Dataformat
Validslavedeviceaddressesareintherangeof0–247decimal.
Theindividualslavedevicesareassignedaddressesintherangeof1–247.0isthebroadcastaddress
Itis16bits(twobytes)unsignedintegerforeachholdingandinputregister;
CommandFormat
Function3Readholdingregister
ResponseError:
110x80|0x03ErrornumCRC (Errornumasabyte)Function4Readinput register
ResponseError:
110x80|0x04ErrornumCRC (Errornumasabyte)
Function6Presetsingleregister
ResponseError:
110x80|0x06ErrornumCRC (Errornumasabyte)
Function16Presetmultipleregister
ResponseError:
110x80|0x10ErrornumCRC (Errornumasabyte)
DeviceMessageTransmissionMode/Framing
RTUMode
WhencontrollersaresetuptocommunicateonaModbusnetworkusingRTU(RemoteTerminalUnit)mode,each8–bitbyteinamessagecontainstwo4–bithexadecimalcharacters.Eachmessagemustbetransmittedinacontinuousstream.
TheformatforeachbyteinRTUmodeis:
CodingSystem:8–bitbinary,hexadecimal0–9,A–FTwohexadecimalcharacterscontainedineach8–bitfieldofthemessage
BitsperByte:
1startbit
8databits,leastsignificantbitsentfirstNoneparity
1stopbit
ErrorCheckField:CyclicalRedundancyCheck(CRC)
Thebaudrateofthetransmissionis:
BaudRate:9600bps
MinimumCMDperiod(RS485Timeout):850ms.
Waitforminimum850mstosendanewCMDafterlastCMD.Suggestionis1s;
MaximumDataLengthDefine:
Maximumreaddatalengthis45wordsinreadcommand;Maximumupdatedatalengthis45wordsinpresetcommand;ReadorupdateregistersNO.shouldintherangeoftimesof45,
eg:1~45or96~123areOK, but40~60isnotOK;
Note:
ExcepttheCEI0-21andVDE-AR-N4105powermanagementregisters,youshouldreferthemanufactory’ssuggestionwhenwritingotherregisters;
Registermap
Itis16bits(twobytes)unsignedintegerforeachholdingandinputregister;
HoldingReg
RegisterNO.
VariableName
Description
C
ustomerW
rit
e
Value
Unit
Initialvalue
Note
00
OnOff
TheInverterOn/Offstateandtheautostartstate,Thelowbyteistheon/off(1/0),thehighbyteistheautostartstateornot(1/0).
W
0x0000;
0x0001;
0x0100;
0x0101;
0x010
1;
AutostartmeanstheautopowerACwhennextpoweron
inverter.
02
PF CMD
memorystate
Setthefollowing3,4,5,99CMDwillbememoryornot(1/0),ifnot,thesesettingsaretheinitialvalue.
W
0or1,
0
Meansthesesettingswill beacting
or notwhennext
poweron
03
ActiveRate
P
ReadInvertermax
outputactivepowerpercent
W
0-100
percent
100
04
ReactiveRate
P
ReadInvertermax
output reactivepowerpercent
W
0-100
percent
05
Powerfactor
Read Inverter
output powerfactor’s10000times
W
0-20000,
0-10000is
underexcitec,otherisoverexcite
d
10000
06
PmaxH
Normal
(high)
power
0.1VA
07
PmaxL
Normal
(low)
power
0.1VA
08
Vnormal
NormalworkPV
voltage
0.1V
09
Fwversion
H
Firmwareversion
(high)
ASCII
10
Fwversion
M
Firmwareversion
(middle)
11
FwversionL
Firmwareversion
(low)
12
Fwversion2
H
ControlFirmware
version(high)
ASCII
13
Fwversion2
M
ControlFirmware
version(middle)
14
Fwversion2
L
ControlFirmware
version(low)
15
LCD
language
LCDlanguage
W
0-4,5
23
SerialNO.5
Serialnumber5
ASCII
24
SerialNo.4
Serialnumber4
25
SerialNo.3
Serialnumber3
26
SerialNo.2
Serialnumber2
27
SerialNo.1
Serialnumber1
28
MoudleH
InverterMoudle
(high)
&*5
29
MoudleL
InverterMoudle
(low)
30
Com
Address
