1、cm530 general flux vector control lnverter user manual1contentspreface.3chapter1 safety and precautions.61.1 safety precautions.61.2 precautions.8chapter 2 product information.112.1 designation rules.112.2 nameplate.112.3 series of inverter cm530.122.4 technical specifications.132.5 physical appeara
2、nce and dimensions of mounting hole.152.6 optional parts.202.7 routine repair and maintenance of inverter.202.8 instructions on warranty of inverter.222.9 guide to model selection .222.10 guide to selection of brake components.23chapter 3 mechanical and electrical installation .253.1 mechanical inst
3、allation.253.2 electrical installation .28chapter 4 operation and display.384.1 introduction to operation and display interface .384.2 description of function code viewing and modification methods .404.3 method of viewing status parameters .414.4 password setting.414.5 automatic tuning of motor para
4、meters.43chapter 5 parameter description.455.1 group f0 basic function.455.2 group f1 start/stop control.535.3 group f2 v/f control parameters.575.4 group f3 vector control parameters .605.5 group f4 motor parameters .645.6 group f5 input terminal.665.7 group f6 output terminal .745.8 group f7 auxil
5、iary funtion and man-machine interface function .775.9 group f8 communication parameter description .845.10 group f9 fault and protection.865.11 group fa process control pid function.895.12 group fb swing frequency .92cm530 general flux vector control lnverter user manual25.13 group fc ms speed func
6、tion and simple plc function.945.14 group fd,fe (reserved) .995.15 group ff factory parameter .99chapter6 emc(electromagnetic compatibility).1006.1 definition.1006.2 standard description.1006.3 emc guide.101chapter 7 fault diagnosis and countermeasures .1047.1 fault alarm and countermeasures.1047.2
7、common fault and resolution .116chapter 8 cm530 series serial port communication protocol.1178.1 about protocol.1178.2 application mode.1178.3 bus structure.1178.4 protocol specification.1188.5 communication frame structure .1188.6 cyclical redundancy check.1218.7 cmd and status.122appendix:function
8、 parameter table .125cm530 general flux vector control lnverter user manual preface3prefacethank you for purchasing cm series flux vector control inverter.cm series inverter which is a new generation of modular can flexibly satisfy customers individual requirements and industry demand by extension o
9、f design on the premise that meet general purpose of the customers , representing the tendency of applying in the future inverters industry.in meeting to the requirements of all kinds of complicated high precision transmission with all functions of built-in universal extended interface, power speed
10、control, torque control ,practical process closed-loop control,simple plc ,flexible i/o terminal, pulse frequency given ,frequency given channel and run command channel bundled,main auxiliary given control ,swing frequency control ,speed track ,encoder break monitoring,interal break unit ,28 species
11、 fault monitoring,more than 16 ms speed control,parameters copies ,etc, at the same time,it provides equipment manufacturer with an all in-one solution of high integration ,on reducing system cost and improving system reliability have a great value.we offer two sub- modules for user as options ,that
12、 is,cm530 functinal module and cm580 functinal module ,the modular design will represent the development of inverter in the future .there are different between the two modules shown in table 1tab.1 difference between cm530 and cm580 funtional modulescm580:high performance modulation magnetic flux ve
13、ctor control invertercm530:general magnetic flux vector control lnverterinput/output interminal6di bidirectionalinput,2ai,2do(one high speed port fm) ,1ao,1relay,(expandable)i/o5di(bidirectional input non-high speed) ,2ai,1do,1ao,1relaycontrol mode open loop magnetic flux vectorv/fclose loop magneti
14、c flux vectoropen loop torqueclose loop torqueopen loop magnetic flux vector 1open loop magnetic flux vector 2v/fopen loop torquecontrol motorac asynchronous motorac permanent magnetic ac asynchronous motorpreface general flux vector control lnverter user manual 4synchronous motor (simple servo moto
15、r function available) expansion function of specialized industrial module availabenonei/o expansion cardavailabenonepg cardavailabenonefixed-length controlavailabenonecommunication functionmodbus(communication standard)profibus dp(extended by the expansion card)modbus(485 communication standard)swit
