1、TESTPROGRAMONBOARDOFELECTRICPOWERSYSTEM0.General0.1AttendantsThetestshallbeconductedincompliancewiththeprogramandwitnessedbypresentedofthesurveyorofclassificationsocietyandtheownerrepresentative,unlessotherwisementioned.0.2TestingconditionDuringtesting,alltheelectricequipmentshallbekeptitsservicecon
2、ditionasnearaspracticable,andgaugesfixedontheinstrumentboardofequipmentshallgenerallybeusedforcheckingandtakingarecord.Eachtestshallbecarriedoutwhenthevesselismooredalongsidethebuilderswharf,unlessotherwisementioned.TESTPROGRAMElectricPowerSystemMaindieselgeneratorsandEmergencygeneratorGeneralDuring
3、testonboard,inprinciplewaterresistanceshallbeusedastestload(PF=1.0)exceptatseatrialorotherwisenoted.InsulationresistancetestBeforeandafterthegeneratorheatrunningtest,insulationresistancebetweenthefollowingpointsshallbemeasuredbyuseofaDC500VMeggeranditshallbeconfirmedthattheresistanceis1mega-ohmorabo
4、ve:-Winding-shipshull-Spaceheater-shipshullTheresultsofabovetestarerecordedinattachedsheets1E2,3,4onpages15,16,17,18.Heatruntest(Continuousloadtest)Increasegeneratorloadgraduallyfromzerotofullandthenrunthegeneratorcontinuouslyfor60minutesunderfullloadcondition,15minutesunder110%fullloadatlast.Measur
5、ethefollowingparametersandrecordthedataduringthistest.Output(kW),Frequency(Hz),Voltage(V),Current(A),Temperature。)ofAir,Frame,Stator,BearingandEngineroom.Itshallbeconfirmedthatthegeneratorisfreefromanabnormalriseoftemperatureateachpart.Thetemperatureshallbemeasuredbyusingofthermometermethod.Themeasu
6、rementpointsandresultsofmeasurementarerecordedinattachedsheetsE-5,6,7,8,onpages19,20,21,22.Voltagecharacteristictest(Loadcharacteristictest)Atafullratedload,thevoltageandfrequencyshallbesettoaratedpointandmeasurementshallbetakenonthevoltageandfrequencyateachpointwiththeloadchangedasfollows:100%-75%-
7、50%-25%-0-25%-50%-75%-100%Duringtheabovemeasurement,itshallbeconfirmedthatavoltagevariationateachpointiswithin2.5%(11.3V)forMaingenerator,3.5%(15.8V)forEmcygeneratorTheresultsofthemeasurementarerecordedinattachedsheetsE-9,10,11,12onpages23,24,25,26.Speedvariationtest(Voltageregulatingandgovernortest
8、)Thisshallmeasurethemomentaryvariationandthepermanentvariationofvoltageandfrequencywhenthefollowingloadissuddenlytakenofforon:Maingen.:Takenoff100%-0Takenon0-45%-80%-100%EMcygen.:Takenoff100%-0Takenon0-75%-100%Itshallbeconfirmedthattheregulationiswithinthefollowings:Instantaneousfrequency:10%(土6Hz)S
9、ettledfrequency:5%(土3Hz)(stabilizedtime5s)Instantaneousvoltage:-15%+20%(-67.5V+90V)Settledvoltage:Maingen:2.5%(11.3V)Emicygen:3.5%(土15.8V)TheresultsoftheabovetestarerecordedinattachedsheetsE-13,14,15,16onpages27,28,29,30.Parallelrunningtest(Maingeneratorsonly)-Aftertwogeneratorsaremanuallyoperatedin
10、parallel,firstregulatetheloadforeachgeneratorto75%ratedasinitialpointofparalleling,thentheloadofprovisionalbasegeneratorischangedas:75%-50%-25%-50%-75%-100%-75%Ineachpointoftheaboveloads,theeffectivepower,voltageandfrequencyshallbemeasuredandtheloadsharingistobesuchthattheactiveloadonanygeneratorisn
11、ottodifferfromitsproportionateshareofthetotalloadbymorethan15%.Themaximumvalueis600kWx15%=90kW.Theloadsharingtestshallbecarriedoutbetweenanytwo(2)generatorsetsofthree(3),itscombinedgroupswillbeNo.-No.2Gen-sets,No.-No.3Gen-setsandNo.-No.1”Gen-sets.TheresultsofabovetestarerecordedinattachedsheetsE-17,
