1、富士达电梯故障代码故障代码代码解析01输入异常:M-MIC输入信号异常06侯梯厅通信异常07侯梯厅通信异常08电源监控信号OFF11减速开关异常:LS101与LS201、LS11与LS21同时OFF132IR工作异常:2IR-1U、3U、3D、1D动作顺序异常14CTL/OTL动作异常153IR与LS101/201同位置时不动作163MS组合异常18在一次运行中,同一层选层器发生修正3次1C上部减速开关工作位置异常1D下部减速开关工作位置异常20速度控制异常检出下咼速禁止休止21超速23变频器BD动作25加速不良27轿厢位置数据偏差异常28轿厢速度数据偏差异常2A转距指令饱和:速度指令所需要转
2、距过大,以致不能计算2B扭距太大2D即将超速前2E检出逆行:运行方向与指令方向相反2F速度控制异常检出下启动禁止休止30咼速运转超时:实际运行时间与指定时间超差31低速运转超时:低速运行时间与指定时间超差33减速时间超时:减速运行时间超差37变频器过负载:检出主回路、马达过热、过载3D“直流段电压确认未打3E“直流段电压确认未关闭40再平层超速41再平层运转超时42再平层过度10MM以上43再平层运转次数超次44再平层超界60MM以上4E启动时超速4F启动时超界50终端发生强制减速51楼层选层器发生修正52运行中平安回路OFF58启动时制动器释放条件不成立59关门不良下启动失败5A预通电时超速
3、5B预通电时超界60MM 以上5C预通电时超界200MM以上5D检出逆行5F行走中运转方式异变64# B4打不开65# B4不关闭68# 1E不翻开69# 1E不关闭6A# 36不翻开6B# 36不关闭6C# 6不翻开6D# 6不关闭70不能开门下救出运转71不能开门下停止72门速度控制异常73启动时厅门装置不良78门未能翻开79门未能关闭7A3次检出门未能翻开7B屡次检出门未能关闭7F门开闭动作时间次速超过80MILLNET异常信息81MILLNET异常信息82MILLNET异常信息90SV对M-MIN 或其他电梯的 M-MIN 对M-MIN 通信中断AF负载感应器电压异常:超出变化范围B0
4、轿厢位置数据偏差大B1减速时间超时B2轿厢位置错位B3轿厢无法确认位置B4照明电源中断CO行走中不超过平层感应板CC# 6Z不翻开CD# 6Z不关闭DE# 6励磁前、# 6OFF是检查不可E1手动上行/下行按钮无法复位E4负载信号矛盾:负载感应器与4WC信号不一致E5指令上冲/下冲方向运转:LS动作后仍有咼速指令E7减速度限制中强制减速FFM-MIC再启动在安装富士达电梯时动慢车有时会发生故障造成电梯慢车不运行1、电机不得电-#36不吸合-#1E -未吸合造成2、电机得电但不开闸抱闸检测回路断开 - 故障 6 系3、电机得电但开闸不走 - 抱闸检测回路不断开 - 故障 6 系4、电梯在机房可以
5、走慢车在轿顶不运行 - 防撞头开工未封、 轿顶通讯不良呼叫记录开始:按动上按钮,同时将 EQDO 开关切到 ON ,然后放开。 实行:按动上按钮,上面的一层 按住 2 秒以上,顶层 即被预约。 按动下按钮,下面的一层 按住 2 秒以上,底层 即被预约。 按住中按钮,以上被预约的楼层即被记录下来。 保持按住中按钮,门将被关闭。结束:将 EQDO 开关切到 OFF 。安装运行开始:将轿顶、轿内的自动 / 手动开关均切换到自动位。按住下按钮,同时将 EQDO 开关切到 ON ,然后放开按钮。运转:按动上按钮,轿厢慢车向上。按动下按钮,轿厢慢车向下结束:将 EQDO 开关切到 OFF楼层选择器的错开开
6、始:按住上按钮,同时将 EQDO 开关切到 ON ,然后放开按钮实行:按动上按钮,上面的一层 按住 2 秒以上,顶层 即被预约按动下按钮,下面的一层 按住 2 秒以上,底层 即被预约按住中按钮,以上被预约的楼层上的选择器即错开结束:将 EQDO 开关切到 OFF在“呼叫记录, “楼层选择器的错开的实行过程中,所记录的呼叫楼层和选择器错开的楼层将会在 LED 的bit0bit7 上以 2 进制数显示出来。 操作开始之初显示的是当时轿厢所处的楼层bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 表示 -1-2-3-4-5-6-7-8-9-10-11-1
7、2平常表示【 SEL=0 数据 =0 】时 LED 的显示灯亮高速闪动低速闪动熄灭Bit7有工程代码无工程代码Bit6地震时管制运行火灾时,自备电,漏水时的管制停车运转平常Bit5与 IF61 , IF66 通信断开与 IF61 , IF66 通信正常Bit4与 SV ,其它号机通信断开与 SV ( MAIN ) 通信断开与 SV ,其它号机通信正常Bit3与 COB/ 候梯厅电脑通信断开*6与 COB/ 候梯厅电脑通信正常Bit2启动禁止高速运转禁止高速运转可能Bit1门关闭完成位置门中间位置门翻开完成位置Bit0门区内门区外富士达电梯控制屏操作方法【安装运行】开始:将轿顶、轿内的自动/手动
8、开关均切换到自动位。按住下按钮,同时将 EQDO开关切到ON,然后放开按钮。运转:按动上按钮,轿厢慢车向上。按动下按钮,轿厢慢车向下。结束:将EQDO开关切到 OFF。【呼叫记录】开始:按动上按钮,同时将 EQDO开关切到ON,然后放开。实行:按动上按钮,上面的一层按住 2秒以上,顶层即被预约。按动下按钮,下面的一层按住 2秒以上,底层即被预约。按住中按钮,以上被预约的楼层即被记录下来。保持按住中按钮,门将被关闭。结束:将EQDO开关切到 OFF。【楼层选择器的错开】开始:按住上按钮,同时将 EQDO开关切到ON,然后放开按钮实行:按动上按钮,上面的一层按住 2秒以上,顶层即被预约。按动下按钮
9、,下面的一层按住 2秒以上,底层即被预约。按住中按钮,以上被预约的楼层上的选择器即错开。结束:将EQDO开关切到OFF在“呼叫记录,“楼层选择器的错开的实行过程中,所记录的呼叫楼层和选择器错开的楼层将会在 LED的bit0bit7 上以2进制数显示出来。操作开始之初显示的是当时轿厢所处的楼层bit 7bit 6 bit 5 bit 4bit 3 bit 2bit 1bit 0 表示-_1_2-3-4-5-6-7-8-9-10-11-12平常表示【SEL=O数据=0】时LED的显示-灯亮高速闪动低速闪动熄火Bit7有工程代码无工程代码Bit6地震时管制运行火灾时,自备 电,漏水时的 管制停车运转
