差热扫描分析仪培训教程_第1页
差热扫描分析仪培训教程_第2页
差热扫描分析仪培训教程_第3页
差热扫描分析仪培训教程_第4页
差热扫描分析仪培训教程_第5页
已阅读5页,还剩116页未读, 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

差热扫描分析仪培训教程第1页/共121页DSC:TerminologyAmorphousPhase-Theportionofmaterialwhosemoleculesarerandomlyorientedinspace.Liquidsandglassyorrubberysolids.Thermosetsandsomethermoplastics.CrystallinePhase-Theportionofmaterialwhosemoleculesareregularlyarrangedintowelldefinedstructuresconsistingofrepeatunits.Veryfewpolymersare100%crystalline.Semi-crystallinePolymers-Polymerswhosesolidphasesarepartiallyamorphousandpartiallycrystalline.Mostcommonthermoplasticsaresemi-crystalline.Melting-Theendothermictransitionuponheatingfromacrystallinesolidtotheliquidstate.Thisprocessisalsocalledfusion.Themeltisanothertermforthepolymerliquidphase.Crystallization-Theexothermictransitionuponcoolingfromliquidtocrystallinesolid.Crystallizationisafunctionoftimeandtemperature.ColdCrystallization-Theexothermictransitionuponheatingfromtheamorphousrubberystatetothecrystallinestate.Thisonlyoccursinsemi-crystallinepolymersthathavebeenquenched(veryrapidlycooledfromthemelt)intoahighlyamorphousstate.EnthalpyofMelting/Crystallization-Theheatenergyrequiredformeltingorreleaseduponcrystallization.ThisiscalculatedbyintegratingtheareaoftheDSCpeakonatimebasis.第2页/共121页TAInstrumentsDSC’sDSC2010DSC2910DSC2920第3页/共121页Q系列™DSCQ2000是顶级的带有多种可选配置的研究级DSCQ200是具有扩展功能的研究级DSCQ20是基本型DSC第4页/共121页DSCQ20P&DSCQ2000withPressureCell第5页/共121页DSC光量热附件第6页/共121页SDTQ600SDTQ600同步DSC-TGA:同时测量热流和重量变化信号第7页/共121页DSC:典型DSC转变温度热流->放热玻璃化转变结晶熔化交联(固化)氧化或分解第8页/共121页UnderstandingDSCSignalsHeatFlowRelativeHeatFlow:measuredbyallDSCsexceptTAQ2000.Theabsolutevalueofthesignalisnotrelevant,onlyabsolutechangesareused.AbsoluteHeatFlow:usedbyQ2000.Dividingthesignalbythemeasuredheatingrateconvertstheheatflowsignalintoaheatcapacitysignal第9页/共121页Fromdesktop,double-clickonQSeriesExplorerIcon第10页/共121页QSeriesExplorershowsalltheinstrumentsattachedtoyoursystem第11页/共121页第12页/共121页SignalDisplay第13页/共121页MethodSegments第14页/共121页Real-TimePlot第15页/共121页Summary,Procedures,&Notes第16页/共121页RunsintheSequence第17页/共121页CalibrationQ200&Q2000Tzero™CalibrationCellConstantandTemperatureCalibrationQ20BaselineCalibrationCellConstantandTemperatureCalibration第18页/共121页CalibrationQ200&Q2000Tzero™CalibrationCellConstantandTemperatureCalibrationQ20BaselineCalibrationCellConstantandTemperatureCalibration第19页/共121页TobegincalibrationstartDSCCalibrationWizard第20页/共121页SelectHeatflowsignal&typeofcoolerQ2000=T4PQ200=T4Q20=T1第21页/共121页SelectwhichcalibrationtoperformTzeroCalibration第22页/共121页Enterparametersforfirstrun(emptycell)第23页/共121页Startexperiment第24页/共121页Enterweightofsapphiresamples第25页/共121页Whenruniscompleted,capacitance&resistanceareplottedandsaved第26页/共121页EnterparametersforIndiumsampleAlwaysrunIndiumforCellConstant第27页/共121页EntertemperaturesforIndiumrun第28页/共121页Startexperiment第29页/共121页Dataisanalyzedautomatically第30页/共121页第31页/共121页CalibrationQ200&Q2000Tzero™CalibrationCellConstantandTemperatureCalibrationQ20BaselineCalibrationCellConstantandTemperatureCalibration第32页/共121页TobegincalibrationstartDSCCalibrationWizard第33页/共121页第34页/共121页Selecttypeofcalibrationtorun第35页/共121页Enterparameters第36页/共121页Reviewsummary第37页/共121页Entersampleinformation第38页/共121页Finishenteringsampleinformation第39页/共121页Reviewchecklist第40页/共121页Baselinecalibrationrunning第41页/共121页Startcalibrationanalysis第42页/共121页Fileisopenedautomatically第43页/共121页SelectlimitsthenclickonLimitsOkbutton第44页/共121页ClickonAccepttosavecalibration第45页/共121页Oncethefileisanalyzedandtheresultsaresaved,acheckmarkappearsnexttothefilename第46页/共121页TobegincalibrationstartDSCCalibrationWizard第47页/共121页第48页/共121页Selecttypeofcalibrationtorun第49页/共121页Enterparameters第50页/共121页Reviewsummary第51页/共121页Entersampleinformation第52页/共121页Finishenteringsampleinformation第53页/共121页Reviewchecklist第54页/共121页Startcalibrationanalysis第55页/共121页Fileisopenedandanalyzedautomatically.Clickanalyzetochangelimits,oraccept第56页/共121页TzeroHeatFlowEquationHeatFlowSensorModelHowdowecalculatethese?Besidesthethreetemperatures(Ts,Tr,T0);whatothervaluesdoweneedtocalculateHeatFlow?第57页/共121页MeasuringtheC’s&R’sTzero™CalibrationcalculatestheC’s&R’sCalibrationisamisnomer,THISISNOTACALIBRATION,butratherameasurementoftheCapacitance(C)andResistance(R)ofeachDSCcellAfterdeterminationofthesevalues,theycanbeusedintheFourTermHeatFlowEquationshowedpreviously第58页/共121页MeasuringtheC’s&R’sPreformedusingTzero™CalibrationWizardRunEmptyCellRunSapphireonbothSample&Referenceside第59页/共121页AfewwordsabouttheCsandRsThecurvesshouldbesmoothandcontinuous,withoutevidenceofnoiseorartifactsCapacitancevaluesshouldincreasewithtemperature(withadecreasingslope)Resistancevaluesshoulddecreasewithtemperature(alsowithadecreasingslope)Itisnotunusualfortheretobeadifferencebetweenthetwosides,althoughoftentheyareveryclosetoidentical第60页/共121页GoodTzero™CalibrationRun第61页/共121页EnableandSelectDiagnosticSignalsCheckthisbox!第62页/共121页EnableandSelectDiagnosticSignalsSelect1-8foranRCSorallofthemforanLNCSMoreonDiagnosticSignalslater第63页/共121页AdvancedTzero™TechnologyDuringtransitionsandMDSC®experiments,theheatingratesofthesamplepan,samplecalorimeter,referencepanandreferencecalorimetermaybeverydifferent.Samplepanshavethermalresistanceandheatcapacityandsampleandreferencepansrarelyhavethesamemass.AdvancedTzeroincludestheheatcapacityofthepansandtheheatingratedifferencesbetweenthesampleandreferencecalorimetersandpans.Peaksaretallerandsharper,hencebothresolutionandsensitivityaredramaticallyimproved.第64页/共121页AdvancedTzero™Model