12、18,19onpages31,32,33.Loadtransfertest(maingensetsonly)Suchtestshouldbecarriedoutundertheconditionofregulatingtheloadofeachgeneratorto50%ratedoutputapproximately,totallyhavingthree(3)combinedgroupsandtestingsequenceasfollowing:No.1&No.2Gen-setsinparallelrunningManuallysynchronizingoperatingtheNo.3Gen
13、-set,thenmakingtheNo.1Gen-setoutofservice.No.2&No.3Gen-setsinparallelrunningManuallysynchronizingoperatingtheNo.1Gen-set,thenmakingtheNo.2Gen-setoutofservice.No.3&No.1Gen-setsinparallelrunningManuallysynchronizingoperatingtheNo.2Gen-set,thenmakingtheNo.3Gen-setoutofservice.Theresultsofabovearerecord
14、edinattachedsheetE-20onpage34.GeneratorprotectingdeviceForthefollowinggeneratorprotectingdevices,onlythedemonstrationcarriedout,becausedeviceshavebeenexactlyadjustedatmanufacturersworkingshop.Settingmarksaretobeconfirmed.Reversepowerprotection(maingensetsonly)Eachmaingeneratorshallbegivenareversepow
15、erprotectionasmentionedbelowanditshallbeconfirmedthatthereversepowerrelay(orequaldevice)startstoworkproperlyandtheaircircuitbreakeropensatasettime.Settingofreversepower:-10%ofrating(60kW)Delaytime102secThisdemonstrationshallbeconductedonceandtimefromreversepowersupplytobreakeropeningshallbemeasuredf
16、orreference.TheresultsoftheabovetestarerecordedinattachedsheetE-21onpage35.Over-currentprotectionThisdemonstrationshallbecarriedoutintheconditionthatnoloadisappliedontheprimemover.Theover-currentrelay(orequaldevice)ateachphaseofthegeneratorshallbefedwithcurrentsasmentionedbelowanditshallbeconfirmedt
17、hattherelay(orequaldevice)startstoworkproperlyandtheaircircuitbreakeropensatasettingtime.Settingvalue:Maingen:962Ax110%x120%=1270ADelaytime203secEMcygen:192x110%x120%=253ADelaytime203secThisdemonstrationshallbeconductedonceandtimefromover-currentsupplytobreakeropeningshallbemeasuredforreference.Ther
18、esultsoftheabovetestarerecordedinattachedsheetE-22onpage35.Preferentialtriptest(MSBonly)Thisdemonstrationshallbecarriedoutintheconditionthatnoloadisappliedontheprimemover.Theover-currentrelay(orequaldevice)forpreferentialtripforeachmaingeneratorshallbefedwithcurrentsasmentionedbelowanditshallbeconfi
19、rmedthatrelay(orequaldevice)startstoworkproperlyandtheover-currentrelay(orequaldevice)closesinasettimetoletthe1stand2ndstepnonessentialconsumersbreakerstripbyshunttripdevices.Itshallbeconfirmedthatthealarmlampsforpreferentialtripareliton.Settingofcurrent:For1stStep:962x120%=1152ADelaytime102sFor2ndS
20、tep:963x120%=1152ADelaytime15+2sThisdemonstrationshallbecarriedoutonceandtimefromovercurrentsupplytorelevantbreakerstrippingshallbemeasuredforreference.TheresultsoftheabovetestarerecordedinattachedsheetE-23onpages36,37.UndervoltagetriptestTheACB(aircircuitbreaker)shalltripwhenbusbarvoltagedropto180V
21、300VTheresultsoftheabovearerecordedinattachedsheetE-24onpage38.InterlockingtestofshoreconnectionInterlockingtestofshoreconnectionistoconfirmthereliabilityofinterlockingcircuitbetweenMCCBofshoreconnectionandACBofeachgenerator.Thatis,theshorepowercircuitbreakerontheMSBcannotbeswitchedonifanyoneACBofth
