免费预览已结束,剩余49页可下载查看
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
35kV送电线路改线设计学生:温肖龙 指导老师:李光辉 (三峡大学科技学院)摘要:本设计讲述了架空输电线路设计的全部内容,主要设计步骤是按架空输电线路设计书中的设计步骤,和现实中的设计步骤是不一样的。本设计包括导线、地线的比载、临界档距、最大弧垂的判断,力学特性的计算,定位排杆,各种校验,代表档距的计算,杆塔荷载的计算,接地装置的设计,金具的选取。在本次设计中,重点是线路设计,杆塔定位和基础设计。关键词: 导线 避雷线 比载 应力 弧垂 杆塔定位Abstract:In this text, it includes all the steps in of overhead power transmission line design, which is Accordance withthe design of overhead power transmission line , but it is not the same with the reality .this article discussed the conductor and the ground wires comparing load critical span .the maximum arc-perpendiculer judgement .mechanics propertys fixed position of shaft-tower. various checking .representative spans calculating. load ppplied on iron tower calculating. equipment used in the ground connection design. metal appliance choose .In this paper, it is the focal point of line design. iron tower design and fundament design.Key words:conductor overhead ground wire comparing load stress arc-perpendiculer fixed position of shaft-tower 2工程概况2.1工程的基本情况线路名称卫暗辛线原运行杆号P12(改线设计P1)至原运行杆号P21(改线设计P12)号杆改线工程起讫点起点卫暗辛线P12号杆,终点卫暗辛线P21号杆。设计电压35kv回路数单回长度2.276km冰区划分10毫米导线LGJ-95/20避雷线17-9.0-1370-A平均档距210米杆塔数量12基人力运距600米地形系数(%)高山大岭一般山地丘陵05050地质划分(%)普通土松砂石岩石203050交叉跨越(次)跨河流跨通讯线跨10kV跨低压线跨公路051322.2设计及验收相关规范66kV及以下架空电力线路设计规范(GB5006197)及其它有关技术规程,规范和规定。2.3设计线路主要参数项 目参 数电压等级35KV导线型号LGJ-95/20地线型号1791370A杆塔型式上字型铁塔基础型式阶梯式基础2.4气象条件本线路的气象条件为级,污秽等级为级。2.5地形地质条件本线路经过地区海拔在1000米左右,沿线地形以一般山地为主,其中一般山地占50%,丘陵占50%。根据现场实地勘测,线路沿线未发现滑坡、泥石流、地表塌陷及其他不良地质情况,全线地质情况为:普通土占20%,松砂石占30%,岩石占50%。3导线应力弧垂计算及曲线绘制3.1应力弧垂曲线的计算3.1.1整理计算用气象条件表3-1 气象区计算气象条件表项目气象气温()风速m/s冰厚mm最高气温+4000最低气温-1000最大风+10300最厚覆冰-5105内过电压+15150外过无风+1500外过有风+15100安装有风0100事故气象-1000年均气温+15003.1.2 LGJ-95/20 型导线参数和机械物理性能1. 导线的破坏应力为:2. 导线的最大使用应力为:3. 导线的年平均应力为:表3-2 LGJ-95/20 型导线参数和机械物理性能截面积A(mm2)导线直径d(mm)弹性系数E(MPa)温膨系数(1/)计算拉断力Tj(N)113.9613.877600018.5x10-637200计算质量q(kg/km)抗拉强度(MPa)安全系数k许用应力(MPa)年均应力(MPa)408.9310.1092.5124.04477.5273.1. 