EN71-3方法确认.doc_第1页
EN71-3方法确认.doc_第2页
EN71-3方法确认.doc_第3页
EN71-3方法确认.doc_第4页
EN71-3方法确认.doc_第5页
已阅读5页,还剩6页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

Bureau Veritas Consumer Products (G.Z.) Co.Ltd 广州立德技术检测有限公司 Linearity (线性)(For ICP-OES)(AN-0160)1 Scope(目的)The purpose of this validation is to estimate the linearity of Soluble elements for EN71-3(ISO8124/ASTM F963-2003) with ICP-OES.本实验目的是来确认用ICP测定可迁移元素的线性。2 Procedure(过程) 2.1 Prepare a series of standard solutions as below: 0.1mg/L,0.2 mg/L,0.4 mg/L,1.0 mg/L,2.0 mg/L for As,Hg,Sb,Se 0.5mg/L,1.0 mg/L,2.0 mg/L,5.0 mg/L,10.0mg/L for Ba,Pb,Cd,Cr 配制一系列的标准溶液如下: 砷,汞,锑,硒为0.1mg/L,0.2 mg/L,0.4 mg/L,1.0 mg/L,2.0 mg/L 钡,铅,铬,镉为0.5mg/L,1.0 mg/L,2.0 mg/L,5.0 mg/L,10.0mg/L 2.2 Analyze the solutions as samples with ICP-OES. 用ICP来分析上述溶液。 2.3 Calculate the correlation coefficient (R) with minimum requirement of R0.995. 检验其标准曲线的相关系数(R)达到最低要求:R0.995。3 Results(结果)The linearity of As,Hg,Sb,Se ,Ba,Pb,Cd,Cr in 0.07NHCLAs,Hg,Sb,Se ,Ba,Pb,Cd,Cr在0.07N HCL中的线性范围Concentration of As standard working solutions (ppm)Intensity(c/s)Concentration of Ba standard working solutions (ppm)Intensity(c/s)0.1163.8320.5621730.2304.49211203780.4611.61224333111470.58558303322960oncentration of Cd standard working solutions (ppm)Intensity(c/s)Concentration of Cr standard working solutions (ppm)Intensity(c/s)0.538905.70.535531.2175553.9170354.221528072141176537499553478591072301010650584Concentration of Pb standard working solutions (ppm)Intensity(c/s)Concentration of Hg standard working solutions (ppm)Intensity(c/s)0.52264.640.1454.52114415.190.2887.70528858.630.41738.74521858.914421.651043296.328757.17Concentration of Sb standard working solutions (ppm)Intensity(c/s)Concentration of Se standard working solutions (ppm)Intensity(c/s)0.1255.790.1154.0190.2462.1930.2281.5010.4879.1910.4564.16912138.6511407.6624254.2322868.314 Conclusion(结论).The calibration curve is linear with R0.995 for Ba,Pb,Cd,Cr from 0.5ppm to 5ppm; As,Hg,Sb,Se from 0.1ppm to 2.0ppm.最终确认在0.07N盐酸中的砷,汞,锑,硒其线性范围0.1ppm到5ppm,钡,铅,铬,镉其线性范围0.05ppm到10ppm均达到R0.995。 注:根据CPSD-AN-00003-MTHD要求,现行使用砷,汞,锑,硒0.2ppm,0.4ppm,1.0ppm和钡,铅,铬,镉1.0ppm,2.0ppm,5.0ppm作为校准工作曲线。Instrument detection limit(仪器检出限)1 Scope(目的)The purpose of this validation is to determine the instrument detection limit (IDL)of soluble elements for EN71-3(ISO8124/ASTM F963-2003) with ICP-OES.做仪器检出限的目的是来确认仪器对可迁移元素元素的检出限.2 Procedure(过程) 2.1 Place the reagent blank to the ICP 将试剂空白打入ICP中。 2.2 Take a series of seven replicate measurements for soluble elements 重复读7次试剂空白,记录可迁移元素的强度。2.3 Analyze the seven replicates and calculate the IDL as 1.645 standard deviation. 分析这七次重复测量值并计算理论仪器检出限(等于1.645标准偏差)。2.4 Verify the calculated IDL until the signal to noise ratio reaches 3:1. 校验仪器检出限直到信背比为3:1。