




版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
××××××××工程施工方案投标人(盖章):******日期书目一、投标单位投标人资质·····················································二、公司主要业绩···························································三、项目经理资质、业绩、项目班子配置及管理阅历·····························四、施工主要机械设备的配置·················································五、劳动力投入支配及其保证措施·············································六、限制质量的措施·························································七、工期进度支配及保证措施·少·············································八、关键施工技术:工艺及工程项目实施的重点、难点和解决方案·················九、合同管理及竣工验收资料的编制···········································十、与招标人指定分包公司的协调管理·········································十一、平安文明施工措施·····················································十二、质量保证和质量违约责任承诺···········································十三、保修期的服务承诺·····················································十四、对本工程的合理化建议···················································第一章投标单位资质其次章公司主要业绩第三章项目经理资质业绩项目班子配置编号姓名职称年龄资格经验(业绩)1234567891011第四章施工主要机械设备的配置第一节机械设备投入支配及检测设备本工程拟采纳多种机况良好的先进的机械设备,进场前,管理人员要清点机械设备及检测设备,列出清单,看能不能满足投入支配的须要;并派机修工调试机械设备,有故障的机械修理好后才能进场。施工机械设备投入量支配如下图所示:1、施工机械设备投入量支配序号设备名称(型号)台数功率(KW)进场时间1勾机开工即进地场2打桩机开工即进地场3自卸汽车开工即进地场4沙浆捣拌机开工即进地场5弯切筋机开工即进地场6木工作圆盘踞开工即进地场7沟通电焊机开工即进地场8蛙式打夯机开工即进地场9水泵开工即进地场10插入振动器开工即进地场11平板式振动器开工即进地场12斗车开工即进地场13全站仪开工即进地场14水准仪开工即进地场15钢卷尺开工即进地场16米尺10开工即进地场第五章劳动力投入支配及其保证措施第一节劳动力和材料投入支配本工程工作面大,工期紧,施工时需投入的设备、人员、材料多,为满足施工须要,进场前先编制好设备、材料、人员须要量及进场支配,贮备足够的工程须要的设备、材料、及娴熟的技工与劳力,然后依据施工进度,按进度支配,人员分批进场,专人负责材料选购 ,设备及材料利用公司的车辆分批运到工地指定地点堆放。设备、人员须要量及进场支配如下图所示:1、劳动力投入支配序号工种所需人数备注1土方工122桩工83砼工154木工155铁工126水工157装修工108普工209电工310机械工5其次节劳动力投入保证措施1、开工前,公司人事及行政部依据公司的运作状况,开会探讨组建项目经理部及劳动力班组事宜,委派有阅历及责任感的管理人员进驻该工程进行施工管理,并按制订好的支配抽调各种专业的施工班组,如发觉劳动力不足,即由人事部招骋扩充。每个班组长要事先对本班组的工人进行技术考核评定,把技术不过硬的工人替换,力保有足够的劳动力调用。2、选择信誉好、实力强的施工作业队伍,依据本施工组织设计制定的劳动力需用支配,针对现场施工状况,编制切合实际的阶段.性劳动力需用支配,并刚好将劳动力需用支配传递至劳务分包单位。3、在与各施工班组的合同中明确约定必需按我单位的劳动力支配供应足够的劳动力,并明确阶段性工期和总工期提前完成或延迟完成奖罚措施;同时,合同中特殊约定保证足够劳动力的经济奖罚措施。4、新进场工人必需考核合格后才能上岗,保证工人技术素养和娴熟程度,素养差、技术生疏的工人坚决更换。第六章限制质量的措施第一节施工方案及施工方法本工程全部在君兰高尔夫后九洞范围内,包括桥梁、小卖部、休闲亭、泵房、挡土墙等构笋物,主要涉及该构筑物主体及装饰工程,且各构筑物间比较分散,施工场地内存在同高尔夫造型单位交叉作业。总之工程比较零星,涉及的工种多,工期相对较短,结合本工程的特点、工期、施工方法及工艺等因素,拟将本工程划分为多个施工段进行施工,每个单体工程为一个施工段,这样既不影响结构的整体性,并且加快了工程进度,同时各个施工段的贪源共享,相互促进、激励,对提高工程质量、加快工程进度起到主动作用。施工过程中先施工难度大的分项工程和本项目中的灵魂工程,其它工程则附之,抓住主要项目及关键路径,其它次要项目则迎刃而解。土建工程总体施工程序采纳先地下、后地上、先主体、后围护,先结构、后装饰、土建安装协作的一般原则。各专业施工班组,通过劳动量的调整,分别在各施工段的流水节拍均相等,按施工依次的先后间断地投入各层各段工作,做到相互协调、紧密连接。在施工过程中必需充分考虑相互的影响,留意相互间的协作和连接,最大限度地优化管理,以便充分利用机械设备、劳动力和材料,争取时间,使整个工程的施工有条不紊顺当进行,确保在支配工期内一按质量完成工程,并清场退场。其次节主要分项工程施工工艺图一、土石方工程施工工艺流程施工放线机械开工挖人工开挖二、桩基础工程施工工艺流程施工作打算测量定位桩机就位吊桩定位锤击贯入验桩三、钢筋混凝土工程工艺流程测量放线模板安装加固钢筋制安砼浇筑砼养护拆除模板四、砌筑工程工艺流程淋砖打砂浆施工放线砌砖五、抹灰工程工艺流程六、铺贴工艺流程基层处理抹底灰弹线浸砖铺贴纹缝清洗墙面质量管理保证体质量管理保证体工程质量一次验收合格,争取优质工程质量工作检查现场QC小组活动质量第一为用户服务下道工作序是用户制定教化支配督促按设计图施工进行技术交底编制质量支配督促进行测量复核施工限制保证项目部成立质量管理领导小组提高质量意识贯彻质量标准推行全面质量管理经济法规分包单位成立质量管理领导小组TQC教化应用新技术检查分包单位创优成果按合同进行限制完善计量支付手续制定奖罚措施明确分包单位责任检查落实接受业主和监理监督奖优罚劣定期不定期质量检查加强不合格品处置力度质量评定作业队质量小组分包单位创优规划制度保证思想保证思想保证组织保证技术保证经济责任制经济责任制明确工作制度和标准总结宣扬改进工作质量总结宣扬改进工作质量经济兑现反馈反馈2质量创优组织机构组长:项目部经理副组长:项目部技术负责人组员:项目副经理、项目部技术、质量相关各部。职责:参与工程整体创优策划,依据创优总体策划大纲,制定阶段创和指导责任部门进行创工作的实施,并对阶段目标的实施状况定期监督,检查和总结。3项目部各主要相关部门质量职责3.1项目经理:1)支配和部署项目班组的施工工作,保证工程按支配实施。2)领导项目各部门和施工班组全面落实行质量支配。3)协调项目内外关系。4)细致处理好日常质量工作中出现的问题,重大问题应上报公司创优小组。5)每周召开一次工程管理例会,会上应解决质量活动中的实际问题。3.2工程技术部:1)搞好技术革新和“新技术”应用。2)细致学习和熟识图纸,主动参与图纸会审,编制施工组织设计及切实可行的技术管理方案,为项目高效、低耗、平安的目标在技术上供应牢靠保证。3)做好每道工序的技术交底工作,召开由技术员、质检员和施工班组参与的技术交底会,将技术交底内容明确请晰地传达到每一个作业人员。