Communicateaddr
ess
W
1
34
AutoTestSta
rt
AutoTestStart
W
0x0001
45
SysYear
Systemtime-year
W
Yearoffset
is0
46
SysMonth
Systemtime-Month
W
47
SysDay
Systemtime-Day
W
48
SysHour
Systemtime-Hour
W
49
SysMin
Systemtime-Min
W
50
SysSec
Systemtime-
Second
W
73
ModbusVer
sion
ModbusVersion
Eg:207is
V2.07
Int(16bi
ts)
81
FreqDerateS
tart
Frequencyderating
startpoint
W
0.01HZ
90
PFLineP1_LP
PFlimitlinepoint1loadpercent
W
0-255
percent
255
means
no thispoint
91
PFLineP1_P
F
PFlimitlinepoint1
powerfactor
W
0-20000
92
PFLineP2_LP
PFlimitlinepoint2loadpercent
W
0-255
percent
255
means
no thispoint
93
PFLineP2_P
F
PFlimitlinepoint
2powerfactor
W
0-20000
94
PFLineP3_LP
PFlimitlinepoint3loadpercent
W
0-255
percent
255
means
no thispoint
95
PFLineP3_P
F
PFlimitlinepoint3
powerfactor
W
0-20000
96
PFLineP4_LP
PFlimitlinepoint4loadpercent
W
0-255
percent
255
means
no thispoint
97
PFLineP4_P
F
PFlimitlinepoint4
powerfactor
W
0-20000
99
PFModel
SetPFfunctionModel
W
0:PF=1
1:PFbyset
2:defaultPFline
3:UserPFline4:
UnderExcited(Inda)ReactivePower
5:OverExcited(Capa)ReactivePower
6:Q(v)model
100
FLrate
Frequency–load
limitrate
W
0-100
10times
InputReg
Register
NO.
VariableName
Description
Value
Unit
Note
00
InverterStatus
Inverterrunstate
0:waiting,1:normal,
3:fault
01
PpvH
Inputpower(high)
0.1W
02
PpvL
Inputpower(low)
0.1W
03
Vpv1
PV1voltage
0.1V
04
PV1Curr
PV1inputcurrent
0.1A
05
PV1WattH
PV1inputwatt(high)
0.1W
06
PV1WattL
PV1inputwatt(low)
0.1W
07
Vpv2
PV2voltage
0.1V
08
PV2Curr
PV2inputcurrent
0.1A
09
PV2WattH
PV2inputwatt(high)
0.1W
10
PV2WattL
PV2inputwatt(low)
0.1W
11
PacH
Outputpower(high)
0.1W
12
PacL
Outputpower(low)
0.1W
13
Fac
Gridfrequency
0.01Hz
14
Vac1
Three/single phase grid
voltage
0.1V
15
Iac1
Three/single phase grid
outputcurrent
0.1A
16
Pac1H
Three/single phase grid
outputwatt(high)
0.1VA
17
Pac1L
Three/single phase grid
outputwatt(low)
0.1VA
18
Vac2
Threephasegridvoltage
0.1V
19
Iac2
Threephasegridoutput
current
0.1A
20
Pac2H
Threephasegridoutput
power(high)
0.1VA
21
Pac2L
Threephasegridoutput
power(low)
0.1VA
22
Vac3
Threephasegridvoltage
0.1V
23
Iac3
Threephasegridoutput
current
0.1A
24
Pac3H
Threephasegridoutput
power(high)
0.1VA
25
Pac3L
Threephasegridoutput
0.1VA
power(low)
26
EnergytodayH
Today generate energy
(high)
0.1KWH
27
EnergytodayL
Today generate energy
today(low)
0.1KWH
28
EnergytotalH
Total generate energy
(high)
0.1KWH
29
EnergytotalL
Totalgenerateenergy(low)
0.1KWH
30
TimetotalH
Worktimetotal(high)
0.5S
31
TimetotalL
Worktimetotal(low)
0.5S
32
Temperature
Invertertemperature
0.1C
40
Faultcode
Inverterfaultbit
&*1
41
IPM
Temperature
TheinsideIPMininverter
Temperature
0.1C
64
WarningCode
WarningCode
90
Grid Fault
record1-code
GridFaultrecord1-code
91
Grid Faultrecord1-year|
month
GridFaultrecord1-year|month
Yearoffsetis2000
92
Grid Faultrecord1-day|
hour
GridFaultrecord1-day|hour
93
Grid Faultrecord1-min|
sec
GridFaultrecord1-min|sec
94
Grid Fault
record1-value
GridFaultrecord1-value
&*2
95
Grid Fault
record2-code
GridFaultrecord2-code
96
Grid Faultrecord2-year|
month
