1、 Vv22电缆载流量 来源:发布时间:2013-03-11浏览:8840次 电力电缆VV22-4*50+1*25的载流量是多少查GB 50217-2007电力工程电缆设计规范附录,得知:空气中敷设:104A;直埋敷设:129A.VV22-0.6/1KV 4X50+1X25 载流量: 土壤敷设:155A 空气敷设:115A大概可接电器:60KW 左右VV22电缆的载流量见表8-32-2表8-32-2 NH-VV22电缆的载流量型号及电压等级ZR- VV22、ZR-VLV22 0.6/1kv标称截面积mm参考外径/mm载流量推荐值/A成品参考 考质量/(kg/km)空气中敷设埋地敷设铜芯铜芯101

2、5.776973881616.71011274722518.51321666133519.61612027375021.41912409117023.224230211589525.5298361148312027.1347415176315029.1395468209118531.6459530253924036.0554623354530039.063770842782x4.022.534415902x6.023.643536582x1026.158708282x1628.2779210112x2531.710412213472x3535.612914919772x5033.5146171

3、21282x7036.118821426142x9540.023726732832x12042.427430638792x15046.031634646432x18549.636839655043x4.023.629366833x6.024.737457813x1027.550609913x1629.8667912723x2533.79010517063x3537.111112724533x5038.112914821823x7040.316518535203x9544.720622144723x12047.924226153613x15052.728129664743x18557.03283

4、3776943x24062.538638996073x30067.2445441121403x4.0+1x2.524.930377663x6.0+1x4.026.438468913x10+1x6.029.1526411343x16+1x1031.7708414653x25+1x1637.29310823383x35+1x1639.511313028283x50+1x2542.014215833363x70+1x3045.818119841983x95+1x5051.322223653493x120+1x7054.525826964393x150+1x7059.529730375713x185+

5、1x9564.033834091233x240+1x12070.2404396113503x300+1x15078.5472450143794x4.025.530378214x6.026.738469424x1029.8536412364x1632.6718315684x2538.29410825024x3541.111713230354x5040.714015735134x7044.417819644474x9549.621923456994x12052.925526868504x15057.629430182434x18561.73333389825VV22- 0.6/1kv铠装电缆载流量

6、型号及电压等级DYDL-ZR-VV22- 0.6/1kv标称截面积/Mm参考外径/Mm载流推荐值/A成品参考质量/Kg/Km空气中敷设埋地敷设5x4.019.431386735x6.020.739478055x1024.2556511475x1627.0728515425x2531.99610822595x3536.411913132345x5041.614515641615x7046.818719555595x9554.122523074025x12058.826326489105x15064.7301296107845x18571.6348335132484x4+1x2.510.93137

7、6314x6+1x4.020.539477754x10+1x6.023.6546510774x16+1x1026.5728414534x25+1x1631.19510821174x35+1x1635.211713029474x50+1x2540.314315538394x70+1x3545.118419450424x95+1x5052.222422967614x120+1x7056.926026282294x150+1x7061.929629497184x185+1x9568.6329333120574x240+1x12077.1408388153174x300+1x15085.0469442

8、187383x4.0+2x2.518.530376053x6.0+2x4.020.238477533x10+2x6.022.9536410093x16+2x1026.0718413813x25+2x1630.29410719843x35+2x1633.511612926733x50+2x2538.814115435493x70+2x3043.618219346303x95+2x5049.422222960803x120+2x7055.025626176163x150+2x7059.129129187633x185+2x9565.6337331109483x240+2x12073.7401385

9、138223x300+2x15081.546243916968注:单芯电缆铠装应采用非磁性材料或减少磁损耗的结构。VV22- 0.6/1kv铠装电缆载流量型号及电压等级DYDL-ZR-VV22- 0.6/1kv标称截面积/Mm参考外径/Mm载流推荐值/A成品参考质量/Kg/Km空气中敷设埋地敷设5x4.019.431386735x6.020.739478055x1024.2556511475x1627.0728515425x2531.99610822595x3536.411913132345x5041.614515641615x7046.818719555595x9554.1225230740

10、25x12058.826326489105x15064.7301296107845x18571.6348335132484x4+1x2.510.931376314x6+1x4.020.539477754x10+1x6.023.6546510774x16+1x1026.5728414534x25+1x1631.19510821174x35+1x1635.211713029474x50+1x2540.314315538394x70+1x3545.118419450424x95+1x5052.222422967614x120+1x7056.926026282294x150+1x7061.929629

11、497184x185+1x9568.6329333120574x240+1x12077.1408388153174x300+1x15085.0469442187383x4.0+2x2.518.530376053x6.0+2x4.020.238477533x10+2x6.022.9536410093x16+2x1026.0718413813x25+2x1630.29410719843x35+2x1633.511612926733x50+2x2538.814115435493x70+2x3043.618219346303x95+2x5049.422222960803x120+2x7055.0256