10、平常Bit5与 IF61 ,IF66 通信断开与 IF61 , IF66通信正常Bit4与SV ,其它号机通信断开与SVMAIN 通信断开与SV,其它号机通信正常Bit3与COB/候梯厅电脑通信断开*6与 COB/候梯厅电脑通信正常Bit2启动禁止高速运转禁止咼速运转可能Bit1门关闭完成位置门中间位置门翻开完成位置Bit0门区内门区外E411中文翻译故障灯1. DZ或ADZ 与MCSS的命令状态不一致2. 超过110%的额定速度3.终端超速4.SPPT 反应速度与 MCSS 指令速度差超过一定范围5.SPPT 反应速度与 PVT 反应速度之差大于一定值6.U. D 继电器状态与命令状态不一致
11、7.DZ 感应器故障,感应器坏于距平层 600ms 至 2000ms 之间检查三只感应器,感应器应在 OFF 状态8.SC 继电器状态与 MCSS 给出的指令不相符9.平安回路断开此时 EES 继电器应吸合10.拯救运行失败11.心脏跳动。 CIO 检查: DBD. FGDS. AGDS 未动作12.轿内急停开关动作13.DZ. ADZ 出现问题,在 MLS6 状态下 MCSS 对 DZ. ADZ 输出断开信号, ADZ DZ 未动作14.在门区外开门15.超出终端区域16.出现此故障时,需要更换 MCSS CPU 电脑板17.同上 EPROM 检查出错18.30V 电源故障至门区感应器, I
12、NA,SC 等继电器的反应的电源超出±6V,或无电源19.轿厢速度大于 125% 的初始化速度,而 SPPT 第二通道无此信号20.方向测试故障, U. D 继电器状态与 PVT 反应方向不一致21.加拿大标准。不用22.加拿大标准。不用23.ETSD 与 MCSS 所给出的状态不一致24.CIO 测试时,轿内急停开关未处于低电平状态25.检修继电器故障,同上 CIO 测试时 INA 未动作26.门回路检查故障,同上说明 FGDS1 ,FGDS2 未动作27.2732不用33.MCSS 上修改数据开关 SWZ 1 处于开状态,打外呼时出此故障34.DBSS发出信号给MCSS , DB
13、SS坏。MCSS输出信号EES让其断开35.无效的抱闸状态, MCSSDBSS 翻开抱闸 3 秒内无反应,开关坏线圈坏 ABB 不吸36.准备运行无效 DBL 重置翻开抱闸建立磁场37.DBD 信号无效 DBD 应在 MLS3 MLS10 运行逻辑模式中为低电平38.抱闸提升超时 3 分钟39.GS 监测超时,先收到 DCL 信号,而未收到 GS 信号40.初始化运行失败,初始化运行超过 30 秒而电梯仍未寻到位置,注意 SPPT 好否41.位置出错,SPPT二只通道传输回来的位置信号不一致42.低电压故障,J2继电器动作63.DBSS 故障同 34 一起亮LCBII, OCSS, TCBC等
14、电子板的I/O输入输出口上下电平转换设置:设高电平有效:M-1-3-2,输入要改的I/O地址,输入100,按蓝键-1-蓝键-ENTER,再设回原来的地址。设低电平有效:M-1-3-2,输入要改的I/O地址,输入000,按蓝键-1-蓝键-ENTER,再设回原来的地址。电梯不要停在顶层打上检修短接JP9-1JP9-5进入变频器a变频器窗口显示“ Moiltor 按“显示“Starup 按“Enter用“ 找到显示“ Starup config 按“Enter 显示“Drivedata 变频器参数按“ 显示“ Motor data 马达参数按“ 显示“ Autotune 自学习按“ Enter 用“
15、 找到显示“ Complete stillStart ? 按“ Enter 显示“ Complete still Press I key d按“ 启动键,显示保存就可以了XH5帀明科电梯吾业躺 电梯即能【匸k电悌術纹 电梯液晶韜示电押舉媒佯 电梯尙椚裝饰电欄到站灯post/postMCSS PARAMETERSSPEC-90, E311EEPROM SETTING MANUAL VER. 2.5M - 2 - 3 INST = 1 Top floorjobtopfloor number ( <=bottomfloor+53 )Bottom floorjobbottom floor num
16、ber ( >= 0 )Country AJG10 =NAO,1 = JAPAN,2 =ETOENABLE ADONY(0)0= DISABLE,1 =ENABLEENABLE RELEVEL10= DISABLE,1 = ENABLEADV BRK LIFT00 =DISABLE,1 = ENABLE( NOTUSED )DBSS PARITY00 = ODD,1 =EVENCAR NON START20 sMax,permissible time fordetecting door zone of next floor when running ( not used )MAN. DE
17、CEL TIME0( not used in Japan )No. of DZ in 1LS1Number of door zone vane in 1LSzoneNo. of DZ in 2LS1Number of door zone vane in 2LSzoneAbs. overspd % NOR110%Ultra over-speed detectionpermissible % at normal runningAbs. overspd % INS 130 % permissible % at inspection runningAbs. overspd % REC 150 % pe
18、rmissible % at recover runningAbs. overspd % REI 150 % permissible % at reinitialize runningUltraover-speeddetectionUltraover-speeddetectionUltraover-speeddetectionUltra over-speed detectionTrack err % NOR 25% at normal and reinitialize runningActual speed error permissible %Track err % INS50% Actua