3.计算各气象条件下的比载(1)自重比载10,0=qgA10-3=35.18710-3MPa(2)冰重比载25,0=27.728bb+dA10-3=22.95710-3MPa(3)垂直总比载3(5,0)=1(0,0)+ 2(5,0)=58.14410-3 MPa/m(4)风压比载设=900,因导线外径d=13.87mm17mm,则风载体型系数sc=1.2,35kV线路,风载荷调整系数c=1.0,基本风压W=2/1.6。所以:外过电压 安装有风 风速为=10m/s时,查表得=1.0。所以:4(0,10)=dsin=9.128MPa/m内过电压 风速为=15m/s,查表得=0.75,所以:4(0,15)=dsin=15.404MPa/m最大风速 =30m/s时,基本风压为=2/1.6=562.5 Pa 计算强度时,查表得=0.75,所以:4(0,30)=dsin=61.615 MPa/m计算风偏时,查表得=0.61 4(0,30)=dsin=50.114 MPa/m覆冰风压比载风速V=10m/s,架空线覆冰时,架空线外径由d变为(d+2b),风载荷调整系数c=1.0,基本风压W=2/1.6。规程规定,无论线径大小,覆冰时的风载体型系数一律取为sc=1.2;计算强度时 f=1.0,所以5(5,10)=(d+2b)W10/Asin=15.709 MPa/m计算风偏时 f=0.75,所以5(5, 10)=(d+2b)W10/Asin=11.782 MPa/m无冰综合比载外过电压 安装有风时 6(0,10)=35.1872+9.128210-3=36.35210-3 MPa/m内过电压时6(0,15)=35.1872+15.4042=38.41110-3 MPa/m 最大风速,计算强度时 6(0,30)=35.1872+61.615210-3 =70.95410-3MPa/m最大风速,计算风偏时 6(0,30)=35.1872+50.114210-3=61.233 MPa/m(7)覆冰综合比载覆冰综合比载是架空线的垂直总比载和覆冰风压比载的矢量和。计算强度时 7(5,10)=58.1442+15.7092=60.22910-3 MPa/m计算风偏时 7(5,10)=58.1442+11.7822=59.32610-3 MPa/m表3-3各气象条件下导线比载总汇表 单位:MPa/m项目自重1(0,0)覆冰无风3(5,0)无冰综合6(0,10)无冰综合6(0,15)无冰综合6(0,30)(用于强度)无冰综合6(0,30)(用于风偏)覆冰综合7(5,10)(用于强度)覆冰综合7(5,10)(用于风偏)数据35.187 58.14436.352 38.41170.954 61.233 60.22959.326备注f=100sc=1.2f=0.75sc=1.2f=0.75sc=1.2f=0.61sc=1.2f=1.0sc=1.2f=0.75sc=1.23.1.4计算临界档距值,并判定有效临界档距和控制气象条件(1)可能控制条件有关的参数表3-4气象条件最低气温最大风速最厚覆冰年均气温(MPa/m)35.18710-370.95410-360.22910-335.18710-3o(MPa)124.044124.044124.04477.527/o(1/m)0.283710-30.569110-30.485510-30.453910-3气温t(C)-10+10-5+15/o从小至大编号adcb(2)按等高悬点考虑,计算有效临界档距的公式为若两种控制条件下的架空线许用应力相等,即则利用上式计算得各临界档距为lab=虚数lac=119.57mlad=189.7mlbc= 441.8mlbd=320.76mlcd=269.88m(3)有效临界档距判别表表3-5可能的控制条件a最低气温b年均气温c最厚覆冰d最大风速临界档距lab=虚数lac=119.57mlad=189.7mlbc= 441.8mlbd=320.76mlcd=269.88m由上表可以看 lcd=269.88m,lbd=320.76m为有效临界档距。实际档距llcd,最厚覆冰为控制条件;实际档距lcdllbd时,年均气温为控制条件;实际档距llbd时,最大风速为控制条件。