4)制定好管道工程质量通病的防范措施,作好隐藏工程验收工作。5)细致作好质量检查的核定工作,以及施工放线的核定工作,对出现的问题细致分析,找出缘由,提出处理看法,并细致总结阅历教训。6)常常深化施工第一线,对现场出现的问题刚好订正。7)工程资料的收集,整理工作,以及交工资料的编制工作。.8)技术上协调好与分包施工队伍的关系以及其它内外关系。3.3质量检验部:1)协作技术人员督促班组落实技术交底要求。2)负责确认工序自检状况,组织专检和工序交接检,作好质量记录,核定班组质量等级。3)确保各分部分项工程达到创优质量。4)负责整理施工过程的检验记录。3.4设备材料部:1)严格按物资选购 程序选购 ,确保物资选购 质量。2)组织对工程物资的验证,确保运用合格产品。3)选购 资料及验证记录的收集整理。第七章工期进度支配及保证措施第一节施工进度支配本工程支配70个日历天施工工期,开工日期以招标人发出的中标通知日起计。但该工程量较大工序较多,且工期短,因此需合理利用时间,充分利用工作面及场地,在不影响质量及平安的状况下在多个工作面同时开工,为保证按质按量准时竣工,防止其它不行预见的因素,该工程尽量在前期加快施工进度,为后期工程争取时间。施工进度总体支配表详见下表:其次节各阶段进度的保证措施及违约责任承诺为使各个阶段的施工进度能按支配进度表实施,不影响后续工序及整个工程的工期,各专业工种须协调作业,部分工序须同步进行施工。一、确保工程进度的祖织措施(1)组织强有力的项目管理班子,落实管理岗位的职责。建立各工种专人负责,既分工又协作的有机管理网络,对工程进度、质量、平安进行全过程限制,并进行考核。<2)将本工程列为公司的一号重点管理项目。公司领导及各有关处室,全力以赴,围绕工程运转,每月对本工程进行一次大检查,对资金、物资、设备、劳动力、技术协作和质量管理,作全力支持,确保满足各施工阶段的须要。<3)建立工程协调会制度,加强总承包与各专业分包单位的协作和协调,刚好同有关分包单位互通信息,驾驭施工动态,协调内部各专业工种之间的工作,留意后续工序的打算,布置工序之间的交接,刚好解决施工。中出现的各类问题。各专业分包单位要依据总承包的施工进度支配编制实施作业支配,经总承包单位综合平衡并确认后付诸实施。常常和定期检查支配实施状况,包括工程形象进度、资源供应和管理工作进展。(4)强化现场管理,落实责、权、利。对各道工序严格把关,避开返工。项目经理部内部实行部位考核制度,针对各施工工序的实际进度,结合各岗位人员的工作实绩进行奖罚;同样,对各作业班组实行工程进度部位考核,保质按期完成支配进度部位的赐予嘉奖,反之则进行罚款。通过奖优罚劣,充分调动管理人员和作业班组的生产主动性,以确保工程进度支配的肃穆性。二、确保工程进度的管理措施(1)依据施工总进度支配,编制各时期较为具体的实施支配,包括年度、季度和月进度支配。依据月支配编制每周作业支配,用来向各作业班组下达任务。每周召开一次平衡调度会,刚好解决劳动力、施工材料、设备调度、成品加工品进场支配等问题,通过周支配保证月支配,通过月支配保证季度支配,从而确保工程总进度支配目标的实现。(2)紧紧抓住施工网络支配中关键线路上各分项工作的施工周期,刚好完成关键线路上的工作。对位于非关键线路上的工作,往往有若干机动时间即时差。在工作完成日期适当挪动不影响支配工期的前提下,合理利用这些时差,可以更有利地支配施工机械和劳动力的流水施工、削减窝工、提高工效。(3)编制各时期各种材料货源供应量支配。刚好了解材料、设备供应动态,对缺口物资要做到心中有数,并主动协调调剂,对于需外加工的构配件,市场上紧俏的材料和配件,应估计定货、选购 、加工、运输和进场(库)时间,提前编制和落实各类货源供应量支配。如对工程进度产生影响时,要提出调整局部进度支配和有效的补救措施,使总进度支配顺当实施。C4)细心组织、科学施工。依据划分的施工区域,合理平衡和支配劳动力,组织各工种的穿插和搭接,组织平行流水、立体交叉作业。主体结构分次进行中间验收,以利于装饰施工刚好插入。(5)土建扫尾阶段,组织混合班组,分层分区做好装饰扫尾工作。竣工前组织一次初验,发觉不足之处刚好更改,确保竣工验收一次通过。各类技术资料在扫尾工作前10天起先整理、汇总,并尽早提交质检站审核。(6)实行弹性工作时间,主导工序的工种要组织必要的加班加点,作业班组二班轮换,延长工程整体作业时间。在春节、双抢期间,做好一线工人留岗的思想工作,保证有足够的工人上班,妥当支配施工时间,搞好后勤供应工作,并在经济上赐予肯定的补贴,使施工不间断地连续进行。(7)做好雨天及其它恶劣气候的施工后备工作,合理支配、穿插室内、室外工程的施工。(8)在工程施工中与建设、设计、质监、监理等保持常常性的联系,以便刚好将信息反馈回项目部,下达落实到各作业点和作业组。三、确保工程进度的设备与技术投入(1)投入足够的施工机械,为工程整体如期竣工创建良好的条件。(2)结构模板采纳胶合板为面板的工具式模板,钢筋采纳闪光对焊和电渣压力焊技术,在保证质量的前提下,对加快工程进度起到了主动的作用。(3)现场配备柴油发电机,在出现停电的突发状况下能供应200KW的用电量。(4)主动采纳有利于保证质量、加快工程进度的新技术、新工艺才新叮材料。(5)应用计算机进行工程进度管理。利用计算机制作网络支配,依据施工过程中的实际状况刚好调整施工支配,对工程进行动态智能化管理,真正起到指导施工作业的作用。四、确保工程进度对专业分包单位管理1:项目经理部管理人员必需细致学习总承包与建设单位签订的合同文本,全面理解和驾驭合同文本的要求。在工程实施中,以合同文本为依据,自始至终将其贯彻执行到整个总承包施工管理全过程中去,确保工程优质如期完成。2.按合同规定的承包施工范围内的工程质量、工期、平安、文明施工等要求,总承包编制具体、完善的施工组织设计,由项目技术负责人签发后,进行实施。3.以食同规定的总工期要求,编制本工程施工总进度网络支配,以此有效地对工程进度支配进行总限制。4.以总工期为依据,编制工程阶段实施支配(施工打算支配;劳动力进场支配;施工材料、设备、机具进场支配;进口设备、材料进场支配;各分项工程分包队伍进场支配等)。5.将总合同的条款要求,分解纳入相对应的分项合同中,使分包合同对质量、工期、平安、文明施工等完全处于受控状态之中,确保工程如期完成。6.各专业分包单位应按与总承包签定的合同要求,编制出分包工程分部分项具体的施工组织设计,报请总承包审批经同意后才能进行施工。7.总承包每周定期与分包单位召开一次协调会,解决生产过程中发生的问题和存在的困难。按总承包周支配要求检查分包每周工作完成状况及布置下周施工生产任务。8.总承包现场管理人员与分包管理人员,在施工高峰时,每天收工前开一次碰头会,协商解决当天及其次天生产过程中发生的问题,应由总承包负责解决的问题决不拖迟和延期。9.施工过程中各类业务联系,除必需口头通知外,总承包均以书面指示书刚好发给各分包执行。10.总承包做好各分包的工程进度款审核签证工作。11.总承包关切、指导各分包单位的工作,刚好快速将建设单位、监理单位发给的工程指令、通知、联系单看法中有关分包工程的部分传送给指定分包单位并督促该指令、通知、联系单看法快速得到执行;解决处理、协商分包有关事宜,向指定分包人供应己在现场设置的全部设施(如脚手架、机械设备、贮存仓库、堆场、合理的施工作业空间、施工及照明用电、用水、其它临时设施及所需的标高、定位点、线等技术资料),以确保工程顺当开展。12.专业分包单位必需满足业主与总承包所签的合约要求,在工期、质量、平安、现场文明施工等方面接受总承包的管理。由于分包单位不能满足总承包合理的管理要求,而造成业主及总承包的一切损失,应由专业分包单位担当。五、对专业分包单位进度限制各分包单位均应依据施工总进度网络支配编制分级网络支配,与总进度支配连接,并受总进度支配的限制。土建进场后做些施工打算工作就可干脆进行基础土方开挖的施工。依据施工总进度支配,安装工程应在土方工程开工后进场,进行基础的防雷接地等工作,此后,随着结构的进度进行各类管线、管道、埋件的预埋预留。