




版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、摘要本文主要介绍了原平市综合办税楼的设计.在设计中,认真贯彻了“适用、安全、美观”的设计原则,进一步掌握了与结构设计全过程、基本方法和步骤。本设计主要包括设计和结构设计两部分。设计,包括平面图设计、平面设计、立面设计、剖面设计。结构设计,框架结构设计主要包括:结构选型,梁、柱、墙等构件的确定,重力荷载计算、横向水平作用下框架结构的内力和侧移计算、纵向作用计算、水平作用下横向框架内力分析、竖向荷载作用下横向框架的内力分析、内力组合、截面设计、基础设计。在设计的过程中我严格按照最范及有关规定进行设计,其中采用的计算方法均参照有关数据。办公楼楼设计 , 框架结构 , 结构计算ABSTRACThe d
2、esign projection for graduation is the last practice teaching segment of study of our specialized courses. In this paper a select scheme in bid for the planning design of a high school office building.This design mainly includes the architectural design and structural design. The architectural desig
3、n includes the plane fixed position drawing design,the plane drawing design and sign to face the design, section design. The structure design, the mission of the frame structural design mainly have: the type selection ,the size of beams、pillars、walls etc., the gravity load calculation, the calculati
4、on of internal force and lateral moving in the function of the horizontal force, lengthways earthquake function calculation, the internal force analysis of the crosswise frame in the function of the horizontal earthquakes, the internal force analysis of the crosswise frame in the function of the ver
5、tical load and also includes the dint combine、section design、foundation design.Had seriously carried out the code of design :“fitting、safety、economical、beautiful outlook”and the basic measure and procedure in the whole design of architecture and structure.Keywordsoffice building ,Frame structure , s
6、tructural calculation 工程概况1工程概况(1)本工程总面积 4909.20m2。其中: 地上部分面积为 3973.48m2部分面积为 935.72m2。高度:17.1m,层数:地上 4 层,1 层。一层层高:3.0m(5.45m)一层层高:3.9m;二、四、三层层高:3.6m;五层层高:4.5m(4.1m)。(2)本工程为多层,耐火等级地上,为一级。结构形式为钢筋混凝土框架结构,具体设计参数详见图。(3)结构各类活荷载取值依据结构荷载规范GB50009,基本雪压:So=0.30kN/m2,基本风压: Wo=0.5kN/m2,地面粗糙度:B 类。场地标准冻深:0.56m。设
