1、光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S36风机温度 0 光缆盘号001光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号A3接头塔号A3纤芯衰减测试测试线路长度0. 844km方向升压站至S36风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3218W0.350.312OR0.350.3219R0.350.303G0.350.3120N0.350.314BR0.350.3021Y0.350
2、.325GR0.350.3122V0.350.316W0.350.3223P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.302610V0.350.312711P0.350.322812AQ0.350.312913B0.350.303014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3034测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂
3、家 测试日期2018年01月20日测试地点S24风机温度 0 光缆盘号001光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号A18接头塔号A18纤芯衰减测试测试线路长度 0.524 km方向S24至S25风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3218W0.350.312OR0.350.3219R0.350.303G0.350.3120N0.350.314BR0.350.3021Y0.350.315GR0.350.
4、3122V0.350.316W0.350.3223P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.302610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年0
5、1月20日测试地点S25风机温度 0 光缆盘号001光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号A17接头塔号A17纤芯衰减测试测试线路长度1.125 km方向S25至S26风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3018W0.350.302OR0.350.3119R0.350.313G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.32
6、6W0.350.3123P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.302610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S26风
7、机温度 0 光缆盘号001光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号A15接头塔号A15纤芯衰减测试测试线路长度1.102 km方向S26至S29风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3018W0.350.302OR0.350.3119R0.350.313G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P
8、0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.302610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S27风机温度 0 光缆盘号004
9、光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号AB4接头塔号AB4纤芯衰减测试测试线路长度0.648 km方向S27至S28风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3018W0.350.302OR0.350.3119R0.350.313G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.3
10、50.3124AQ0.350.318N0.350.31259Y0.350.302610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S28风机温度 0 光缆盘号004光纤芯数24测试波长131
11、0 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号AB6接头塔号AB6纤芯衰减测试测试线路长度1.242 km方向S28至S25风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3018W0.350.302OR0.350.3119R0.350.313G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.350.3124AQ0.35
12、0.318N0.350.31259Y0.350.302610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S29风机温度 0 光缆盘号002光纤芯数24测试波长1310 nm测试项目开盘测试标
13、称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号AB6接头塔号AB6纤芯衰减测试测试线路长度 0.675 km方向S29至S26风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3018W0.350.302OR0.350.3119R0.350.313G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.350.3124AQ0.350.318N0.350.
14、31259Y0.350.302610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S30风机温度 0 光缆盘号002光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损
15、伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号A11接头塔号A11纤芯衰减测试测试线路长度 0.685 km方向S29至S30风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3018W0.350.302OR0.350.3119R0.350.313G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.
16、302610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S31风机温度 0 光缆盘号001光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度
17、4200 m线盘质量完好无损坏接头衰减测试接头桩号A9接头塔号A9纤芯衰减测试测试线路长度0.665 km方向S30至S31风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3018W0.350.302OR0.350.3119R0.350.313G0.350.3120N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.302610V0.350.31
18、2711P0.350.312812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S38风机温度 0 光缆盘号002光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏
19、接头衰减测试接头桩号AA6接头塔号AA6纤芯衰减测试测试线路长度 2.234 km方向S38至S36风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3118W0.350.302OR0.350.3119R0.350.313G0.350.3120N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.302610V0.350.312711P0.350.3
20、22812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S39风机温度 0 光缆盘号001光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号AA
21、8接头塔号AA8纤芯衰减测试测试线路长度 0.952 km方向S38至S39风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3118W0.350.312OR0.350.3119R0.350.313G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.312610V0.350.312711P0.350.322812AQ0.350
22、.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S40风机温度 0 光缆盘号002光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号B11接头塔号B11纤芯衰减
23、测试测试线路长度 1.436 km方向S40至S44风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3218W0.350.322OR0.350.3119R0.350.313G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.327R0.350.3124AQ0.350.318N0.350.31259Y0.350.302610V0.350.312711P0.350.322812AQ0.350.312913B0.35
24、0.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S41风机温度 0 光缆盘号002光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号B12接头塔号B12纤芯衰减测试测试线路长度 0.4
25、52 km方向S40至S41风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3218W0.350.322OR0.350.3119R0.350.323G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.312610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.
26、350.313115G0.350.323216BR0.350.313317GR0.350.3234测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S44风机温度 0 光缆盘号003光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号BAA4接头塔号BAA4纤芯衰减测试测试线路长度 0.432 km方向S45
27、至S44风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3118W0.350.312OR0.350.3119R0.350.313G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.312610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115
28、G0.350.323216BR0.350.313317GR0.350.3034测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S45风机温度 0 光缆盘号002光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号BAA2接头塔号BAA2纤芯衰减测试测试线路长度 0.874 km方向S45至S29风机纤芯序号
29、纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3218W0.350.312OR0.350.3119R0.350.313G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.302610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S46风机温度 0 光缆盘号003光纤芯数24测试波长1310
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 基于用户隐私的版本控制可视化方案-洞察及研究
- 社区亲子活动推广方案策划
- 美妆穿搭活动策划方案
- 人工智能在农业供应链优化中的角色-洞察及研究
- 智能材料的自愈合机制研究-洞察及研究
- 施工方案最后要归档吗
- 带式输送安全培训考试题及答案解析
- 外墙水泥水管施工方案
- 宁德工业安全考试题库及答案解析
- 锅炉管道安全管理题库及答案解析
- 中医课题申报书的范文怎么写
- 2025年公基常识题及答案
- 诺如病毒胃肠炎诊疗方案(2025年版)解读学习课件
- 2025年地方AMC行业研究报告及未来行业发展趋势预测
- 农业综合行政执法大比武试题库(试题及答案)
- 2025年零碳园区发展白皮书-荣续ESG智库
- 国企新员工入职纪检培训
- 2024全国职业院校技能大赛ZZ060母婴照护赛项规程+赛题
- 特殊天气驾驶安全规范
- 新闻文体的翻译课件
- 西方翻译理论流派划分探索
评论
0/150
提交评论