ACONIS-2000 Power Management System Parameter ListACONIS-2000 PMSParameter List1 ACONIS2000 PMS Parameters CategoryP. NoDescriptionUnitDG1DG2DG3RemarksBus Bar settingP001Bus Bar Nominal VoltageV450P002Bus Bar Nominal FrequencyHz60Generator settingP003G/E Nominal PowerkW900900900P004G/E Nominal CurrentA144314431443Start Control settingP005Start Command Pulse Widthsec15P006Control Try (Attempts)Num1Fixed 1 ItemStop Control settingP007Max Unloading Timesec60P008CB Open at Load%10P009Idle Running Timesec60P010Stop Command Pulse Widthsec10Synchronize Control settingP011Synchronize Timesec60P012Delta FrequencyHz0.2P013Delta VoltageV23P014CB Make Timemsec40P015Min Pulse Timemsec500Auto Governor Control settingP016Frequency Dead BandHz0.2P017Frequency Prop BandHz2P018Active Load Dead BandKw15P019Active Load Prop Band%50P020Cycle Timesec3P021Min Pulse Timesec0.5P022Max Pulse Timesec1.5Heavy Load demand Auto StartingP023Load High Limit step 1%90P024Load High Delay step 1sec10P025Current High Limit step 1%190P026Current High Limit step 1sec-1Not usedCategoryP. NoDescriptionUnitDG1DG2DG3RemarksHeavy Load demand Auto StartingP027Load High Limit step 2%95P028Load High Delay step 2sec10P029Current High Limit step 2%195P030Current High Limit step 2sec-1Not usedP031Load High Limit step 3%100P032Load High Delay step 3sec3P033Current High Limit step 3%200P034Current High Limit step 3sec-1Not usedLight Load demand Auto StoppingP035Max allowed Load after Low Load Stop%70P036Low Load stop delaySec600Load Demand Preferential Trip Group 1P037Load High Limit group 1%100PT 1P038Load High Delay group 1sec5P039Current High Limit group 1%100P040Current High Limit group 1sec5P041Frequency Low Limit group 1Hz58.5P042Frequency Low Limit group 1sec5Load Demand Preferential Trip Group 2P043Load High Limit group 2%100PT 2P044Load High Delay group 2sec10P045Current High Limit group 2%100P046Current High Limit group 2sec10P047Frequency Low Limit group 2Hz58.5P048Frequency Low Limit group 2sec10Light Fault Bus Bar Abnormal AlarmP049Low Voltage LimitV427.5P050Low Voltage Delaysec5P051High Voltage LimitV472.5P052High Voltage Delaysec5CategoryP. NoDescriptionUnitDG1DG2DG3Remarks Light Fault Bus Bar Abnormal AlarmP053Low Frequency LimitHz57P054Low Frequency Delaysec5P055High Frequency LimitHz63P056High Frequency Delaysec5DG Protection setting (ACB Trip)P057Low Low Voltage LimitV31570%P058Low Low Voltage Delaysec1P059High High Voltage LimitV585.5130%P060High High Voltage Delaysec5Light Fault Bus Bar Abnormal AlarmP061Low Low Frequency LimitHz5490%P062Low Low Frequency Delaysec10P063High High Frequency LimitHz66110%P064High High Frequency Delaysec3Light Fault Bus Bar Abnormal AlarmP065Current High Limit%150P066Current High Delaysec30P067Reverse Power Limit%-10P068Reverse Power Delaysec5Aux #1. DO Control settingP069Aux. DO #1 Function Code-1231See AXO TableP070Aux. DO #1 Function Parameter #1-18090180P071Aux. DO #1 Function Parameter #2-212P072Aux. DO #1 Function Parameter #3-030Aux #2. DO Control settingP073Aux. DO #2 Function