheFC4700 SPALPHASCSIIDSetup12 UseNavisphereManagertoselecteachFC4700 2SPAgenttobemanaged 13 SettheALPHASCSIIDvalueforeachportonSP AandSP B 14 SetthedesiredFCspeedforeachportonSP AandSP B SetupConfirmation15 Makecertainallsoftwarepackagesarecommitted InNavisphereManager checktheSoftwaretaboftheArrayPropertiesselectionforanysoftwarepackagesrequiringaCOMMIT Step5InitalizeTheFC4700 Step6ConnectaManagementStation ConnecteachSPseparatelytotheLANtowhichyourNavispheremanagementstationisconnected Step7ConfigureTheFC4700System 1 SelecttheFC4700storagesystemyouwanttoconfigure OptionalFC4700SoftwareInstallation2 IfyouhavetheAccessLogixsoftware installitwithanondistruptiveinstallation NDU IfyouhaveSnapVieworMirrorViewsoftware installtheminasubsequentNDU Refertotheoption specificdocumentationasappropriate Makecertainallsoftwarepackagesarecommitted InNavisphereManager checktheSoftwaretaboftheArrayPropertiesselectionforanysoftwarepackagesrequiringaCOMMIT Performthecommitifnecessary RemoteSPAgentConfiguration3 SpecifyanyadditionalprivilegedusersforeachSP Storage SystemPropertiesSetup4 Setthegeneralconfigurationproperties enableautomaticpolling automaticpollingpriority andSP AandSP Bstatisticslogging 5 SetthereadandwritecachememorypropertiesforeachSP 6 SettheFC4700cacheproperties 7 IftheFC4700isrunningAccessLogix setthedataaccessproperty Step7ConfigureTheFC4700System Removetheprotectivecoversfromeachopticalconnectorandcable 2 PlugthecablesintotheSPhostports 3 ConnecttheotherendofthePort0 top cableasfollows Foradirectattachconfiguration tothehostserver shostbusadapter NOTEIftheHBAisnotyetinstalledinthehostserver completeStep9 thenconnecttheSP Step8MakeSwitchorHostConnect 4 ConnecttheotherendofthePort1 bottom cableasfollows InasystemwithoutMirrorView toanHBAport directattachconfigurations orswitchport SANconfigurations InasystemwithMirrorView toastorageprocessor SP hostportontheremotestoragesystem Step8MakeSwitchorHostConnect Step9SetuptheHost HBAandDriverInstallationCompletethefollowingtasksoneachhostthatwillusethestoragesystem 1 Installthehostbusadapters HBAs inthehost Refertothe EMCFibreChannelHBAandDriverInstallationGuideand EMCFibreChannelHBA DriverReleaseNotesappropriateforyouroperatingsystem 2 ForaSANconfiguration connecteachHBAtotheappropriateswitchport 3 Foradirectattachconfiguration connecteachHBAtotheappropriateSPport 4 InstalltheHBAdriverandanyutilitiesfromtheHBAmedia ifappropriate oneachhost 5 SwitchZoneCreationRefertothedevice specificdocumentationprovidedwithyourFibreChannelswitch es tocompletethefollowing 6 Oneachswitchfabric createazoneforeachHBAandalltheSPportsthatyouwanttheHBAtoaccess UseWorldWidePortNames WWPNs tospecifytheHBAandtheSPportsforthezone Step9SetuptheHost HBAandDriverInstallation continued 7 InstallCLARiiONDriverExtension CDE softwareifCDEisavailableforyourhost andyourconfigurationrequiresit FC4700storagesystemssupportCDEinIBMAIX SunSolaris andMicrosoftWindowsNTandWindows2000environments ConfigurationswithonlyonehostHBArequireCDE 8 Activatethedriver Dependingonthehost youmayneedtorebootthehost Step9SetuptheHost NavisphereHostSoftwareInstallation1 IfthehosthasmultipleHBAsconnectedtothestoragesystemandNavisphereApplication TransparentFailover ATF isavailable installATF FC4700storagesystemssupportATFinAIX NovellSolaris WindowsNTandWindows2000environments 2 InstalltheNavisphereHostAgentandoptionalCLI 3 ActivatetheATFdevicesandHostAgentbyrebootingthehost 4 IfyouplantoinstallSnapViewsoftware installtheadmsnaphostmanagementutilitysoftware Step9SetuptheHost Step10CreateFC4700StorageGroup CreateaRAIDGroupRight clickstoragesystem Select CreateRAIDGroup inmenu Chooseeitherbasicoradvanceddialog Inadvanceddialog diskscanbeselectedmanually 2 BindaLUNInaRAIDGroup Step10CreateFC4700StorageGroup Right clickstoragesystemicon Inmenu select BindLUN Choosebasicoradvancedbinddialog Selectoptionsandclick Apply 3 AccessLogix