




版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、打开交换机端口,查看ip地址首先等入交换机 ip 192.168.70.129brocade8Gb:USERID> switchshowswitchName: brocade8GbswitchType: 73.6switchState: Online switchMode: NativeswitchRole: PrincipalswitchDomain: 1switchId: fffc01switchWwn: 10:00:00:27:f8:66:79:03zoning: OFFswitchBeacon: OFFIndex Port Address Media Speed State Pr
2、oto= 0 0 010000 id N8 No_Light FC Disabled (Persistent) 1 1 010100 cu N8 Online FC F-Port 10:00:00:90:fa:17:dc:20 2 2 010200 cu N8 Online FC F-Port 10:00:00:90:fa:17:dd:d2 3 3 010300 cu N8 Online FC F-Port 10:00:00:90:fa:17:db:a0 4 4 010400 cu N8 Online FC F-Port 10:00:00:90:fa:17:33:1a 5 5 010500 c
3、u N8 Online FC F-Port 10:00:00:90:fa:17:de:28 6 6 010600 cu N8 Online FC F-Port 10:00:00:90:fa:17:dc:80 7 7 010700 cu N8 Online FC F-Port 10:00:00:90:fa:17:de:48 8 8 010800 cu N8 Online FC F-Port 10:00:00:90:fa:17:de:02 9 9 010900 cu N8 Online FC F-Port 10:00:00:90:fa:17:dd:2a 10 10 010a00 cu N8 Onl
4、ine FC F-Port 10:00:00:90:fa:17:dc:e6 11 11 010b00 cu N8 Online FC F-Port 10:00:00:90:fa:17:30:dc 12 12 010c00 cu N8 Online FC F-Port 10:00:00:90:fa:17:de:10 13 13 010d00 cu N8 Online FC F-Port 10:00:00:90:fa:17:dc:0a 14 14 010e00 cu N8 Online FC F-Port 10:00:00:90:fa:17:33:82 15 15 010f00 id N8 No_
5、Light FC Disabled (Persistent) 16 16 011000 - N8 No_Module FC Disabled (Persistent) 17 17 011100 - N8 No_Module FC Disabled (Persistent) 18 18 011200 - N8 No_Module FC Disabled (Persistent) 19 19 011300 - N8 No_Module FC Disabled (Persistent)brocade8Gb:USERID> version 查看版本Kernel: 2.6.14.2 Fabric
6、OS: v6.4.2b4Made on: Thu Aug 9 21:10:00 2012Flash: Fri Mar 15 14:33:49 2013BootProm: 1.0.9brocade8Gb:USERID> switchdisable 关闭交换机模式brocade8Gb:USERID> ag -modeenable开启ag模式WARNING: Access Gateway mode changes the standard behavior of the switch. Please check Access Gateway Administrator's Gui
7、de before proceeding.Enabling agmode will remove all the configuration data on the switchincluding zoning configuration and security database. Please backup yourconfiguration using configupload.This operation will reboot the switch.Do you want to continue? (yes, y, no, n): no y这个时候会提示重新启动Access Gate
8、way mode was enabled successfullySwitch is being rebooted.客户只有在0号段口上有一根尾纤,这里做的都是把端口全部绑定在0号口上由于关闭了交换机模式,交换机上无法再显示wwn号了.brocade8Gb:USERID> switchshowswitchName: brocade8GbswitchType: 73.6switchState: Online switchMode: Access Gateway ModeswitchWwn: 10:00:00:27:f8:66:bd:d8switchBeacon: OFFIndex Port
9、 Address Media Speed State Proto= 0 0 010000 id N8 No_Light FC 1 1 010100 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 2 2 010200 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 3 3 010300 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 4 4 010400 cu AN No_Sync FC Disabled (N-Po
10、rt Offline for F-Port) 5 5 010500 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 6 6 010600 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 7 7 010700 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 8 8 010800 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 9 9 010900 cu AN
11、No_Sync FC Disabled (N-Port Offline for F-Port) 10 10 010a00 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 11 11 010b00 cu AN No_Sync FC 12 12 010c00 cu AN No_Sync FC 13 13 010d00 cu AN No_Sync FC 14 14 010e00 cu AN No_Sync FC 15 15 010f00 id N8 No_Light FC 16 16 011000 - N8 No_Module FC 17
12、17 011100 - N8 No_Module FC 18 18 011200 - N8 No_Module FC 19 19 011300 - N8 No_Module FC brocade8Gb:USERID> LOCAL : SEND0: window-change (rows: 24, cols: 80) brocade8Gb:USERID> ag mapshow 这个是默认的设置N_Port Configured_F_Ports Current_F_Ports Failover Failback PG_ID PG_Name- 0 1;2 None 1 1 0 pg0 1