3 Results(结果) The IDL of Soluble elements in 0.07N HCl可溶出元素在0.07N盐酸中的仪器检出限TrialMeasuredAs(mg/L) MeasuredBa(mg/L)MeasuredCd(mg/L)MeasuredCr(mg/L)MeasuredHg(mg/L)MeasuredPb(mg/L)MeasuredSb(mg/L)MeasuredSe(mg/L)1-0.00190.0000-0.0001-0.0004-0.00130.00000.00600.005220.00130.0000-0.0002-0.0003-0.0013-0.00190.00030.00393-0.0022-0.0001-0.0001-0.0002-0.0002-0.00070.0020-0.00194-0.0024-0.0001-0.0002-0.0003-0.0011-0.00150.00440.00555-0.00200.0000-0.0002-0.0002-0.0008-0.00080.00170.00076-0.0021-0.0002-0.0001-0.0002-0.0005-0.0010-0.0001-0.00787-0.00930.0000-0.0001-0.0003-0.0009-0.00140.0035-0.0058Standard Derivation0.00320.00010.00010.00010.0004140.00060.00220.005358Instrumental Detection Limit(1.645SD)0.00530.00010.00010.00010.00070.00110.00360.008813Verified IDL0.03000.00080.00080.00080.01000.02000.05000.0400Verified IDL of As,Hg,Sb,Se ,Ba,Pb,Cd,Cr in 0.07N HCLAs,Hg,Sb,Se ,Ba,Pb,Cd,C在0.07N HCL中的校验仪器检出限TrailCountBlankPb 0.0200mg/LSignal to Noise Ratio130.7716 127.2624.14222.1958127.2625.73327.7183127.2624.59424.0611127.2625.29524.0826127.2625.28626.1864127.2624.86724.7588127.2625.14Verified IDL of Pb0.0200 mg/LTrailCountBlankAs 0.0300mg/LSignal to Noise Ratio113.724064.03264.67218.239664.03263.51313.248164.03264.83412.973264.03264.94513.523864.03264.73613.441264.03264.76715.066264.03264.25Verified IDL of As0.0300 mg/LTrailCountBlankBa 0.0008mg/LSignal to Noise Ratio147.6875152.8713.21239.5933152.8713.86330.4613152.8715.02434.1127152.8714.48544.3013152.8713.45622.7092152.8716.73743.0437152.8713.55Verified IDL of Ba0.0008 mg/L TrailCountBlankCd 0.0008mg/LSignal to Noise Ratio129.384791.42113.11218.010891.42115.08322.893191.42113.99421.798391.42114.19522.313691.42114.10629.569591.42113.09728.747791.42113.18Verified IDL of Cd0.0008 mg/LTrailCountBlankCr 0.0008mg/LSignal to Noise Ratio118.299595.75435.23221.541795.75434.45327.620495.75433.47425.286895.75433.79528.116995.75433.41626.517795.75433.61723.081495.75434.15Verified IDL of Cr0.0008 mg/LTrailCountBlankHg 0.01mg/LSignal to Noise Ratio112.731460.28424.74212.738560.28424.73317.673560.28423.41413.683560.28424.41514.960660.28424.03616.264060.28423.71714.605960.28424.13Verified IDL of Hg0.01 mg/LTrailCountBlankSb 0.05mg/LSignal to Noise Ratio125.382077.23503.04213.510177.23505.72316.900977.23504.57421.927077.23503.52516.321877.23504.73612.592377.23506.13720.129077.23503.84Verified IDL of Sb0.05 mg/LTrailCountBlankSe 0.04mg/LSignal to Noise Ratio119.241768.83103.58217.499868.83103.9339.4629868.83107.27419.685268.83103.50513.045968.83105.2861.4012168.831049.1274.1165368.831016.72Verified IDL of Se0.04 mg/L (Criteria: signal to noise ratio 3:1)4 Conclusion(结论) The claimed IDL of soluble elements for EN71-3(ISO8124/ASTM F963-2003) is as below,As 0.03mg/L,Ba 0.0008 mg/L, Cd 0.0008 mg/L, Cr 0.0008 mg/L, Hg 0.01 mg/L, Pb 0.02 mg/L, Sb 0.05 mg/L, Se 0.04 mg/L. EN71-3(ISO8124/ASTM F963-2003)方法最终确认的仪器检出限为: As 0.03mg/L,Ba 0.0008 mg/L, Cd 0.0008 mg/L, Cr 0.0008 mg/L, Hg 0.01 mg/L, Pb 0.02 mg/L, Sb 0.05 mg/L, Se 0.04 mg/L.Method detection limit(方法检出限)1 Scope(目的)The purpose of this validation is to determine the method detection limit (MDL) of Pb, As, Cr, Cd, Ba,Sb,Se,Hg for materials using ICP-OES(AN-0160).确认ICP-OES对铅,砷,铬,镉,钡,锑,硒,汞的方法检出限。2 Procedure(过程)2.1 For extractable/ soluble test, MDL is estimated from verified IDL x 5. The est. MDL is spike into extraction solution without go through sample preparation. (According to CPSD-AN-TSOP Method Validation Procedure-Ver3) 根据CPSD-AN-TSOP Method Validation Procedure-Ver3,萃取测试的方法检出限相当于仪器检出限的5倍。通过在已经过处理的空白样品溶液中加标准溶液制备。