19、l speed error permissible % atinspection and recover runningTrack err % LOW 255 %Actual speed error permissible %Abs. overspd % JPSDO120 % permissible % at terminal floor running on JPSDOat relevel and learn runningNTSD percent 100%Permissiblespeed at 1LS / 2LSdetection ( % of Normal speed )ETSD per
20、cent95 %ETSD relay control speed ( % ofNor. speed )Enable ETSD1 0 =disable, 1 =enable ( relayfaultdetection )PTR drop delay10msTiming forprepare-to-rundrop60 : sky linearmax. abs. overspd 10 from max. over-speed error max. track retry 50 tracking errormax. NTSD faults 10 from NTSD faultmax. ETSD fau
21、lts 10 ETSD faultmax. tract loss 10 traction loss error.max. UX, DX fault 50 from U / D relay errormax. pos faults50position faultmax. PVT faults50PVT faultmax. ADO retries 50 from ADO faultmax. EES faults0max. rdyrun timeout 50permissible number of recoverypermissible number of recovery frompermiss
22、ible number of recoverypermissible number of recovery frompermissible number of recovery frompermissible number of recoverypermissible number of recovery frompermissible number of recovery frompermissible number of recoveryEES fault ( not used in Japan )permissible number of recoveryfrom ready-to-ru
23、n timeout errormax. brake timeout50 permissible number of recoveryfrom brake lift / drop timeout errormax. adv. brk flt0 Advanced brake lift fault ( notused )max. drive fault 50permissible number of recovery fromdrive faultNote: permissible number of recoverybecomes limitless when 0 is setmax. relev
24、el run5 permissible number of relevel ( limit ofcontinuous relevel on the same floor )measure task no. 0spot )for technical test ( not used on the PROFILE = 2 mm/sVelocity normaljobmax. velocity at normal runningAccelerationnormaljobmax. acceleration at normalrunningJerk normaljobmax. jerk at normal
25、 runningrunningAccel. inspection200max. acceleration at inspectionrunningvelocity learn100max. velocity at learn runningaccel. learn500max. acceleration at learn runningvelocity relevel30max. velocity at relevel runningaccel. relevel300max. acceleration at relevel runningvelocity recover100max. velo
26、city at recover runningaccel. recover500max. acceleration at recover runningvelocity slow100medium velocity at deceleration andreaching to floor at reinitialize runningvelocity reinitjobmax. velocity at reinitialize runningaccel. reinitjobdeceleration from 1LS / 2LS at reinitializerunningaccel. NTSD
27、jobdeceleration for velocity limit at NTSDfor calculating the set distance of 1LS / 2LSJerk timed job max. jerk for forced deceleration and stoppingVELOC profile 2 job max. velocity for secondary fire fighting operation of emergency elevatorACCEL profile 2jobmax. acceleration for secondary firefight