12、26176163x150+2x7059.129129187633x185+2x9565.6337331109483x240+2x12073.7401385138223x300+2x15081.546243916968注:单芯电缆铠装应采用非磁性材料或减少磁损耗的结构。VV22 VLV22 VV32 VLV32电力电缆载流量0.6/1KV PVC绝缘及护套铠装电力电缆长期允许载流量(载流量单位均为A)适用电线型号:VV22、VLV22、VV32、VLV321. 线芯长期工作温度: 70; 2. 环境温度: 25 ; 3. 埋地深度: 1000mm; 4. 土壤热阻系数:1.0m.C/W; 5.

13、线芯轴间距离: S=2D0.6/1kV聚氯乙烯绝缘钢带恺装聚氯乙烯护套电力电缆载流量。表8-26 VV22, VLV22型0.6/1kV聚氯乙稀绝缘钢带恺装聚氯乙烯护套电力电缆载流量表8-26 VV22, VLV22型0.6/1kV聚氯乙稀绝缘钢带恺装聚氯乙烯护套电力电缆载流量型号及芯数标称截面 面积/Mm平方参考外径/ Mm载流量推荐值/ A成品参考质量/(KG/Km)空气中敷设埋地敷设铜芯铝芯铜芯铝芯铜芯铝芯VV22VLV22单芯101376599775314250161410178127993892872515.71321031661295273663516.91611252021566

14、484265018.71911482401868135117020.524218730223210506129522.7298231361280137176512024.4347270415323163887315026.43953065083621959101918528.74593565304122395121524031.95544296234833333178330036.26374937085484091214540039.7750582814632497225735008436558626706309787651001776VV22VLV222芯2x4.016.3342741333

15、883382x6.017.3433453424543792x1020.0584570545894592x1622.0776092717485432x2525.5104811229510297042x3527.812910014911612768252x5026.514611317113314878712x7030.3188144214165217813152x9534.2237184267207280016262x12036.5274213306238336518692x15040.0316245346268405922092x18543.836828639430649842610VV22VL

16、V223芯3x4.017.0292336284503753x6.018.1372945365384253x1020.8503860467455513x1623.1665179619836753x2526.990701058213448573x3529.31118612799170210253x5031.2129100148115234414243x7034.4165127185142301717253x9538.6206160221176391321583x12041.7242188261203474125073x15045.4281218296229579030233x18551.03282

17、54337261701336143x24057.3386299389302893044983x30061.54453444413421135054473x40081.051940350439115825VV22VLV224芯4x4.018.2302437295294294x6.019.3383046376414914x1022.5534164499056444x1625.07155836512188044x2529.2947310884169010344x3533.511791132102247915684x5034.3140109157122296317334x7037.8178137196

18、151383121074x9543.1219170234187503226894x12046.3255198268208610531194x15051.0294227301233747537814x18556.2333258338262909745344x24061.3397308393305116644x30069.3464359448347150184x40090.154842551540020202VV22VLV223+1芯3x4+1x2.517.6302437294954053x6+1x419.1383046376084713x10+1x621.8524064498346033x16+

19、1x1025.57055846511437703x25+1x1628.2937210884160710173x35+1x1630.511388130101206011973x50+1x2537.0142110158123279517113x70+1x3540.7181139198152358120613x95+1x5045.0222172236183467626113x120+1x7049.7258201269209575130663x150+1x7052.0297230303235678835713x185+1x9559.5338262340264837143503x240+1x12069.

20、54043133963071052353053x300+1x15070.04723654503491357267673x400+1x18584.254442251439918398型号及芯数标称截面 面积/Mm平方参考外径/ Mm载流量推荐值/ A (环境温度25C)成品参考质量/(KG/Km)空气中敷设埋地敷设VV225芯5x419.431386065x620.739477395x1024.2556510725x1627.0728514505x2531.99610821435x3536.411913130985x5041.614515639925x7046.818719553565x9554

21、.122523071385x12058.826326486165x15064.7301296104295x18571.6348335128175x24080.8409387152265x30089.047243920062VV224+1芯4x4+1x2.510.931375724x6+1x420.539477104x10+1x623.6546510034x16+1x1026.5728413694x25+1x1631.19510820064x35+1x1635.211713028204x50+1x2540.314315536784x70+1x3545.118419448504x95+1x5052

22、.222422965114x120+1x7056.926026279484x150+1x7061.929629493874x185+1x9568.6329333116524x240+1x12077.1408388148214x300+1x15085.046944218148VV223+2芯注:单芯电缆铠装应采用非磁性材料或采用减少磁耗的结构。3x4+2x2.518.530375433x6+2x420.238476863x10+2x622.953649353x16+2x1026.0718412963x25+2x1630.29410718803x35+2x1633.511612925543x50+

