1、u HP 存储存储AUTORAIDu HP 存储存储FC60u HP 存储存储VA系列系列u HP 存储存储 DS2405u HP 存储存储EVA系列系列u功耗:功耗:870VA(最大值)(最大值)u散热量:散热量:2560BTUs/小时小时 Disk Modules Cooling Fans Power Supply Module Controller LCD Display Control Panel 注意AutoRaid的硬盘安装顺序应从上至下,从左到右,否则会影响系统的I/O性能。 Module LayoutFan modulesDisk modulesPower supply mod
2、ulesController modules*Minimum supported configuration:2 Power Supplies 4 Disk Modules (4 or 9 Gbyte)3 Fan Modules1 Controller Modules Rear Panel FeatureslController X, SCSI Connector 1lController X, SCSI Connector 2lController Y, SCSI Connector 1lController Y, SCSI Connector 2l3 AC Power Connectors
3、SCSI bus reset switches areunder the rear cover. See the Service Manual for settings.nControllers have separate FWD SCSI connectors, can be on same/separate bussesnOne AC connector for each power module, can connect to separate UPS or PDUArray Module MapnPower Supplies - P1, P2, P3nDisk Modules - A1
4、-A6, B1-B6nFan Modules - F1, F2, F3nControllers - X, YlLetters are embossed next to slotslControl panel messages refer to this mappinglSCSI addressing is preset on the backplane (except Controllers)lControllers are addressed through utilities or the Control PanelController Modules (cont.)Two control
5、ler modules provide redundancyn每个控制器都有个分离的SCSI IDn同一总线的控制器SCSI ID不能相同nSCSI 地址和参数可以通过软件或控制面板设置 nControllers 包括96MB 的 NVRAM/DRAMn控制器之间NVRAM是镜像的; 如果一个失败,另一个会接管工作nNVRAM包括所有的logical到physical memory maps和写cachen一个正确的shutdown会复制NVRAM maps到每个安装的硬盘上SCSI AddressingNVRAM BasicsNote:NVRAM是电池保护的是电池保护的.永远小心移动或更换控
6、制卡的动作永远小心移动或更换控制卡的动作. Connecting SCSI Cablingn扩展总线是68针高密SCSI类型n每个总线必须要用一个SCSI终结器n控制器之间连接的 SCSI线缆大概 0.5 米n内部和外部的SCSI 线缆不能超过25米lSCSI 68-pin to 68-pin Cable (HBA to Y2)lSCSI 68-pin to 68-pin Cable (Y1 to X1)lSCSI Passive Differential Terminator (X2)Connecting SCSI CablingConnecting SCSI CablingConnecti
7、ng SCSI CablingUsing the Control PanelSimple configuration menuslPress MENU to select the Main Menu.lPress + or - to scroll to a menu.lPress ENTER to select a menu.lPress + or - to scroll through the menu items.lPress ENTER to select a displayed item.lPress + or - then press ENTER to select values f
8、or a task, enable/disable, and confirm/cancel. Control Panel Lights & Messagesn初始化失败则状态灯保持熄灭.n状态灯熄灭则阵列不可用.n橙色灯亮代表有错误,但是控制器可以和主机通讯n即使开始重建,橙色等仍然会点亮,直到坏盘被从阵列中分离.n错误信息会在控制面板中显示出来ColorIndicationOffNo power, array not available, or initializingSolid GreenDisk array ready.Solid AmberDisk array self-tes
9、t or array fault.Random Flashing GreenDisk array I/O activity.Random Flashing AmberDisk array I/O activity, Warning Mode.Module Status LightsFor fans, power modules, and disk modulesn绿灯表示工作正常.n不亮表示没有上电,或磁盘没有活动数据n橙色灯不是在自检时点亮表示有故障n当插拔模块时要小心,防止数据活电源丢失For controller modulesn绿灯表示待机状态,没有活动数据n随机闪烁表示工作正常n熄灭
10、代表没有上电,没有自检 或不可认的SCSI总线n橙色灯常亮表示有故障A proper shutdown protects the dataProper Shutdownn关闭阵列,使其对主机不可用n执行关闭动作会复制maps信息到所有的硬盘n正常的关闭后,控制器和磁盘是相互独立状态n关闭过程完成后,控制器发送NVRAM 信息到硬盘,然后进入离线状态n关闭动作可以通过 Control PanelUtilities, 或 pressing the power button on the array. A System Warning indicates an error condition. Th
11、e array remains on-line. Correct the error before making any configuration changes./opt/hparray/bin/ARMServerARMServer Command UtilitiesDetailed man pages exist for each of these commands, and also for ARMServer.The Array Monitor Daemon (arraymond) monitors the system in regular intervalsCommand Nam
12、eDescription arraydspProvides information about the configuration and operating state of the array. arraymgrConfigures the overall operating characteristics of the array, such as the SCSI protocol, caching and active hot spare. arraycfgConfigures the logical parameters of the array, primarily LUN co