28、ing operation of emergency elevator.JERK profile 2 job max. jerk for secondary fire fighting operation of emergency elevator.Note : VELOC 2, ACCEL 2, JERK 2 are set in the same way as the set valueat normal running. Provided that only VELOC 2 isset to 1500 mm / sfor models having a normal velocity o
29、f 1750 mm /s.VELOC profile 3joboperation for nonstop floors. ACCEL profile 3 job control operation for nonstop floors. JERK profile 3 job operation for nonstop floors.max. velocity of earthquake controlmax. acceleration at earthquakeMax. jerk at earthquake controlNote : Job which has nonstop floors
30、that elevator cannot decelerate or stopwithin 10 seconds is used at earthquake controloperation. ACCEL3and JERK3 are set in the same way as the set valueat normal runningand VELOCto 750 mm / s. For models having 500mm/s, VELOC is setto 500 mm/s .velocity zero 5velocity to be judged as stopping( site
31、 final adjustment value 3 mm/s )JPSDO type 20 : T = JPSDO for only top terminal1 : T = JPSDO for only bottom terminal2 : T = JPSDO for all terminal velocity JPSDO job terminal floor velocity of JPSDO Note: set terminal floor velocity for w / JPSDOjob only. JPSDO not functioned whenset to 0.gain fixe
32、d posct 20gain value of fixed gain positioncontrol at deceleration and stopping delta TC ms 30 discrete input ( DZ sensor, etc ) decel / accel %100 %accelerationdestination lead0 mmposition to this side of the level destination lag 5 mm 10 / s Control delay time due to delayedpercentage of decelerat
33、ion tovalue to adjust target stoppingvalue to adjust target stoppingposition to beyond the levelSite final adjustment value ( 3 mm )level tolerance5 mmdistance to be judged as the levelSite final adjustment value ( 3 mm )zero speed time0 mstime from zero velocity detectionto brake cut-off commandBKL
34、 to MOV timeout 0 ms time from brake release completion to start of velocity command output ( x10 ms )position misplmt0 mm positional error correction valuedue to delayed input response of DZ1 / DZ21LS/2LS tolerance 200 mmtolerance of fitting positiondetection distance of 1LS / 2LSslippage tolerance
35、 200 mm tolerance of detection distance due to rope slippage and vane positioncounts per revolution pprrated pulse number of PVT1024 spec-902500 sky linearmotor speed job motor speed ( rpm ) at rated velocity LANDINGS = 3 Front and back door control and setting of floors to which elevator isarrivabl
36、e.Set to1Set to0 LOAD = 4 Load device type0 : Spec - 901 : E311 VFsent fromfor floor which has a opening on that floor. will disable door opening on that floor.2 : Sky LinearLWT0 : corresponding to switch input of DISS,- sends LOAD VALUE % to DBSS- sends LOAD STATUS to OCSS1 : corresponding to LOAD