结构工程结束后,与装饰工程同时起先施工安装工程。主体结构完后,在室内装饰装修的同时可进行外墙装饰施工。本工程的安装在结构阶段协作土建预留预埋,在装饰阶段与土建穿插进行安装。需由专业分包单位施工的二次装饰装修,在内粉刷及地坪完成若干层数后即可插入施工。六、各阶段进度保证措施:a、打桩阶段:此阶段主要运用机械进行施工,我司一进场即投入桩机进场施工,并落实机修人员,一但发生故障马上抢修,确保有机况良好的机械施工。在不影响旁边居民休息和生活的状况下实行轮班作业,尽量加班加点作业,形成人停机不停的高效作业方式,加快桩基础的进度。b、基础工程阶段:此阶段要搞好测量放线,车由线要精确,避开返工拖延工期。土方工程一_公舒;袱·主要采纳机械作业,人工协助,基坑基槽采纳机械开挖,桩间土方采纳人工开挖。在开挖基础时要打算好抽水设备,如有地下水涌出则实行措施进行排水。基础开挖成形肯定工作面后,即开展该工作面的承台、基础梁、地下连续墙等基础工程的施工,使整个基础工程的各个工序交替进行,充分利用工作面、劳动力及机械设备。c、主体工程阶段:木工、铁工、水工用量较大,各班组各工种要配备足够数量的劳动力,避开由于工种配比失调或劳动力不足造成窝工;钢材、商品砼、砌块等材料,要事先组织好货源,支配足够的运输车辆,保证有足够的材料供应,从而保证该阶段的施工进度。d、装修工程阶段:此阶段由:外墙装饰、楼地面装饰、内墙抹灰、天花抹灰、屋面防水、安装门窗等项目组成:工序多,用工量也大,且由于工艺的缘由要等(局部)主体完成后才能施工,故要抓紧时间,充分利用工作面,投入足够的装修工人:当每层的砌筑工程完成后,即进行该层内墙及天花抹灰等工序施工;主体全部完成后,从上到下进行外墙装饰施工,外墙装饰分几个工作面进行;在不影响其它工序并符合规范的状况下,各工序应同时施工,以加快工程进度。e,安装工程阶段:安装工程属后期工程,包括配电、给排水等专业,涉及工种多,须合理支配及协调施工,使工程顺当高效进行。七、违约责任承诺:我公司将严格依据进度支配组织施工,合理支配劳动力,确保各阶段及整个施工期能按支配完成,并且与各施工班组签订完成支配责任书,若施工班组不按进度支配完成任务,则调换新班组进场代替旧班组施工。如本公司不能按甲方及招标文件要求的工期内完成本工程,本公司愿按招标文件的条约负违约责任。第三节雨季施工工作支配1雨季施工措施1.1基本要求1.1.1雨季期间的土方工程的施工,必需坚持集中力气分段突击的原则,完成一段再开一段,绝不允许在全线进行大挖大填。雨季期间,在开挖工作面和工作场地均随时保持肯定的坡度,以利刚好排走雨水,便于雨后即时复工。硷浇捣期间随时留意气象台预报,尽量避开雨天施工砼。如遇雨,留意雨后砂石含水量的改变,并刚好调整硷协作比,现场备足雨布,以防雨天浇筑过程中砼被冲刷。1,1.6防水工程应避开在雨天进行施工。现场机电设备要做好防雨、防雷、防漏电措施。下雨由项目经理领导组织现场沟槽排水,临时排水专项紧急领导小组充丝挥其智能指挥工人团结奋斗。1.2雨季施工保证体系依据总体施工进度支配支配,依据以上项目编制有针对性的雨期施工方案。为保证工期,雨期施工以预防为主,采纳防卫措施及加强排水手段,适时调整工序施工确保雨期正常的施工生产。现场成立以项目经理为首的雨期施工领导小组,负责组织实施雨期施工的各项质量保证措施,首先全面调查施工现场的地势,调查自然排水系统及原有的排水管道等泄水实力,以便探讨制定汛期排水方案,然后依据以上调查状况细致编制雨期施工方案,报监理工程师审批后组织施工人员学习,确保每个工序按标准、规范、规程和技术措施组织施工。设专人值班接收天气预报,刚好了解天气状况,做好防范工作。与当地政府有关部门亲密联系,疏通现有排水系统,保证排水通畅。1.3雨期施工打算1.3.施工现场四周保持排水通畅,不积水,防止四邻地区地面水倒流。在选择施工临时设施位置时,要留意四周地形,做好施工现场排水工作,避开因连阴雨或暴雨沉没施工材料。雨期之前要对施工现场的全部设备进行全面检测电气设备要有平安牢靠的防雨设施并挂合格证,雨后必需对电气设备进行绝缘电阻遥测,合格后粘贴合格证再允许投入运用。工程施工所设置的排架、模板、支护、临时便桥、悬吊、加固等设置都必需经加强。刚度、稳定性计算后,方可施工,设施完成后,必需经项目总工程师组织有关部门检查合格后方可投入运用,雨后须要对上述设施进行全面检查、无问题后方可投入运用,特殊是要再确认无倾斜、无下沉、无松土、无塌陷等现象后方准接着运用。第八章关键施工技术、工艺及工程项目实施的重点、难点和解决方案第一节施工打算1、临时设施、场地布置依据对现场的考察,施工现场办公室及有关宿舍设施搭设在施工现场旁边的空地,详见施工总平面布置图,其中包括临时性生产,生活设施,材料及构件堆放场地,水电供应,临时道路,大中型施工机械设备及其他临时设施的布置等。签订合同后,马上组织人力进行施工打算,如“三通一平“等,为正式施工作好充分打算。a,节约临时设施用地,尽可能利用现场原有建筑物,削减临时搭建:b、开工前,应做好场地清理工作,以利工程进展,施工场地应充分考虑防水及积水解除。c、整个施工路段应合理划分,针对现场状况,做到便利施工,节约运输和装卸时间和费用:力求分批来料,缩短运距,尽量避开场内重复运输,大型或笨重机械、材料、构件应尽可能放在运用地点,就近运转利用。d,施工场地布置时,对易燃、易爆等危急品的存放地点应符合平安和消防的有关规定和要求;依据现场施工,运输要求,合理布置I高时道路。2、图纸会审、技术交成:在工程开工之前,公司组织工程科及项目部的工程技术人员和施工人员细致审查图纸,记录提出的问题及解决方法,并组织两级技术交底,第一级由公司经理组织技术人员向项目经理交底,其次级项目经理向操作层班组次底。3、施工部署:本工程支配工期为70个日历天,工程量大工期紧,依据实际状况,在.有条件并不影响旁边环境的状况下尽可能加班加点开工,各专业工序在不影响工程质量和平安的状况下,必需交叉作业。4,测量及试验支配a、测量组人员在开工前细致阅读有关图纸,汇总数据,明确了解施工依次,做好施工测量支配。b、试验组人员了解工程中试验的项目内容,整理试验仪器,做好各种原材料的抽样、检验和硷协作比设计。其次节土石方工程土方开挖时采纳勾机进行开挖,并结合人工开挖以挖出设计要求的工作面,开挖出的土方用自卸汽车运到指定地点。因为本工程实行先桩施工后开挖的方案,在机械开挖时要留意成桩四周挖土时造成的荷载改变,简洁造成桩偏位因此桩旁边土方应四周同时开挖,开挖时不能一次到位,要分层挖土。为了防止地下水影响边坡塌方,施工时设置排水系统将地下水解除到基坑处,以保证基坑无积水。土方回填采纳人工回填,回填时应分层回填,层厚在30-50cm之间;每层土须要用蛙式打夯机夯实后再能回填紧后一层土,以保证回填压实度达到设计要求避开因回填质量不好所引起的过大沉陷。第三节桩基础工程一、桩基础工程施工技术及工艺:1、基础施工主要执行规范:(a)国家标准《建筑桩基础技术规范》;(b)《建筑地基处理技术规范》。2、打桩施工:施工打算:先将桩基施工场地开挖平整,保证桩基施工设备(桩机、吊机、汽车等)进入施工现场能正常施工。测量定位:由专业技术人员按规范要求进行。经监理校核确认无误后,方可进行下道工序施工;桩机就位:测定桩位后,进行桩机就位,打桩时不得产生位移或沉降,否则应予重新校正加固。吊桩定位:留意保持平衡,并使桩精确定位。锤击贯入:打桩过程中,出现桩沉入异样现象时,现场技术人员应刚好比照地质资料进行分析、探讨、推断,推断不清时,应会同设计人员进行协商解决。第四节混凝土及钢筋混凝土工程一、钢筋混凝土工程施工技术及工艺钢筋工程现场设钢筋加工场,钢筋全部于现场加工,由于本工程运用钢筋的品种较多,所以从钢筋原材到半成品都必需做好标识,并分区分堆放。钢筋制作、安装的质量将干脆影响到硅结构的耐久性,钢筋制安必需遵照施工规范规定。按图纸要求制安钢筋,做到钢号·直径、形态、尺寸、数量均满足{要求;焊接接头符合施工规范要求;钢筋爱护层符合设计要求。钢筋工程质量管理程序:技术交底→钢筋加工→半成品验收→钢筋安装→班组自检→施工检查→质检、监理、设计验收→下道工序。