Step10CreateFC4700StorageGroup Use DetailedView togetanoverviewoftheAccessLogixsetup Select DetailedView fromtheright clickmenuforthestoragesystem Alliconsareactive 4 TurningOnAccessLogixusingNavisphereManager Step10CreateFC4700StorageGroup Right clickstoragesystemiconandselect Properties Goto DataAccess tab Checkthe AccessControlEnabled checkbox Click OK Cannotbeunchecked 5 CreatinganddestroyingStorageGroupsusingManager Step10CreateFC4700StorageGroup Right clickstoragesystemiconandselect CreateStorageGroups Specifynameforstoragegroup MoveLUNstothe SelectedLUNs area CheckwhetherSGshouldbededicatedorsharable 6 ConnectingHostsUsingNavisphereManager Step10CreateFC4700StorageGroup Findstoragegroupin StorageGroups folderin Storage tab Right clickSGandselect ConnectHosts Movehostsbetweenareas Click OK or Apply 7 ChangingStorageGroupSettingsUsingNaviManager Step10CreateFC4700StorageGroup Right clickstoragegroupiconandselect Properties Makechangesinthepropertydialog Click OK or Apply 8 AddingorRemovingLUNsfromStorageGroupusingManager Step10CreateFC4700StorageGroup Inpropertydialogforstoragegroup click SelectLUNs MoveLUNsbetweenthetwoareas Click OK Click OK againinpropertiesdialog Step11CompletetheHostSetup RefertotheappropriateEMCNavisphereServerSoftwareSetupGuidetocompletethefollowingforeachhostthatwillusethestoragesystem 1 MaketheLUNsforeachhostavailabletothehost soperatingsystem Dependingontheoperatingsystem thismayinvolve LabelingandpartitioningLUNsMakingfilesystemsorcreatingvolumesonthepartitionsMountingthefilesystemsorvolumes 2 Ifhostsareclustered setuptheclusteringsoftwaretoworkwiththeFC4700 2 clicksessionSelect Properties CLARiiONCX600 InitializingtheCX600WithNavisphere6 1 Overview ConfigurationstepssimilartoFC4700withNavisphere6 05 noPSMsetup ServiceLaptopRequirements WindowsNTorWindows2000InternetExplorer5 5orNetscape6 0JavaRuntimeEnvironment1 3 1 01Navisphere6 1ManagementUI new SerialPPPConnectionSerialCable InitializingtheCX600 ConfiguretheServiceLaptopSettheStorageProcessorTCP IPParametersforSP AandSP BSettheArrayDateandTimeConfigureOperatingParametersCommitBaseSoftwarePerformNDUtoUpgradeorAddOptionalSoftwareComponentsConfigureRead WriteCacheCreateRAIDGroups StorageGroups BindLUNs andConnectHosts ConfiguringtheServiceLaptop InstalltherequiredServiceUINavispheresoftwareJava1 3 1 01Navisphere6 1WindowsUINavisphereCLICreateaWindowsdial upnetworkingPPPconnection ConfigureSP AIPParameters ConnectserialcabletoSP AEstablishaPPPnetworkconnectiontoSP AOpenInternetbrowserto http 192 168 1 1 setupSetnetworkpropertiesforSP AIPAddress Hostname SubnetMask Gateway PeerIPAddressApplysettings SP Areboots DisconnectserialcablefromSP A StorageProcessorNetworkSetupViaSerialPPPSession ConfigureSP BIPParameters ConnectserialcabletoSP BEstablishaPPPnetworkconnectiontoSP BOpenInternetbrowserto http 192 168 1 1 setupSetnetworkpropertiesforSP BIPAddress Hostname SubnetMask Gateway PeerIPAddressApplysettings SP Breboots DisconnectserialcablefromSP B RestartSP A sManagementServer Re connecttheserialcabletoSP AEstablishPPPsessiontoSP AOpenInternetbrowserto http 192 168 1 1 setupClickRestartManagementServerCheckYestorestarttheManagementServerWait60SecondsfortheManagementS
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年智能AI在影像诊断中的智能辅助诊断平台构建报告
- 2025年数字化设计与仿真在模具制造中的三维打印技术应用报告
- 云南省楚雄州双柏县2021-2022学年五年级上学期期中学业质量检测科学试题(含答案)
- 福建省莆田八中2026届高二化学第一学期期中质量检测试题含解析
- 2025年营养师考试专项训练试卷:冲刺阶段营养师心理辅导技巧训练
- 2025年导游资格证考试冲刺试卷:旅游线路设计与营销策略
- 2025年公务员考试行测言语理解专项试卷:逻辑判断与推理高分解析
- 2025年高中生物教师资格证考试教育理论知识专项训练试卷
- 2025年心理咨询师考试全真模拟试卷 心理评估专项强化
- 江苏省扬州市蒋王中学2026届化学高二上期中学业水平测试试题含解析
- 2025-2026秋季中小学第一学期升旗仪式22周校长演讲稿:第1周 烽火记忆照前路秋风为序启新程
- 2025年山东省菏泽市中考英语真题(无答案)
- 2025年高考山东卷化学试题讲评及备考策略指导(课件)
- 2022森林防火道路建设基本要求
- GB/T 25146-2010工业设备化学清洗质量验收规范
- GB/T 14825-1993农药可湿性粉剂悬浮率测定方法
- GB/T 12008.7-2010塑料聚醚多元醇第7部分:黏度的测定
- 文化政策与法规(第一课)
- 最全最好的血液净化课件资料
- 寻找消失的滇缅路:松山战痕课件
- 部编人教版《道德与法治》九年级上册教材介绍课件
评论
0/150
提交评论