9E gas turbine turning failure analysis and processingThe Dongguan the Shennengyuan ZhangYang Electricity Co., Ltd. Li WeihuaAbstract: This article describes a few cases 9E gas turbine turning failure phenomenon, analysis and reasons given for may cause failure of turning, and given the failure of prevention and handling approaches. Keywords: 9E gas turbine, to deal with turning failure The gas turbine combined cycle generating unit has many fine characteristics, characteristic of the starting fast is one of the most important performance of the daily start and stop cycling unit. 9E gas turbine cooler and operation before the firing process, which we call turning. Turning failure, the unit from the normal stop cannot be assured, the normal overhaul faults elimination it is difficult to carry out. Failure of gas turbine turning Reason Analysis, and using appropriate methods to solve handling, it is very important. A) Definition of turning failure following a fault phenomenon, called turning failure.(1) Combustion engine during deceleration, when the speed reaches the turning speed, turning into losing gas turbine speed down to zero speed;(2) In the case of gas turbine in the process of low disk without instruction issued stop turning, the gas turbine speed down to zero speed;(3) Gas turbines stop turning to zero speed, in the case of start command is issued turning gas turbine remains zero speedB) The various causes of the failure of turning the main reason for turning failure can be divided into two categories:First class: due to the friction between the gas turbine rotor and stator the polishing the torque greater than the turning torque, making the turning gear stop in the middle or from zero turning failed. Such failure is caused by the following conditions.(1) Compressor / turbine rotor blade tip and the cylinder wall scuffing, scraping cylinder phenomenon;(2) A compressor / turbine top of the stator blades and the rotor hub outer wall exists abrasion;(3) The turbine moving blade contact Mount Sassafras exists between the roots and the top of the nozzle seal teeth;(4) gas turbine rotor journal and bearing between Mount Sassafras resistance increases, which may be due to damage to the bearing, bearing concentricity deviation from the design value, the rotor journal the concentricity deviation from the design value, bearing oil supply shortage orlow lube oil temperature and other causes;(5) jacking oil system is put from the top of the generator journal height is lower than the standard value, making the generator journal and bearing between Mount Sassafras resistance increases. Second category: power end starter motor (88CR) of low speed Turning gear (88TG) or failure of the hydraulic torque converter (HM1), makes the turning torque is lower than the design value, the turning cannot be normal.C) Turning failure cases1) 2004-07 early 3 # gas turbine load rejection test run was made after 30 minutes, the trip occurred for other reasons in the base-load state, low disk into losing speed dropped to 3.3% SPD, straight down to zero speed. The next day after inspection and manual / hydraulic disc car a few laps later, successfully put into turning. Analysts believe that the main reason for the failure of two, the first gas turbine is running in the basic load state shorter time, expansion of the rotor and the stator imbalance, the expansion of the rotor is greater than the stator; second is when the door opening between the turbine significantly faster cylinder cooling contraction; 2:00 caused friction between the rotor blades and stator cylinder wall, and the moment of resistance is greater than the turning torque.2) 2004-07 early # 3 gas turbine 40MW load hours after normal shutdown when the speed dropped to 3.3% SPD, low disk into losing speed straight down to zero speed. Reach zero speed for about 20 minutes, reverted to the the 88 CR start the motor, the gas turbine perform automatically from the cast plate car program, re-turning normal input. The reasons of the failures and examples are basically similar.3) 04-12-14, at 05:40,3 # in the morning gas turbine rinsed with water after the first water rinse, stop turning to do maintenance work, after 70 minutes, from zero cast and turning failed. turning manual / hydraulic