




已阅读5页,还剩49页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
CT成像原理介紹,ComputedTomography,CTBasicsPrincipleofSpiralCTScanParameter&ImageQualityOptimizingInjectionProtocolsClinicalApplications,X-RayDiscovery,X-raywasdiscoveredbyaGermanscientistRoentgen100yearsago.Thismadepeopleforthefirsttimebeabletoviewtheanatomystructureofhumanbodywithoutoperation,ButitssuperimposedAndwecouldntviewsofttissue,MynameisGodfreyHounsfieldIworkfortheCentralResearchLabs.ofEMI,LtdinEnglandIdevelopedthethefirstclinicallyusefulCTscannerin1971,HistoryofComputedTomography,Early1970s,1963-AlanCormackdevelopedamathematicalmethodofreconstructingimagesfromx-rayprojections,Forthefirsttimewecouldview:,CTBroketheBarrier,-Tomographicor“Slice”anatomy-Densitydifference,ButitstimeconsumingAndresolutionneedstobeimproved,ConceptofX-rayAttenuation,AnX-raybeampassingthroughthebodyisattenuated(losesitsenergy)by:AbsorptionScattering,IncidentX-ray,Transmittedray,SCATTEREDX-RAYS,BODYTISSUE,Absorptionbythetissueisproportionaltothedensity,Lessdensetissue,Moredensetissue,MOREATTENUATION,LESSATTENUATION,HowdoesCTWork?,X-raygoesthroughcollimatorthereforepenetrateonlyanaxiallayeroftheobject,calledslice,HowdoesCTWork?,PatientisplacedinthecenterofthemeasurementfieldX-rayispassedthroughthepatientsslicefrommanydirectionalonga360pathThetransmittedbeamsarecapturedbythedetectorswhichdigitizesthesesignalsThesedigitizedsignalscalledrawdataaresenttoacomputerwhichcreatetheCTimage,HowdoesCTWork?,Theobjectsliceisdividedintosmallvolumeelementscalledvoxels.Eachvoxelisassignedavaluewhichisdependentontheaverageamountofattenuation,HowisCTImagegenerated?,Theattenuationvaluesaretransferredtothecomputerwheretheyarecoded&usedtocreateasliceimage,HowisCTImagegenerated?,CTGenerations&Design,“Generation”isusedtolabelCTtube-detectordesigns,3rdGenerationDesignRotatingtube&detector,4thGenerationDesignFixedringdetector,Slip-ringTechnology,PoweristransmittedthroughparallelsetsofconductiveringsinsteadofelectricalcablesContinuousGantryRotationPrerequisiteforSpiralCT,NonSlip-ringScanner,Slip-ringScanner,ComputedTomography,CTBasicsPrincipleofSpiralCTScanParameter&ImageQualityOptimizingInjectionProtocolsClinicalApplications,WhatisSpiralScan?-just4“C”,Continuouslyrotatingtube/detectorsystemContinuouslygeneratingX-rayContinuouslytablefeedContinuouslydataacquisition,Reconstructionofarbitraryslices(eithercontiguousoroverlapping)withinthescannedvolumeDistancebetweentheslicesiscalledIncrement,A,B,VolumeData,Continuousdataacquisition,Increment,SliceThickness,Increment=SliceThicknessNoOverlapNoGaps,ContiguousImageReconstruction,Increment,Overlap,Slice,Thickness,OverlappingImageReconstruction,IncrementSliceThicknessGapsbetweenslicesImagesarefurtherapartLessimagescreated,ImageReconstructionwithGaps,Increment,SliceThickness,StandardCT/SliceImaging,DeepInspiration,ShallowInspiration,Misregistrationduetodifferentrespiratorylevelsbetweenslices,PartialVolumeEffect,Unabletoresconstructimagesatarbitraryposition,Sliceimagingisslow,Scanthewholeregionofinterestinonebreathhold,Reconstructionofoverlappingimageswithoutadditionaldose,Retrospectivereconstructionofslicesinarbitrarypositionwithinthescannedvolume,Nogapssinceradiationalwaystransmitsthewholevolume,SpiralCT/VolumeImaging,ComputedTomography,CTBasicsPrincipleofSpiralCTScanParameter&ImageQualityOptimizingInjectionProtocolsClinicalApplications,ScanParameters,X-rayTubeVoltage(kVp)X-rayTubeCurrent(mA)ScanTime(s)SlicethicknessorCollimation(mm),TableSpeed(mm/rot)orFeedper360rotationPitchInterpolationProcessIncrement(mm),TableSpeed&Pitch,TableSpeedisdefinedasdistancetraveledinmmper360rotation,Pitch=,TableFeedperrotationCollimation,10mmP1,10mmP2,30s,30s,MoreCoverageinthesametimewithextendedPitch!,Pitch2covers2xdistanceasPitch1,ScanRange=300mm,10mmP110mm/s,10mmP220mm/s,30s,15s,CoverthesamevolumeinshortertimewithextendedPitch,Toreduceartifactsduetotablemotionduringspiralscanning,weuseaspecialreconstructionprocesscalledINTERPOLATION,Interpolation,Convertsvolumedataintosliceimages,InterpolationAlgorithm,WideAlgorithm,SlimAlgorithm,2x360=720rawdata,2(180+52)=464rawdata,WidealgorithmproducesabroaderimagethicknessWidealgorithmusesmorerawdata=lessimagenoise,PITCH2,PITCH1,Pitch2scanningproducesabroaderimagethicknessPitch2scanningdoesnotincreaseimagenoise,30%increaseinimagethicknesswithPitch2,SliceSensitivityProfile(SSP),SSPdescribestheeffectiveslicethicknessofanimageandtowhatextentanatomywithinthatslicecontributetothesignal,SSP,RESOLUTION,Allpointswithintheslicecontributeequally&pointsoutsideoftheslicedonotcontributetotheimageatall.,Imagesignal,IdealSSP,Z-axis(mm),Collimation=widthofx-raybeam=sliceprofile,SliceProfile(SP),Effectiveslicethicknessofanimage,SliceProfileResolution,FactorsinfluencingSliceProfileCollimationPitchInterpolationalgorithm(360or180),FactorsinfluencingSSP,Collimatorwidthcollimation=SSPSpiralCTTablespeedorPitchInterpolationAlgorithm=mathematicalprocessrequiredtoreconstructaxialimagesfromthespiralvolumedataset,Pitch&SliceProfile,SlimvsWideSSPComparison,SliceProfileSlim%BroadenWide%BradenPitchOne5.0mm06.3mm26PitchTwo6.5mm3010.8mm116,WIDE720degreeMorephotons,SLIM464degreeLessphotons,SSPSpatialresolution,SSPSpatialresolution,Smootherimage,Noisierimage,Slim-Advantages,ImprovedZResolutionReducedpartialvolumeartifactsSlim+extendedPitchLongercoverageSamecoveragewithshorterscantimeorthinnerslicesLessradiationdose,Wide-Advantages,NoiseReductionSmootherimageUsefulforscanninghugepatientOnlyforscanningatPitchOne,SliceProfileComparison,Lesionsmallerthan1cm,SCANRANGE=150mm,10/10/10(15s),5/10/5(15s),SliceProfile=10mm,SliceProfile=6.5mm,OptimizingtheScanningParameters,SmallestPossibleEffectiveSliceThickness,ScanLength(mm),ScanDuration(s),TableSpeed(mm/s),SmallestCollimation(mm),ScanDuration,Dependsonthescanlength&patientsbreath-holdcompliance,TableSpeedPitchFactor,1Pitch2tocoverthewholevolumeinonebreath-hold,ComputedTomography,CTBasicsPrincipleofSpiralCTScanParameter&ImageQualityOptimizingInjectionProtocolsClinicalApplications,Peripheralveineg.antecubitalvein19-20gaugeneedleorIVcatheter,Volume,FlowRate,Concentration,InjectionProtocols,300mgI/mlnon-ioniccontrast,2-5ml/scardiacoutput,80-150mlpatientsweight®ionofinterest,Site,ScanDelay,Delaybetweeninjectioninitiation&thestartofthescansequence,TailoringScan&InjectionProtocols,InjectionDurationmustbeequaltoorgreaterthanScanTime,50,100,150,200,250,Times,HU,CONTRAST,50,100,150,200,250,Times,HU,CONTRAST,NaCl,BolusDurationscantimeInsufficient,inhomogeneousopacification,BolusDuration=scantimeUniform,maximumopacification,EnhancementCurveoftheTargetRegion,50,100,150,200,250,Times,HU,OptimalWindow,Early,Time-densitycurveofthetargetregion,Late,ContrastBolusTiming,DeterminesoptimalscandelayforspiralCTAsequence,CONTRAST,NaCl,TestBolusProcedure,ImagingVolumeforspiralCTA,10-20mlofcontrastisinjectedatthechosenrateforspiral,Afteradelayof8-10s,low-dose,single-levelaxialimagesareacquiredevery2satthestartingpointoftheimagingvolume,Dynamicscansatthisposition,DynamicEvaluationtogenerateaTime-densitycurve,DynamicEvaluation,Ti
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 水溶液中的离子反应与平衡(讲义)-2023年高考化学二轮复习(新高考专用)
- CN120208785A 一种碳酸二乙酯热泵精馏装置及工艺
- 老年人保健知识培训小结课件
- 生物的变异和进化-2025年高考生物专项复习原卷版
- 人教版八年级英语下册专练:短文填空20篇(含答案)
- CN120198213A 基于穿透监管的自适应风险评估调整方法及系统
- 人教版八年级英语下册 Unit 1-Unit 10 期末复习之作文书面表达范文
- 配送员礼仪基础知识培训课件
- 2025版水电费远程抄表与用户服务合同
- 2025年企业研发项目抵押借款合同
- 综合与实践:数学连环画(大单元教学设计) 一年级数学下册 (苏教版2025)
- 《电子商务基础(第二版)》课件 第三章 网络营销
- GB/T 45637-2025电动牙刷性能测试方法
- 菜鸟驿站合伙合同协议
- 2025年呼伦贝尔农垦集团有限公司工作人员招聘考试试题
- 公司志编纂工作方案
- 新人教版物理八年级下册知识点总结-物理八年级下册考点人教版
- 抗战胜利70周年主题班会教案
- 2025年九年级语文上册课后习题参考答案
- 全套课件-工程建设监理概论
- 餐饮服务与数字化运营 习题及答案 项目三
评论
0/150
提交评论