37、amount of LWTADISS,- sends LOAD % to DBSS- sends LOAD STATUS to OCSS2 : adding imbalance amount to LOAD amount ofsent from ADISS,- sends LOAD % to DBSS- sends LOAD STATUS to OCSS3 : corresponding to LOAD amount of LWT sentfrom127 % )to DBSS, (NOTES :OCSS load infoOCSS.OCSSDBSS load infoDBSSDBSS- ANS
38、 load %- Default value % 25DBSS when LWX input- Peak load value 0 %- Full load value % 50DBSS when LNS inputADISS,- sends bias torque amount- sends LOAD STATUS to OCSS.0 : sends value from device type to1 : sends always LOAD DEFAULT to0 : sends value from device type to1 : sends always balance load
39、value to0 % not input to DISS%load percent sent toby DISSnot input to DISS% Load percent sent toby DISSwhen LWOinput by DISSNote : These values are set to use DISS switch input for bias torque toDBSS.- offset adjust( sends to DISS )- Gain adjust( sends to DISS )- Imb. comp. factor bottom and top flo
40、or- % overbalance counterweightNo load correction of LWTMax. load correction of LWT difference of measurements of at full load.Over balance value of car and45 % : Spec - 90 / E 311 VF47 % : Spec 90 w /o Mexico50 % : Sky LinearNotes LWT : Load weighing TransducerWhen load device type is 2, offset adj
41、ust and, gain adjust imb, comp.factor are automatically adjusted by learning function but can also be set, changed or finely adjusted manually. ( see service tool manual LMCSS_SVT_V25 )Notes on job settingFactory set distance from terminal floor level of 1LS / 2LS andSS1 / SS2 switch is calculated f
42、rom the following equation :NTSD ( 1LS / 2LS ) set distance =( velocity normalmm /s ) 22x( accel NTSD mm /s2 )ACCEL NTSD generally has the same value as ACCEL NORMAL set, and a10-mm order figure of the obtained value is raised for setting.ETSD ( SS1 / SS2 ) set distance = ( velocity normal mm/s x ET
43、SD % ) 22 x ( accel reinitmm/s2 )For models generally has the same value as ACCEL NORMAL + 200 mm/s2 set, and 10mm or smaller of the value is discarded for setting. For slow velocity models ( 500 mm/s ) and E311 VF, the value is set to be smaller so as not to interfere with NTSD ( 1LS / 2 LS ) switc
44、h.ENABLE ADO ( advance door open ) is added only when required by abstract sales order,SKY LINEAR / E311VF needs adjustment on the spot as it uses load weighing transducer ( LWT ).Motor speed of SKY LINEAR is a number of revolution of PVT at a constant velocity and was calculated from the following
45、equation :motor speed ( TLIM ) = velocity normal (mm/s) x 60 ( rpm )PVT roller dia. (mm) xPVT roller dia. = 116 mmFor service job with JPSDO ( terminal floor forced deceleration function ),JPSDO SPEED is set with a1000, 1500, 1500 velocity slower by onelevel from each VELOC. NORMAL ( 1750500 mm/s ).