16、ching function of two motor parametersavailabenonecompared with traditional voltage vector control ,current vector control gains main advantages as follow :1、start torque:0.5hz,180% rated torque(open loop magnetic flux vector contro l );2、flux-weakenig control algorithm,maximum can exceed 2 times th
17、e fundamental frequency operation of motor;3、precise speed control accuracy:open loop magnetic flux vector contro l 0.5%(rated sync-speed),close loop magnetic flux vector control 0.2%(rated sync-speed);4、more stable speed conrol stability:open loop magnetic flux vector contro l 0.3(rated sync-speed,
18、close open flux vector control0.1%(rated sync-speed);5、faster torque response performance 40ms (open loop magnetic flux vector control);20ms (close loop flux vector control)。this manual is a guide to the operations of cm series inverter and cm530 control module .regarding the opeation of cm530 contr
19、ol module ,please read it for details.this manual provides the user with precaustions and instructions concerning the prototyping ,installation,parameter setting,on-site commissioning ,fault diagnosis, routine repair and maintenance of inverter.please read the instruction manual carefully before the
20、 proper use of cm530 general flux vector control lnverter user manual preface5cm530 series inverter ,and stay keeping it for the future use.the supporting equipment customers shall distribute this manual together with equipment to the final users .unpacking and inspectionplease confirm carefully whe
21、n unpacking the box:1、if the model and inverter rated values on the nameplate are the same as your order.the box contains the equipment certificate of confomity ,user manual and warranty card 2、if the product is damaged during the transportation,please contact our company or the supplier immediately
22、 if there is any omission or damage.fist time use :the users who use the product for firt time shall read this manual carefully .for any doubt about certain functions and performances,please contact the technical support personnel of our company for help so as to use the product properly.the informa
23、tion our company provides are suject to change without additional notice due to the constant improvement of the inverter products .cm series inverter is accordance with international standards ,and some products have passed in ce standardsiec/en61800-5-1:safety regulation on commissionable electric
24、drive systemiec/en61800-3:commissionalbe electric drive system ,third part :electromagnetic compatibility standard and specific testing method for the produtssafety and precautions cm530 general flux vector control lnverter user manual6chapter1 safety and precautionssafety definition:in this manual,
25、 safety precautions are divided into two types below:!dangerdanger arising due to improper operations may cause severe hurt or even death.caution!danger arising due to improper operations may cause moderate hurt or light hurt or equipment damage.1.1 safety precautions1.1.1 before installation:!dange
26、r1.do not use the damaged inverter or inverter with missing parts. otherwise, there may be risk of injury.2.use the motor with class b or above insulation. otherwise, there may be risk of electric shock.1.1.2 during the installation:!danger1.mount the inverter on incombustible surface like metal, an
27、d keep away from fammable substances. otherwise it may cause fire.caution!2.when more than two inverters are to be installed in one cabinet, due attention shall be paid to the installation locations (refer to chapter 3 mechanical and electrical installation) to ensure the heat sinking effect.3.do no
28、t drop the lead wire stub or screw in the inverter. otherwise it may damage the inverter.1.1.3 during wiring:!danger1.operation shall be performed by the professional engineering technician. otherwise there will be danger of electric shock!2.there shall be circuit breaker between the inverter and po
29、wer supply. otherwise, there may be fre!3.make sure the power is disconnected prior to the connection.otherwise there will be danger of electric shock!4.the earth terminal shall be earthed reliably. otherwise there may be danger of electric cm530 general flux vector control lnverter user manual safe
30、ty and precautions7shock.caution!1.1.4 before power-on:!danger1.please confirm whether the power voltage class is consistent with the rated voltage of the inverter and whether the i/o cable connecting positions are correct,and check whether the external circuit is short circuited and whether the con
31、necting line is frm.otherwise it may damage the inverter.the cover must be well closed prior to the inverter power-on. otherwise electric shock may be caused.2.the cover must be well closed prior to the inverter power-on.otherwise electric shock may be caused!caution!3.the inverter is free from diel