7、计采用的均布活荷载标准值注: 本表未注明的房间活荷载详见结构荷载规范(GB 50009-2001)表 4.1.1.1.大型设备按实际荷载值取用;其它房间活荷载标准值均不得大于各设计图纸中的设计要求。2.技术鉴定或设计,不得改变结构的用途和使用环境。2、工程地质条件(1) 本工程根据<<场地岩土工程勘察报告>进行设计,拟建场地自上而下各土层的工程地质特征如下:(2)水本次勘探深度范围内未场地水。本场地地基土对混凝土结构和钢筋混凝土结构中的钢筋具有微腐蚀性。(3)场地土的类型本场地可按非液化场地考虑,对地不考虑湿陷。3、建设地区自然条件抗震属一般地段,可不考虑震陷影响,本场(1)
8、 冬期持续时间:10 月 23 日至 3 月 5 日(2) 主导风向:北风(3) 雨季为 7、8、9 月4、建设地区技术条件:(1)工程施工企业资质:具有土建工程施工总承包资质;(2)主要施工机械及技术装备情况;具有各类常用机械;(3)施工用水情况:城市供水接用;(4)施工用电情况:有城市电网接用,加设变压器;(5)材料、设备的供应情况:按计划保证供用;(6)施工地区劳动力的供应情况:按计划组织劳动力市场,满足供应;(7)施工地区的供应道路及工具:主要采用汽车。2. 工程做法2.1. 屋面做法: 自下而上依次为:20mm 厚 C30 粗砂粒料保护层4mm 厚 SBS 改性沥青防水材料2mm 厚
9、聚氨酯防水涂膜20mm 厚 1:2.5 水泥砂浆找平层30mm 厚 1:6 水泥焦渣找坡50mm 厚挤塑聚苯板20mm 厚 1:3 水泥砂浆找平120mm 厚现浇钢筋混凝土屋面板2.2. 楼地面做法2.2.1. 房间,走道,楼梯间楼面(铺地砖楼面楼面) 自下而上依次为:10mm 厚水磨石面层20mm 厚 1:4 干硬性水泥砂浆10mm 厚素水泥浆结合层一遍20mm 厚 1:3 水泥砂浆找平层120mm 厚现浇钢筋混凝土楼板2.2.2. 卫生间楼面(防滑地砖楼面) 自下而上依次为:10mm 厚防滑地砖铺实拍平,水泥擦缝25mm 厚 1:4 干硬水泥砂浆结合层15mm 厚聚氨酯防水材料15mm 厚
10、 1:3 水泥砂浆找平60mm 厚细石混凝土找坡120mm 厚现浇钢筋混凝土楼板2.2.3. 门厅楼面(花岗石板楼面) 自下而上依次为:20mm 厚花岗石板铺实拍平,水泥浆裁缝30mm 厚 1:4 干硬性水泥砂浆120mm 厚现浇钢筋混凝土楼板2.2.4.间楼面(水泥砂浆防水楼面)15mm 厚 1:2.2 水泥砂浆35mm 厚 C15 细石混凝土15mm 厚聚氨酯防水层20mm 厚 1:3 水泥砂浆找平水泥浆一道120mm 厚钢筋混凝土楼板2.2.5.室(配电室)自下而上依次为:20mm 厚 1:25 水泥砂浆抹面压光素水泥浆一道80mm 厚 C15 混凝土垫层灰土垫层120mm 厚钢筋混凝土
11、板底2.2.6.室(用于消防水泵房)20mm 厚 1:2.5 水泥砂浆抹面压光素水泥浆结合层一道60mm 厚 C15 细石混凝土防水层向排水沟找坡80mm 厚 C15 混凝土垫层灰土垫层120mm 厚钢筋混凝土底板2.3.墙身做法2.3.1.外做法a. 喷涂料外墙喷外墙涂料二道封底涂料5mm 厚聚合物抗裂砂浆,内置耐碱玻纤网络步聚合物粘结剂黏贴,3 厚岩棉板,锚栓加固15mm 厚 1:3 水泥砂浆找平层专业界面处理剂一道b. 石材外墙钢筋混凝土外墙(加气混凝土砌块墙) 35mm 厚岩棉板5mm 厚聚合物抗裂砂浆,压入两次耐碱玻纤网络布12mm 厚聚氨酯防水涂料30mm 厚石质板材2.3.2.内
12、a.乳胶漆做法(房间,走道,楼梯间等处),自外而内依次为:白色内墙涂料5mm 厚 1:0.3:2.5 水泥石灰膏砂浆抹面,压实抹光6mm 厚 1:1:6 水泥石灰膏砂浆抹平扫毛6mm 厚 1:0.5:4 水泥石灰膏砂浆打底扫毛加气混凝土界面处里剂一道b.釉面砖(卫生间内墙),自外而内依次为:5mm 厚釉面砖,白水泥擦缝5mm 厚聚合物防水砂浆素水泥浆一遍15mm 厚 1:3 水泥砂浆打底扫毛刷专业界面处理剂一道c.花岗石板(一层门厅)30mm 厚 1:2.5 水泥砂浆分层灌浆20mm 厚石质板材水泥擦缝d.水泥砂浆(室)喷内墙涂料5mm 厚 1:2 水泥砂浆抹面,压实赶光15mm 厚 1:3
13、水泥砂浆打底刷专业界面处理剂一道2.4. 顶棚做法2.4.1. 水泥砂浆顶棚( 表面喷刷涂料室)5mm 厚 EC 聚合物砂浆保护层,内置玻纤网络布黏贴 20mm 厚岩棉板,专业粘结刷素水泥浆一遍2.4.2. 轻钢龙骨纸面石膏板吊顶(门厅、走道) 表面装饰配套防潮涂料一遍9mm 厚 900*2700 纸面石膏板轻钢龙骨标准骨2.4.3. 铝合金方板吸音吊顶(卫生间)1 厚铝合金穿孔方板铝合金横撑铝合金中龙骨大龙骨龙骨档内填 50 厚岩棉吸音,用直径为 8mm 螺栓吊杆,双向吊顶丝布包好钢筋混凝土板内预留直径为 6mm 铁环双向吊点2.4.4.其它吊顶刷乳胶漆5 厚 1:0.3:2.5 水泥石灰膏
