版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、A 76-year-old woman presented with bilateral knee pain, left worse than right. Pre-operative radiographs of the left knee show severe, end-stage osteoarthritis. The radiographic hallmarks of osteoarthritis are: joint space narrowing, sclerosis of the subchondral bone, osteophyte formation and eventu
2、ally cystic changes in the adjacent bone Standing "alignment views" are used to determine the patient's weight bearing and mechanical axis. The technical goals of Total Knee Arthroplasty include re-establishing the patients mechanical axis and restoring the joint line. Often times, pat
3、ients will have developed severe "varus" deformity (bowed legs) or less commonly, "valgus deformity (knock kneed). After a sterile prep, the limb is draped, landmarks are identified and the mid-line knee incision is planned unless patients have old scars which are not compatible with
4、this standard incision The leg is exsanguinated and a tourniquet is used to maintain hemostasis throughout the case. Once the incision is made, the quadriceps tendon, the patella and the patellar tendon are identified. A medial para-patellar arthrotomy is made and the soft tissues are elevated from
5、the tibia. Great care must be taken not to strip to much medially or laterally as this may result in disruption of the medial collateral ligament or the patellar tendon, respectfully. Both are disastrous complications. The patella and patellar tendon are released from the underlying fat pad and othe
6、r soft tissues so the patella may be everted laterally to expose the distal femur and proximal tibia. After the patella and tendon are everted (under rake in photo), remaining capsular tissues are released. The patellar-femoral ligament above the clamp is about to be divided. Only a single cut is ma
7、de to prepare the tibia. An extramedullary alignment guide is placed and secured with pins in the proximal tibia. This guide is used to resect the proper amount of bone and create the proper surface angulation for the new tibial joint line Several pins are placed to secure the guide. Once the guide
8、is secure, the arthritic articulating surface of the tibia is resected using an oscillating saw After the cut is made with the oscillating saw, the section of tibia is removed. The resected arthritic articular surface of proximal tibia is shown After the tibial bone is resected, edges and any remain
9、ing bone are removed. Unlike the tibia, an intra-medullary guide is used to make the resection cuts on the femur. A hole is reamed from distal to proximal in the femur so the guide may be placed. The femoral guide hole is shown The placement of the intra-medullary guide with cutting block is shown.
10、Once the alignment and rotation of the cutting block are determined, the block is secured into place with pins In contrast to the tibia, a series of cuts are made to prepare the distal aspect of the femur. The first and most important is the distal femoral cut. This will be used to determine soft ti
11、ssue balancing and proper positioning of the replacement components Osteophytes are resected after the distal cut is completed. The knee is then extended and a "spacer block" is positioned to check the accuracy of the proximal tibia and distal femoral cuts. These cuts ultimately determine
12、the position of the knee replacement components, the adequacy of the soft tissue balancing and the overall success of the arthroplasty. A tensioning device is used to determine if adjustments are required Next, a series of blocks are used to determine the proper size of implant to be selected. The s
13、izing block is pinned to assure proper size and positioning The sizing block is removed. The pins are left in place and are used to position the cutting block. The anterior aspect of the femur is then resected?nbsp .followed by the posterior aspect?nbsp; .and finally the champfer cuts (angled cuts c
14、onnecting anterior and posterior surfaces with the distal surface). Soft tissue and excess bone are removed The diagram demonstrates the planes of the anterior, posterior and champfer cuts The notch of the distal femur is prepared using a series of guides as well The anterior part of the notch is co
15、mpleted with a V-shaped cut The bottom notch cut is shown. Once all the cuts are completed the surfaces are prepared for placement of trial components. The trial components are placed to determine if final adjustments are needed and occasionally to determine if a larger or smaller sized component sh
16、ould be used. Here, the femoral trial is placed. The femoral trial component is shown in place Once the femoral trial component is positioned the posterior capsule of the knee is released and osteophytes are removed The femoral component is then removed to gain access to the tibial surface. A sizing
17、 guide is used to determine the fit for the tibial component The tibial guide is pinned into place The tibial guide has an extension through which an alignment rod is placed. This is yet another built in way to continually reassess the positioning of the final implants A cavity is created in the can
18、cellous bone of the proximal tibia. The actual tibial implant has a stem to provide greater stability. Then, both femoral and tibial components are placed together to assess how they function in unison The undersurface of the patella is also resected?nbsp; .measured with a caliper?nbsp .sized approp
19、riately?nbsp .and fitted with a trial component. Any adjustments are made after taking the knee through a series of motion and stability tests The trial components are removed for a final time All prepared surfaces are inspected for a final time. The raw bone surfaces are the irrigated with antibiot
20、ic solution using a pulsatile lavage system. This removes loose bony fragments and particles. After irrigating, the bony surfaces are dried and polymethyl methacrylate bone cement is applied to the end of the femur. The actual femoral stainless steel implant is then positioned and impacted for a per
21、fect fit. Excess bone cement is removed. The final implant is inspected Cement is then applied to the proximal tibia and pressed into the interstices of the tibial bone The actual tibial implant is then pressed into position The tibial implant is also impacted for a perfect fit. Excess cement is rem
22、oved Bone cement is applied to the patella last The cement is pressed into the bone The polyethylene patellar button is then held in position with a clamp The knee is extended and irrigated a final time. The newly placed implants are taken through a series of motion and stability tests and then inspected again The quadriceps tendon and retinaculum/ca
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2026年部编版初中语文八年级上册第5单元文言文翻译练习题及答案
- 民用建筑场地排水设计报告
- 2026年人教版五年级语文上册第9单元课后同步作业及答案
- 2026年机械加工工种技能考核习题集及答案
- 天然气管道输送工程项目环境影响报告书
- 农村污水治理设计方案
- 落地式脚手架安全监理实施细则
- 老旧小区更新改造设计方案
- 透水材料工程进场验收规范
- 生物质热电联产项目环境影响报告书
- 2026年国能源招聘笔试真题及答案
- 河北省石家庄市第四十三中学2025-2026学年上学期期中考试九年级数学试题(含答案)
- 2026年新疆中考语文真题及答案解析
- GB/T 24134-2026橡胶和塑料软管静态条件下耐臭氧性能的评价
- 简析量子定位技术及应用前景
- 2026年中医内科医师高频面试题包含详细解答
- AQ3026-2026《化工企业设备检修作业安全规范》解读
- 2026年全国两会解读:基层治理能力提升
- 装配错装漏装考核制度
- 供应商风险管理课件
- 供水网格服务管理制度
评论
0/150
提交评论