32、ectric test because this test is performed prior to the delivery. otherwise accident may occur!4.whether all the external fittings are connected correctly in accordance with the circuit provided in this manual.otherwise accident may occur!1.1.5 upon power-on!danger1.do not open the cover of the inve
33、rter upon power-on.otherwise there will be danger of electric shock!2.do not touch the inverter and its surrounding circuit with wet hand.otherwise there will be danger of electric shock!3.do not touch the inverter terminals(including control terminal).otherwise there will be danger of electric shoc
34、k!4.at power-on,the inverter will perform the security check of the external heavy-current circuit automatically.thus,at this time please do not touch the terminals u, v and w,or the terminals of motor,otherwise there will be danger of electric shock.caution!5.if parameter identification is required
35、,due attention shall be paid to the danger of injury arising from the rotating motor.otherwise accident may occur!6.do not change the factory settings at will. otherwise it may damage the equipment!1.1.6 during the operation:!danger1.do not close to the machinery and equipment if select restart func
36、tion. otherwise,personal injury may be caused!2.do not touch the fan or discharge resistor to sense the temperature.otherwise,you may get burnt!3.detection of signals during the operation shall only be conducted by qualifed technician. otherwise, personal injury or equipment damage may be caused!saf
37、ety and precautions cm530 general flux vector control lnverter user manual8caution!4.during the operation of the inverter, keep items from falling into the equipment.otherwise, it may damage the equipment!5.do not start and shut down the inverter by connecting and disconnecting the contactor. otherw
38、ise, it may damage the equipment!1.1.7 during repair!danger1. do not repair and maintain the equipment with power connection.otherwise there will be danger of electric shock!2. be sure to conduct repair and maintenance after the charge led indictor of the inverter is off. otherwise, the residual cha
39、rge on the capacitor may cause personal injury!3. the inverter shall be repaired and maintained only by the qualifed person who has received professional training.otherwise,it may cause personal injury or equipment damage!1.2 precautions1.2.1 motor insulation inspectionwhen the motor is used for the
40、 frst time,or when the motor is reused after being kept,or when periodical inspection is performed, it shall conduct motor insulation inspection so as to avoid damaging the inverter because of the insulation failure of the motor windings.the motor wires must be disconnected from the inverter during
41、the insulation inspection.it is recommended to use the 500v megameter, and the insulating resistance measured shall be at least 5m.1.2.2 thermal protection of the motorif the ratings of the motor does not match those of the inverter,especially when the ratedpower of the inverter is higher than the r
42、ated power of the motor, the relevant motor protection parameters in the in the inverter shall be adjusted, or thermal relay shall be mounted to protect the motor.1.2.3 running with frequency higher than standard frequencythis inverter can provide output frequency of 0hz to 400hz. if the user needs
43、to run the inverter with frequency of more than 50hz, please take the resistant pressure of the mechanical devices into consideration.1.2.4 vibration of mechanical devicethe inverter may encounter the mechanical resonance point at certain output frequencies,which can be avoided by setting the skip f
44、requency parameters in the inverter.cm530 general flux vector control lnverter user manual safety and precautions91.2.5 motor heat and noisesince the output voltage of inverter is pwm wave and contains certain harmonics, the temperature rise, noise and vibration of the motor will be higher than thos
45、e when it runs at standard frequency.1.2.6 voltage-sensitive device or capacitor improving power factor at the output sidesince the inverter output is pwm wave,if the capacitor for improving the power factor or voltage-sensitive resistor for lightning protection is mounted at the output side,it is e
46、asy to cause instantaneous over current in the inverter,which may damage the inverter.it is recommended that such devices not be used.1.2.7 switching devices like contactors used at the input and output terminalif a contactor is installed between the power supply and the input terminal of the invert