turning 180 and throw the is not successful; disk and then turn 450 , the success of the cast and turning. The failure appears, we feel more accidents, because before this # 3 gas turbine experienced a dozen times successfully stop turning / zero from the cast plate car. The cause of the failure of the plate of the car to be investigation.4) 2005-01-02 night, the end of the minor repair work, # 3 gas turbine stops turning after 55 hours, from zero cast and turning failed. To the early morning of 2005-01-03, manual / hydraulic turning 450 , and successfully put into turning. The cause of the failure of the plate of the car to be investigation.5,1 # gas turbine after the shutdown normal input and low disc, then turn off after no more than one hours, the operating personnel in the inspection found in the turbine room exception scraping grinding sound, so open the door to enter the check after about 10 minutes, burningthe rotor has stopped rotating. After 13 hours by manual / hydraulic turning 450 , after zero-turning invest successfully. Analysts believe that the main reason of the failure is due to the gas turbine cylinder and rotor uneven cooling and contraction after the shutdown, the compressor / turbine rotor blade tip and the cylinder wall scuffing, scraping cylinder phenomenon, Mount polishing the moment of resistance is greater than the torque of the turning the last disc car down.turning failure examples through the example of the five turning failure inductive analysis, you can know the compressor / turbine rotor blade tip and the cylinder wall scuffing, scraping cylinder phenomena turning failure downward deflection of the natural, generally occurs after flameout of the shutdown process of deceleration and turning; experience from previous open cylinder check under Bangang wall scuffing probability, because the rotor heat up Wen Hougang decreased increases, the rotor blade easily come into contact with the inner wall of the next Bangang. Stop turning from zero turning failed, the reasons are more complex, involving many factors; start the motor power end (88CR), the torque converter (HM1), gas turbine rotor, stator, bearing and journal bearing, generator the jacking height of the oil pressure / temperature, any link failure will cause the turning failure. gas turbine start-ended input tray car unit rotor torque can not overcome the static friction torque, is the main reason for the failure of the zero-plate cars. The following is a list of the # 1, # 3 machine turning parameter table.# 1, # 3 machine turning parameter tableUNIT # Idling time LowdiskspeedHighdisk speedTMGV Opening Zero-turningperformance1# GT12 min 15 sec 4.0%SPD 24.1%SPD Higher value:63 Lower value:43 Anormalzerofromturning3# GT 12 min 18sec3.7%SPD 22.1%SPD Higher value:68Lower value:43 Not normallyzerosinceturning.Aftera certainpoint of viewofthe manual/hydraulicdisccar,to get ready forturning.Throughthistable informationanalysis,draw the following conclusions:1,1#3# gas turbine idling timebasicallyequal to2 sets ofgas turbineintherangeofidlingthe dragtorqueis basically the same;2, ifthetwosetsof gas turbineof the torque converterperformance intact,and# 3ofthe dragofthegas turbinerotortorqueisgreater than# 1inthelow / highdisc state,agas turbine;Inthelow/highdiskstate,ifthemoment of resistanceand1 #3#gas turbinerotorsufferedbasically the same,you canthat3#machinetorque converterinsufficient output;4,3#Barringgas turbinefrom zero, TMGVangleof68 ,# 1the machine5,butstill notsmoothfrom thedisk,theDescription3#machinerotorstatic frictionSassafrasthan1 #bigmore;5, in thezerospeed condition,combustion engine3 #manual /hydraulic disccar,allowsthepad surfacetocreateafilm,to improvetheunit eachbushlubricating propertiessuch thattherotor journalstaticfrictionforce reductionin thecrankingtorquethe sa
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 输煤技术考试题及答案
- 防汛救灾宣传课件
- 纸制品公司劳动协议
- 企业员工自愿放弃社保协议书9篇
- 跨国教育法律与政策研究-洞察及研究
- 收学员合同7篇
- 脚手架钢管出租合同6篇
- 成分配伍分析-洞察及研究
- 部队安全培训体会课件
- 河北省保定市2024-2025学年高二上学期期末联考生物试卷(B卷)(含答案)
- 部编版六年级语文上册重点难点解析
- 2024年中国人寿集团公司招聘笔试参考题库含答案解析
- 压 实 度 试 验 记 录 表
- GA/T 1069-2013法庭科学电子物证手机检验技术规范
- 新版药品管理法培训培训课件
- 单位线法推求流域出口洪水过程工程水文学课件
- 高一上学期月考语文试题(八套)
- 幼儿园组织与管理讲座课件
- 2021年新疆第二医学院辅导员招聘试题及答案解析
- 淤泥换填渣石方案
- 2022标准方法验证报告(安检)
评论
0/150
提交评论