版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、40/40 自动化系统交流 施耐德自动化产品技术问题及解答9 施耐德自动化产品技术问题及解答9 tianguanghui,2009-01-16 10:03:45施耐德自动化产品技术问题及解答9367,问:请问TwidoSoft的Preferences对话框中Automatic backup选项的作用?“Automatic backup”选项仅当在线状态下,对一个应用做了修改后才起作用。即假如该选项被选中,则将在断开与PLC的连接前做一次自动备份。当从PC下载应用到PLC时,该选项不起作用,TwidoSoft将总是自己做备份368,问:Concept软件中XMIT和XXMIT指令有什么差不?Qu
2、antum PLC做Modbus主时能够通过 IEC Xmit, Xxmit and 984LL Xmit指令与其它支持Modbus协议的从设备进行Modbus通讯。Xxmit和Xmit指令只能工作在IEC工作方式,Xmit指令比Xxmit指令公布早,从编程配置方便角度动身,编程使用过程中建议使用Xxmit指令。984LL Xmit 功能块应用在984LL中。369,问:请问如何确定Twido操纵器最近一次停机的缘故?系统字%SW58包含了最近一次停机的代码。370,问:Unity Pro安装环境?标准要求 : PC 1.2GHz, 512M Ram, 4 Gb disk space 最小要求
3、 : PC 800Mhz, 256M Ram, 2 Gb disk space只能在Windows 2000 和XP上安装,不支持Windows98操作系统。一台PC机上不能同时安装两个不同版本的UNITY PRO,但能够和PL7 PRO 和 CONCEPT 共存于同一PC 机上。371,问:UNITY PRO光盘中带有MODBUS PLUS DRIVER吗?不带。372,问:安装UNITY PRO软件后,启动时出现错误提示:“Object store internal error, VirtualAlloc failed to allocate at any address - Not en
4、ough storage is available to process this”,是什么缘故?产生这种错误的缘故是:有另外的软件正在使用与UNITYPRO相同的内部存储区。检测的方法是同时运行所有的软件,依次禁止软件运行以推断与哪一个冲突。Powerword, 3721, Twinmos, item都有可能与UNITY PRO 产生冲突。373,问:Unity PRO支持XXMIT指令吗?目前版本Unity PRO(2.0)不支持XXMIT指令。374,问:当在Unity Pro 中打开concept 产生的.asc文件时,出现错误提示“Converter Dll for this ext
5、ension not found”,如何解决?这是由于在安装该软件时选择的是“Typical”,这种安装不包含Concept converter.解决方法:重新插入安装盘,选择“Modify”,再选择相关的converter进行安装,375,问:Concept程序如何样在Unity Pro中打开?需要进行转换。用Concept Converter 将Concept程序导出为一个*.acs文件,在Unity Pro中打开该文件即可。376,问:在unity双机热备系统中,用什么电缆连接两个140cpu67160 CPU?在unity双机热备系统中,用于连接两个140cpu67160 CPU的光纤
6、的订货号为:490NOR00 xx,xx代表以米为单位的长度:03,05,15。377,问:请问Unity Pro的Medium、Large、XLarge三个版本的区不?Unity Pro Medium支持Premium和Atrium PLC;Unity Pro Large支持Premium、Atrium和Quantum PLC;Unity Pro XLarge支持Premium、Atrium、Quantum和Quantum热备PLC。378,问:连接Unity Quantum PLC 140 CPU 6*1*0 到MB+网络的分站电缆是什么型号?用于连接上述PLC的MB+分站电缆为:990
7、NAD 218 10(2.4米) /990 NAD 218 30(6米)379,问:能不能通过Modem实现Concept编程软件和PLC的远程连接, 如能, 如何实现?Concept中的IEC方式支持变址寻址, 先生成一个数组变量XXXARRAY和一个整型变量CONTROL, 则其变址寻址的书写格式为XXXARRAY CONTROL,有关Concept中的IEC方式下的变址寻址有以下注意事项:1. 将PLC前面板的开关位置设置到”MEM”, 然后在Concept中设置PLC的Modbus口参数为: Modbus ASCII, 9600Baud, 7Data Bits, Even Parity
8、, 1 Stop Bit.2. 用标准串行电缆连接Modem和PC串口, 然后进超级终端, 配置串口并建立连接, 串口配置与Modbus口参数一致.3. 打开超级终端连接窗口, 输入相应的AT指令设置Modem, 并测试通讯.4. 输入ATDTxxxx (xxxx是与PLC连接的Modem的号码)进行拨号连接, 若连接成功, 返回”Connected 9600”, 同时Modem上指示灯显示已连接.5. 在超级终端连接窗口中选择”Disconnect”, 断开超级终端和Modem的连接, 但Modem间的连接依旧保留.可从Modem上指示灯推断连接状态.6. 启动Concept, 并与PLC连
9、接7. 要结束连接时, 先退出Concept, 然后通过Modem 断电, 或断开电话线, 或在超级终端连接窗口, 输入相应的AT指令断开拨号连接.380,问:如何卸载Unity Pro?unity pro 安装在4个目录:unity pro Security editor, Unity pro Types Library, Unity pro XL 和Unity pro xl hardware catalog。在操纵面板中用add/remove program分不删除,顺序无要求。381,问:当CPU型号为p57 4634 /5634时,如何配置TSX FPP 20/TSX FPP 200
10、?Unity premium中当CPU为 P57 4634 /5634时,目前版本(V2.0.2)不支持TSX FPP20和TSX FPP200,请在PL7 pro转换和系统配置时提醒用户注意。382,问:请问用PL7生成的项目文件*.STX,能用Unity Pro直接打开吗不能直接打开,必须通过转换。具体转换步骤如下:1、在PL7中,点击File Export Application,生成*.fef文件;2、在Unity Pro中,点击File Open,打开在第1步中生成的*.fef文件。383,问:电缆UNY XCA USB 033用来给哪些PLC编程?该电缆为USB口编程电缆,长度为3