购买钢筋时应检查出厂合格证,钢筋进场后马上对钢筋送质监站抽样检验,合格后方可运用。钢筋加工前对钢筋进行除锈和调直处理。钢筋严格按设计图标明的尺寸以及规范允许的偏差进行加工成型。4.2.1(1)核对半成品钢筋的钢号、直径、形态、尺寸和数量等是否与料单料}牌相符。如有错漏,应订正增补。(2)打算绑扎铁丝及绑扎工具,搭设操作架。钢筋绑扎的铁丝采纳20-22号铁丝,其中22号铁丝只用于绑扎直径12㎜以下的钢筋。(3)打算限制混凝土爱护层用的水泥砂浆垫块。水泥砂浆的厚度应等于爱护层的厚度,垫块尺寸当爱护层厚度等于或.小于20㎜时为30㎜X30㎜,大于20㎜时为50㎜X50㎜(4)钢筋的加工及绑扎应符合设计及《混凝土工程施工及验收规范》(GB50204-92)的要求。.2墙筋绑扎(1)为保证墙体钢筋在混凝土浇筑时不产生移位,每层拟设置至少两道用db8钢筋焊制的墙筋定位架,用于墙体两层钢筋间相对位置的定位及单根钢筋的定位。一道定位架设在顶板之下,另一道设在设在顶板之上。(2)墙筋钢筋垫块采纳水泥砂浆垫块,呈梅花形布置,纵横间距不超过lm。.3柱筋绑扎(1)箍筋的接头(弯钩叠合处)应交织布置在四角纵向钢筋上:箍筋转角与纵向钢筋交叉点均应扎牢(箍筋平直部分与纵向钢筋交叉点可间隔扎牢),绑扎箍筋时绑步口相互间应成八字形。(2)框架梁钢筋应放在柱的纵向钢筋内侧。(3)每层柱筋也应至少设置两道定位支架,定位支架用钢筋焊制,一道在顶板之下,一道在顶板之上。(4)柱筋垫块采纳水泥砂浆垫块,水平及竖向间距均不超过lm。4.2,.1.4梁与板钢筋绑扎(1)纵向受力钢筋采纳双层排列时,两排钢筋之间应垫以直径>,25mm的短钢筋,以保持其设计距离。(2)箍筋的接头(弯钩叠合处)应交织布置在两架立钢筋上,其余同柱。(3)板上部的负筋,要防止被踩下;特殊是雨篷、挑檐等悬挑板,要严格限制负筋位置。具体措施是焊设专用钢筋马凳以支撑楼板上层钢筋:马凳的间距要足以支撑顶板钢筋及施工荷载,马凳的支腿不得接触模板,要垫设混凝土垫块。(4)板、次梁与主梁交叉处,板的钢筋在上,次梁的钢筋居中,主梁的钢筋在下。(5)框架节点处钢筋穿插特别稠密时,应特殊留意梁顶面主筋间的净距要有30mm,以利浇筑混凝土。(6)梁钢筋的绑扎与模板安装之间的协作关系:①梁的高度较小时,梁的钢筋架空在梁顶上绑扎,然后再落位;②梁的高度较大(≥1.2m)时,梁的钢筋宜在梁底模上绑扎,其两侧模或一侧模后装。(7)梁板钢筋绑扎时应防止水电管线将钢筋抬起或压下。(8)砖墙拉接筋伸出部分先予埋150mm短钢筋,在模板钻孔后穿出,砖墙砌筑之前将其其余部分用单面焊接长。模板工程模板工程是硅施工中的一个重要的组成部分。模板安装的质量,干脆影响硅结构的尺寸、防裂功能。所以必需对模板安装进行细致的设计、施工。使模板及其支撑体系做到:保证工程结构和构件各部份形态尺寸和相互位置正确:具有足够的强度、刚度和稳定性;能牢靠地承受新浇筑混凝土的重量和侧压力,以及在施工产生荷载。构造简洁、装拆便利,并便于钢筋的绑扎和混凝土的浇筑及养护等工艺要求;模板接缝严密、且表面光滑。模板工程质量管理程序:技术交底→测量放样→安装模板及支撑→班级自检→施工员检查→测量组检测→质检员检查→监理验收→下道工序。.1柱模b.柱模的安装程序柱筋绑扎→定位放线→操作架搭设→模板位置水泥砂浆找平→柱模板就位→柱箍、拉杆及压脚安装→位置调校→支撑加固。c.柱模的运用材料及要求模板采纳18㎜厚夹板配置,竖向背楞采纳50X100木方,,间距不超过350㎜。柱箍采纳槽钢,截面边长尺寸大于lm的柱子采纳12号槽钢、M12高强螺杆(配套蝶形螺母)及一100×100×10垫片做为其柱箍,截面边长尺寸在lm之内的柱子采纳10号槽钢、M12高强螺杆做为其柱箍,柱箍间距不超过500㎜,第一道柱箍距根部为200㎜。圆形柱模板在木工车间定型制作,肋形模板采纳18mm厚胶合板,按柱直径在其上开半圆形孔,竖向布置,间距不超过350,在肋形模板上竖向钉5CM宽木条拼成圆柱模,在肋形模板平面上钉50X100木仿夹紧木条。竖向背楞50X100木方,间距不超过350mm。柱箍采纳10号槽钢、M12高强螺杆,柱箍间距不超过500mm,第一道柱箍距根部为200mm。d.柱模的安装方法柱模安装之前,先要放出柱子边线及300限制线,合模之前,柱子区域内的杂质应彻底清理。柱子根部模板位置用水泥砂浆找平,应留意找平砂浆不得吃入柱身内;待砂浆有强度后在模板位置粘设海绵条,以防止柱模根部漏浆。在施工底板或顶板时,在墙体两,。距柱边约300mm处埋设Φ25钢筋桩,每边不少于两根,用于柱模根部的固定。每根柱子的模板均分四块配置,其中相对的两块制作时要将柱箍钉设在其内背楞上,而另两侧模板加工时只钉内背楞,柱箍后安装。将柱模吊装就位,调整方正垂直、然后安装柱箍。.2墙体模板a.墙体模板采纳散装散拆的施工方法,在施工过程中,墙体的根部要适当留清扫口,用以清理墙体内的木屑和混凝土渣子等。内背楞和外背楞肯定按规定的间距匀称布设,墙体的支撑结构肯定要有足够的强度和稳定性,防止浇注混凝土时,发生涨模和走模现象。b.墙模板的安装程序气墙钢筋绑扎及梁板支撑架操作架搭设→定位放线→墙根部水泥砂浆找平及海绵条粘贴→一侧墙模板安装及调整→穿对拉螺杆→墙另一侧模板安装→调整验收。C.墙模的运用材料及要求模板采纳18厚光面胶合板,竖向背楞50X100木仿,间距不大于350㎜,外背楞10号槽钢(双根),水平匀称布置,间距不超过700㎜。M12穿墙高强螺杆匀称布置,水平间距不超过800㎜,距边不超过200㎜,钢板垫片规格为=l00x100x10。穿墙螺杆外套硬质PVC管,套管两端设塑料胶杯,模板拆除后,螺杆取出重复运用。d.墙模板的安装方法(1)墙模安装之前,先要进行墙体定位放线,放出墙体边线及300限制线,并将墙体开孔位置放设在楼板上,用红油漆做出明显标记。墙体区域内的杂质应予以彻底清理。(2)墙体根部用水泥砂浆找平,应留意找平砂浆不得吃入墙身内;待砂浆有强度后在模板位置粘设海绵条,以防止墙体根部漏浆。③在施工楼板时,在墙体两侧距墙约300㎜处埋设中25钢筋桩,钢筋桩间距不超过800㎜,用于墙模根部的固定。(4)先安设一侧墙体的模板,初步校正并固定后再穿设穿墙螺杆,安装另一侧模板。(5)墙体开孔模板的侧边(与墙体模板的交接面)粘贴海绵条,以防止该部位的漏浆。模板拼缝处,模板与混凝土接触面处要粘贴海绵条,以防止漏浆。.3梁板模板a、梁板模板采纳18厚胶合板现场散装散拆的施工方法,但肯定要保证混凝土成型截面尺寸精确。b、柱拆模→梁位置限制线、标高限制点的设置→搭设梁板支撑架→梁底模铺设→梁侧模及板模铺设。c、梁板模板的运用材料及要求梁模板采纳18厚光面胶合板,背楞采纳50X100木仿,匀称布置,梁侧模间距不超过350㎜,梁底模木仿间距不超过250㎜.支撑系统采纳钢管脚手架,梁两侧脚手架立杆间距为板模支撑的间距,梁底的钢管间距为两侧脚手架立杆间距的二分之一,支撑顶部设置可调顶托,其上放置钢管作为纵向围拎。梁高在700㎜以内时,梁侧设斜向支撑,梁高在700㎜以上时,梁侧设横向高强拉杆,纵向间距800㎜,沿梁高方向每增加500㎜,增设一道横向高强拉杆。楼板模板采纳18厚光面胶合板,搁栅采纳50X100木仿,匀称布置,间距不超过350㎜,支撑系统采纳钢管脚手架,脚手架立杆纵横间距均不大于1200㎜,脚手架支撑顶部设置可调顶托,其上放置木仿100X100㎜,作为搁栅承重龙骨。当楼面层超群过4.5m时,梁板模板为高支模支架,其模板支撑搭设d.梁模安装方法(1)梁底模板:按设计标高调整支柱的标高,然后安装梁底模板,并拉线找平。当梁底跨度大于及等于4m时,跨中梁底处应起拱,起拱高度为梁跨度的0.15%0主次梁交接时,先主梁起拱,后次梁起拱。②梁侧模板:依据墨线安装梁侧模板、压脚板、斜撑等。梁侧模板制作高度应依据梁高及楼板模板压旁来确定。③梁、板、柱、墙交接位置的模板应细致加工及拼装,必要时现场测量精确的尺寸,由车间加工制作。模板与已浇混凝土的接触面要粘贴海绵条,模板的拼缝也应设置海绵条,以防止漏浆。在拆除墙柱模板时,墙柱顶部埋设的拉杆留意爱护,用于墙柱友梁板交接处模板的固定。e.板模板安装方法如下:(1)依据模板安装原则,确定支撑间距。