22、ree(3)generatorsisinclosepositionorviceversa,anyoneACBofthree(3)generatorscannotbeswitchedoniftheshorepowercircuitbreakerontheMSBisincloseposition.TheresultsoftheabovetestarerecordedinattachedsheetE-25onpage38.AutostarttestforemcygeneratorandinterlockingtestbetweenMSBandESBThistestshallconfirmtherel
23、iabilityofthefollowingfunctions:Simulateaconditionofblack-outonbusbar,thetiebreakerbetweenMSBandESBwillundervoltagetrip,theemergencygeneratorwillbestartedautomaticallyandsupplypowertoESBwithin45seconds.Afterrecoveryofpowersupplyonbusbar,atfirsttheACBofemcygeneratortobetripped,thenthebustiebreakerbet
24、weenMSBandESBtobeclosed,andtheemeratortobygenstoppedafteradelaytime.Theprocessisalsotobeautomatic.TheresultsoftheabovetestarerecordedinattachedsheetE-26onpage38.PowermanagementsystemThetestmentionedbelowshallbecarriedoutinautomodefortherelativegenerators.Autostarttestofstandbygeneratorafterblack-out
25、Incaseofblack-out,thestandbydieselgeneratorsetshouldbestartedimmediatelyandconnectedtothenetworkautomatically.Thetestshallbecarriedoutaccordingtothefollowingprocedure:No.AutostartstandbyD/Gafterblack-out1RunNo.1D/GonthebusbarSelectNo.2D/GasfirstprioritystandbysetSimulateNo.1D/Gshutdownsignal,thenNo.
26、1D/Gshouldbetrippedimmediatelyandblack-outonthebusbarNo.2D/Gshouldbeautomaticallystartedandconnectedtothebusbarafterestablisheditsvoltageandrecoverpowersupply2RunNo.2D/GonthebusbarSelectNo.3D/GasfirstprioritystandbysetSimulateNo.2D/Gshutdownsignal,thenNo.2D/Gshouldbetrippedimmediatelyandblack-outont
27、hebusbarNo.3D/Gshouldbeautomaticallystartedandconnectedtothebusbarafterestablisheditsvoltageandrecoverpowersupply3RunNo.3D/GonthebusbarSelectNo.1D/GasfirstprioritystandbysetSimulateNo.3D/Gshutdownsignal,thenNo.3D/Gshouldbetrippedimmediatelyandblack-outonthebusbarNo.1D/Gshouldbeautomaticallystartedan
28、dconnectedtothebusbarafterestablisheditsvoltageandrecoverpowersupplyTheresultsoftheabovetestarerecordedinattachedsheetE-27onpage39.StandbygeneratorscontinuousstarttestSelectthreegeneratorsinAutomodelRunoneD/Gsetonthebusbar,selectanothertwoD/GsetsaspriorityofNo.1andNo.2standby.Disconnectthewireconnec
29、tionofstartreadysignaloftheD/GsetwithNo.1prioritytopowermanagementsystem.SimulateshutdownsignaloftherunningD/Gset,thentheD/GsetwithNo.1prioritynotbeabletostart,andtheD/GsetwithNo.2prioritywillbeautomaticallystart.TheabovementionedfunctionsshallbeconfirmedandthetestresultsarerecordedinattachedsheetE-
30、28onpage39.AutostarttestofstandbygeneratorincaseofvoltageorfrequencyabnormalSelectthreegeneratorsinAutomodeIncaseofthefollowingconditionsoccurred:Lowvoltage:95%oftheratedvoltage,delay5secHighvoltage:105%oftheratedvoltage,delay5secLowfrequency:95%oftheratedfrequency,delay5sec,thestandbygeneratorshoul
31、dbeautomaticallystartedinadelaytimeandthefaultgeneratoronlinewillbeautomaticallydisconnectedformbusbar,thentheACBofstandbygeneratorshouldbeclosedautomatically.No.Thetestshallbecarriedoutaccordingtothefollowingprocedure.AutostartstandbyD/GincaseofvoltageorfrequencyabnormalSelectNo.2D/Gsetasthefirstpr
32、ioritystandbysetRunNo.1D/GsetonthebusbarReducethevoltageofNo.1D/Gto428VNo.2D/GsetwillbeautomaticallystartedandreadytoconnectedtothebusbaraftersecondsdelayNo.1D/Gsetwillbeautomaticallydisconnectedfromthebusbar,shortblack-outNo.2D/Gsetwillbeautomaticallyconnectedtothebusbar,recoverpowersupplySelectNo.