Code-101See AXO TableP074Aux. DO #2 Function Parameter #1-1800750P075Aux. DO #2 Function Parameter #2-203P076Aux. DO #2 Function Parameter #3-000Aux #3. DO Control settingP077Aux. DO #3 Function Code-002See AXO TableP078Aux. DO #3 Function Parameter #1-0029P079Aux. DO #3 Function Parameter #2-000P080Aux. DO #3 Function Parameter #3-000CategoryP. NoDescriptionUnitDG1DG2DG3RemarksAux. DI #1P081Aux. DI #1 Function Code-202Aux. DI #2P082Aux. DI #2 Function Code-202Aux. DI #3P083Aux. DI #3 Function Code-0022 System / Hardware ConfigurationCategoryP. NoDescriptionUnitDG1DG2DG3RemarksHardware settingP084GE Running Voltage Build up Dead BandV30P085GE Stable Running Delay Timesec1P086GE Stop by user Load Shift%85P087Short Parallel Running(GE Abnormal)sec0FixedAux #3. DO Control settingP088Preferential Trip Output Off Delay Timesec1FixedP089GE Idle Run & Wait Time after Blackoutsec0FixedP090CT Ratio (ex400 = 2000/5A)-400400400FixedInternal Control settingP091GE Running Voltage Nominal Voltage%95P092GE Stopped Voltage Nominal Voltage%10Heavy Consumer Block SetupP093Consumer Block accept Load Sharing%10P094Consumer Block accept Signal off Delaysec5Synchronize SetupP095Synchronize ACB Close Degree OffsetDeg0P096Synchronize ACB Close Dead BandDeg8Unbalance Load Sharing SetupP097Set Point of Master DGs Load%70P098Set Point of Slave DGs Load%30P099Master/Slave DG Changeover Timemin0System ConfigurationP100Number of GCENum3P101Index of Bus Tie PositionNum20=None / 1=DG1, BT, DG2, DG3 / 2=DG1, DG2, BT, DG3CategoryP. NoDescriptionUnitDG1DG2DG3RemarksMeter Calibration FactorP102Gen. Voltage Meta Calibration FactorNum100010001000(x 1000) Time ValueP103Gen. Current Meta Calibration FactorNum100010001000P104Gen. Power Meta Calibration FactorNum100010001000P105Bus. Voltage Meta Calibration FactorNum100010001000P106Current Zero Cut Off Meta CalibrationNum000Extra ParameterP107ACB Close when Black Out Controlsec0Max 10secExtern System Communication SetupP108XIC Configure ValueNum0P109XIC ReservedNum10x 100ms3 User Custom ParameterCategoryP. NoDescriptionUnitDG1DG2DG3RemarksCustom Function ParametersP111Light Load Cancel (0=No, 1=Yes)0/10P112GDP Buzzer Sounding (0=Off, 1=On)0/114 Reserved ParametersCategoryP. NoDescriptionUnitDG1DG2DG3RemarksSystem Reserved ParametersP120Program Build Number in EEPNum806FixedP121Program Version Number in EEPNum2300FixedP122GCE Node ID Number in EEPNum012FixedP123Reserved for Operator Info (Password)Num0821Hull NoP124PMS Software Version in programNum1.1Fixed5 AXO TableDescriptionFunction CodeParameter ValueRemarkAux. DO Function DisableCode = 0Parameter #1Not UseParameter #2Not UseParameter #3Not UseHeavy Consumer BlockCode = 1Parameter #1Request Minimum PowerParameter #2Request Minimum Number of Parallel Running DGParameter #3Not UsePMS Status OutputCode = 2Parameter #1Status Code NumberParameter #2Invert Flag (0 = Non Invert, 1 = Invert)Parameter #3Off Delay Time (sec)Where, Status Code (Parameter #1) as bellows.0 : PMS Ready1 : CB Open2 : GE Run3 : CB Closed4 : Alarm5 : Manual6 : Automatic7 : Local (Control blocked)8 : 1st Stand by9 : 2nd Stand by10 : GE Starting11 : GE Stopping12 : Synchronizing13 : Stand by GE Start14 : Start Failure15 : Stop Failure16 : CB Non Closed / Synchro Fail17 : GE Shut Down18 : Reverse Power Trip19 : ACB Abnormal Trip20 : Over Current Trip21 : Preferential Trip 122 : Preferential Trip 223 : Bus Bar Voltage Low24 : Bus Bar Voltage High25 : Bus Bar Frequency Low26 : Bus Bar Frequency High27 : Heavy Load Condition28 : Light Load Condition29 : Light Load CancelACB Abnormal Trip Status OutputCode = 3Parameter #1UnusedIn one or more DGParameter #2Invert Flag (0 = Non Invert, 1 = Invert)Parameter #3Off Delay Time (sec)INFO : ACB ABNORMAL / ENGINE SHUT DOWN / OCR / SHORT CIRCUIT / REVERSE POWER TRIPDescriptionFunction CodeParameter ValueRemarkPMS Pseudo Alarm OutputCode = 4Parameter #1Pseudo Alarm Code NumberIn one or more DGParameter #2Invert Flag (0 = Non Invert, 1 = Invert)Parameter #3Off Delay Time (sec)Where, Pseudo Alarm Code (Parameter #1) as bellows.0 : Common Alarm1 : Auto Standby Start2 : Start Failure3 : Stop Failure4 : ACB Non Closed5 : Synchro Fail6 : Engine Shut Down7 : Reverse Power Trip8 : ACB Abnormal Trip9 : Over Current Trip10 : Preferential Trip 111 : Preferential Trip 212 : Bus Bar Voltage Low13 : Bus Bar Voltage High14 : Bus Bar Frequency Low15 : Bus Bar Frequency HighGenerator Abnormal OutputCode = 5Parameter #1Unused (Default = 0)Not AvailableParameter #2Invert Flag (0 = Non Invert, 1 = Invert)Parameter #3Off Delay Time (sec)Unbalance Load Control Status OutputCode = 6Parameter #1Unused (Default = 0)Not AvailableParameter #2Invert Flag (0 = Non Invert, 1 = Invert)Parameter #3Off Delay Time (sec)Total Available Power % ConditionCode = 21Parameter #1Total Available Power % LimitNot AvailableParameter #20 = “”Parameter #3Off Delay Time (sec)Total Available Power kW ConditionCode = 22Parameter #1Total Available Power kW LimitNot AvailableParameter #20 = “”Parameter #3Off Delay Time (sec)Total Used Power % ConditionCode = 23Parameter #1Total Used Power % LimitNot AvailableParameter #20 = “”Parameter #3Off Delay Time (sec)Total Used Power kW ConditionCode = 24Parameter #1Total Used Power kW LimitNot AvailableParameter #20 = “”Parameter #3Off Delay Time (sec)DescriptionFunction CodeParameter ValueRemarkSingle DG Available Power % ConditionCode = 25Parameter #1Single DG Available Power % LimitNot AvailableParameter #20 = “”Parameter #3Off Delay Time (sec)Single DG Available Power kW ConditionCode = 26Parameter #1Single DG Available Power kW LimitNot AvailableParameter #20 = “”Par
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年天文漫谈题目及答案初中
- 丽江古城翻译真题及答案
- 社区网格员考试试题及答案
- 混凝土搅拌工高级模拟练习题含答案
- 2025年手卫生题库及答案
- 2025年电工基础题目及答案
- nr考试复习测试有答案
- 有氧运动直播题目及答案
- 楼顶工程防水补漏方案(3篇)
- 《电子测量原理简明教程》-6章成本法发送习题答案
- 物资采购材料管理办法
- 河北省琢名小渔名校联考2025-2026学年高三上学期开学调研检测数学(含答案)
- 全科医学的基本原则和特点课件
- 国家综合性消防救援队伍消防员管理规定
- 医药公司新员工考评表
- 生态农庄设计规划课件
- 《工程制图完整》课件
- 互换性与测量技术基础总复习题与答案
- 预防校园欺凌主题班会课件(共36张PPT)
- 北京工业地产工业园区调研报告
- 脑室和脑池解剖
评论
0/150
提交评论