GridFaultrecord2-year|month
Yearoffsetis2000
97
Grid Faultrecord2-day|
hour
GridFaultrecord2-day|hour
98
Grid Fault
record2-min|sec
GridFaultrecord2-min|sec
99
Grid Fault
record2-value
GridFaultrecord2-value
100
Grid Fault
record3-code
GridFaultrecord3-code
101
Grid Fault
record3-year|month
GridFaultrecord3-year|month
Yearoffsetis2000
102
Grid Faultrecord3-day|
hour
GridFaultrecord3-day|hour
103
Grid Faultrecord3-min|
sec
GridFaultrecord3-min|sec
104
Grid Fault
record3-value
GridFaultrecord3-value
105
Grid Fault
record4-code
GridFaultrecord4-code
106
Grid Fault
record4-year|month
GridFaultrecord4-year|month
Yearoffsetis2000
107
Grid Fault
record4-day|hour
GridFaultrecord4-day|hour
108
Grid Fault
record4-min|sec
GridFaultrecord4-min|sec
109
Grid Fault
record4-value
GridFaultrecord4-value
110
Grid Fault
record5-code
GridFaultrecord5-code
111
Grid Fault
record5-year|month
GridFaultrecord5-year|month
Yearoffsetis2000
112
Grid Faultrecord5-day|
hour
GridFaultrecord5-day|hour
113
Grid Fault
record5-min|sec
GridFaultrecord5-min|sec
114
Grid Fault
record5-value
GridFaultrecord5-value
115
116
…
…
…
133
134
135
bTestProcess<<
8 |
bAutoTestStep
Autotestprocessorautoteststep
&*3
136
wAutoTestResu
lt
Autotestresult
&*4
137
cTestStepStop
Autoteststopstep
&*4
138
0
0
0
139
ValueLimit
Safetyvoltage/frequency
limitvalue
0.1V
140
TimeLimit
Safetytimelimitvalue
1ms
141
Realvalue
Realvoltage/frequency
value
0.1V
142
Testvalue
Autotesting
voltage/frequency value
0.1V
143
Testtreatvalue
Autotest
voltage/frequency treatvalue
0.1V
144
Testtreattime
Autotesttreattime
1ms
145
146
…
…
….
178
179
&*1: Inverterfaultcode:
Faulttypevalue
Means(Themessageshowedontheinverterwhentheinverter
hasfault)
1~23
" Error:99+x",
24
"AutoTestFailed",
25
"NoACConnection",
26
"PVIsolationLow",
27
"ResidualIHigh",
28
"OutputHighDCI",
29
"PVVoltageHigh",
30
"ACVOutrange
",
31
"ACFOutrange
",
32
" ModuleHot
"
&*2: Thevalueis0.1Vwhenthefaultisthevoltage,is0.01Hzwhenthefaultisthefrequency;&*3:
Highbyte
value
Means
lowbyte
value
Means
0
Autoteststop
0
Notest
1
Autoteststarting
1
Testinggridvolthighpro
2
Autotesting
2
Testinggridvoltlowpro
3
Testinggridfrequencyhigh
pro
4
Testinggridfrequencylowpro
&*4:Thevariable“wAutoTestResult”and“cTestStepStop”:wAutoTestResultisthesteptesttimecounter,whenitreachcTestStepStop,thissteptestwillstopandfail.
&*5:InverterModel:A,couldbeshow:“T0Q0PFU1M5S1”or“00F151”Tx=(A&0XF00000)>>20
Qx=(A&0X0F0000)>>16Px=(A&0x00F000)>>12Ux=(A&0x000F
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 小学四年级德育教学设计:期中家校共育沙龙-构建“信任·倾听·共长”的成长共同体
- 高中劳动技术《萱草智育与价值转化》项目式教学设计
- 小学六年级安全教育防范火灾人人有责主题班会教学设计
- 高三生物一轮复习教学设计:细胞膜与细胞核结构功能整合与高考突破
- 八年级道德与法治下册第四单元单元思考与行动教学设计
- 小学四年级道德与法治“走进他们班”跨班共学活动教学设计
- 苏科版七年级数学上册第一章第三节《交流·表达》教学设计
- 八年级生物血液组成与功能教学设计
- 高中语文选择性必修下册《望海潮》教学设计
- 小学四年级综合实践活动教学设计-消防安全主题班会《初起火灾的识别与扑救》
- 既有建筑加固工程施工组织设计技术标
- AI在会计信息管理中的应用
- GB/T 470-2026锌锭
- 《计算机辅助工业设计》-第6章
- (2026年)安全生产月:企业主要负责人安全生产七项法定职责解读课件
- 出口产品碳足迹核算课题申报书
- 南宁铁路局招聘笔试题库
- 单位微型消防站台账资料模板
- 部队网络安全管理
- 四川省遂宁市2025-2026学年高一上学期期末教学质量监测政治试卷
- 金川集团2026年社招考试题
评论
0/150
提交评论