11、.3米,只能给Premium TSX 57-454/4634/554/5634 和Quantum 140 CPU 65150/65160/67160 编程。384,问:当安装Unity Pro 时,出现错误提示“Path variable 求助:Quantum PLC之间的modbus通讯线如何做 求助:Quantum PLC之间的modbus通讯线如何做 回复(9) | 人气(150) | 收藏 | | 推举给版主 | 分享文章到: 初级工 贡献:0 帖子:17 注册:06-11-10 状态:离线 加为好友 发短消息 2011-04-27 17:07:55 楼主请问大伙儿modbus rs2
12、32协议的RJ45通讯线如何做,如何交叉举报 收藏 评分初级工 贡献:0 帖子:89 注册:01-10-26 状态:离线 加为好友 发短消息 2011-04-29 14:30:45 1楼 举报 评分初级工 贡献:0 帖子:17 注册:06-11-10 状态:离线 加为好友 发短消息 2011-04-29 17:08:27 2楼回复内容:我后来接出来了,跟你那个有点小出入,上传不了图啊,汗举报 评分初级工 贡献:0 帖子:17 注册:06-11-10 状态:离线 加为好友 发短消息 2011-04-30 08:42:10 3楼哈哈,现在能够了举报 评分初级工 贡献:0 帖子:17 注册:06-1
13、1-10 状态:离线 加为好友 发短消息 2011-04-30 08:45:54 4楼我发的那个图仅限与PLC和PLC之间的通讯,假如要做低端PLC RS232和NOM252的RJ45口的通讯线是另外一种接法,据讲M340的Modbus线又是另一种接法,施耐德的接口不统一,真是令我汗颜啊举报 评分初级工 贡献:0 帖子:12 注册:09-12-13 状态:离线 加为好友 发短消息 2011-05-03 14:35:36 5楼你明白汗颜是甚么意思吗举报 评分初级工 贡献:0 帖子:17 注册:06-11-10 状态:离线 加为好友 发短消息 2011-05-04 08:44:51 6楼那个是低端
14、PLC modbus口到NOM252的RJ45口的通讯线做法,与上面的图之因此不一样是由于PLC用不到RJ45中的DTR和DSR信号,因此把他们短路并与CPU引脚断开举报 评分初级工 贡献:0 帖子:17 注册:06-11-10 状态:离线 加为好友 发短消息 2011-05-04 08:46:32 7楼以上结论都通讯实验,采纳XXMIT通讯模块进行通讯举报 评分初级工 贡献:0 帖子:17 注册:06-11-10 状态:离线 加为好友 发短消息 2011-05-04 15:08:27 8楼高端CPU的RJ45端口到高端CPU的RJ45端口的RS232通讯只要把12交叉,34交叉,67短路即可
15、举报 评分初级工 贡献:0 帖子:17 注册:06-11-10 状态:离线 加为好友 发短消息 2011-05-04 15:09:41 9楼高端CPU的RJ45端口到高端CPU的RJ45端口的485通讯只需要125三根线直连,1,2是数据传输线,5是地线举报 评分回复笔名: 游客您好 请您先假如您还不是工控网会员 内容: 游客您好 请您先假如您还不是工控网会员 EMBED Forms.HTML:Hidden.1 EMBED Forms.HTML:Hidden.1 EMBED Forms.HTML:Hidden.1 EMBED Forms.HTML:Hidden.1 EMBED Forms.HT
16、ML:Hidden.1 显示签名 假如您还不是中国工控网()的注册用户,赶忙免费!中国工控网BBS经营许可证编号:京ICP证020079号。 请确认您的言论符合 及。 gongkongMP提示:公布“主题帖”+3分/篇;自己删除主题帖 -3分/篇;被治理员删除主题帖 6分/篇 中国工控网()版权所有 Copyright By gongkong北京市公安局海淀分局备案号:1101082160LoginLoginLoginJoinJoinJoinCommunitiesCommunitiesCommunitiesFeedsFeedsFeedsPost a MessagePost a MessageP
17、ost a MessageOverload!Overload!Overload!CCClogin password Remember me on this computer| | | | | | | | | | | | | | | | Welcome to C, the global online community of automation professionals. Customize views and feeds, subscribe to threads and topics.C - Nerds in Control HYPERLINK /from the Projects de
18、partment.Quantum PLC Modbus Plus PortPosted by Rajesh Sharma on 12 January, 2005 - 12:37 amI had a problem which I am unable to understand. I was checking Quantum PLC 113 for communication by Foxboro DCS & ABB Advant 450. Both DCS dont have Modbus Plus Hardware. We want to establish communication be
19、tween one DCS & quantum PLC.We had used cross RS-232 Cable for communication instead of what is specified by quantum catalog. We had no communication on Modbus Port by Foxboro & ABB DCS. By mistake we had connect RS-232 DCS port to Modbus Plus Port & it start communication. Modbus Plus is not suppos
20、ed to communicate on serial link. We than make RS-232 connection as per quantum catalog Pin 2 & 3 Cross 4 & 6 Cross, 7 & 8 short on both sides 1 & 5 short. After this connection Both DCS start communicate on Modbus Port of Quantum PLC.Now My question why Quantum PLC communicate on RS-232 cross cable
21、 connection on Modbus PLUS port? DCS dont have any Modbus PLUS Hardware. Request All expert to revert back ASAP.Regards Posted by Brad on 13 January, 2005 - 1:21 pmModicon modbus RTU ports are configured for baud rate, parity, data bits etc through the Concept programming package. By default 9600,8,