33、3D/GsetasthefirstprioritystandbysetRunNo.2D/GsetonthebusbarReducethevoltageofNo.2D/Gto428VNo.3D/GsetwillbeautomaticallystartedandreadytoconnectedtothebusbaraftersecondsdelayNo.2D/Gsetwillbeautomaticallydisconnectedfromthebusbar,shortblack-outNo.3D/Gsetwillbeautomaticallyconnectedtothebusbar,recoverp
34、owersupplySelectNo.1D/GsetasthefirstprioritystandbysetRunNo.3D/GsetonthebusbarReducethevoltageofNo.3D/Gto428VNo.1D/GsetwillbeautomaticallystartedandreadytoconnectedtothebusbaraftersecondsdelayNo.3D/Gsetwillbeautomaticallydisconnectedfromthebusbar,shortblack-outNo.1D/Gsetwillbeautomaticallyconnectedt
35、othebusbar,recoverpowersupplySelectNo.2D/GsetasthefirstprioritystandbysetRunNo.1D/GsetonthebusbarIncreasethevoltageofNo.1D/Gto473VNo.2D/GsetwillbeautomaticallystartedandreadytoconnectedtothebusbaraftersecondsdelayNo.1D/Gsetwillbeautomaticallydisconnectedfromthebusbar,shortblack-outNo.2D/Gsetwillbeau
36、tomaticallyconnectedtothebusbar,recoverpowersupplySelectNo.3D/GsetasthefirstprioritystandbysetRunNo.2D/Gsetonthebusbar-IncreasethevoltageofNo.2D/Gto473V-No.3D/GsetwillbeautomaticallystartedandreadytoconnectedtothebusbaraftersecondsdelayNo.2D/Gsetwillbeautomaticallydisconnectedfromthebusbar,shortblac
37、k-outNo.3D/Gsetwillbeautomaticallyconnectedtothebusbar,recoverpowersupplySelectNo.1D/GsetasthefirstprioritystandbysetRunNo.3D/GsetonthebusbarIncreasethevoltageofNo.3D/Gto473V-No.1D/GsetwillbeautomaticallystartedandreadytoconnectedtothebusbaraftersecondsdelayNo.3D/Gsetwillbeautomaticallydisconnectedf
38、romthebusbar,shortblack-outNo.1D/Gsetwillbeautomaticallyconnectedtothebusbar,recoverpowersupplySelectNo.2D/GsetasthefirstprioritystandbysetRunNo.1D/GsetonthebusbarReducethefrequencyofNo.1D/Gto57HzNo.2D/GsetwillbeautomaticallystartedandreadytoconnectedtothebusbaraftersecondsdelayNo.1D/Gsetwillbeautom
39、aticallydisconnectedfromthebusbar,shortblack-outNo.2D/Gsetwillbeautomaticallyconnectedtothebusbar,recoverpowersupplySelectNo.3D/GsetasthefirstprioritystandbysetRunNo.2D/GsetonthebusbarReducethefrequencyofNo.2D/Gto57HzNo.3D/Gsetwillbeautomaticallystartedandreadytoconnectedtothebusbaraftersecondsdelay
40、No.2D/Gsetwillbeautomaticallydisconnectedfromthebusbar,shortblack-outbus bar, recoverNo.3D/Gsetwill9SelectNo.1D/GsetasthefirstprioritystandbysetRunNo.3D/GsetonthebusbarReducethefrequencyofNo.3D/Gto57HzNo.1D/GsetwillbeautomaticallystartedandreadytoconnectedtothebusbaraftersecondsdelayNo.3D/Gsetwillbe