3.1.5判定最大弧垂出现的气象条件用临界温度判定法判断最大弧垂发生的气象条件等高悬挂点架空线的状态方程式弧垂计算式运用临界温度判定法1l28j=3l28b所以j=13b以覆冰无风为第状态 临界温度为第状态 状态方程式13b-E12l224b2312=b-E32l224b2-Etj-tb解得上式临界温度为tj=tb+1-13bE取档距 l=50m 最厚覆冰为控制气象已 知 1=60.22910-3MPam t1=-51=124.044MPa覆冰无风时 tb=-53=58.144MPam求得 b=123.92MPa则tj=29.79tmax=40即最大弧垂发生在最高气温气象条件3.1.6计算架空线的应力和弧垂(1)已知条件及参数表3-6已知条件最厚覆冰年均气温最大风速 控制区间参数0269.88269.88320.76320.76tm()-5+15+10bm(mm)500Vm(m/s)10030m(10-3)60.22935.18770.954m(MPa)124.04477.527124.044(2)以各气象条件为待求条件 已知参数如下表表3-7参数待求条件最高气温最低气温年均气温事故外过有风外过无风内过电压tm()+40-10+15-10+15+15+15bm(mm)0000000Vm(m/s)000010015(10-3MPa/m)35.18735.18735.18735.18736.35235.18738.411参数待求条件安装覆冰无风 覆冰有风(强度)覆冰有风(风偏)最大风(强度)最大风(风偏) t()0-5-5-5+10+10b(mm)055500V(m/s)10010103030(10-3MPa/m)36.35258.14460.22959.32670.95461.233(3)LGJ95/20型导线应力弧垂计算表表3-8气象条件最高气温最低气温年均气温事故安装外过有风内过电压档距lr(m)0(MPa)fv(m)0(MPa)0(MPa)0(MPa)0(MPa)0(MPa)0(MPa)5061.490.18129.795.14129.7115.995.2195.3410063.140.69126.092.99126.0112.893.2693.7715064.911.52120.390.01120.3108.290.5991.6420066.432.64113.486.85113.4102.987.7889.42269.8868.064.7096.0977.52796.0989.3178.9381.38320.7666.496.8092.6077.52792.6087.6079.1481.9635065.818.1887.6975.1487.6983.9376.8679.8540064.9210.881.2972.0581.2979.1673.8877.0745064.2613.876.8369.8676.8375.7971.7675.0750063.7817.273.6868.2773.6873.3770.2173.60气象条件外过无风覆冰有风(强度)覆冰有风(风偏)覆冰无风最大风(强度)最大风(风偏)档距lr(m)0(MPa)fv(m)0(MPa)0(MPa)0(MPa)fv(m)0(MPa)0(MPa)5095.140.12124.044123.9123.90.14104.7103.810092.990.27124.044123.8123.50.58108.9106.015090.011.09124.044123.6123.11.32113.8108.720086.852.02124.044123.4122.62.37118.5111.4269.8877.5274.13118.1117.2116.04.56119.0109.4320.7677.5275.83120.3119.2117.86.35124.044113.035075.147.17118.5117.4115.87.68124.044112.440072.059.76115.9114.8113.110.3124.044111.445069.8612.7114.1112.3111.113.3124.044110.650068.2716.1112.6111.2109.416.6124.044110.13.1.7计算安装应力和百米弧垂,绘制安装曲线时,以档距为横坐标,弧垂为纵坐标,一般从最高施工气温至最低施工气温每隔10绘制一条弧垂曲线。应用状态方程式求解各施工气象(无风、无冰、不同气温)下的安装应力,进而求出相应的弧垂,结果如下表所示。