AdvancedTzeroisafurtherrefinementoftheTzeromodelandtakesthemeasurementuptothesamplepan,onestepclosertotheactualsample

qsamRs

Rr

qs

qr

Cs

Cr

Tr

T0

Ts

Rp

Rp

mprcpan

Tps

Tpr

Rs

Rr

qs

qr

Cs

Cr

Tr

T0

Ts

Rp

Rp

mprcpan

Tps

Tpr

mpscpan

mpscpan

mAdvancedTzeromodelincludesthePansTzeromodelstheCalorimetersRpCpanRsQ1000Q100第65页/共121页AdvancedTzero™ThepantypeMUSTmatchthepanthatyouareusingBesureandenterpanweights第66页/共121页Coolers RefrigeratedCoolingAccessory(RCS)

LiquidNitrogenCoolingAccessory(LNCS)

FinnedAirCoolingAccessory(FACS)

QuenchCoolingAccessory(QCA)第67页/共121页CoolersCoolingdevicesitsonflange

Nickelcoolingrodstransfercoolingtofurnace/cell第68页/共121页Usedtoselecttypeofcooler,andtospecifystatusbetweenruns第69页/共121页RCSTemperatureRange-90°Cto550°C第70页/共121页RCSTemperatureRange-90°Cto550°CCellpurgeandbasepurgerequiredwhenRCSisrunningSecondarypurgeisoptional,butrecommendedwhenusinginhighlyhumidenvironmentsDryN2tocoolinggasportonbackofDSC第71页/共121页RCSTemperatureRange-90°Cto550°CCellpurgeandbasepurgerequiredwhenRCSisrunningSecondarypurgeisoptional,butrecommendedwhenusinginhighlyhumidenvironmentsDryN2tocoolinggasportonbackofDSCEnsurethatcellremainsaboveambientusingunloadrangeandstandbytemperature第72页/共121页Unloadrangeisthetemperaturethatthecellwillgotoattheendofarun第73页/共121页Ifunloadtemperaturerangeisnotactive,cellcanbecontrolledbyusingstandbytemperature第74页/共121页第75页/共121页LNCSTemperatureRange-180°Cto550°C第76页/共121页LNCSTemperatureRange-180°Cto550°CCellpurgeandbasepurgerequiredwhenLNCSisrunningSecondarypurgeisoptional,butrecommendedwhenusinginhighlyhumidenvironmentsDryN2tocoolinggasportonbackofDSCEnsurethatcellremainsaboveambientusingunloadrangeandstandbytemperature第77页/共121页FACSTemperatureRangeAmbientto725°C

第78页/共121页FACSTemperatureRangeAmbientto725°C

Dryairtocoolinggasport

Quenchcooleravailabletocooldownquickerbetweenruns(notforsub-ambientuse)第79页/共121页QCATemperatureRange-180°Cto550°CCellpurgeandbasepurgerequiredwhenusingaQCA第80页/共121页TopicKeepingyourDSCcellcleanCalibrationSamplePreparationThermalMethod第81页/共121页KeepingtheDSCCellCleanOneofthefirststepstoensuringgooddataistokeeptheDSCcellcleanHowdoDSCcellsgetdirty?DecomposingsamplesduringDSCrunsSamplesspillingoutofthepanTransferfrombottomofpantosensor第82页/共121页HowdowekeepDSCcellsclean?DONOTDECOMPOSESAMPLESINTHEDSCCELL!!!RunTGAtodeterminethedecompositiontemperatureStaybelowthattemperature!MakesurebottomofpansstaycleanUselidsUsehermeticpansifnecessary第83页/共121页TGAGivesDecompositionTemperature第84页/共121页CleaningCellIfthecellgetsdirtyCleanw/brushBrushgentlybothsensorsandcellifnecessaryBecarefulwiththeTzero™thermocoupleBlowoutanyremainingparticles第85页/共121页BrushingtheSampleSensor第86页/共121页HeatFlowCalibration(CellConstant)HeatFlowCalibrationofDifferentialScanningCalorimeters–ASTME-968EnthalpyCalibrationPerformedusingCalibrationWizardOneRunIndiummetalSampleWeight1-5mgPre-meltsamplethefirsttimeyourunitHeatingrateof10°C/minDependentuponpurgegas第87页/共121页CellConstantThecellconstantiscalculatedastheratioofthetheoreticalheatoffusionofastandardmaterial,tothemeasuredheatoffusion