41、automaticallydisconnectedfromthebusbar,shortblack-outNo.1D/Gsetwillbeautomaticallyconnectedtothebusbar,recoverpowersupplyTheresultsoftheabovetestarerecordedinattachedsheetE-29onpage39.D/Gsetautostart/stoptestbasedonactivepowerconsumptionIncaseofonegeneratorisrunningonbusbarandtheactivepowerconsumpti
42、onisover90%ratedoutput(540Kw),thestandbyD/Gsetwillbeautomaticallystartedafter5seconds,synchronizedandconnectedtomainbustoruninparallelwithanotherD/Gsetwhichisalreadyrunningonbusbar,andthenloadsofgeneratorsshallbeautomaticallyshared.IncaseoftwoD/Gsetsarerunningonthebusbarandtheactivepowerconsumptioni
43、sbelow30%oftheirratedoutput(360kW)for10minutes,thestandbyD/Gsetonbusbarwillbeautomaticallydisconnectedfrombusbarafterloadshifting,thenthestandbyD/Gwillbeautomaticallystoppedafter1minute.Thetestshallbecarriedoutaccordingtofollowingprocedures:No.Autostart/stopstandbyD/Gandloadsharing1SelectNo.2D/Gseta
44、sthefirstprioritystandbysetRunNo.1D/GsetonthebusbarIncreaseloadconsumptionto540Kw.No.2D/Gsetwillbeautomaticallystarted,synchronizedandrunninginparallelwithNo.1D/G.Loadswillbeautomaticallysharedandeachofgeneratorswillshareabout270KwloadContinuingincreaseloadconsumptionto900Kw,loadsharingwillbecarried
45、outbetweenNo.1andNo.2D/GsetautomaticallyReducethetotalpowerconsumptionto360Kw,No.2D/Gsetwillbeautomaticallydisconnectedfromthebusbar,andstoppedafter10minutesautomatically.2SelectNo.3D/GsetasthefirstprioritystandbysetRunNo.2D/GsetonthebusbarIncreaseloadconsumptionto540Kw.No.3D/Gsetwillbeautomatically
46、started,synchronizedandrunninginparallelwithNo.2D/G.Loadswillbeautomaticallysharedandeachofgeneratorswillshareabout270KwloadContinuingincreaseloadconsumptionto900Kw,loadsharingwillbecarriedoutbetweenNo.2andNo.3D/GsetautomaticallyReducethetotalpowerconsumptionto360Kw,No.3D/Gsetwillbeautomaticallydisc
47、onnectedfromthebusbar,andstoppedafter10minutesautomatically.3SelectNo.1D/GsetasthefirstprioritystandbysetRunNo.3D/GsetonthebusbarIncreaseloadconsumptionto540Kw.No.1D/Gsetwillbeautomaticallystarted,synchronizedandrunninginparallelwithNo.3D/G.Loadswillbeautomaticallysharedandeachofgeneratorswillsharea
48、bout270KwloadContinuingincreaseloadconsumptionto900Kw,loadsharingwillbecarriedoutbetweenNo.3andNo.1D/GsetautomaticallyReducethetotalpowerconsumptionto360Kw,No.1D/Gsetwillbeautomaticallydisconnectedfromthebusbar,andstoppedafter10minuteautomatically.TheresultsoftheabovetestarerecordedinattachedsheetE-
49、30onpage40.LoaddemandfunctiontestIfoneoflargepumpmotorslistedhereunderisrequestedtobestartbypressthestartpushbutton,thepowermanagementsystemwillcalculatetheactivepoweronthebusbarandpreparesufficientactivepowertoallowthemotorcanbestarted.No.Largepumpmotors1No.1ballastpumpmotor2No.2ballastpumpmotor3C.