表3-9档距(m)50100150200269.88温度()0(MPa)f100(m)0(MPa)f100(m)0(MPa)f100(m)0(MPa)f100(m)0(MPa)f100(m)4061.70.7163.60.6965.80.6767.60.6569.50.633074.80.5874.80.5874.80.5874.90.5974.80.582088.40.4986.90.5185.10.5283.20.5380.90.5410102.10.4399.60.4496.30.4692.60.4787.90.500115.90.38112.80.39108.30.4397.70.4595.80.4510129.80.34126.20.35120.70.36114.10.39104.50.42档距(m)320.76350400450500温度()0(MPa)f100(m)0(MPa)f100(m)0(MPa)f100(m)0(MPa)f100(m)0(MPa)f100(m)4068.10.6467.40.6566.60.6666.00.6765.60.673072.70.6170.90.6269.30.6368.20.6467.30.652076.70.5774.70.5972.30.6170.50.6269.20.631081.90.5379.10.5575.60.5873.00.6071.20.62087.70.5083.90.5279.20.5675.70.5873.40.501094.20.4789.40.4983.10.5378.80.5675.70.583.1.8导线的应力弧垂曲线和安装曲线见附图3-8与附图3-9。4地线应力弧垂计算及曲线绘制4.1.地线选择地线采用镀锌钢绞线 ,由于导线LGJ95/20小于LGJ185/30,所以地线选取1791370A。4.2应力弧垂曲线的计算4.2.1地线1791370A的参数和机械物理性能表4-1截面积A地线直径d弹性系数E温度膨胀系数计算拉断力Tj计算质量q抗拉强度p安全系数K许用应力0年均应力上限cp(2)()(MPa)(1/)(N)(/)(MPa)(MPa)(MPa)49.489.05900023.010-662300411.91196.142.5478.456299.0354.2.2计算地线的比载(1)自重比载1(0,0)=gqA10-3=81.63610-3 MPa/m冰重比载2(5,0)=27.728b(b+d)/A10-3=39.22710-3 MPa/m直总比载3(5,0)=r1(0,0)+r2(5,0)=120.86310-3 MPa/m风压比载。设=900,因导线外径d=9.0mm17mm,则风载体型系数sc=1.2,35kV线路,风载荷调整系数c=1.0,基本风压W=2/1.6。所以:外过电压 安装有风 风速为=10m/s时,查表得=1.0。所以:4(0,10)=dsin=13.641 MPa/m内过电压 风速为=15m/s,查表得=0.75,所以:4(0,15)=dsin=23.020 MPa/m最大风速 =30m/s时,基本风压为=2/1.6= 562.5Pa 计算强度时,查表得=0.75,所以:4(0,30)=dsin=92.082 MPa/m计算风偏时,查表得=0.61 4(0,30)=dsin=74.893 MPa/m覆冰风压比载风速V=10m/s,架空线覆冰时,架空线外径由d变为(d+2b),风载荷调整系数c=1.0,基本风压W=2/1.6。规程规定,无论线径大小,覆冰时的风载体型系数一律取为sc=1.2;计算强度时 f=1.0,所以5(5,10)=(d+2b)W10/Asin=28.799 MPa/m计算风偏时 f=0.75,所以5(5, 10)=(d+2b)W10/Asin=21.599 MPa/m无冰综合比载外过电压 安装有风时6(0,10)=81.6362+13.641210-3=82.76710-3 MPa/m内过电压时6(0,15)=81.6362+23.0202=84.82010-3 MPa/m 最大风速,计算强度时 6(0,30)=81.6362+92.082210-3 =123.0610-3MPa/m最大风速,计算风偏时 6(0,30)=81.6362+74.893210-3=110.78 MPa/m(7)覆冰综合比载覆冰综合比载是架空线的垂直总比载和覆冰风压比载的矢量和。