(2)依据模板排列图架设支柱和龙骨。(3)通线调整支柱的高度,将大龙骨找平,架设小龙骨。(4)铺模板时可从四周铺起,在中间收口。若为压旁时,角位模板应通线钉固。(5)楼面模板铺完后,应细致检查支架是否坚固,模板梁面、板面应清扫干净。板模的拼缝应用腻子刮平式,粘贴胶纸,板模与梁模的拼缝均应设置海绵条,以防止漏浆。(6)板跨度大于及等于4m时,模板应按设计要求起拱;如无设计要求,起拱高度宜为全长跨度的0.15%..4模板拆除依据《混凝土结构工程施工及验收规范》(GB50204-92)的要求,模板的拆除应满足下列条件:(1)在混凝土强度保证其表面及棱角不因拆除模板而受损后方可拆除,通常状况卞墙柱混凝土浇筑之后至少24小时方可拆除其模板。(2)底模拆除条件见下表:现浇结构拆模时所需混凝土强度结构类型结构跨度(m)按设计的混凝凝土强度标准值的百分率计(%)板≤250>2.≤875>8100梁≤875>8100悬臂构件≤275>2100(3)若要在混凝土浇筑28天之内拆模,则必需留置多余的混凝土试块,拆模前试压。(4)已拆除模板及其支架的结构,应在混凝土达到设计强度后,才允许几承受全部荷载,施工中不得超载运用,严禁堆放过量建筑材料,当承受施工荷载大于计算荷载时,必需经过核算加设临时支撑。混凝土工程砼施工干脆影响主体结构尺寸以及防裂的效果。因此,必需用机械化联合作业,合理支配施工组织,细致细致地做好硅浇筑前的打算工作,才能确保施工质量。.1混凝土浇筑的一般要求(1)浇筑竖向结构混凝土时,如浇筑高度超过2m时,应采纳柔性导管、溜槽入模。(2)浇筑混凝土时分段分层进行,每层浇筑高度应依据结构特点、钢筋疏密确定。一般分层高度为插入式振动器作用部分长度的1.25倍,最大不超过500㎜。平板振动器的分层厚度为200㎜。(3)运用插入式振动器快插慢拔,插点要匀称排列,逐点移动,按依次进行,不得遗漏,做到匀称振实。移动间距不大于振动棒作用半径的1.5倍(一般为300-400㎜)。振捣上一层时插入下层混凝土面50㎜,以消退两层间的接缝。平板振动器的移动间距能保证振动器的平板覆盖已振实部分边缘。(4)浇筑混凝土连续进行。如必需间歇,时间尽量缩短,并在前层馒凝.土初凝之前,将次层混凝土浇筑完毕。间歇的最长时间按所用水泥品种及混凝土初凝条件确定,混凝土初凝后按施工缝处理。(5)浇筑混凝土时派专人常常视察模板钢筋、预留孔洞、预埋件、插筋等有无位移变形或堵塞状况,发觉问题马上停止浇灌并在已浇筑的混凝土初凝前修整完毕。(6)振动棒要尽量避开与钢筋及模板接触,尤其是避开与埋件接触。.2墙柱混凝土浇筑(1)墙、柱浇筑前,或新浇混凝土与下层混凝土结合处,在底面上的浮浆剔除干净,并用水冲洗。。(2)墙、柱混凝土分层浇筑振捣,每层浇筑厚度限制在500mm左右。墙体混凝土连续浇筑。(3)柱子混凝土浇筑速度要限制在5m/h之内,柱子四角及柱子中部都要予以振捣。.3梁板混凝土浇筑先浇筑墙柱混凝土,后浇注梁板棍凝土。混凝土浇筑时,要用钢筋马凳、脚手架板在顶板上搭设马道,人员尽量站在马道上操作,以避开踩踏顶板钢筋。(1)梁板同时浇筑,浇筑方法应由一端起先用“赶浆法”推动,先将梁分层浇筑成阶梯形,当达到楼板位置时再与板的混凝土一起浇筑。(2)楼板浇筑的虚铺厚度应略大于板厚,用平板振动器垂直浇筑方一直回振捣。留意不断用移动标记以限制混凝土板厚度。振捣完毕,用刮尺或拖板抹平表面,初凝之前,用木抹子将混凝土表面反复搓压数道。(3)施工缝设置:宜沿着次梁方向浇筑楼板,施工缝留置在次梁跨度1/3范围内,施工缝表面与梁轴线或板面垂直。单向板的施工缝设置在平行于板的短边的任何位置。(4)施工缝处待己浇混凝土的抗压强度不少于1.2Mpa时,才允许接着浇筑。(5)在施工缝处接着浇筑混凝土前,混凝土施工缝表面应凿毛,清除水泥薄膜和松动石子,并用水冲洗干净。解除积水后,先浇一层水泥浆或与混凝土成分相同的水泥砂浆然后接着浇筑混凝土。(7)混凝土终凝之后,即可支配清理粘接在柱筋上的水泥浆,并将柱内混凝土凿毛。.4楼梯混凝土浇筑(1)楼梯段混凝土自下向上浇筑。先振实底板混凝土,达到踏步位置与踏步混凝土一起浇筑,不断连续向上推动,并随时用木抹子将踏步上表面抹平。(2)楼梯混凝土连续浇筑完成。(3)施工缝位置:依据结构状况可留设于楼梯间平台板跨中或楼梯段1/3范围内。(4)楼梯踏步棱角设置中10钢筋对其进行爱护。.5钢筋、模板、埋设件检查混凝土浇筑期间,要支配专人对钢筋、模板及埋设件进行检查,若遇、钢筋埋件移位等状况等要刚好处理。外露钢筋在混凝土浇筑后刚好用钢丝刷将粘在钢筋上的混凝土清理干净施工缝处在混凝土浇筑完毕后要刚好划毛。.6混凝土的养护(1)梁板混凝土混凝土浇筑完毕后,12h以内浇水养护,并保持混凝土表面潮湿。(2)柱子拆模后,采纳包袱塑料膜养护,包袱严实,以防止水份蒸发,须要时,浇水养护,保持饱和潮湿状态。(3)墙体拆模后,洒水养护。(4)混凝土浇水养护时间不少于7d,实行洒水养护的方式,支配专人进行该项工作,使混凝土面始终保持潮湿状态。(5)每日浇水次数应能保持混凝土处于足够的润滑状态。.7预防渗漏,开裂的技术措施1)外墙固定模板用的螺杆管道两端进行防水抹灰处理。2)混凝土运输后出现离析应二次搅拌,浇灌高度超过2米的应设串筒、溜槽下料,混凝土应分段、分层匀称连续浇灌,并用机械振捣密实。3)浇灌混凝土留设施工缝时,依据施工规范要求处理。4}大体积混凝土梁实行分层浇注、降低浇灌温度、加快散热等措施,以防止产生温度收缩裂缝。5)掺加掺合料一在混凝土中掺加粉煤灰,削减水泥用量,降低水泥水化热,削减绝热条件下的温度上升。6)掺加减水剂,降低水泥用量,降低水化热,推迟放热峰出现的时间因而削减裂缝。.8预拌混凝土的质量限制1)混凝土供应商的评审工作特别重要,选择一家资质和信誉好的供应商是保证混凝土质量的关键。2)原材料的检验限制,对混凝土供应商搅拌站的原材料进行监督检验,预拌混凝土生产企业必需选用获得市主管部门颁发《核准证书》的外加剂和大型旋窑散装水泥,禁止运用立窑水泥、小型旋窑水泥和袋装水泥。3)生产质量限制,试验室要派技术人员在搅拌楼值班,要求操作员严格按试验室供应的协作比生产,对每车混凝土都要求目测其坍落度,增加对混凝土坍落度的检测次数和砂、石含水率的测试次数。4)运输,严禁运输车司机在运输过程中加水,限制混凝土运输车运输时间不超过1小时,到达现场交施工方验收合格后才能卸料,卸料时混凝土运输车先快速搅拌1飞分钟。混凝土车在接受装料前须将拌筒内的余水倒干净。5)每批混凝土供货前,供方须供应符合国家标准的混凝土协作比报告、试验报告、协作比材料试验报告,外加剂、掺合料试验报告及材质证明各一份。6)施工单位在有监理人员见证的条件下,派技术人员到工地现场取样,混凝土供应商派也应派技术人员参与协作抽样工作。7)混凝土供应商必需负责保证商品混凝土运抵现场时的坍落度和其它标准符合质量要求,若商品混凝土在运输过程和到达施工现场时发觉坍落度和其他标准达不到设计标准时,拒绝接收。8)混凝土供应商的发货单要由操作室人员签发,并精确填写车号、混凝土标号、数量和签发时间。9)供应商品混凝土时,供应商供应书面技术交底报告,注明在现场接收、泵送、浇筑和养护的留意事项,并有技术人员到混凝土浇筑现场进行指导。10)工地现场交货检验的结果.,做为混凝土质量评定的依据。第五节砌筑工程一、砌筑工程施工技术及工艺:本工程砖墙运用标准砖,水泥石灰混合砂浆M5砌筑。砌体材料强度等级必需符合设计要求,进入现场必需有出厂合格证及试验单;水泥采纳32.5R一般硅酸盐水泥,进入现场必需有出厂合格及试验单。砂采纳中砂,不得含有草根等杂物,砂的含泥量不得大于5%.石灰膏熟化时间不得少于7天,严禁运用脱水硬化的石灰膏。墙体砌筑严格依据施工规程及设计要求施工,做好技术交底,砌体用砖必需提前一天浇水潮湿,严禁干砖上墙,以削减砌筑粉刷时水泥砂浆(或混合砂浆)中水分的损失,确保砌筑及粉刷质量。砌筑砂浆采纳重量协作比,计量要精确,试块按规定留取,隔库砂,浆不得运用。1、施工打算按标高抹好水泥砂浆防潮层。弹好墙身线、轴线,依据现场砖的实际尺寸,再弹出窗洞口位置线,经检验线符合设计图纸的尺寸要求,办完预检手续。