46、 In this case, forACCEL and JERK, NORMAL value is750, 750 1000 applied.And the set distance of 1LS/2LS and SS1/SS2 is a distance determined at normal velocity.For emergency elevator, a velocity at secondary fire fighting operation is specified by VELOC, ACCEL and JERK of profile 2.Velocity normal( m
47、m/s )VELOC profile 2(mm/s ) ACCEL profile 2( mm/s ) JERK profile 2( mm/s3)5005004004007507505005001000100060060015001500700700175015007007002000150080080025001500800800Velocity which is used at earthquake control operation by job which hassuch many nonstop floors that elevator cannot decelerate or s
48、top within10 seconds is specified by VELOC, ACCEL of JERK of profile 3.VelocitynormalVelocprofile3accelprofile3jerk profile 350050040040075075050050010007506006001500750700700175075070070020007508008002500750800800For profile 2 and profile 3, all models have a set value corresponding to a rated velo
49、city set at factory.As E311 VF is a geared elevator and6 x 2 - WF20 2.98 Kg/m ) is used, sothat imbalance for compensation chain (each floor is not taken intoaccount for bias torque to DBSS.Set value for each duty1. Set value for Spec-90 ( 13 VTR )Normal mm/s Normal mm/s2 Normal mm/s3 speed (rpm) NT
50、SD mm/s2 Reinit mm/s Reinit mm/s2 Timed mm/s3 2LS set pos. mm SS2 pos. mmAccel.JerkMotorAccelVelocAccelJerk1LS /SS1 /J13VTA0002A7505005001110500 500700700570370j13VTA0003A10006006001171600 600800700840600J13VTA0012A7505005001110500 500700700570370J13VTA0013A10006006001171600 600800700840600J13VTA0014A1500700700901700 100090070016101200J13VTA0015A17507007001051700 130090070021901690J13VTA0026A5004004001037400 300600700350150J13VTA
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 自行车服务在历史文化街区的融合考核试卷
- 花卉种植的园林景观植物养护考核试卷
- 2025年工业炉窑的新型燃烧装置项目建议书
- 橡胶板在电梯门挡板中的安全性能考核试卷
- 品牌营销实际流程策划
- 环保专业知识课件
- 中医骨伤科学多媒体课件-中医骨伤科学
- 2025年石英玻璃纤维套管项目建议书
- 福建高二考试试题及答案
- 嘉定国资委考试试题及答案
- 庭院造园行业分析
- 口腔医学技术:牙齿熔模的制作
- 保险理赔赔偿协议书
- 公交司机礼仪服务培训课件
- 钢笔的正确使用方法课件
- 空调冷热(冷却)水系统安装(金属管道)检验批质量验收记录(新表)
- 生物质燃气的制备及利用
- 2024年国家人民卫生出版社有限公司招聘笔试参考题库含答案解析
- 家庭与生活环境职业生涯规划
- 居家养老上门服务投标方案(技术方案)
- 压裂工程技术及安全环保措施
评论
0/150
提交评论