47、er, it is not allowed to use the contactor to control the startup/stop of the inverter. if use of such contactor is unavoidable,it shall be used with interval of at least one hour. frequent charge and discharge will reduce the service life of the capacitor inside the inverter.if switching devices li
48、ke contactor are installed between the output end of the inverter and the motor, it shall ensure that the on/off operation is conducted when the inverter has no output.otherwise the modules in the inverter may be damaged.1.2.8 use under voltage rather than rated voltageif the cm series inverter is u
49、sed outside the allowable working voltage range as specifed in this manual, it is easy to damage the devices in the inverter. when necessary, use the corresponding step-up or step-down instruments to change the voltage.1.2.9 change three-phase input to two-phase inputit is not allowed to change the
50、cm series three-phase inverter into two-phase one.otherwise, it may cause fault or damage to the inverter.1.2.10 lightning impulse protectionthe series inverter has lightning over current protection device, and has certain self-protection capacity against the lightning.in applications where lightnin
51、g occurs fre quently, the user shall install additional protection devices at the front-end of the inverter.1.2.11 altitude and deratingin areas with altitude of more than 1,000 meters, the heat sinking effect of the inverter may turn poorer due to rare air.therefore, it needs to derate the inverter
52、 for use. please contact our company for technical consulting in case of such condition.safety and precautions cm530 general flux vector control lnverter user manual101.2.12 certain special useif the user needs to use the inverter with the methods other than the recommended wiring diagram in this ma
53、nual, such as shared dc bus, please consult our company.1.2.13 note of inverter disposalthe electrolytic capacitors on the main circuit and the pcb may explode when they are burnt. emission of toxic gas may be generated when the plastic parts are burnt.please dispose the inverter as industrial waste
54、s.1.2.14 adaptable motor1) the standard adaptable motor is four-pole squirrel-cage asynchronous induction motor. if such motor is not available, be sure to select adaptable motors in according to the rated current of the motor.in applications where drive permanent magnetic synchronous motor is requi
55、red, please consult our company; 2) the cooling fan and the rotor shaft of the non-variable-frequency motor adopt coaxial connection.when the rotating speed is reduced,the cooling effect will be poorer.therefore,a powerful exhaust fan shall be installed,or the motor shall be replaced with variable-f
56、requency motor to avoid the over heat of the motor.3) since the inverter has built-in standard parameters of the adaptable motors,it is necessary to perform motor parameter identification or modify the default values so as to comply with the actual values as much as possible,or it may affect the run
57、ning effect and protection performance; 4) the short circuit of the cable or motor may cause alarm or explosion of the inverter.therefore, please conduct insulation and short circuit test on the newly installed motor and cable.such test shall also be conducted during routine maintenance. please note
58、 that the inverter and the test part shall be completely disconnected during the test.cm530 general flux vector control lnverter user manual mechanical and electrical installation11chapter 2 product information2.1 designation rulescm530 a 4t 4r0 g b / 5r5 p binverter seriesvoltage level2s:single pha
59、se 110v3s:single phase 220v3t:three phase 220v4t:three phase 380v7t:three phase 690vdesign edition adesign edition bdesign edition cmodeladaptable motor powermark: r75 1r5 011 015motor powerkw)0.75 1.5 11 15brake unitb:including brake unitnull:noneg:gerneral typep:fan pump typefig.2-1 designation ru
60、les2.2 nameplate model: cm530-a4t4r0gb/5r5pb 4.0/5.5kwinput: ac 3ph 380440v 50/60hzoutput: ac 3ph 0440v 0400hz 9/13a sn: barcodesunye electric co.,ltd fig.2-2 nameplatemechanical and electrical installation cm530 general flux vector control lnverter user manual122.3 series of inverter cm530tab.2-1 c
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 烟台市重点中学2025届高二下物理期末考试模拟试题含解析
- 郑州市重点中学2025届物理高二第二学期期末质量检测模拟试题含解析
- 重庆市三峡名校联盟高2025届化学高二第二学期期末学业质量监测模拟试题含解析
- 盐城市高二学业水平模拟(一)化学试题
- 菜园土地承包经营权评估合同范本
- 车辆运输与货物装卸方案合同
- Elasticsearch八大经典应用
- 2025年小学校长年终述职报告范文(19篇)
- 乐山建设工程施工合同协议(17篇)
- 司炉练习试题附答案
- 家庭园艺营养土产品技术标准2022
- 浙江高等教育岗前培训考试题目-大学心理学1-20套
- 人教版五年级下数学周末练习题13(分数加减法)
- 科学青岛版五年级下册(2022年新编)21 蜡烛的燃烧 课件
- 垃圾处理-机械炉排炉
- 软件系统运维及方案
- 抗菌药物临床应用指导原则(2023年版)
- 预制混凝土构件检验原始记录表
- 护理学基础试题及答案护理学基础试题库
- GB/T 7442-2007角向磨光机
- GB/T 17702-2021电力电子电容器
评论
0/150
提交评论