2.2 Verify the MDL until the signal to noise is greater than three. Recoveries shall be between 50% and 150%, RSD shall be 20% ) 校验仪器检出限直到信背比为3:1;回收率在50%间;相对标准偏差不大于20%3 Results(结果)Calculated MDL of Pb, As, Cr, Cd, Ba,Sb,Se,Hg in 0.07N HCLPb, As, Cr, Cd, Ba,Sb,Se,Hg在0.07N 盐酸中的理论方法检出限TrialMeasuredPbMeasuredAsMeasuredCdMeasuredBa(mg/L)Recovery (%)(mg/L)Recovery (%)(mg/L)Recovery (%)(mg/L)Recovery (%)Spike Concentration0.1000-0.1500-0.0040-0.0040-10.1071070.1511010.003690.20.003382.5 20.10099.60.15099.90.003690.70.003690.0 30.1011010.14999.40.003691.20.003382.5 40.1011010.1501000.003690.50.003382.5 50.10099.80.1511010.003588.40.003485.0 60.1031030.14999.60.003691.10.003587.5 70.1021020.1511010.003690.20.003690.0 Mean0.1021020.1501000.003690.30.003485.7 Standard Derivation (SD)0.0027-0.0007-0.00004-0.0001-% RSD2.650.471.112.94Verified MDL0.1000 mg/L0.1500 mg/L0.0040 mg/L0.0040 mg/L (Criteria: Recovery =10050%, RSD20%)TrialMeasuredCrMeasuredHgMeasuredSbMeasuredSe(mg/L)Recovery (%)(mg/L)Recovery (%)(mg/L)Recovery (%)(mg/L)Recovery (%)Spike Concentration0.0040-0.0500-0.2500-0.2000-10.003997.10.046392.60.25231010.19809920.004099.70.048396.60.25731030.206710330.003998.30.046192.20.25371010.206010340.003894.10.047294.40.25441020.199010050.003690.60.047294.40.25611020.203810260.003793.00.047194.20.25321010.207710470.003895.90.05001000.25721030.2048102Mean0.003895.50.047594.90.25491020.2037102Standard Derivation (SD)0.0001-0.0013-0.0020-0.0038-% RSD2.632.740.781.87Verified MDL0.0040 mg/L0.0500 mg/L0.2500 mg/L0.2000 mg/L(Criteria: Recovery =10050%, RSD20%)Verified MDL of Pb, As, Cr, Cd, Ba,Sb,Se,Hg in 0.07N HCLPb, As, Cr, Cd, Ba,Sb,Se,Hg 在 0.07N 盐酸中的校验方法检出限TrailCountBlankPb 0.100mg/LSignal to Noise Ratio137.2257215.37237.2253314.32337.2253914.48Verified MDL of Pb0.100ppmTrailCountBlankAs 0.0150mg/LSignal to Noise Ratio123.8025810.84 223.8027011.34 323.8026211.01 Verified MDL of As0.0150ppmCountBlankCr 0.0040mg/LSignal to Noise Ratio163.113816.04 263.113906.18 363.113856.10 Verified MDL of Cr0.0040ppmTrailCountBlankCd 0.0040mg/LSignal to Noise Ratio133.4939111.68 233.4939311.73 333.4938611.53 Verified MDL of Cd0.0040ppmTrailCountBlankSb 0.250mg/LSignal to Noise Ratio114.8663042.40 214.8664243.20 314.8663342.60 Verified MDL of Sb0.250ppm TrailCountBlankSe 0.200mg/LSignal to Noise Ratio125.9234213.19 225.9235613.73 325.9235513.70 Verified MDL of Se0.200ppmTrailCountBlankHg 0.050mg/LSignal to Noise Ratio118.925913.70 218.926914.23 318.925813.65 Verified MDL of Hg0.050ppmTrailCountBlankBa 0.004mg/LSignal to Noise Ratio147.663113.26 247.662613.15 347.662913.21 Verified MDL of Ba0.004ppm (Criteria: signal to noise ratio 3:1)4 Conclusion(结论) The verified MDL of Pb, As, Cr, Cd, Ba,Sb,Se,Hg in 0.07N HCL are as below: Pb 0.10mg/L, As 0.15mg/L, Cd 0.004mg/L, Cr 0.04 mg/L, Sb 0.25mg/L,Se 0.20mg/L,Ba 0.004mg/L,Hg 0.05mg/L.最终确认在0.07N盐酸中的方法检出限为: Pb 0.10mg/L, As 0.15mg/L, Cd 0.04mg/L, Cr 0.04 mg/L, Sb 0.25mg/L Ba 0.004mg/L, Hg 0.05mg/L,Se 0.20mg/L.Precision(精密度)(For ICP-OES)1 Scope(目的) The purpose of this validation is to determine the precision of soluble elements for EN71-3(ISO8124/ASTM F963-2003) with ICP-OES. 本实验的目的是来确认EN71-3(I

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论