按标高立好皮数杆,皮熬杆的间距为15-20m为宜,并办好预检手续。砂浆由试验室做好试配,打算好试模,6块为一组。2,砌体施工工艺:砌筑砖墙通常有抄平、放线、摆砖样、立皮数杆、立头角和勾缝等工序:(1)、抄平:砌砖前,在基础防潮层或楼面上定出各层标高,并用水泥砂浆抄平。(2)、放线:在抄平的墙基上,按龙门板上轴线定位钉为准拉麻线,弹出墙身中心轴线,并定出门窗洞口位置;(3)、摆砖样:在弹好线的基面上,由阅历丰富的瓦工,依据墙身长度(按门、窗洞口分段)和组砌方式进行摆砖样,使每层砖的砖块排列和灰缝宽度匀称;(4)、立皮数杆:皮数杆是一根限制每皮砖砌筑的竖向尺寸,并使铺灰、砌砖的厚度匀称,保证砖皮水平的一根长约2M左右的木板条。上面标有砖的皮数、门窗洞、过梁、楼板的位置,用来限制墙体各部分构件的标高。皮数杆立于墙的转角处,用水准仪校正标高,如墙很长,可每隔10-12M再立一根。(5)、立头角:盘角时,主要大角盘角不要超过5皮砖,应随砌随盘,然后将麻线挂在墙身上(称为挂准线);盘角时还要和皮数杆比照,检查无误后才能挂线,再砌中间墙。(6)、勾缝:勾缝宜用1:1:5的水泥沙浆,砂应用细砂,也可用原浆勾缝。(7)、木砖预留孔洞和墙体拉结筋:木砖预埋时小头在外,大头在内,数量按洞口高确定,洞口高在1.2m以内,每边放2块,高1.2-2m每边放3块,高在2-3m每边放4块。墙体抗震拉结筋的位置,钢筋规格,数量,间距均应按设计要求留置。(8)、构造柱做法:在砌筑之前,先依据设计图纸要求,将构造柱位置进行弹线,并把构造柱插筋处理顺直。砌砖墙时与构造柱联结处砌成马牙搓,每一马搓沿高度方向的尺寸不宜超过30cm,(即五皮砖),砖墙与构造柱之间应沿墙高度每50cm设置2(D6水平拉结钢筋联系,每边伸入墙内不应少于lm.3、质量要求砌筑质量符合吸砖石工程施工及验收规范)(GBJ203-83)的要求。做到“横平竖直、砂浆饱满、组砌得当、接搓可造”。(1)、水平灰缝应平直、竖向灰缝应垂直对齐,不得游丁走缝,(2)、的砂浆饱满度不得小于8%(可用百格网检查)。这样可保证砖匀称受压,避开受弯、受剪和局部受压状态的出现。(3)、为提高砌体的整体性、稳定性和承载力,砖块排列应遵守上下错缝的原则,避开垂直通缝出现,错缝或搭砌长度一般不小于60㎜。为满足错缝要求,实心墙体组砌时,采纳一顺一丁、三顺一丁和梅花丁(同一皮中丁砖与顺砖相间排列)的砌筑形式。砌筑方法采纳“三一”砌法,即用大铲一铲灰、一块砖、一挤揉的砌筑方法。(4)、接搓牢靠:砖砌体的转角处和交接外应同时砌筑,对不能同时砌筑而又必需留置的临时间断处,应砌成斜搓,且实心砖砌体的斜搓长度不应小于高度的2/3;如临时间断处留斜搓有困难时,除转角处外,也可留直搓,但必需做成阳搓,并加设拉结筋;拉结筋的数量为第12cm墙厚放置一根。6的钢筋,间距沿墙高不得超过50cm,埋入长度从墙的留搓处算起,每边不应小于50一cm,未端应有90。弯钩;墙砌体接搓时,必需将接搓处的表面清理干净,浇水潮湿,并应填实砂浆,保持灰缝平直。第六节门窗工程本工程门窗工程包括铝合金玻璃窗、夹板门等。一、铝合金门窗安装1、铝合金窗施工工艺流程:窗框上下边划中线一固定片安装一测各窗口中线一窗框装入洞口一窗与墙体固定一嵌缝一安装玻璃④安装五金件。2、铝合金门窗框安装施工工艺:(1)上下边划中线:将不同规格的铝合金门窗搬到相应的洞口竖放,当发觉爱护脱落时,应补贴爱护模,并在门窗框的上下边划出中线。(2)应在检查窗框上下边的位置及其内外朝向,并确认无误后,再安装固定片。安装时应先采纳直径(D3.2的钻头钻孔,然后将十字槽盘头自攻螺钉M4X20拧入,并不得干脆锤击钉入。固定片的位置应距窗角、中竖框、中横框150-200mm,固定片之间的间距应小于mmo不得将固定片干脆装在中竖框、中横框的档头上。(3)测各窗口中线:测出各窗口上下边的中线,并逐一作出标记。多层建筑,可以从高层一次垂吊。(4)窗框装入洞口:将窗上下框中线与洞口中线对齐,在窗的上下框四角及中横框的对称位置先用木楔或垫块塞紧作临时固定(当下框长度大于900mm时,其中心应增加木楔或垫块),然后应按设计图纸确定窗框在洞口墙体厚度方向的安装位置,并调整窗框的垂直度、水平度及直角度。3、窗与墙体固定:(1)应先固定上框,后固定边框。混凝土墙洞口应采纳射钉或塑料膨胀螺钉固定;砖墙洞口应采纳塑料膨胀螺钉或水泥钉固定,并不得固定在砖缝处;加气混凝土洞口,应采纳木螺钉将固定片固定在胶粘圆木上;下框与墙体的固定,采纳将固定片用水泥砂浆或细石混凝土浇筑固定。(2)安装组合窗时,拼幢料与砖墙洞口的连接,应将拼幢料两端插入预留洞中,然后用C20细石混凝土浇灌固定;拼模料与混凝土过梁或柱子的连接,应采纳在预埋铁件上焊接或打基孔用紧固件连接固定。应将两窗框与拼模卡接,卡接后应用紧固件双向拧紧,其间距应不大于600m,紧固件端头及拼橙料与窗框间的缝隙应采纳嵌缝膏进行密封处理。4、嵌缝:(1)窗框与洞口之间的伸缩缝内腔应采纳闭孔泡沫塑料、发泡聚苯乙烯等弹性材料分层填塞,填塞不宜过紧。对于保温、隔声等级要求较高的工程,应休用相应隔热、隔声材料填塞。填塞后,撤掉临时固定用木楔或垫块,其空隙也应采纳闭孔弹性材料填塞。(2)一般单玻窗窗框与洞口内外侧之间缝隙的处理,其洞口内外侧与窗框之间应采纳水泥砂浆或麻刀白灰浆填实抹平,靠近铰链一侧,灰浆压住窗框的厚度宜以不影响扇的开启为限,待水泥砂浆硬化后,其外侧应采纳嵌缝膏进行密封处理。(3)保温、隔声窗窗框与洞口内外侧之间缝隙的处理,应用水泥砂浆填实抹平;外侧抹灰时,应采纳片材将抹灰层与窗框临时隔开,其厚度宜为5mm,抹灰面应超出窗框,其厚度以不影响扇的开启为限。待抹灰层硬化后,撤去片材,并将嵌缝膏挤入抹灰层与窗框缝隙内。保温、隔声等级要求较高的工程,洞口内侧与窗框之间也应采纳嵌缝膏密封。5、安装玻璃:(1)玻璃不得与玻璃槽干脆接触,应在玻璃四边垫上不同厚度的玻璃垫块,垫块与边框应采纳防水硅胶固定。(2)将玻璃装入框扇内,然后用玻璃压条将其固定。(3)安装双层玻璃时,玻璃夹层四周应嵌入中隔条,中隔条应保持密封、不变形、不接脱落;玻璃槽及玻璃内表面应干燥、清洁。(4)镀膜玻璃应装在玻璃的最外层,单面镀膜层应朝向室内。二、夹板门安装:1、工艺流程:划中线一安装固定片~门框安装~嵌缝一门扇安装一五金配件安装。2、划中线:将门搬到相应洞口旁竖放,在门框及洞口上划出垂直中线。3、在门的上框及边框上安装固定片,安装方法参见第2条。固定片之间的间距应不大于600㎜。4、装入洞口,安装时应实行防止门框变形的措施。无下框平开门侧框下脚应低于地面标高线25-30㎜,带下框平开门及推拉门下框应低于地面标高线10-15㎜整门框水平度、垂直度和直角度,并用木楔临时定位,再将其余固定片固定在墙上。安装连窗门时,门与窗应用拼模拼接,拼幢料下端应固定在窗台上。安装固定方法参见第“窗与墙体固定”。5、嵌缝:门框与门洞口缝隙的处理,按“嵌缝”的要求进行。6、门扇安装:门扇应待嵌缝水泥砂浆及地面水泥砂浆硬化后安装。7、五金配件安装:门锁与执手等五金配件应安装坚固,位置正确,开关敏捷。其它类型门参照夹板门安装方法进行施工。第七节湿装饰工程本工程湿装饰工程包括内墙面抹灰、天花抹灰、外墙贴瓷砖、楼地面铺地砖等。一、抹灰工程1.内墙面抹灰操作方法(1)清理基层:清理墙面上浮灰污物,检查门窗洞口位置尺寸,打凿补平墙面,浇水潮湿基层。(2)找好规则:四角规方,横线找平、立线吊直,弹出准线和墙裙、踢脚板线。先用托线板检查墙面平整垂直度,大致确定抹灰厚度,一般最薄处不小于7㎜:在距顶棚20㎜,做上灰饼。遇到门、窗垛角处要补做杰饼,灰饼大小5㎜见方,厚以墙面平整垂直确定,然后依据上灰饼用托线板或锤挂垂直做下灰饼,位置一般在踢脚线上口,厚度以垂直为准。再用钉子在左右灰饼旁边墙缝里,栓上小线挂好通线,并依据小线位置每隔1.2-1.5m上下加做若干灰饼,待灰饼稍干后,在上下灰饼之间抹上宽约1Omm的浆冲筋,用木杠刮平,厚度与灰饼相同,待稍干后进行底层抹灰。灰饼可用1:3水泥砂浆或打底砂浆抹制。