14、砂浆抹面5 厚 1:0.3:3 水泥石灰膏砂浆打底扫毛刷素水泥浆一道钢筋混凝土楼板底二 结构设计部分1.结构平面布置及结构计算见图的确定1.1.结构平面布置及结构的承重方案1.1.1.结构的平面布置本企业生产综合楼采用的边跨为 7.2m,中间跨为 3m,各层层高由层高确定,其中底层结构层高从基础顶面算起。室内外高差为 1.2m,并取室外地面到基础顶面的距离外-0.5m,故各层的结构层高分别为:一层 3.5m,一层 3.9m,二、三层 3.6m,四层 4.1m。柱网布置图如下图所示,柱网布置图1.1.2.框架结构承重方案的选择:本方案中竖向荷载的传力途径:楼板的均布活荷载和恒荷载经次梁直接或间接
15、的传至主梁,再由主梁传至框架柱,并由框架柱传递给基础,最后传至地基。根据以上楼盖的平面布置及竖向荷载的传力途径,本办公楼框架的承重方案采用横向框架承重方案,这可使横向框架梁的界面高度达,增加框架的横向侧移刚度。1.2.确定梁柱界面及结构计算简图1.2.1.柱截面的确定:框架柱截面根据柱的轴压比限值确定,可按下列公式计算:(1)柱截面面积Ac ³ Nc / (Un ´ fc )式中:Un轴压比限值fc混凝土的轴心抗压强度设计值Nc柱轴压设计值(2)柱轴力设计值Nc =1.25C b N式中:N竖向荷载作用下柱轴力标准值(包含活荷载)b水平作用对柱轴力的放大系数,七度抗震b =
16、1.05;八度抗震b =1.0C系数。中柱 C=1.0;边柱 C=1.1;角柱 C=1.2(3)竖向荷载作用下柱轴力标准值N = nAq式中:n柱承受楼层数A柱子的从属面积q竖向荷载标注值(包含活荷载),对于框架结构:q 取 1214 KN / m2(4)查抗震设计规范可知,该场地类别为 III 类,抗震设防烈度为7 度(0.10g),现浇混凝土框架结构,高度在 30m 以下,则其抗震等级为三级,其轴压比限值U n = 0.85 。底层中柱:A = 7.2´(3 2 + 7.2 2) = 36.72mm2N = nAq = 5´ 36.72´12 = 2203.2
17、KNNc = 1.25CbN = 1.25´1.0´1.05´ 2203.2 = 2891.7KNA = N(U f ) = 2891.7 ´103 (0.85´14.3) = 237902.1mm2ccn cAc =237902.1 = 487.75mm底层边柱:A = 7.2´ 3.6 = 25.92mm2N = nAq = 5´ 25.92´12 = 1555.2KNNc = 1.25CbN = 1.25´1.1´1.05´1555.2 = 2245.32KNA = N(U f
18、) = 2245.32´103 (0.85´14.3) = 184724mm2ccn cAc = 184724 = 430mmA = 3.6´(3.6 +1.5) = 18.36mm2N = nAq = 5´18.36´12 = 1101.6KNNc = 1.25CbN = 1.25´1.1´1.05´1101.6 = 1590.44KNA = N(U f ) = 1599.44´103 (0.85´14.3) = 131587mm2ccn cAc = 131587 = 362.75mm底层角柱
19、:A = 3.6´ 3.6 = 12.96mm2N = nAq = 5´12.96´12 = 777.6KNNc = 1.25CbN = 1.25´1.2´1.05´ 777.6 = 1224.72KNA = N(U f ) = 1224.72´103 (0.85´14.3) = 100758.5mm2ccn cAc = 100758.5 = 317.42mm因为各部分荷载比较均匀,且为使主体整体安全,故柱的截面600 ´ 600mm注:楼板厚度取 100mm,梁,板,柱均采用 C30 混凝土均选为1.2
20、.2.梁截面的确定(1)框梁截面高度一般按梁跨度的 1/101/12 估算,截面宽度可取梁高的1/21/3,且不小于柱高的一半,故:7200 跨度梁:h=(1/101/12) ´7200=(720mm600mm )取 h=600mmb=(1/31/2)´ 7200=(233mm350mm)取 b=3003000 跨度梁:h=(1/101/12) ´3000=(300mm250mm)b=(1/31/2) ´ 300=(100mm150mm)取 h=300mm取 b=150mm由于根据设计,最终 3000 跨梁截面取为 500mm´250mm(2)
