已阅读5页,还剩49页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
.,1,CT成像原理介紹,ComputedTomography,CTBasicsPrincipleofSpiralCTScanParameter&ImageQualityOptimizingInjectionProtocolsClinicalApplications,X-RayDiscovery,X-raywasdiscoveredbyaGermanscientistRoentgen100yearsago.Thismadepeopleforthefirsttimebeabletoviewtheanatomystructureofhumanbodywithoutoperation,ButitssuperimposedAndwecouldntviewsofttissue,MynameisGodfreyHounsfieldIworkfortheCentralResearchLabs.ofEMI,LtdinEnglandIdevelopedthethefirstclinicallyusefulCTscannerin1971,HistoryofComputedTomography,Early1970s,1963-AlanCormackdevelopedamathematicalmethodofreconstructingimagesfromx-rayprojections,Forthefirsttimewecouldview:,CTBroketheBarrier,-Tomographicor“Slice”anatomy-Densitydifference,ButitstimeconsumingAndresolutionneedstobeimproved,ConceptofX-rayAttenuation,AnX-raybeampassingthroughthebodyisattenuated(losesitsenergy)by:AbsorptionScattering,IncidentX-ray,Transmittedray,SCATTEREDX-RAYS,BODYTISSUE,Absorptionbythetissueisproportionaltothedensity,Lessdensetissue,Moredensetissue,MOREATTENUATION,LESSATTENUATION,HowdoesCTWork?,X-raygoesthroughcollimatorthereforepenetrateonlyanaxiallayeroftheobject,calledslice,HowdoesCTWork?,PatientisplacedinthecenterofthemeasurementfieldX-rayispassedthroughthepatientsslicefrommanydirectionalonga360pathThetransmittedbeamsarecapturedbythedetectorswhichdigitizesthesesignalsThesedigitizedsignalscalledrawdataaresenttoacomputerwhichcreatetheCTimage,HowdoesCTWork?,Theobjectsliceisdividedintosmallvolumeelementscalledvoxels.Eachvoxelisassignedavaluewhichisdependentontheaverageamountofattenuation,HowisCTImagegenerated?,Theattenuationvaluesaretransferredtothecomputerwheretheyarecoded&usedtocreateasliceimage,HowisCTImagegenerated?,CTGenerations&Design,“Generation”isusedtolabelCTtube-detectordesigns,3rdGenerationDesignRotatingtube&detector,4thGenerationDesignFixedringdetector,Slip-ringTechnology,PoweristransmittedthroughparallelsetsofconductiveringsinsteadofelectricalcablesContinuousGantryRotationPrerequisiteforSpiralCT,NonSlip-ringScanner,Slip-ringScanner,ComputedTomography,CTBasicsPrincipleofSpiralCTScanParameter&ImageQualityOptimizingInjectionProtocolsClinicalApplications,WhatisSpiralScan?-just4“C”,Continuouslyrotatingtube/detectorsystemContinuouslygeneratingX-rayContinuouslytablefeedContinuouslydataacquisition,Reconstructionofarbitraryslices(eithercontiguousoroverlapping)withinthescannedvolumeDistancebetweentheslicesiscalledIncrement,A,B,VolumeData,Continuousdataacquisition,Increment,SliceThickness,Increment=SliceThicknessNoOverlapNoGaps,ContiguousImageReconstruction,Increment,Overlap,Slice,Thickness,OverlappingImageReconstruction,IncrementSliceThicknessGapsbetweenslicesImagesarefurtherapartLessimagescreated,ImageReconstructionwithGaps,Increment,SliceThickness,StandardCT/SliceImaging,DeepInspiration,ShallowInspiration,Misregistrationduetodifferentrespiratorylevelsbetweenslices,PartialVolumeEffect,Unabletoresconstructimagesatarbitraryposition,Sliceimagingisslow,Scanthewholeregionofinterestinonebreathhold,Reconstructionofoverlappingimageswithoutadditionaldose,Retrospectivereconstructionofslicesinarbitrarypositionwithinthescannedvolume,Nogapssinceradiationalwaystransmitsthewholevolume,SpiralCT/VolumeImaging,ComputedTomography,CTBasicsPrincipleofSpiralCTScanParameter&ImageQualityOptimizingInjectionProtocolsClinicalApplications,ScanParameters,X-rayTubeVoltage(kVp)X-rayTubeCurrent(mA)ScanTime(s)SlicethicknessorCollimation(mm),TableSpeed(mm/rot)orFeedper360rotationPitchInterpolationProcessIncrement(mm),TableSpeed&Pitch,TableSpeedisdefinedasdistancetraveledinmmper360rotation,Pitch=,TableFeedperrotationCollimation,10mmP1,10mmP2,30s,30s,MoreCoverageinthesametimewithextendedPitch!,Pitch2covers2xdistanceasPitch1,ScanRange=300mm,10mmP110mm/s,10mmP220mm/s,30s,15s,CoverthesamevolumeinshortertimewithextendedPitch,Toreduceartifactsduetotablemotionduringspiralscanning,weuseaspecialreconstructionprocesscalledINTERPOLATION,Interpolation,Convertsvolumedataintosliceimages,InterpolationAlgorithm,WideAlgorithm,SlimAlgorithm,2x360=720rawdata,2(180+52)=464rawdata,WidealgorithmproducesabroaderimagethicknessWidealgorithmusesmorerawdata=lessimagenoise,PITCH2,PITCH1,Pitch2scanningproducesabroaderimagethicknessPitch2scanningdoesnotincreaseimagenoise,30%increaseinimagethicknesswithPitch2,.,30,SliceSensitivityProfile(SSP),SSPdescribestheeffectiveslicethicknessofanimageandtowhatextentanatomywithinthatslicecontributetothesignal,SSP,RESOLUTION,Allpointswithintheslicecontributeequally&pointsoutsideoftheslicedonotcontributetotheimageatall.,Imagesignal,IdealSSP,Z-axis(mm),Collimation=widthofx-raybeam=sliceprofile,SliceProfile(SP),Effectiveslicethicknessofanimage,SliceProfileResolution,FactorsinfluencingSliceProfileCollimationPitchInterpolationalgorithm(360or180),.,32,FactorsinfluencingSSP,Collimatorwidthcollimation=SSPSpiralCTTablespeedorPitchInterpolationAlgorithm=mathematicalprocessrequiredtoreconstructaxialimagesfromthespiralvolumedataset,.,33,Pitch&SliceProfile,.,34,SlimvsWideSSPComparison,SliceProfileSlim%BroadenWide%BradenPitchOne5.0mm06.3mm26PitchTwo6.5mm3010.8mm116,.,35,WIDE720degreeMorephotons,SLIM464degreeLessphotons,SSPSpatialresolution,SSPSpatialresolution,Smootherimage,Noisierimage,.,36,Slim-Advantages,ImprovedZResolutionReducedpartialvolumeartifactsSlim+extendedPitchLongercoverageSamecoveragewithshorterscantimeorthinnerslicesLessradiationdose,.,37,Wide-Advantages,NoiseReductionSmootherimageUsefulforscanninghugepatientOnlyforscanningatPitchOne,SliceProfileComparison,Lesionsmallerthan1cm,SCANRANGE=150mm,10/10/10(15s),5/10/5(15s),SliceProfile=10mm,SliceProfile=6.5mm,OptimizingtheScanningParameters,SmallestPossibleEffectiveSliceThickness,ScanLength(mm),ScanDuration(s),TableSpeed(mm/s),SmallestCollimation(mm),ScanDuration,Dependsonthescanlength&patientsbreath-holdcompliance,TableSpeedPitchFactor,1Pitch2tocoverthewholevolumeinonebreath-hold,ComputedTomography,CTBasicsPrincipleofSpiralCTScanParameter&ImageQualityOptimizingInjectionProtocolsClinicalApplications,Peripheralveineg.antecubitalvein19-20gaugeneedleorIVcatheter,Volume,FlowRate,Concentration,InjectionProtocols,300mgI/mlnon-ioniccontrast,2-5ml/scardiacoutput,80-150mlpatientsweight®ionofinterest,Site,ScanDelay,Delaybetweeninjectioninitiation&thestartofthescansequence,TailoringScan&InjectionProtocols,InjectionDurationmustbeequaltoorgreaterthanScanTime,50,100,150,200,250,Times,HU,CONTRAST,50,100,150,200,250,Times,HU,CONTRAST,NaCl,BolusDurationscantimeInsufficient,inhomogeneousopacification,BolusDuration=scantimeUniform,maximumopacification,EnhancementCurveoftheTargetRegion,50,100,150,200,250,Times,HU,OptimalWindow,Early,Time-densitycurveofthetargetregion,Late,ContrastBolusTiming,DeterminesoptimalscandelayforspiralCTAsequence,CONTRAST,NaCl,TestBolusProcedure,ImagingVolumeforspiralCTA,10-20mlofcontrastisinjectedatthechosenrateforspiral,Afteradelayof8-10s,low-dose,single-levelaxialimagesareacquiredevery2satthestartingpointoftheimagingvolume,Dynamicscansatthisposition,DynamicEvaluationtogenerateaTime-densitycurve,DynamicEvaluation
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 汽车回收拆解工岗位合规化技术规程
- 塑料浇铸工安全应急评优考核试卷含答案
- 皮具制作工岗位职业健康、安全、环保技术规程
- 快件揽收员岗前环保及安全考核试卷含答案
- 热力管网运行工岗前工作合规化考核试卷含答案
- 2025年南皮县中小学教师招聘笔试备考试题及答案解析
- 2025年怀集县教师招聘笔试参考试题及答案解析
- 2025年广东低压电工作业特种作业考前冲刺备考速记速练500题-含答案
- 2025年鹰潭市中小学教师招聘笔试备考试题及答案解析
- 2025年临猗县中小学教师招聘笔试参考试题及答案解析
- 管业制造安全应急预案范文
- 2025年高性能叠片电池发展研究报告
- 人工运动场草坪施工方案
- 财政局岗位业务测试(会计、社保专管员)试题附答案
- 2025年中国夹层玻璃行业发展现状、市场前景、投资方向分析报告(智研咨询)
- 股份制商业银行数字化转型策略及路径研究-以浦发银行为例
- 2025年新版医院财务科招聘考试题目含答案
- 智慧树知道网课《中成药临床应用(广西中医药大学)》课后章节测试答案
- 智联招聘笔试题库
- 职场礼仪课件
- 湖南省长沙市师范大学附属中学2025-2026学年高三上学期8月月考(一)语文含答案
评论
0/150
提交评论