计算强度时 7(5,10)=120.8632+28.7992=124.2510-3 MPa/m计算风偏时 7(5,10)=120.8632+21.5992=122.7810-3 MPa/m表4-2各气象条件下地线比载总汇表单位:10-3 MPa/m项目自重1(0,0)覆冰无风3(5,0)无冰综合6(0,10)无冰综合6(0,15)无冰综合6(0,30)(用于强度)无冰综合6(0,30)(用于风偏)覆冰综合7(5,10)(用于强度)覆冰综合7(5,10)(用于风偏)数据81.636 120.86382.767 84.820123.06110.28124.25122.78备注f=100sc=1.2f=0.75sc=1.2f=0.75sc=1.2f=0.61sc=1.2f=1.0sc=1.2f=0.75sc=1.24.2.3计算临界档距 判断控制条件(1)可能控制条件有关的参数表4-3气象条件最低气温最大风速最厚覆冰年均气温(MPa/m)81.63610-3123.0610-3124.2510-381.63610-3o(MPa)398.71398.71398.71299.035/o(1/m)0.20510-30.30910-30.31210-30.27310-3气温t(C)-10+10-5+15/o从小至大编号acdB(2)临界温度判定法判断最大弧垂发生的气象条件按等高悬点考虑,计算有效临界档距的公式为若两种控制条件下的架空线许用应力相等,即则利用上式计算得各临界档距为lab=虚数lac=454.9mlad=223.6mlbc= 1349.9mlbd=1143.0m lcd=虚数(3)有效临界档距判别表表4-4可能的控制条件a最低气温b年均气温c最大风速d最厚覆冰临界档距lab=虚数lac=454.9mlad=223.6mlbc= 1349.9mlbd=1143.0mlcd=虚数由上表可以看出 lbd=1143.0m为有效临界档距。当实际档距llbd时,年均气温为控制条件;当实际档距llbd时,最厚覆冰为控制条件。4.2.4判定最大弧垂出现的气象条件临界温度判定法判断最大弧垂发生的气象条件等高悬挂点架空线的状态方程式弧垂计算式运用临界温度判定法1l28j=3l28b所以j=13b以覆冰无风为第状态 临界温度为第状态 状态方程式13b-E12l224b2312=b-E32l224b2-Etj-tb解得上式临界温度为tj=tb+1-13bE取档距 l=50m 年平均温为控制气象已 知 1=81.63610-3MPam t1=+151=299.035MPa覆冰无风时 tb=-53=120.863MPam求得 b=326.5MPa则tj=73.08tmax=40即最大弧垂发生在覆冰无风气象条件4.2.5计算各气象条件的应力和弧垂(1)已知条件及参数表4-5已知条件年均气温最厚覆冰 控制区间 参数01143.01143.0tm()+15-5bm(mm)05Vm(m/s)010m(10-3)81.636124.25m(MPa)299.035398.71(2)以各气象条件为待求条件 已知参数如下表表4-6参数待求条件最高气温最低气温年均气温事故外过有风外过无风内过电压tm()+40-10+15-10+15+15+15bm(mm)0000000Vm(m/s)000010015(10-3MPa/m)81.63681.63681.63681.63682.76281.63684.820参数待求条件安装覆冰无风 覆冰有风(强度)覆冰有风(风偏)最大风(强度)最大风(风偏) t()0-5-5-5+10+10b(mm)055500V(m/s)10010103030(10-3MPa/m)82.762120.863124.25112.78123.06110.78(3)1791370A地线应力弧垂计算表表4-7气象条件最高气温最低气温年均气温事故安装外过有风内过电压档距lr(m)0(MPa)fv(m)0(MPa)0(MPa)0(MPa)0(MPa)0(MPa)0(MPa)50265.39.61332.8229.035332.8319.3299.0299.1100265.60.38332.6229.035332.6319.2299.1299.2150266.20.86332.2229.035332.2318.9299.2299.4200266.91.53331.6229.035331.6318.6299.3299.6250267.92.38330.9229.035330.9318.3299.4299.9300268.93.41330.0229.035330.0317.8299.5300.2350270.14.63329.1229.035329.1317.4299.6300.6400271.36.02328.0229.035328.0316.9299.7300.9450272.67.58326.9229.035326.9316.4299.8301.3500273.99.31325.8229.035325.8315.8300.0301.8气象条件外过无风覆冰有风(强度)覆冰有风(风偏)覆冰无风最大