(3)作护角在室内的门窗洞口及墙面、柱子的阳角处应做护角,可使阳角线条清晰,挺直、防止碰坏。一般运用水泥砂浆抹出,护角高度不应低于2M,每侧不小于50㎜,如图1-13所示。标筋应用1:2水泥砂浆抹制。(4)抹层底灰标筋有肯定强度后,洒水润湿墙面,然后在两筋之间用力抹上底灰,用木抹子压实搓毛。底层灰应略低于标筋,约为标筋厚度的2/3,由上往下抹。若基层为混凝土时,抹灰前应先刮素水泥浆一道,在加气混凝土或粉煤灰砌块基层抹石灰砂浆时,应先刷107胶溶液一道(107胶:水=1:5),抹混合砂浆时,应先刷107胶水泥浆一道,107胶掺量的质量分数为水泥重量的10%-15%。(5)抹中层灰中层灰应在底层灰干至6-7成后进行。抹灰厚度以垫平标筋为准,并使其稍高于标筋。抹上砂浆后,用木杠按标筋刮平,刮尺刮平后,紧接着用木抹子搓压,使表面平整密实。在墙角的阴角处,先用方尺上下核对方正(水平标筋侧免去此道工序),然后用阴角器上下拖动搓平,使室内四角方正。在加气混凝土基层上抹底灰的强度接近,中层灰协作比宜与底灰基本相同,底灰宜用粗砂,中层灰和面灰宜用中砂。板条或钢丝的缝隙中,各层分遍成活,每遍厚3-6㎜,待前一遍灰7-8成干再抹其次遍。钢丝网抹灰砂浆中掺用水泥时,其掺量应通过试验确定。(6)抹窗台后线、踢脚线窗台线应用1:3水泥砂浆抹层底,表面划毛,隔一天后,用素水泥浆刷一道,再用1:2.5水泥砂浆抹面层。面层要用原浆压光,上口做成小圆角,下口要求平直,不得有毛刺,浇水养护4天.踢脚线比墙面凸出3-5㎜,1:3水泥砂浆或水泥混合砂浆打底,1:2水泥砂浆抹面,依据高度尺寸弹出上线,把八字靠尺靠在线上用铁抹子切齐,修边清理。(7)抹面层灰操作应以阴角起先,最好两人同时操作,一人在前面上灰,另一人紧跟在后找平整,并用铁抹子压实赶光。阴阳角处用阴阳角抹子抨光,并用毛刷蘸水将门窗圆角等处清理干净。石灰砂浆面层应在中层砂浆5-6成干时进行。清理、抹灰工用完毕后,应将粘在门窗框、墙面的灰浆及落地灰刚好清除,打扫干净。天花抹灰前应将基层刷洗干净,用水充分潮湿并刷水泥浆(内掺5%的107胶)一道,在四周墙面上应弹出水平线,以水平线为依据,先抹顶棚四周,圈边找平。天花基层不平常,应分层批抹找平,每层厚度不得超过10㎜。与外墙相接的天花的抹灰应待外墙施工完成后施工,以便于限制滴水线的厚度各处一样。二.室内涂料墙面(l)基层表面的灰砂,污垢和油渍等,必需清除干净,脚手眼洞,门窗框与墙体之间的缝隙,应先用水泥砂浆堵实补好,混凝土基层应剔除凸出部分,光面要凿毛,用钢丝刷满刷一遍,或者洒水潮湿后用水泥浆加107胶水扫毛,增加粉刷粘结力。(2)基层处理后,应检查基层表面的平整度和垂直度,挂垂线拉水平通线,用与底层刮糙相同的砂浆做灰饼、出标筋,用长靠尺检查标筋是否标准。刮糙必需分层抹平,要求至少分两遍成活。局部超厚的应分层打底,用刮尺和木抹子按标筋抹平,并顺手划毛。表面要求平整、垂直、粗糙。对阴阳角和门窗头角要求方正、垂直、通顺。凡外墙遇砖与混凝土交界处,用防水砂浆打底后,铺一层钢板网再粉刷,防止裂缝的产生。(3)凡墙体阳角均做隐护墙角。采纳巧厚1:2.5水泥砂浆,每侧宽度不小于50,通顶高。做法为依据灰饼厚度抹灰,粘好八字靠尺,并且找方吊直,用1:2.5水泥砂浆分层抹平;待砂浆稍干后,用将角器和水泥浆捋出小圆角。(4)凡是卫生间墙体临房间墙面均采纳防水砂浆粉刷。全部粉刷面均要求阴阳角通角垂直,面层平整光滑,无明显接搓。(5)刮腻子:遍数可由墙面平整程度确定,一般为两遍,腻子以纤维素溶液、福粉,加少量107胶拌合而成。第一遍用抹灰钢光匙横向满刮,一刮板紧接着一刮板,接头不得留搓,每刮一刮板最终收头要干净平顺。干燥后磨砂纸,将浮腻子及斑迹磨平磨光,再将墙柱表面清扫干净。其次遍用抹灰钢光匙竖向满刮,所用材料及方法同第一遍腻子,干燥后用砂产并扫干净。(6)刷第一遍涂料在运用前要先用萝斗过滤。涂刷依次是先刷顶板后刷墙柱面,墙柱面是先上后下。运用新排笔时,将活动的排笔毛拔掉。涂料运用前应搅拌匀称,适当加稀释,防止头遍漆刷不开。涂刷时,从一头起先,逐惭向另一头推动,要上下顺刷,相互连接,后一排笔紧接前一排笔避开少现干燥后接头。待第一遍涂料干燥后,复补腻子,腻子干燥后用砂纸磨光,清扫干净。(7)刷其次遍涂料:其次遍操作要求同第一遍。运用前要充分搅拌,如不很稠,不宜加水或少加水,以防露底。(8)油漆要严格依据施工工艺要求进行施工。砂皮要打透,墙面做好后要求达到光明、平整、无透底、无漏刷现象发生。避开工程质量通病:(1)透底:产生缘由是涂层薄,因此刷涂料时留意不漏刷外,还应保持涂料的稠度,不行随意加水过多。有时磨砂纸时磨穿腻子也出现透底。(2)接搓明显:涂刷时要上下顺刷,后一排笔紧接前一排笔,若间隔时间稍长,就简洁看出接头,因此大大面积涂刷时,应配足人员,相互连接。(3)刷纹明显:涂料稠度要适中,排笔蘸漆量要适当,多理多顺防止刷纹过大。(4)刷分色线时,施工前细致划好粉线,用力匀称,起落要轻,排笔蘸漆量要适当,从上至下或从左至右刷。产品爱护:(1)墙柱表面的涂料末干前,室内不得清扫地面,以免尘土粘污墙柱面,干燥后也不得往墙柱面泼水,以免沾污。(2)墙柱表面涂刷涂料完成后,要妥当爱护,不得碰撞。(3)涂刷墙柱面时,不得沾污地面、门窗、玻璃等己完的工程。三、耐磨砖地面施工(1)铺贴前弹出+50cm标高水平墨线,各开间中心十字线及花样品种分格线。(2)地砖在进行铺贴的前一天应浸透、晾干备用。(3)依据水平线制作灰饼,用靠尺推出冲筋。(4)地基浇水潮湿后,刷水灰比为0.5的素水泥浆。(5)依据冲筋的厚度,用1:1:3水泥砂浆抹铺结合层。抹铺结合层应在基层保持潮湿且已刷水泥浆未风干时。(6)比照中心十字线在结合层面上弹出地砖限制线,靠墙的一行应与墙距离一样,限制线间距一般为每5块地砖一条。(7)4厚水泥膏结合层涂满地砖背面,对准挂线及缝子,将地砖铺贴上,用小木锤着力敲击至平正。水泥胶结合层按水泥:107胶:*=1:0.1:0.2的重量比配制。挤出的水泥胶要刚好清干净。(8)在粘贴地砖的水泥膏凝固后,用白水泥掺颜料调制成地砖色嵌缝,最终用锯末和棉丝将表面擦净。(9)在弹地砖限制线时尽量避开出现小半块乃至小于5cm的小镶条,凡有坡水要求的必需做好泛水找坡,不得产生积水现象。应使地漏位于地砖缝上,并在地漏周边呈米字形幅射切割地砖,歼灭坐水等质量通病。在穿楼板的管道处,做300高以上锥体,防止楼板渗漏。(10)卫生间等穿楼板管道安装完毕,必需补洞且阅历收无渗漏后才可铺贴地砖。采纳下部支撑或上部吊挂方式支模,凿毛洞口断面混凝土,清理套浆后分两次浇筑细石混凝土至比楼面低2-3cmo待混凝土初凝后,进行24h蓄水试验,无渗漏现象并经建设方验收合格方可进入下一道工序。(11)大面积施工时,应实行分段依次铺贴,按标准拉线镶贴,并随时做好各道工序的检查和复验工作,以保证铺贴质量。四、外墙砖墙面施工1、外墙砖铺贴(1)在清理干净的基层表面浇水湿透,抹底灰。抹底灰要吊垂直、找,规则、贴灰饼、冲筋,力求整体完备。(2)在干净的底灰上,依照室内标准水平线,找出地面标高,按贴砖的面积,计算纵横的皮数,用水平尺找平,并弹出瓷砖的水平和垂直限制线。(3)铺贴瓷砖时,应先贴若干块废瓷砖标记块,上下用托线板挂直,作为粘贴厚度的依据,横向每隔1.5m左右做一个标记块,用拉线或靠尺校正平整度。(4)按地面水平线嵌上一根靠尺,并用水平尺校正,做为第一行瓷砖铺贴依据。铺贴时,瓷砖下口坐在靠尺上,防止滑移并确保横平竖直。(5)贴瓷砖宜从阴阳角处起先,由下而上铺贴。铺贴要严格依据标记块限制其平整度。低于标记块的,应取下重新抹满刀灰再铺,不得在砖上处塞灰,否则会产生空鼓现象。在铺贴中,如有瓷砖规格尺寸或几何形态不等时应随时调整,墙裙最上口应成一条直线。(6)瓷砖铺贴排放应尽量保持镶边整块,否则也应在预排时计算好尺寸,尽量避开小半块或3-5cm镶小条的状况。(7)铺贴瓷砖应先贴大面,‘后贴阴阳角,凹槽等费工多、难度大的部位。’(8)铺贴完工后进行质量检查,用清水将瓷砖面擦洗净。接缝处用与瓷砖颜色相同的白水泥擦嵌密实。3、质量通病及防治措施:质量通病1拉缝不平直,缝宽不匀称缘由1、施工前对面砖挑拨不严格2、挂线、贴灰饼、排砖不规则防治措施1、细致选择面砖,剔出有缺陷的面砖。