21、次梁与框梁一致梁截面表 1.2.2注:楼板厚度取 120mm,梁,板,柱均采用 C30 混凝土1.2.3.计算简图的确定根据地质资料,取室内外高差为 1.2m,设基础至室外地坪 0.5m。框架结构简图如下,取顶层柱形心线作为框架柱的轴线。23 层柱高即为层高 3.6m,底层柱高度从基础顶面取到一层板底,即h1 =3.0+0.5=3.5m。框架计算简图如下:框架计算简图2.框架侧移刚度的计算2.1.框架横梁线刚度ib 的计算层次混凝土强度框梁与次梁(b ´ h)3000 跨梁(b ´ h)1 5C30300´ 600250´ 500梁的线刚度计算表 2.1
22、注:混凝土采用 C30,其弹性模量 Ec = 3´10 N / mm ;(计算梁线刚度时考虑,现浇楼板42的影响,边柱梁的惯性矩取 1.5 I0 ,中框架梁的惯性矩取 2 I0 , I0 为矩形截面梁的截面惯性矩)。2.2.框架柱侧移刚度计算框架柱侧移刚度计算表 2.2层次层高(m)柱号柱根数Kaic(104 KN × m )12h2(1/ m2 )Då D楼层 D(104 KN / m )54.11121.2850.39110.880.7143.03736.4589.27281.8580.4823.74429.95340.9640.3252.52510.1044
23、1.3940.4113.19312.77243.61121.1290.36112.40.9264.14549.74142.752121.6330.4495.15661.87340.8470.2983.42213.69441.2250.3804.36317.45部位断面b ´h(mm)矩形截面惯性1矩 I =bh3 012( ´ 10-3 m4 )跨度L(m)边跨梁中跨梁Ib = 1.5I0( ´ 10-3 m4 )i = EIb bL( ´ 10-3 m4 )Ib = 2I0( ´ 10-3 m4 )i = EIb bL( ´ 10-
24、3 m4 )屋架梁300 ´ 7008.67.212.95.3817.27.17楼层梁300 ´ 7008.67.212.95.3817.27.17走道梁300 ´ 4001.63.02.42.43.23.23.荷载计算3.1.恒荷载计算3.1.1.不上人屋面荷载标准值:0.02 ´ 25 = 0.5KN / m220mm 厚C30 粗砂粒料保护层0.05KN / m24mm 厚 SBS 改性沥青防水材料0.02 ´ 20 = 0.4KN / m220mm 厚 1:2.5 水泥砂浆找平层0.03´14 = 0.42KN / m230m
25、m 厚1:6 水泥焦渣找坡1.13 KN / m250mm 厚挤塑聚苯板0.02 ´ 20 = 0.4KN / m220mm 厚 1:3 水泥砂浆找平0.12 ´ 25 = 3KN / m2120mm 厚现浇钢筋混凝土屋板0.02 ´17 = 0.34KN / m220 厚板底抹灰:6.24 KN / m2小计:3.1.2.房间,走道,楼梯楼面的荷载标准值:0.01´0.65 = 0.0065KN / m210mm 厚水磨石面层0.02 ´ 20 = 0.4KN / m220mm 厚 1:4 干硬性水泥砂浆0.01´ 20 = 0.2
26、KN / m210mm 厚素水泥浆结合层一遍0.02 ´ 20 = 0.4KN / m220mm 厚 1:3 水泥砂浆找平层13.91121.2210.37911.440.7893.42141.05117.562121.7670.4694.23350.80340.9170.3142.83411.34441.3250.3983.59214.37-13.51121.0960.51612.750.986.44777.37214.572121.5860.5827.27287.27340.8230.4695.8623.44441.1900.5306.62226.490.12 ´ 25
27、 = 3KN / m2120mm 厚现浇钢筋混凝土楼板0.02 ´17 = 0.34KN / m220 厚板底抹灰:4.35 KN / m2小计:3.1.3.卫生间楼面荷载标准值:0.01´19.8 = 0.198KN / m210mm 厚防滑地砖铺实拍平,水泥擦缝0.025 ´ 20 = 0.5KN / m225mm 厚1:4 干硬水泥砂浆结合层0.015 ´ 20 = 0.3KN / m215mm 厚1:3 水泥砂浆找平0.06 ´ 25 = 1.5KN / m260mm 厚细石混凝土找坡0.12 ´ 25 = 3KN / m21