23、2x2538.814115433963x70+2x3543.618219344473x95+2x5049.422222958483x120+2x7055.025626173493x150+2x7059.129129184543x185+2x9565.6337331105683x240+2x12073.7401385133623x300+2x15081.546243916419注: 注:单芯电缆恺装应采用非磁性材料或采用减少磁耗结构。VV22电力电缆载流量0.6/1KV铜芯聚氯乙烯绝缘电力电缆在空气中敷设长期连续负荷条件下允许载流量截面(mm2)长期连续负荷允许载流量(A)无铠装铠装单芯双芯三芯

24、五芯单芯双芯三芯五芯2根3根四芯(4+1)芯2根3根四芯(4+1)芯(3+1)芯(3+2)芯(3+1)芯(3+2)芯1.52.54610162535507095120150185240300400500630283647608310913817320726432237443149558767379492010582330394968891131421702162643073534064915526527548682633441677101128161193246299348401460546626738856984202637446182104127155190242282322368-303

25、7536989109132167213242282322385431-3138547091111135170217247288328393440-283647608310913817320726432237443149558767379492010582330394968891131421702162643073534064815526527548682633445677101128161193246299348401460546626738856984-38456284106130158194247288328375-3138547091111135170217246287327392439

26、-3239557191112137173221250290330398445-0.6/1kV交联聚乙烯绝缘电力电缆额定电压U/U0.6IkV型号YJV、YJLV、YJY、YJLYYJV、YJLV、YJY、YJLY、YJV22、YJLV22、YJY23、YJLY23、YJV32、YJLV32、YJY33、YJLY33芯数单芯2芯3-5芯敷设空气中土壤中空气中土壤中空气中土壤中单芯电缆排列方式导体材质CuAICuAICuAICuAICuAlCuAlCuAICuAI标称截面(mm2)1.52.52230-3040-4050-4357-2533-3647-2128-2533-463950-5367-7

27、191-7494-4455-6378-3746-4454-1016709453769312471102123158951221271639713177101488210513580112638448657394567225351241549911816820713016020124415919121325816519914017310613018921713916910913285102120144931115070191241150185252306195239292355224283304372235289218264150191258315198246159195123152159205

28、13115995120297346231268384439298340433496338387449512348398331379256293377422293334237273184213240278190210150185399455308365507591392459554624430490575650445505439498336388482540372422310355241277309347240271240300552652427502694810539629725819568639757855589664-416473326372399446312351400500777921

29、590687937107873184593410617018989761110762870-环境温度()4025402540250.6/1KV铝芯聚氯乙烯绝缘电力电缆在空气中敷设长期连续负荷条件下允许载流量标称截面(mm2)长期连续负荷允许载流量(A)无铠装铠装单芯双芯三芯五芯单芯双芯三芯五芯2根3根四芯(4+1)芯2根3根四芯(4+1)芯(3+1)芯(3+2)芯(3+1)芯(3+2)芯2.5461016253550709512015018524030040050063028374863841101321612012472883343854545236217258512330405269901

30、08132165203236274316372429509595695263445597810212315018723026831135842248657867479121283748638199121150190219247288-17233040546985104132161190219247299339-17233141557087106135164194223282305346-283748638411013216120124728833438545452362172585123304052699010813216520323627431637242950959569826344559

31、78102123150187230268311358422486578674791-283748638199121150190219247288-233040546985104132161190219247299399-233141557087106135164194223252305346-VV22电力电缆载流量:长期连续负载低压电力电缆的允许载流量0.6/1kV聚氯乙烯绝缘电力电缆允许持续载流量型号VV VLV VV22VLV22ZR-VV ZR-VLV ZR-VV22ZR-VLV22VV VLV VV22VLV22ZR-VV ZR-VLV ZR-VV22ZR-VLV22芯数单芯3-5芯敷

32、设空气中土壤中空气中土壤中单芯电缆排列方式导体材质CuAlCuAlCuAlCuAlCuAlCuAl标称截面1.519.24.27.29.15.22.2.52519312436273830191529234332641324735493926203830641345242584661503226473910574472557858836446356550167659957310076105836047846525987612096130951351057760110843511590150115155115160125957413010050145110180140185140195150115

33、901551207018014023017522517024018514511519515095225175280215270205285220185140230185120260200325250310235325250210165260205150300230375290350265365285245190300230185345270430335395300415320280215335260240410320510395455350480375335260390300300475370585455515395545425375295435340400555440690540585455625490.500640510800630660520710560.630730595920740740590810645.环

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论