22、E,1. Now these ports are full hardware handshaking so unless you cross (or tie together on one end) RTS/CTS and DSR,DTR and DTD comms will not work.Your DCS cannot communicate on Modbus PLUS - implossible. Modbus PLUS is a variant of RS485 and is a token passing network.Now I cant remember for the 1
23、13 controllers (it is the case for 434/534 controllers) there are two slide switches on the font panel which changes the communication parameters between what is configured in Concept vs dafult settings of 9600,8,E,1. Check these vs Concept HELP files. Posted by Rajesh Sharma on 17 January, 2005 - 9
24、:01 amDear Mr. Brad,I full agree with you that Modbus PLUS should not communicate on RS-232 cable. But we all Foxboro,ABB engineers had seen by issuing query & getting response on Modbus Plus port. We also confused on this behaviour. Request Pl. answer if you have. We dont have word IMPOSSIBLE becau
25、se there are many cases where Vendors says it is impossible & we had seen same in front of them. Posted by Anonymous on 13 January, 2005 - 3:47 pmDear Rajesh,What you observed like communication, that was something else. Modbus Plus is an RS 485 based network with peer-to-peer communication.Modbus P
26、ort is using RS-232 signaling and different communication stack. Master polls the slaves after each other. In your case the Modbus Port #1 acts as Master port. Your DCS devices as a slave, I think.Ignore that communication signals. Posted by on 13 May, 2009 - 1:24 amModbus Plus protocol uses RS-485
27、for its multi-drop feature and is a Master-Slave protocol. It is supported by many manufactures. I have found it standard (or an option) in many medium voltage protection relays and meters. I suspect Foxboro and ABB offer a Modbus Plus interface module. These interfaces will allow engineers to confi
28、gure tables to specify blocks of boolean/integers/real/word data to & from the PLC.If your DCS has a serial port then use Modbus protocol to pass data between it and the PLC. It uses RS-232 for a point-to-point serial connection. Connect using an off the shelf serial cable c/w null modem between the
29、 DCS serial port and the Quantum CPU534 Comm 1 port or buy a Schneider Modbus communication cable. Set the PLC slider selector switch to RTU and configure communication settings to 9600, even, 8, 1.Have you considered Modbus Plus over Ethernet (MBE)? Posted by balberoz on 25 January, 2010 - 10:47 pmThe cable connection principle are the same device application will be used cross cable connection while for the different application (ex: Pc to sw) will be used direct conne
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2027届进贤县四上数学期末复习检测模拟试题含解析
- 2026年“安全生产月”活动安全知识竞赛试题测试卷附答案
- 2027届江西省上饶市弋阳县三上数学期末经典模拟试题含解析
- 2027届江苏省泰州市泰兴市数学四年级第一学期期末学业水平测试模拟试题含解析
- 佳木斯市桦川县2027届四上数学期末统考模拟试题含解析
- DB53-T 911.10-2022 能源资源计量数据采集与监测指南 第10部分:工业硅企业
- 2026年山东省青岛市高考考前提分生物仿真卷含解析
- 江苏省苏州市2025-2026学年高考生物押题试卷含解析
- 2026中国新能源投资行业市场深度调研及投资前景与投资策略研究报告
- 2026中国智能清洁设备市场需求深度研究与发展趋势预测分析报告
- 2026 年秋季开学:智慧课堂建设教师应用培训
- 2026年云南省基层法律服务考试真题及答案
- (2026年)儿童心肺复苏课件
- 情感识别对心理危机干预效果课题申报书
- 2024中建临建标准化图册(可编辑版)
- 肿瘤科实习生肺癌
- 第六章质量与密度各节学案-人教版八年级上册物理
- 高三英语上学期开学第一课课件
- 医德医风知识教育培训课件
- 上海市《超低能耗建筑设计标准(公共建筑)》
- 卒中的中医课件
评论
0/150
提交评论