50、O.P.T.COND.C.W.pumpmotorTheresultsoftheabovetestarerecordedinattachedsheetE-31onpage40.EmergencygeneratorautomaticcontrolsystemtestTestresultsaretoberecordedinsheetE-32onpage40.AlarmpointinspectionSeveralalarmlampslistedhereunderarelocallypresentedonthecontrolpanel,checkthesealarmsonebyone.No.Alarms
51、1Coolingwaterhightemperature2Coolingwaterlowpressure3L.O.pressurelow4L.O.temperaturehigh5FuelpipleakageOverspeedprotectionEmergencygeneratorshouldbeshutdownincaseofoverspeed.Thistestshouldbecarriedoutinaccordancewiththetestproceduressubmittedfrommachinerypart.Black-outtestItshallbeconfirmedthatunder
52、theconditionofblack-outonMSBbusbar,theemcygen.setshouldbestarted,thensupplytheelectricalpowersourcetoESBwithin45seconds.Thewholeprocessistobeautomatically.ElectricmotorandstarterWorkingtestElectricmotorworkingtestshallbecarriedoutinaccordancewiththetestproceduressubmittedfrommachinery,outfitandother
53、part,andincombinationwiththeapplicablepartofthemachinery,outfitandotherpart.Duringthetest,therelevantparameterssuchascurrentandvoltageetc.shouldbechecked.Regardingcircuitinsulationresistancemeasurement,seeitem1.9below.Thecheckingshouldalsobemadeforwiringconnection,revolutiondirection,andnoiseandtemp
54、eratureriseatmotorbearingbymeansofhandfeeling.EmcystoptestoftheoilpumpsandfansItshallbeconfirmedthatthebreakersinthetableE-33onpages41,42,43shouldbetrippedwhentheemcystopbuttonisdepressed.TheresultsofabovetestarerecordedinattachedsheetE-33onpages41,42,43.SequentialstarttestItshallbeconfirmedthatpump
55、sandfansinthetableE-34onpage44startautomaticallyinsequencewhenpowersupplyisrestoredafterblack-out.TheresultsofabovetestarerecordedinattachedsheetE-34onpage44.AutochangeovertestforessentialpumpsThestandbypumpsshallstartautomaticallyincaseoffailureofrunningpumps.Failureoftherunningpumpshallbemadeartif
56、icially.Thistestshallbecarriedoutinaccordancewiththetestproceduressubmittedfrommachinerypart.TheresultsoftheabovetestarerecordedinattachedsheetE-35onpage45.Automaticstartand/orstoptestItshallbeconfirmedthatpumpsstartand/orstopautomaticallyunderautomaticoperation.Autostartand/orstopsignalshallbemadea
57、rtificially.Thetestshallalsobeperformedfollowingthetestproceduresubmittedfrommachinerypart.TheresultsoftheabovetestarerecordedinattachedsheetE-36onpage46.CircuitInsulationResistanceMeasurementThisprocedureshallbeappliedtoelectricalinstallationresistancemeasurementafterelectricalcablesandequipmentare
58、installedonboard.Measureinsulationresistancebetweenconductorsandgroundusing500VD.C.megger.However,noinsulationresistancetestistobecarriedoutforthesemiconductorandelectroniccircuit.Thebranchedorsubsequentcircuitsuchaslightingcircuitscouldbemeasuredatthemaincircuitbreakercommonly.Itshallbeconfirmedtha
59、tthemeasuredvalueofoutgoingcircuitistobemorethanone(1)megaohm.Measurementresultsarerecordedinseparatedocument(notincludedinhere)BatteryandchargingdevicetestChargingtestChargingfunctionshallbechecked.TheresultoftestistoberecordedinattachedsheetE37onpage47.DischargingtestDischargingconditionshallbeche
60、ckedbyswitchedonthebatteryloadcircuits.TheresultoftestistoberecordedinattachedsheetE38onpage47.2LightingSystemWorkingtestItshallbeconfirmedthatthefollowinglightsworkproperly.NavigationandsignallightsNormallightsEmergencylightsThetestresultsarerecordedinsheet39onpage48.No. E-1TestRecordNo.1MAINGENSET
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 《IT终端设备的配置与维护》 课件 模块2-项目7 -任务2 笔记本电脑的日常维护
- 《混凝土结构设计原理(新形态活页式)》 课件 29.单筋矩形截面受弯构件正截面承载力计算习题(二)
- 金属门窗及类似制品项目建议书
- 2024年胃肠疾病诊疗专项考核试题及答案
- 运载火箭控制系统仿真实时处理系统项目可行性报告
- 2023-2024学年高一年级上册期末真题综合测试北京卷C地理试题(解析版)
- 学年度教师述职报告
- -水工土建工程基础-绪论简介
- 厂区监控系统设计方案(2篇)
- 幼儿教师培训实施方案及流程(2篇)
- 嵌入式操作系统uCOS(共50张课件)
- 从“小米”看国产手机的商业模式创新
- 2023年山东青岛西海岸新区“山东省公费师范生”招聘考试真题及答案
- 升降平台操作安全规程培训
- 三年级综合素养考核试题及答案
- 2024中国华电校园招聘高频考题难、易错点模拟试题(共500题)附带答案详解
- 海康威视公司融资策略研究
- 现场监督工作管理的标准与规范
- 纸巾新直播话术
- 卫生院及社区医疗服务项目建设进度和成果汇报课件
- 工程项目预算部职责
评论
0/150
提交评论