PS9DC01多功能电池放电保护板说明书百度云产品资料PS9DC01 6-30V Battery discharge protection module_第1页
PS9DC01多功能电池放电保护板说明书百度云产品资料PS9DC01 6-30V Battery discharge protection module_第2页
PS9DC01多功能电池放电保护板说明书百度云产品资料PS9DC01 6-30V Battery discharge protection module_第3页
PS9DC01多功能电池放电保护板说明书百度云产品资料PS9DC01 6-30V Battery discharge protection module_第4页
PS9DC01多功能电池放电保护板说明书百度云产品资料PS9DC01 6-30V Battery discharge protection module_第5页
已阅读5页,还剩2页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

PS9DC01 6-30V Battery discharge protection module Product Specifications: Operating voltage: DC 6-30V. Operating current (12V): Standard mode, standby current 7MA; Working current 11MA; Energy-Saving mode,Standby current 4MA; Working current 7MA. 3 control buttons, 4 bit digital display, 1 LED charge indicator. Mode: Standard-Mode, Energy-Saving Mode, Setup-Mode, Voltage-Calibration, Factory-Settings. Can protect any 6-30V battery discharge, double N-MOS maximum load current: 15A (6-15V); 10A (15-30V) .The default Cutoff discharge voltage 11.8V, Start discharge voltage is 12.2V(for 12V lead acid battery). Size : 60 x 35x 16mm Weight : 19g Features: 1 Photoelectric isolation can effectively protect the circuit board. 2 1% high-precision divider resistors make the measurement voltage more accurate. 3 Voltage accuracy and resolution is 0.1V, and with a calibration function. 4 Reduce the brightness of the digital display, save energy and protect your eyes. 5 parameter power-down save, to avoid duplicate settings. 6 Set the Start Discharge Voltage(H) and Cutoff Discharge Voltage(L) to the lowest (power on). For example, the power supply voltage is 12.00V and the module display voltage is 12.34V. At this time, calibration is required. 1.Press and hold the SET button first, and then power on (be sure to press the button first, and then power on), then the digital tube displays 12.34V;2.Trigger DEC or INC button, let the digital tube display 12.00V 3.Trigger the SET button again to save the parameters. (If you do not want to save the parameters, please power off) Factory-Settings:In the Standard-Mode, press and hold the SET and INC buttons at the same time, until the digital display shows8888, at this time, restore the factory settings, Cutoff-Discharge-Voltage is 11.8V, Start-Discharge-Voltage is 12.8V. (Note: voltage calibration parameters cannot be reset to factory settings) Operation Steps (must follow the steps): Example 1: We want to set 12V lead-acid battery discharge protection function, Cutoff-Discharge-Voltage is 11.7V and Start-Discharge-Voltage is 12.9V. Step 1: Connect the batterys positive and negative ports to the modules BAT+/BAT- ports (to ensure that the battery has more than 20% of the capacity); the digital tube will display the battery voltage (such as the battery voltage is 12.1V, the digital display will show C12 .1) Step 2: Trigger the INC button, the digital display will show H12.8, then trigger the SET button, H will flash, this is the Start-Discharge-Voltage setting mode.Step 3: In the Start-Discharge-Voltage setting mode, trigger the INC button to increase the voltage and the DEC button to decrease the voltage. Long press INC or DEC button to quickly set the voltage.Step 4: Set the voltage to H12.9 and trigger the SET button to save the settings.Step 5: Trigger the DEC button, the digital display will show L11.8, then trigger the SET button, L will flash, this is the Cutoff-Discharge-Voltage setting mode.Step 6: In the Cutoff-Discharge-Voltage setting mode, trigger the INC button to increase the voltage and the DEC button to decrease the voltage. Long press INC or DEC button to quickly set the voltage.Step 7: Set the voltage to L11.7 and trigger the SET button to save the settings.Step 8: Disconnect the port BAT +/BAT- and connect the port OUT+/OUT- to the load.Step 9: Connect the port BAT +/BAT- again and re-power it. After 3 seconds delay, the load will be powered.Example 2: Start-Discharge-Voltage(H) and Cutoff-Discharge-Voltage(L) has been set, Direct wiring.Step 1: Connect port OUT+/OUT- to the loadStep 2: Connect the batterys positive and negative ports to the modules BAT+/BAT- ports (to ensure that the battery has more than 20% of the capacity); the digital tube will display the battery voltage (such as the battery voltage is 12.1V, the digital display will show C12 .1)Step 3: Power is supplied to the load after a delay of 3 secondsQ&A:Q1: The suitable battery voltage? Types of Batteries?A1: This module is suitable for all batteries in the range of 6-30V, lead-acid batteries, lithium batteries and even dry batteries. Battery type : Lead-acid /Ni-Cd / Ni-MH / Li-ION /Li-PO / LiFe /Polymer Lithium battery.Q2: Can parameters be saved after power off?A2: Yes, the parameters can be saved when powered off.Q3: Why does the digital tube not display after the battery is connected?A3: 1. It may be that the battery capacity is too low. Please charge the battery with the charger first. 2. Poor connection or reverse polarity 3. It is possible that the module has entered the Energy-Saving Mode,press and hold the SET button until the digital display.Q4: Why cant I increase the Cutoff-Discharge-Voltage(L)?A4: Please increase the Start-Discharge-Voltage(H) first.Q5: Why cant I discrease the Start-Discharge-Voltage(H) ?A5: Please discrease the Cutoff-Discharge-Voltage(L) first.Q6: Why relay turn on and off frequently?A6: 1 It may be too much load current, or the battery capacity is too small. 2 It may be Cutoff-Discharge-Voltage(L) and Start-Discharge-Voltage(H) too close.Q7: What is the control method? Can it be used as a charge protection? Can it limit the current?A7: 1 This is a voltage control method 2 NO! This can only be used for discharge protection. It cannot be used for charging protection. For charging protection, please use the PS46A01 module. 4 No! This module can only control the voltage and cannot control th

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论