1、水质悬浮物的测定重量法Water quality Determination of suspended substanceGravimetric methodGB 11901-891主题内容和适用范围本标准规定了水中悬浮物的测定。本标准适用于地面水、地下水,也适用于生活污水和工业废水中悬浮物测定。2定义水质中的悬浮物是指水样通过孔径为0.45 m的滤膜,截留在滤膜上并于103105 C烘干至恒重的物质。3试剂蒸储水或同等纯度的水。4仪器4.1常用实验室仪器和以下仪器。4.2全玻璃微孔滤膜过滤器。4.3 GN CA 滤膜、孔径 0.45 m、直径 60mm。4.4吸滤瓶、真空泵4.5无齿扁咀镶子
2、。5采样及样品贮存5.1采样所用聚乙烯瓶或硬质玻璃瓶要用洗涤剂洗净。再依次用自来水和蒸储水冲洗干净。 在采样之前,再用即将采集的水样清洗三次。然后,采集具有代表性的水样5001 000mL,盖严瓶塞。注:漂浮或浸没的不均匀固体物质不属于悬浮物质,应从水样中除去。5.2样品贮存采集的水样应尽快分析测定。如需放置,应贮存在 4C冷藏箱中,但最长不得超过七天。注:不能加入任何保护剂,以防破坏物质在固、液间的分配平衡。6步骤6.1滤膜准备用扁咀无齿镶子夹取微孔滤膜放于事先恒重的称量瓶里,移入烘箱中于103105 C烘干半小时后取出置干燥器内冷却至室温,称其重量。反复烘干、冷却、称量,直至两次称量的重
3、量差v 0.2mg。将恒重的微孔滤膜正确的放在滤膜过滤器(4.1)的滤膜托盘上,加盖配套的漏斗,并用夹子固定好。以蒸储水湿润滤膜,并不断吸滤。6.2测定量取充分混合均匀的试样100mL抽吸过滤。使水分全部通过滤膜。再以每次10mL蒸储水连续洗涤三次,继续吸滤以除去痕量水分。停止吸滤后,仔细取出载有悬浮物的滤膜放在原 恒重的称量瓶里,移入烘箱中于103105 C下烘干一小时后移入干燥器中,使冷却到室温,称其重量。反复烘干、冷却、称量,直至两次称量的重量差v0.4mg为止。注:滤膜上截留过多的悬浮物可能夹带过多的水份,除延长干燥时间外,还可能造成过滤困难,遇此情况,可酌情少取试样。滤膜上悬浮物过少
4、,则会增大称量误差,影响测定精度, 必要时,可增大试样体积。一般以 5100mg悬浮物量做为量取试样体积的实用范围。7结果的表示悬浮物含量C(mg/L)按下式计算:C(如 5)X10 V式中:C水中悬浮物浓度,mg/L ;A悬浮物+滤膜+称量瓶重量,g;B滤膜+称量瓶重量,g;V试样体积,mLo附加说明:本标准由国家环保局标准处技术提出。本标准由烟台市环境监测中心站负责起草。本标准主要起草人李长海、王文法。本标准委托中国环境监测总站负责解释。Water quality Determination of suspended substanceGravimetric methodGB 11901-
5、891. Applicable scopeIt is used to test the SS in WaterIt can be used for testing the SS in the surface or underground water, also can be used to test domestic water and industrial waste water.2 DefinitionThe suspended substance is the stuff which is left on the filter film after being filtered with
6、the hole diameter of um0.45 and has been dried in 103 to 105 C condition to standing weight.3 ReagentDistilled water or the water with same purity4 Apparatus4.1 Normal lab apparatus plus below ones4.2 Glass type micro film filter4.3 GN-CA filter film, hole diameter 0.45um, Diameter 60mm.4.4 Suction
7、bottle, vacuum pump4.5 Flat type tweezer5 Sampling and sample storage5.1 SamplingThe polyethylene bottle or hard glass bottle should be cleaned with detergent and then washed by tap water and distilled water respectively. Before sampling, it should be cleaned with the sample water 3 times. Then repr
8、esentative water sample should be taken at the volume of 500 to 1000ml, cover the cap tightly.Note: The non-consistent solid material floating or submerged can not be regarded as SS, which should be removed from the water sample.5.2 Sample storageThe water sample should be analyzed ASAP. If it needs
9、 to be stored for some time, it should be stored in the refrigerator at 4 C . But the duration can not be longer than 7 days. Note: It is not allowed to add any protection agent to avoid the damage on the balance of solid and liquid phase.6. Procedure6.1 Filtering film preparationFirstly, take the m
10、icroporous film and put it on the standing weight bottle. Then it will be dried in the oven for half an hour at the temperature of 103 to 105 C . After that, it will be moved out to cool in the dryer until its temperature drops to room temperature. It should be dried, cooled and weighted repeatedly
11、until the weight difference between two subsequent weighing is less than 0.2mg. Then the microporous film at constant weight should be correctly put on the film support tray and matching hopper should be equipped.Then it should be fastened with clamp. Wet the film with the distilled water and filtra
12、tion and suction should be continuous.6.2 TestIt is to suck 100ml of homogeneously mixed sample for filtering to get the water running through the microporous film. Next , wash it 3 times consecutively with 10ml of distilled water each time. Continue suction and filtration until getting the residual
13、 water away. After stopping filtering, put the film with SS left on top in the weighing bottle and then put them in the oven with the temperature of 103 to 105 C for 1 hr. Then take it to the dryer to cool down to room temperature. Following step is to weigh it. The drying, cooling, and weighing sho
14、uld be repeated until the weight difference of two consecutive weightings is less than 0.4mg.Note: Excessive SS on the top of microporous film may contain surplus moisture, which will increase the difficulty of filtering besides longer drying time. In that case, we can reduce the sampling volume sli
15、ghtly. On another hand, less SS on the film will also raise the weighing error and affect the measurement precision. thus, sampling volume should be increased correspondingly. Normally the sampling is done in the sample ranging from 5 to 100mg of SS.7 Result calculation:SS content:。_以 3)x10,VIn which, C: SS consistencyg; A Weight of SS+ film+ weighing bottle B: Weight of film+ weighing bottle V: Sample volumeNote:This standard is provided b
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 税务筹划与申报管理规范
- 高三侯氏制碱法课件
- 电商行业市场前景及投资研究报告:老牌焕新拥抱电商
- 离婚协议模板制作与授权使用及修改合同
- 石嘴山政务公开信息发布与传播技术服务合同
- 个人自建房产权转让合同(含土地证及配套设施)
- 广告投放风险管控代理合同
- 骨髓瘤x线影像诊断课件
- 农学领域节水灌溉制度
- 化学物质存储管理细则规定执行
- 2023年全国职业院校技能大赛-互联网+国际经济与贸易赛项规程
- 《乌鲁木齐市国土空间总体规划(2021-2035年)》
- 2024年物业经理(初级)职业鉴定考试题库(含答案)
- 儿科急危重症抢救预案及流程
- 新商品房购买合同示范文本1合集
- SY-T 5333-2023 钻井工程设计规范
- 中山红色文化
- JT-T-332-1997船用塑钢门窗-PDF解密
- 道德与法治三年级上册人教版教案全册
- 北京丰台长峰医院重大火灾事故调查报告
- 产科医疗纠纷原因及分析
评论
0/150
提交评论