13、5 3;4 None 1 1 0 pg0 16 5;6;7 None 1 1 0 pg0 17 8;9 None 1 1 0 pg0 18 10;11 None 1 1 0 pg0 19 12;13;14 None 1 1 0 pg0-brocade8Gb:USERID> ag -mapdel 15 "3;4"F_Port to N_Port mapping has been updated successfullybrocade8Gb:USERID> ag -mapdel 16 "5;6;7"F_Port to N_Port mapping
14、 has been updated successfullybrocade8Gb:USERID> ag -mapdel 17 "8;9" F_Port to N_Port mapping has been updated successfullybrocade8Gb:USERID> ag -mapdel 18 "10;11"F_Port to N_Port mapping has been updated successfullybrocade8Gb:USERID> ag -mapdel 19 "12;13;14"F
15、_Port to N_Port mapping has been updated successfullybrocade8Gb:USERID> ag -mapadd 0"3;4;5;6;7;8;9;10;11;12;13;14"要注意空格USAGE: ag -mapadd <N_Port> "< fport; fport >" Adds specified list of F_Ports to the mapping for a given N_Port. It will add the current to the exi
16、sting mappings if any for that N_Port. An F_Port cannot be mapped to more than one N_Port at the same timebrocade8Gb:USERID> ag -mapadd 0"3;4" USAGE: ag -mapadd <N_Port> "< fport; fport >" Adds specified list of F_Ports to the mapping for a given N_Port. It will ad
17、d the current to the existing mappings if any for that N_Port. An F_Port cannot be mapped to more than one N_Port at the same timebrocade8Gb:USERID> ag -mapadd 0 "3;4;5;6;7;8;9;10;11;12;13;14"F_Port to N_Port mapping has been updated successfully 成功brocade8Gb:USERID> ag -mapshowN_Por
18、t Configured_F_Ports Current_F_Ports Failover Failback PG_ID PG_Name- 0 1;2;3;4;5; None 1 1 0 pg0 6;7;8;9;10; 11;12;13;14 15 None None 1 1 0 pg0 16 None None 1 1 0 pg0 17 None None 1 1 0 pg0 18 None None 1 1 0 pg0 19 None None 1 1 0 pg0brocade8Gb:USERID> switchshowswitchName: brocade8GbswitchType
19、: 73.6switchState: Online switchMode: Access Gateway ModeswitchWwn: 10:00:00:27:f8:66:c1:ddswitchBeacon: OFFIndex Port Address Media Speed State Proto= 0 0 010000 id N8 No_Light FC 1 1 010100 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 2 2 010200 cu AN No_Sync FC Disabled (N-Port Offline f
20、or F-Port) 3 3 010300 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 4 4 010400 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 5 5 010500 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 6 6 010600 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 7 7 010700 cu AN No_Sync FC D
21、isabled (N-Port Offline for F-Port) 8 8 010800 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 9 9 010900 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 10 10 010a00 cu AN No_Sync FC Disabled (N-Port Offline for F-Port) 11 11 010b00 cu AN No_Sync FC 12 12 010c00 cu AN No_Sync FC 13 13 0
22、10d00 cu AN No_Sync FC 14 14 010e00 cu AN No_Sync FC 15 15 010f00 id N8 No_Light FC 16 16 011000 - N8 No_Module FC 17 17 011100 - N8 No_Module FC 18 18 011200 - N8 No_Module FC 19 19 011300 - N8 No_Module FCbrocade8Gb:USERID> portenable 0 打开端口 或是switchenablebrocade8Gb:USERID> switchshowswitchN
23、ame: brocade8GbswitchType: 73.6switchState: Online switchMode: Access Gateway ModeswitchWwn: 10:00:00:27:f8:66:bd:d8switchBeacon: OFFIndex Port Address Media Speed State Proto= 0 0 010000 id N4 Online FC N-Port 20:0c:00:0d:ec:c1:f1:41 0x7a002b 1 1 010100 cu N8 Online FC F-Port 10:00:00:90:fa:17:32:fe 0x7a003d 2 2 010200 cu N8 Online FC F-Port 10:00:00:90:fa:17:db:ea 0x7a003e 3 3 010300 cu N8 Online FC F-Port 1
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年国内知名企业数据分析师岗位招聘面试题及答案
- 2025年人事专员面试问题及模拟题答案
- 2025年健康照护师专业资格认证考试模拟题及答案
- 2025年旋挖钻机项目建议书
- 2025年口服降血糖药项目建议书
- 2025年生物质气化机组项目建议书
- 抛光粉尘安全知识培训课件
- 抗过敏药课件
- 广西南宁市西乡塘区、江南区2024-2025学年七年级下学期期末检测地理试卷(含答案)
- 2025年电视节目自动播出设备项目建议书
- 2025年秋季第一学期开学典礼校长致辞:在历史的坐标上接好时代的接力棒(1945→2025→未来:我们的责任接力)
- 中国邮政集团工作人员招聘考试笔试试题(含答案)
- 工程竣工移交单(移交甲方、物业)
- 2025年高考语文全国一卷试题真题及答案详解(精校打印)
- 《预防未成年人犯罪》课件(图文)
- 义务教育语文课程标准(2022)测试题带答案(20套)
- 腰丛和坐骨神经阻滞
- 农业气象观测规范-土壤水分分册
- 交通运输安全常识
- 1、人社部《一体化课程开发技术规程》
- NRC-2012 猪的饲养标准Excel终极版
评论
0/150
提交评论