CellConstantshouldbe0.95-1.20inN2第88页/共121页第89页/共121页TemperatureCalibrationTemperatureCalibrationofDifferentialScanningCalorimeters–ASTME-967PerformedusingCalibrationWizardIndiumCellconstantrunalsoperformstemperaturecalibrationCandoupto5standardsPuremetalstypicallyused-In,Sn,Zn,PbWe’vefoundthatontheQseriesDSC’sonetemperaturecalibrationpointisallthatisusuallyneeded第90页/共121页第91页/共121页SamplePans Typeofpandependson-SampleformVolatilizationTemperaturerangeUselightest,flattestpanpossibleAlwaysusereferencepanofthesametypeassamplepan第92页/共121页StandardDSCPans(Crimped)Pan&lidweighs~23mg,bottomofpanisflatUsedforsolidnon-volatilesamplesAlwaysuselid(seeexceptions)LidimprovesthermalcontactKeepssamplefrommovingExceptionstousingalidRunningoxidativeexperimentRunningPCAexperiment第93页/共121页StandardDSCPans(Crimped)Crimpedpansareavailablein:Aluminum -upto600°CCopper -upto725°C(inN2)Gold -upto725°C StandardPanswithoutlidsGraphite -upto725°C(inN2)Platinum -upto725°C 第94页/共121页HermeticPans(Sealed)Pan&Lidweigh~55mg,bottomofpanisnotasflatasstdpansUsedforliquidsamplesandsampleswithvolatilesAlwaysuselid(sameexceptionsasbefore)Aftersealingpans,shouldformdome第95页/共121页HermeticPans(Sealed)HermeticPansareavailablein:Aluminum–<600°C;<3atm(300kPagage)AlodinedAluminum-<600°C;<3atm

(300kPagage)(Foraqueoussamples)Gold–<725°C,<6atm(600kPagage)SpecializedSealedPansHighVolume-100µL;<250°C;600psig(4.1MPa)HighPressure-35µL;<300°C;1450psig(10MPa)Note:3atmisapproximately44psig第96页/共121页ItDoesMatterWhatPanyouuseMonohydratePharmaceuticalsample第97页/共121页SampleShapeKeepsamplethinCoverasmuchasthebottomofpanaspossible第98页/共121页SampleShapeCutsampletomakethin,don’tcrushIfpellet,cutcrosssection第99页/共121页SampleShapeCutsampletomakethin,don’tcrushIfpellet,cutcrosssectionIfpowder,spreadevenlyoverthebottomofthepan第100页/共121页UsingSamplePressWhenusingcrimpedpans,don’tovercrimpBottomofpanshouldremainflataftercrimpingWhenusingHermeticpans,alittlemorepressureisneededHermeticpansaresealedbyformingacoldwieldontheAluminumpansCrimpedPansHermeticPansGoodBadSealedNotSealed第101页/共121页SampleSizeLargersampleswillincreasesensitivity but…………….Largersampleswilldecreaseresolution

Goalistohaveheatflowof0.1-10mWgoingthroughatransition第102页/共121页SampleSizeSamplesizedependsonwhatyouaremeasuringIfrunninganextremelyreactivesample(likeanexplosive)runverysmallsamples(<1mg)Pureorganicmaterials,pharmaceuticals(1-5mg)Polymers-~10mgComposites–15-20mg第103页/共121页PurgeGasPurgegasshouldalwaysbeusedduringDSCexperimentsProvidesdry,inertatmosphereEnsuresevenheatingHelpssweepawayanyoffgasesthatmightbereleasedNitroge

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论