风(强度)最大风(风偏)档距lr(m)0(MPa)fv(m)0(MPa)0(MPa)0(MPa)fv(m)0(MPa)0(MPa)50299.0358.53326.6326.5326.60.12306.4306.2100299.0350.34327.8327.3327.70.46307.9307.2150299.0350.77329.9328.6329.41.03310.4308.8200299.0351.36332.6330.3331.91.82313.6310.9250299.0352.13335.8332.4334.82.82317.5313.5300299.0353.07339.3334.8337.94.02321.7316.4350299.0354.18343.2337.4341.55.42326.2319.6400299.0355.45347.2340.1345.17.00330.9322.8450299.0356.91351.3342.9348.88.77335.6326.2500299.0358.53355.5345.8352.610.7340.4329.54.2.6计算安装应力和百米弧垂,绘制安装曲线时,以档距为横坐标,弧垂为纵坐标,一般从最高施工气温至最低施工气温每隔10绘制一条弧垂曲线。应用状态方程式求解各施工气象(无风、无冰、不同气温)下的安装应力,进而求出相应的弧垂,结果如下表所示表4-8档距(m)50100150200250温度()0(MPa)f100(m)0(MPa)f100(m)0(MPa)f100(m)0(MPa)f100(m)0(MPa)f100(m)40265.30.38265.70.38266.30.38267.20.38268.30.3830278.70.37279.00.37279.40.37279.90.36280.60.3620292.30.35292.40.35292.60.35292.80.35293.00.3510305.80.33305.70.33305.70.33305.60.33305.60.330319.30.32319.20.32319.00.32318.70.32318.30.32-10332.90.31332.60.31332.30.31331.80.31331.10.31档距(m)300350400450500温度()0(MPa)f100(m)0(MPa)f100(m)0(MPa)f100(m)0(MPa)f100(m)0(MPa)f100(m)40269.50.37270.80.37272.20.37273.50.37274.90.3730281.30.36282.10.36283.00.36283.80.35284.80.3520293.40.35293.70.35294.10.35294.50.35294.90.3510305.50.33305.50.33305.40.33305.30.33305.20.330317.90.32317.40.32317.00.32316.40.32315.80.32-10330.40.31329.50.31328.60.31327.60.31326.60.314.2.7 地线的应力弧垂曲线与安装曲线见附图4-7与附图4-8。5杆塔定位定位即在已经选好的线路路径上,测绘出平断面图并配置杆塔的位置。杆塔定位时要尽量少占耕地良田,避开水文、地质条件不良的地段,需考虑施工的方便性。档距配置时要最大限度地利用杆塔强度,相邻档档距大小不宜相差太大,以免增加不平衡张力,另外应尽量避免出现孤立档。杆塔选用尽可能地选用最经济的杆塔型式和高度,尽量避免特殊设计杆塔。5.1塔型选择 本段线路属山区,考虑到防雷要求,电压等级,经济性,用上字型排列,因此选用35kV上字型转角杆塔和上字型直线杆塔。因线路所在地区为雷电活动强烈区,根据规程应架设地线,此段线路沿全线架设单根地线。另外山区施工困难不易打拉线,宜采用自立式铁塔。由规程取居民区的导线对地安全距离为7.0m。5.2确定杆塔的定位高度为便于检查导线各点对地的距离,定位时在断面图上绘制的弧垂曲线并非导线的真实高度,而是导线的对地安全距离,即将导线悬挂点向下移动一段对地距离后画出的悬垂曲线,只要该线不与地面相交,即满足对地距离的要求。此时的导线悬挂点对地高度,称为杆塔定位高度。对直线型杆塔,杆塔定位高度对耐张型杆塔,杆塔定位高度 式中 H杆塔的乎称高度,即杆塔下横担的下弦边线到地面的垂直距离; d导线的对地安全距离;悬垂绝缘子串的长度; 考虑勘测、设计和施工误差,在定位时预留的限距裕度,一般档距200m以下取0.5m,700m以下取1.0m,大于700m以及孤立档取1.5m,大跨越取23m。