28、20mm 厚现浇钢筋混凝土楼板0.02 ´17 = 0.34KN / m220 厚板底抹灰:5.838KN / m2小计:3.1.4.间楼面荷载标准值:0.015 ´ 20 = 0.3KN / m215mm 厚1:2.2 水泥砂浆0.035´ 25 = 0.875KN / m235mm 厚C15 细石混凝土0.02 ´ 20 = 0.4KN / m220mm 厚 1:3 水泥砂浆找平0.12 ´ 25 = 3KN / m2120mm 厚钢筋混凝土楼板0.02 ´17 = 0.34KN / m220 厚板底抹灰:4.915KN / m2
29、小计:3.1.5室楼面荷载标准值:0.02 ´ 20 = 0.4KN / m220mm 厚 1:2.5 水泥砂浆抹面压光0.06 ´ 25 = 1.5KN / m260mm 厚 C15 细石混凝土防水层向排水沟找坡0.08´ 25 = 2KN / m280mm 厚 C15 混凝土垫层0.12 ´ 25 = 3KN / m2120mm 厚钢筋混凝土底板0.02 ´17 = 0.34KN / m220 厚板底抹灰:7.24 KN / m2小计:3.1.6 水泥砂浆顶棚表面喷刷涂料荷载标准值(室)0.005´ 20 = 0.1KN / m2
30、5mm 厚EC 聚合物砂浆保护层,内置玻纤网络布黏贴 20mm 厚岩棉板,专业粘结0.02 ´1.5 = 0.03 KN / m2刷素水泥浆一遍0.13KN / m2小计:3.1.7.轻钢龙骨纸面石膏板吊顶(门厅、走道) 表面装饰配套防潮涂料一遍9mm 厚 900*2700 纸面石膏板0.01´14 = 0.14KN / m2轻钢龙骨标准骨3.1.8.铝合金方板吸音吊顶(卫生间)1 厚铝合金穿孔方板铝合金横撑铝合金中龙骨大龙骨龙骨档内填 50 厚岩棉吸音,用直径为 8mm 螺栓吊杆,双向吊顶丝布包好0.05´1.5 = 0.075KN / m2钢筋混凝土板内预留直
31、径为 6mm 铁环双向吊点3.1.9 其它吊顶刷乳胶漆5 厚 1:0.3:2.5 水泥石灰膏砂浆抹面5 厚 1:0.3:3 水泥石灰膏砂浆打底扫毛刷素水泥浆一道0.015´ 20 = 0.3KN / m2钢筋混凝土楼板底3.2.活载计算0.5KN / m2不上人屋面均布活荷载:2.0KN / m2办公室楼面均布活荷载:250KN间楼面活荷载:8KN / m2卫生间楼面均布活荷载(带蹲坑):3.5KN / m2楼梯间,走道,门厅楼面均布活荷载:0.3KN / m2屋面雪荷载标准值:5KN / m2储藏室均布荷载标准值:3.3.墙体重力荷载标准值的计算-1 4层外墙墙厚300mm,采用瓷
32、砖贴面;内墙墙厚200mm,采用水泥砂浆抹面,内外墙均采用加气混凝土砌块砌筑。室外墙墙厚360mm,内墙墙厚240mm,外墙采用钢筋混凝土,内墙采用空心混凝土砌块砌筑,采用水泥砂浆抹面。1 5层面积外墙体重量为:5.5×0.3=1.65KN/m 21 5层面积内墙体重量为:5.5×0.2=1.10 KN/m 2m2室室面积外墙体重量为:25×0.36=9 KN/m2面积内墙体重量为:11.8×0.24=2.832kN/门窗重力荷载标准值的计算0.45KN / m2(1)塑钢窗:0.45KN / m2(2)塑钢全玻门:0.2KN / m2平开镶板门:0.9
33、KN / m2防火门:3.5.各层重力荷载代表值的计算该纵向总厂为 50.9m。根据混凝土结构设计规范(GB50010-2002)的规定可不设置伸缩缝。梁柱布置图如下图所示:梁柱布置图3.5.1.柱各层柱的重力荷载代表值:各层重力荷载代表值的计算表 3.5.1.13.5.2.梁各层梁的重力荷载代表值:各层梁的重力荷载代表值的计算层次计算高度(m)b(m)h(m)V( m3 )单重(KN)数量总重(KN)54.10.650.651.73243.3281212.4243.60.650.651.51237.8321209.613.90.650.651.64841.2321318.4-13.50.65