同一墙上应用同一尺寸面砖,以做到接缝匀称一样;2,粘贴前做好规婚用面砖贴灰饼,划出标准,阳角处要两面抹直;3、每贴好一行釉面砖,应刚好用靠尺板横、竖向靠直,偏差处用灰匙木柄轻轻敲平,刚好校正横、竖缝平直;质量通病2变色、泛黄、发花缘由1、面砖质地疏松,施工前浸泡不透防治措施1、选择质量好的品牌,施工中用干净水浸泡面砖,粘贴面砖的砂浆,应运用干净的原材料进行拌制,粘贴应密实,月砖缝应嵌塞严密,砖面应擦洗千净;质量通病3空鼓、脱落缘由1、基层没有处理好,墙面未潮湿,砂浆失水太快造成粘结力低,或浸泡的砖未晾干就粘贴。2、砂浆不饱满、厚薄不匀称,嵌缝不密实或漏嵌3、砂浆己经收水,再对粘贴完的面砖进行纠偏移动防治措施1、基层清理干净,表面修补平整,墙面洒水湿透。面砖使用前,必需用水浸泡不少于2h,取出晾干方可粘贴。2、面砖粘结砂浆过厚或过薄均易产生空鼓,厚度一般限制。在7-10二。必要时掺入水泥质量分数3%的107胶,提高粘结砂浆的和易性和保水性;粘贴面砖时用灰匙木柄轻轻敲击砖面,使其与底层粘结密实坚固,粘结不密实时,应取下重贴。3、当面砖墙面有空鼓和脱落时,应取下面砖,铲去原有粘{结砂浆,采纳‘07胶聚合物水泥砂浆粘贴修补。五.瓷砖墙面(1)在清理干净的基层表面浇水湿透,抹底灰。抹底灰要吊垂直、找规则、贴灰饼、冲筋,力求整体完备。(2)在干净的底灰上,依照室内标准水平线,找出地面标高,按贴砖的面积,计算纵横的皮数,用水平尺找平,并弹出瓷砖的水平和垂直限制线。(3)铺贴瓷砖时,应先贴若干块废瓷砖标记块,上下用托线板挂直,作为粘贴厚度的依据,横向每隔1.5m左右做一个标记块,用拉线或靠尺校正平整度。(4)按地面水平线嵌上一根靠尺,并用水平尺校正,做为第一行瓷砖铺贴依据。铺贴时,瓷砖下口坐在靠尺上,防止滑移并确保横平竖直。(5)贴瓷砖宜从阴阳角处起先,由下而上铺贴。铺贴要严格依据标记块限制其平整度。低于标记块的,应取下重新抹满刀灰再铺,不得在砖上处塞灰,否则会产生空鼓现象。在铺贴中,如有瓷砖规格尺寸或几何形态不等时应随时调整,墙裙最上口应成一条直线。(6)瓷砖铺贴排放应尽量保持镶边整块,否则也应在预排时计算好尺寸,尽量避开小半块或3-5cm镶小条的状况。(7)铺贴瓷砖应先贴大面,后贴阴阳角,凹槽等费工多、难度大的部位。(8)铺贴完工后进行质量检查,用清水将瓷砖面擦洗净。接缝处用与瓷砖颜色相同的白水泥擦嵌密实。第八节屋面及防水工程施工时按设计要求切实支配好施工工序,在施工屋面保温及防水工程时不得与其它工程交叉作业,在屋面保温防水工程完成后,应实行爱护措施。保温材料在施工时应保持干燥状态,其含水量不得大于当时气象条件下的自然含水量,防水卷材的施工在无雨的条件下进行,铺设卷材时凡阴角、阳角及形态改变处均应实行加层加固处理,特殊是在屋面防水与雨水口连接处,须细心施工,保证其密实无缝。预埋排水管在施工中应切实做好牢靠的爱护措施,确保混凝土及其它杂物跌入雨水管中。1,结构自防水依据对各种屋面防水工程施工阅历,屋面工程中应尽量确保现浇楼盖混凝土振捣密实,在屋面施工前对结构层进行养水48小时试验,如有渗水现象应在处理后再做屋面层,提高屋面结构的自防实力。2、水泥砂浆找平层施工2.1清理基层:将结构层上面松散杂物清除干净,凸出基层上的砂浆、灰渣用凿子凿去,扫净,用水冲洗干净。2.2冲筋:依据设计坡度要求拉线找坡、贴灰饼,顺排水方向冲筋,冲筋间距为1.5m左右,在排水沟处、雨水口处找出泛水,冲筋后即可进行抹找平层。2.3抹找平层:在铺砂浆前基层表面洒水潮湿,匀称扫素水泥浆一遍,随扫随铺水泥砂浆,用木杆沿两边冲筋标高刮平,木抹子搓揉、压实,砂浆稠度限制在7cm左右。2.4压实:砂浆铺抹稍千后,用铁抹子压实三遍成活,头遍得浆拉平,使砂浆匀称密实,当水泥砂浆起先凝聚,人踩上去有脚印但不下陷时,用铁抹子压其次遍,抖表面压平整、密实,留意不得漏压,并把死坑、死角、砂眼抹平,当水泥起先终凝时,进行第三次压实,将抹纹压平、压实,略呈毛面,使砂浆找平层更加密实,切忌在水泥终凝后压光。2.5养护:砂浆找平层抹平后,常温时24h后护草袋浇水养护,养护时间不少于7d,干燥后即可进行防水层施工。3,保温层3.1用木板按弹好的墨线装好分格板,并弹好厚度墨线。3.2按协作比用混凝土搅拌机拌制匀称,由远而近浇捣,并用平板震捣器震捣密实,防止珍宝岩颗粒上浮。3.3在捣灌过程中要用铁铲操作,避开珍宝岩颗粒与砂浆分层不匀称的现象,避开蜂窝、麻面。3.4在施工保温前将各开间纵横弹线留出排气槽,一般宽25㎜,并在二次找平常相应在十字交叉口留排气孔。在女儿墙及天沟角均做水泥砂小园角,天沟找坡严格近按图示要求施工,严禁结水。3.5屋面保温层施工时打算牢靠的防雨覆盖材料,严禁砂浆未做时雨水侵入保温层。4、细石混凝土层4.1工艺流程:处理、清理基层→绑扎钢筋→设置分格缝木条→浇筑细石混凝土→二次压光→覆盖养护→取出分格缝木条→清缝→嵌缝→铺贴板缝爱护层→清扫、检查和修补→验收。4.2绑扎钢筋网:为保证钢丝位置留置正确,采纳先在隔离层上满铺钢丝绑扎成型后,再按分格缝位置剪断并弯钩,放置钢筋网时不得损坏卷材防水层。4.3留置分格缝:分格缝木条做成上口宽20-40mm,下口宽20㎜,高度等于防水层厚度,木条涂刷隔离剂。4.4浇筑细石混凝土:细石混凝土所选用的水泥、水、骨料应符合现行规范中的规定,且粗骨料粒径不得大于20㎜,浇捣混凝土前标出混凝土浇捣厚度,材料和混凝土质量要严格保证,随时检查是否按协作比精确计量及规定的坍落度,并按规定制作试块,在规定区域内的混凝土必需一次连续浇捣完成,不得中断,混凝土应保持连续供应。混凝土的浇筑先远后近,先高后低的原则进行。4.5养护:混凝土浇筑12-24h后,刚好用草袋覆盖浇水养护,不少于14d。5、防水层施工防水卷材施工前先检查基层的平整和干燥程度,卷材的铺设由屋面最底处往最高处方向铺贴,上下卷材铺贴方向要一样,严禁相互垂直铺贴。涂刷基层处理剂在干燥的基层上涂刷与卷材的材性配套的基层处理剂,涂刷时动作要快速,一次涂刷匀称,切忌反复涂刷。在基层处理剂干燥后弹出卷材铺贴的位置线,然后按铺贴程序在基层处理剂上涂刷胶粘剂。再用卷材铺贴在基层上,用压辊匀称滚压,解除空气,压实卷材,并留出卷材搭接宽度。防水层施工时先做好节点部位的处理,然后由屋面最低标高处向上施工。铺贴天沟、檐沟卷材时宜顺天沟、檐沟方向,削减搭接。铺贴卷材用搭接法,上下层及相邻两幅卷材搭接缝应错开,搭接宽度应满足设计和验收规范要求。卷材屋面节点部位的施工特别重要,施工中要在设计允许条件下参考常规做法,既要保证质量,又要便利施工。先高后低的原则进行。6、防水涂料层涂刷前打算:对涂刷基层进行清理和修理,并保证其平整和干燥。涂层厚度的限制试验采纳预先在刮板上固定铁丝或木条的方法,也可在屋面上
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 边缘计算与分布式储能的融合-洞察阐释
- 疗养院产业链分析-洞察阐释
- 调味品中重金属含量分析-洞察阐释
- 基于能量互联网的储能系统智能调度策略-洞察阐释
- 少儿英语培训机构运营管理方案
- 浙江经贸职业技术学院《资源环境经济学》2023-2024学年第二学期期末试卷
- 2025至2030年中国牛仔裤行业发展形势分析及市场竞争策略报告
- 长春师范大学《中医传染病学》2023-2024学年第二学期期末试卷
- 多学科视角下上升流研究-洞察阐释
- 西昌学院《定格动画制作》2023-2024学年第二学期期末试卷
- 物业工程人员服务意识培训
- 蒂森克虏伯电梯MC2-C控制系统用户手册
- GB/T 7064-2008隐极同步发电机技术要求
- GB/T 3184-1993铅铬黄
- 通力电梯技能培训教材系列:《KCE控制系统课程》
- 《中医内科学》血证-课件
- 科研伦理与学术规范期末考试1题库
- 2023年深圳市龙华产业资本投资有限公司招聘笔试题库及答案解析
- 心电监护操作评分标准
- 国开经济学(本)1-14章练习试题及答案
- 电缆桥架安装记录
评论
0/150
提交评论