13、nfiguration, along with disk utilization. arrayfmtFormats the array. arrayrbldUsed to initiate, terminate and evaluate the rebuild of a disk in the array.arraydsp -iThis command is used to display the serial numbers of all arrays known by the host. ARMServer commands typically require an , which is
14、either the array serial number, or the arrays character device file name. You might then choose to command to set up a shorter identifier:# export a1=000000786B74 OR # a1=000000786B74The identifier $a1 can now be used to identify the array rather than typing in the lengthy serial number.# arraydsp -
15、iArrays known to the ARMServer: arrays with S/N: 000000786B74Display array serial number(s):# arraydsp -RRescan the bus:Find the array identifiers:# ioscan -fn -C diskArraydsp Command SummaryCommands used to view array settingsarraydspNo option, displays general array information.arraydsp -i Display
16、s all arrays currently known by the host.arraydsp -l Displays LUN specific information.arraydsp -dDisplays disk information.arraydsp -s Displays general settings information.arraydsp -vDisplays RAID 0/1 capacity.arraydsp -aQuick view of all configuration and status information.arraydsp -c Displays c
17、ontroller information.arraydsp -hDisplays hardware information.arraydsp -mDisplays detailed performance metrics by date & time.See Man pages for additional information on arraydsp optionsarraydsp Viewing general array informationClicking on any of the module images provides information for that
18、module in the lower left corner of the screen. Green status lights are displayed for good working modules, amber is displayed for failures, and no light is displayed for missing modules. It is important to note that the display is not updated real time.USE SAM Manager Autoraid行重构,因此在阵列有数据的情况下,不要不要随意
19、拔插磁盘随意拔插磁盘,特别禁止交换磁盘的位置特别禁止交换磁盘的位置。u磁盘阵列是按照长时间稳定运行的模式设计的。所以在运行条件具备的情况下,建议尽量减少开,关机次数,否则会影响系统的寿命。u HP 存储存储AUTORAIDu HP 存储存储FC60u HP 存储存储VA系列系列u HP 存储存储 DS2405u HP 存储存储EVA系列系列u功耗:FC60 180W (MAX)SC10 467W (MAX) Array ControllersController FansController BatteriesPower SuppliesPower Supply FansDisksPower
20、SuppliesFansBus ControlCards SPLIT BUSa.Split-bus模式允许在一个盘柜中做磁盘镜像.b. Split-bus模式使用很少的SCSI ID, 提高了总线性能.BatteryControllersFansControllerLEDsFC60控制柜前视图控制柜前视图LEDsFC60控制柜后视图控制柜后视图O ptim us P rim e H A C onfigurations -M u lti H ost an d D istan ceSP UO ptim usP rim e StorageSystemH ub SP USP USP UH ubH ub
21、H ubO ptim usP rim e StorageSystemO ptim usP rim e StorageSystemP rim ary P athR edundant P athFC60 HA环境环境SPUFC Adapter AFC Adapter BFCAL-BLVDSCSILVDSCSIFCAL-ALUN 0LUN 1LUN 2LUN 3LUN 4Optimus Controller A Controller B Megatron JBODBCC 1BCC 2Single SPU, single array of two controllers & 1 JBOD, R
22、AID-1Megatron JBODSPUFC Adapter AFC Adapter BFCAL-BLVDSCSILVDSCSIFCAL-ALUN 01234Optimus Controller A Controller B BCC 1BCC 2BCC 2BCC 157689Single SPU, single array of two controllers & 2 JBODs, RAID-1SPUFC Adapter AFC Adapter BFCAL-BLVDSCSILVDSCSIFCAL-AOptimus Controller A Controller B Megatron
23、JBODBCC 2BCC 1BCC 1BCC 1BCC 2BCC 2LUN 01LUN 92345678Single SPU, single array of two controllers & 3 JBODs, RAID-5SPUFC Adapter AFC Adapter BFCAL-BFCAL-ALUN 0LUN 1LUN 2LUN 3LUN 4Optimus Controller A Controller B LUN 5LUN 6LUN 7Megatron JBODBCC 1BCC 1BCC 1BCC 1BCC 1BCC 1LUN 8LUN 9BCC 2BCC 2BCC 2BC
24、C 2BCC 2BCC 2Single SPU, single array of two controllers & 6 JBODs, RAID-5/opt/hparray/bin/AM60SrvrAM60Srvr Command UtilitiesDetailed man pages exist for each of these commands, and also for AM60Srvr.The Array Monitor Daemon (arraymond) monitors the system in regular intervalsCommand NameDescrip
25、tion amdspProvides information about the configuration and operating state of the array. ammgrConfigures the overall operating characteristics of the array, such as the Control Active, caching and active hot spare. amcfgmanages LUN (logical drive) configuration on the disk array amutilcontrols vario