34、0.651.47936.98321183.4表 3.5.23.5.3.墙体墙体的重力荷载代表值的计算:层次构件计算高度(m)计算长度(m)门窗面积(m²)面积(m²)容重(KN/)总重(KN)合计(KN)5外纵墙3.5240.9(×2)77.04210.8961.65347.9784934.6799内纵墙3.526.7(×6.5)14.4138.8961.1152.7856外横墙(屋)3.526.7(×4)094.3361.65155.6544外横墙(廊)3.522.5(×2)5.8511.751.6519.3875内横墙(屋)3.5
35、26.7(×8)5.7182.9721.1201.2692内横墙(廊)3.522.53.65.21.15.72卫生间内横墙3.526.7(×2)047.1681.151.884824外纵墙3.0248.9(×2)100.668194,6881.65321.23521084.9641内纵墙3.026.7(×13)39.6223.4421.1245.7862层次类别净跨(m)b/mh/mV/ m3单重(KN)数量总重(KN)合计(KN)- 15长跨横梁7.2-0.55=6.650.30.71.39734.92512419.11555.05(×5)走
36、道横梁3-0.55=2.450.30.40.2947.35214.77.2m 跨纵梁7.2-0.55=6.650.30.71.39734.92524838.23.6m 跨纵梁3.6-0.55=3.050.30.70.64116.025232.05次梁7.2-0.55=6.650.30.71.39734.9256209.55室梯段梁3.20.30.50.4812112双合式梯段梁7.2-0.55=6.650.30.50.99824.95124.95单跑梯段梁1.20.30.50.184.514.53.5.4.门窗各层门窗重力荷载代表值层次门窗合计(KN)外横墙(楼)3.026.7(*4)080.
37、9361.65133.5444外横墙(廊)3.022.5(*2)5.859.251.6515.2625内横墙(楼)3.026.7(*15)8.4295.111.1324.621卫生间内横墙3.026.7(*2)040.4681.144.51481外纵墙3.3248.9(×2)136.84187.8561.65309.9624976.1813内纵墙3.326.7(×8.5)31.5152.44851.1167.6934外横墙(楼)3.326.7(×4)088.9761.65146.8104外横墙(廊)3.322.5(×2)5.8510.751.6517.7
38、375内横墙(楼)3.326.7(×11)7.8236.8841.1260.5724卫生间外横墙3.326.7(×2)044.4881.6573.4052-1外纵墙2.9248.9(×2)14.4271.1761.65447.4404971.7433内纵墙2.926.7(*12)48.3186.4681.1205.1148外横墙(楼)2.926.7(*4)078.2561.65129.1224外横墙(廊)2.922.5(*2)3.7510.851.6517.9025内横墙(楼)2.926.7(*8)0156.5121.1172.1632表 3.5.43.5.5.楼
39、板标号高(m)宽(m)数量容重(KN/)总重(KN)标号高( m)宽(m)数量容重(KN/)总重(KN)25M10212.11160.26.72C12121.21.2120.457.776158.607M10242.41270.212.96C062020.680.454.32M15242.41.5100.27.2C27232.32.7120.4533.534M08212.10.860.22.016C15181.81.5110.4513.365FM 乙15212.11.530.98.505C18181.81.8340.4549.575C06262.60,6180.4512.6361M10242.
40、4170.23.36C12121.21.240.452.59263.765M10212.1190.23.78C06202.60.640.452.808FM 乙15212.11.530.98.505C27232.32.760.4516.767C12151.51.210.450.81M15242.41.510.20.72C24151.52.410.451.62M08212.10.820.20.672C15181.81.530.453.645M18212.11.820.453.402C18181.81.8100.4514.58M12212.11.210.20.504-1M15212.11.5100.
41、26.3GC12120.41.8200.456.4836.675FM 甲15212.11.550.914.175GC15180.41.510.450.27FM 乙15212.11.520.95.67FM 甲10212.1120.93.78各层楼板的重力荷载代表值的计算表 3.5.53.5.6.恒载总汇各层恒荷载汇总表表 3.5.63.5.7.活荷载的计算5 层屋面:(21.6´18.9 + 7.2´7.2´6 + 3´7.2´ 4)´0.5 + 7.2´7.2´3.5 + 250 = 834.28KN5 层楼面:(
42、7.2´3´18.9 + 7.2´7.2´6 + 7.2´3´ 4)´ 2 + 7.2´7.2´3.5 + 7.2´7.2´8 = 2207.52KN4 层楼面(7.2´7.2´12)´ 2.0 + 7.2´7.2´8 + 7.2´7.2´3.5 + 3´7.2´7´3.5 = 2369.52KN3 层楼面(7.2´7.2´12)´ 2.0 + 7.2
43、80;7.2´8 + 7.2´7.2´3.5 + 3´7.2´7´3.5 = 2369.52KN层次梁(KN)板(KN)小计(KN)柱(KN)墙(KN)门窗(KN)小计(KN)51555.054081.28895636.3391212.4934.679960.1382207.241555.054083.07245638.1221209.61084.964156.5472351.131555.054083.07245638.1221209.61084.964156.5472351.121555.054083.07245638.12212
44、09.61084.964155.3922349.911555.054083.07245638.1221318.4976.181363.7652358.3-11555.054005.43655560.4871183.4971.743336.6752191.8层次面积( m2 )梁面积( m2 )柱面积( m2 )卫生间( m2 )楼梯间( m2 )总重(KN)5736.0972.848.4751.5951.594081.288914713.6994.449.6851.5951.594083.0724-1765.1894.449.68051.494005.43652 层楼面: (7.2´
45、7.2´12)´ 2.0 + 7.2´7.2´8 + 7.2´7.2´3.5 + 3´7.2´7´3.5 = 2369.52KN1 层楼面:7.2´7.2´9´ 2.0 + 7.2´7.2´8 + 7.2´7.2´3.5´ 2 + 7.2´7.2´ 2.5´ 2 + 3´7.2´7´3.5 = 2499.12KN-1 层楼面: 7.2´7.2´10
46、´5 + 7.2´7.2´ 2 + 7.2´7.2´3.5´ 2 + 7.2´3´7´3.5 = 3587.76KN3.5.8.计算各层重力荷载代表值顶层重力荷载代表值包括:屋面恒荷载,50%屋面雪荷载,梁板自重,半层柱自重,半层墙重。一般层重力荷载代表值包括:楼面恒荷载,50%楼面活荷载,梁板自重,半楼面上下各半层柱及墙体自重。G5 = 5636.339 + 0.5 ´ 2207.2 + 0.5 ´ 834.28 = 6957.1KN G4 = 5636.339 + 0.5 ´ 2207.2 + 0.5 ´ 834.28 = 7157.1KN G3 = 5638.122 + 0.5 ´ 2351.1 + 0.5 ´ 2207.52 = 7917.4KN G2 = 5638.122 + 0.5 ´ 2349.9 + 0.5 ´ 2369.52 = 7997.8KN G1 = 5638.122 + 0.5 ´ 2358.3 + 0.5 ´ 2499.12 = 8066.8KN= 5560.487 + 0.5 ´ 2191.8 + 0.5 ´ 358
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 水生动物检疫防疫员测试验证强化考核试卷含答案
- 复合材质文物修复师创新方法评优考核试卷含答案
- 三年级数学周长知识点专项测试题
- 高一期末英语非谓语专项训练
- 小学数学半期测试题目集锦
- 医院物资采购与库存管理流程
- 公司年度营销推广活动总结报告
- 科学三年级上册综合知识期末测试卷
- 生产过程监控系统创新创业项目商业计划书
- 精密数控机床校准服务行业跨境出海项目商业计划书
- 【《基于Java Web的网络题库和考试系统设计与实现》8900字(论文)】
- 学堂在线 实验室安全教育 章节测试答案
- 医院应急知识培训课件
- 2025-2030中国抗骨质疏松药物市场调研及未来增长预测报告
- 2025年注册道路工程师执业资格基础考试应试辅导(公共基础)(上下册)
- 终极焊工考试试题及答案
- 国家能源安庆市2025秋招能源与动力工程类面试追问及参考回答
- 房屋安全性鉴定培训试题及答案解析
- 2025广西南宁上林县公安局面向社会招聘警务辅助人员50人笔试备考试题及答案解析
- 2025年知识产权普法知识竞赛题库附答案
- 黑龙江省齐齐哈尔市富拉尔基区2024-2025学年高一上学期期中考试生物试题含参考答案
评论
0/150
提交评论