表5-1导线对地面的最小距离线路经过地区标称电压(kV)35110154220330500居民区7.07.58.514非居民区6.06.57.510.511交通困难地区5.05.56.58.5表5-2导线与山坡、峭壁、岩石之间的净空距离线路经过地区标称电压(kV)35110154220330500步行可以到达的山坡5.05.56.58.5步行不能到达的山坡、峭壁、岩石3.04.05.06.55.3定位弧垂模板的制作 为便于按导线对地距离及对障碍物的距离要求配置塔位,可事先按导线安装后的实际最大弧垂形状,制成弧垂模板以比量档内导线各点对地及对障碍物的垂直距离5.3.1弧垂曲线模板及其选用杆塔定位要保证导线任一点在任何情况下的对地距离,为此需依据导线架设后的最大弧垂气象时的悬链线形状,比量档内导线各点对地及跨越物的垂直距离,来配置杆塔位或杆塔高度。为方便起见,导线最大弧垂时的形状常制作成模板。坐标原点选取在弧垂最低点时,架空线的悬链线方程为:令,则上式可简化为:其中:导线最大弧垂时的比载; 导线最大弧垂时的应力; 弧垂模板值。档距为200=35.18710-3 MPa/m0=66.43MPa即可知 K=20=35.18710-3266.43=2.64810-4取不同的值可以得到一组定位曲线。因此可以按照不同的K值,以x为横坐标,y为纵坐标,采用与纵断面图相同的纵横比列作出一组弧垂曲线,并将其刻制在透明赛璐珞版上,就形成通用弧垂曲线模板。为简便起见,只在得到相应的代表档距后,查K值曲线,选取弧垂曲线模板。由于各耐张段的代表档距不同,导线最大弧垂时的应力和控制气象条件不同,对应的弧垂模板K值也不同。为了方便定位时选择模板,可事先根据不同的代表档距,得到导线最大弧垂时的应力和比载,算出相应K值,绘制成模板K值曲线。表5-3 LGJ95/20型导线最大弧垂时的K值档距(m)50100150200269.88320.76350400450500K10-42.8612.7862.7102.64825852.6462.6732.7102.7382.7585.4排杆5.4.1杆塔排定根据给定的平断面图以及已有线路的因素考虑,定位桩K0和J1之间为耐张段1,耐张段长度为160m,均为转角塔。桩J1、J2之间为耐张段2,长度为252m,且均为转角塔。前面两耐张段均为孤立档。桩J2和J3处是耐张段3长度为343m,两处均为转角塔,中间排一个直线塔。桩J3和J4、J4和J5均为转角塔,即为孤立档(耐张段4与耐张段5)。桩J5和J6处,由于地形、地貌原因等,排塔和桩J2、J3处类似,采用3塔形式,为耐张段6。桩J6与K1均为转角塔,为耐张段7长为579m,由于耐张段较长,中间排两个直线塔。因此,根据弧垂曲线模板排杆如下第1档耐张段:l1=160m第2档耐张段:l2=252m第3档耐张段:l3=273m l4=70m第4档耐张段:l5=219m第5档耐张段: l6=237m第6档耐张段: l7=136m l8=309m第7档耐张段: l9=265m l10=154ml11=160m5.4.2模板K值校验估计耐张段代表档距lr:耐张段7:先假设代表档距为200米,在最大弧垂下=35.18710-3 MPa/m0=66.43MPa即可知 K=20=35.18710-3266.43=2.64810-4此耐张段的杆塔为P9、P10、P11、P12号杆塔,用1
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 代理资质年检合同范本
- 2025年工业设备故障诊断模型设计指南报告
- 培训店长合同范本
- 合作投资建厂合同范本
- 土地佣金居间合同范本
- 电工入职合同范本
- 画室教师协议合同范本
- 电商平台仓库管理优化方案与实施计划
- 基层合理用药管理现状思索教案
- 高中数学《信息数学》教案(2025-2026学年)
- 机械设备维修合作协议
- 信息素养通识教程:数字化生存的必修课学习通超星期末考试答案章节答案2024年
- 人教版九年级上册数学期中考试试卷带答案详解
- 国家职业技术技能标准 4-07-05-03 智能楼宇管理员 人社厅发2018145号
- 相反国课件-大班
- 光声成像诊断肝脏疾病
- 大话机器人智慧树知到期末考试答案2024年
- 轮椅运用和床椅转移课件
- 无期限的六合公式汇编
- 基层应急能力提升课件培训
- 全国优质课一等奖中职《就业与创业指导》课件
评论
0/150
提交评论