26、us disk array management functions.Such as flash led. amrbldUsed to initiate, terminate and evaluate the rebuild of a disk in the array.amdsp -iThis command is used to display the serial numbers of all arrays known by the host. AM60Srvr commands typically require an , which is either the array seria
27、l number, or the arrays character device file name. You might then choose to command to set up a shorter identifier:# export a1= 0000C00A0B8090ECE OR # a1= 0000C00A0B8090ECEThe identifier $a1 can now be used to identify the array rather than typing in the lengthy serial number.# amdsp -iArrays known
28、 to the AM60Srvr: arrays with S/N: 0000C00A0B8090ECEDisplay array serial number(s):# amdsp -RRescan the bus:Find the array identifiers:# ioscan -fnC diskcommandsArraydsp Command SummaryCommands used to view array settingsamdsp的格式: amdsp amdspNo option, displays general array information.amdsp -iDisp
29、lays all arrays currently known by the host.amdsp -lDisplays LUN specific information.amdsp -dDisplays disk information.amdsp -sDisplays disk array state information.amdsp -aQuick view of all configuration and status information.amdsp -cDisplays controller information.amdsp -hDisplays hardware infor
30、mation.See Man pages for additional information on amdsp options Vendor ID = HP Product ID = A5277A Array ID = 000C00A0B8090ECE Array alias = array B)use SAM Manager FC60所以在运行条件具备的情况下,建议尽量减少开,关机次数,否则会影响系统的寿命。u HP 存储存储AUTORAIDu HP 存储存储FC60u HP 存储存储VA系列系列u HP 存储存储 DS2405u HP 存储存储EVA系列系列可用性可用性可扩展性和性能可扩
31、展性和性能HP surestore 的中档阵列产品的中档阵列产品1,080GB 容量容量15 个驱动器个驱动器800MB/sec 的背板的背板18、36、 73GB 10&15K FC 磁磁盘盘2.0 GB 高速缓存高速缓存2个个 100Mbs FC 端口(主机)端口(主机)64个个LUNVA 管理管理 软件软件7.7TB 容量容量105 个驱动器个驱动器800MB/sec 的背板的背板18、36、73GB 10&15K FC 磁盘磁盘2.0 GB 高速缓存高速缓存2个个 200Mbs FC 端端口(主机)口(主机)1024个个LUNVA 管理软件管理软件1Gb/s nativ
32、e fibre channel Performance: (read)90MB/s, 12.5K IOPs cache, 3K IOPs disk1GB cache per controller15 high performance disk drives3U in a standard 19” rack540GB 36.1 GB disks1.1TB 73GB disks HP-UX 11.0, 11i, MPE/iX 6.5, 7.0 (9/1), WinNT, Win2K, RH 6.2, 7.1, Solaris 7.0, 8.0, Netware, AIX nextMC/Servic
33、eGuard, Microsoft Cluster Services Certification pending (paperwork has been submitted)The VA 7100 -为中小企为中小企业的关键业务提供一个便捷的业的关键业务提供一个便捷的存储空间管理设备存储空间管理设备2Gb/s native fibre channel Performance: (read/write 45 Drive)180MB/s, 30K IOPs cache, 8K IOPs disk75MB/s, 30K IOPs cache, 4K IOPs disk1GB cache per co
34、ntroller105 high performance disk drives3U/encl. in a standard 19” rack3.8TB w/ 36.4GB disks7.7TB w/73GB disksHP-UX 11.0,11i, MPE/iX 6.5, 7.0 (9/1), WinNT, Win2K, RH 6.2, 7.1, Solaris 7.0, 8.0, Netware, AIX nextMC/ServiceGuardMicrosoft Cluster Services Certification pending (paperwork will submitted
35、 late July)The VA 7400 为中小企为中小企业的关键业务提供一个便捷业的关键业务提供一个便捷的存储空间管理设备的存储空间管理设备 *Use the point of a pencil, pen or similar object to access On/Off Switch *Reference designator actually used in Command ViewPower/Standby Switch*System Fault LED (Amber)System Power/ Activity LED (Green)Disk Drive Slot Number (1 of 15; 8 covered by HP label)Disk Drive (*D1 - D15)Disk Drive Fault LED (Amber)ESD Ground Plug (Banana Type)Disk Drive Activity LED (Green)*Reference designator actually used in Command ViewArray Controller Card 1 (*C1)HOST FC Port Connector 1 (*H1)FC Link LEDs (Upper
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年新能源汽车自动驾驶技术法规适应性研究进展与挑战报告
- 酒店安全培训记录模板课件
- 酒厂安全培训记录课件
- 考研物流工程与管理资料(3篇)
- 郭德纲的课件解读
- 新时代国家安全观测试题及答案解析
- 前置试题及答案
- 进厂安全培训课件内容
- 塑料模具工工艺考核试卷及答案
- 百万消防安全题库及答案解析
- 牙齿矫正方式对比
- 3.2 中国的矿产资源教学课件 初中地理湘教版(2024)八年级上册
- 学堂在线 高技术与现代局部战争 章节测试答案
- 无人机公司飞手管理制度
- 房地产抵押贷款合同电子版预览
- 公路机电安全培训课件
- DB42-T 2389-2025 陶粒沥青混凝土路面施工技术规程
- 25春国家开放大学《物流信息技术》形考任务1-4参考答案
- 2025年中国声卡市场现状分析及前景预测报告
- 新人教版七年级上数学第一单元测试卷及答案
- 《职场压力管理》课件
评论
0/150
提交评论