版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
DSO7004BSeriesDigitalStorageOscilloscopeUserManual(Version1.1)ContentsDSO7004BSeriesDigitalStorageOscilloscopeUserManualPAGEii目录ContentsContents iCopyrightDeclaration iiiChapter1 SafetyTips 11.1 GeneralSafetySummary 11.2 SafetyTermsandSymbols 21.3 TermsonProduct 21.4 SymbolsonProduct 21.5 ProductScrapping 2Chapter2 Overview 32.1 BriefIntroductiontoDSO7004BSeries 3Chapter3 GettingStartedGuide 43.1 Installation 43.1.1 PowerSupply 43.1.2 PowerCord 43.2 FunctionalCheck 43.2.1 Powerontheoscilloscope 43.2.2 Connecttheoscilloscope 43.2.3 Observethewaveform 53.3 ProbeExamination 53.3.1 Safety 53.3.2 UseofProbeCheckWizard 63.4 ManualProbeCompensation 63.5 ProbeAttenuationSetting 73.6 SelfCalibration 7Chapter4 MainFeatureDescription 84.1 OscilloscopeSetup 84.2 Trigger 84.3 DataAcquisition 104.4 WaveformScalingandPositioning 104.5 WaveformMeasurement 11Chapter5 BasicOperation 135.1 DisplayArea 135.1.1 XYFormat 155.2 HorizontalControls 155.2.1 ScanModeDisplay(RollMode) 175.3 VerticalControls 175.3.1 MathFFT 195.4 TriggerControls 255.5 MenuandOptionButtons 315.5.1 MEASURE 315.5.2 ACQUIRE 335.5.3 UTILITY 355.5.4 CURSOR 365.5.5 HELP 365.5.6 SAVE/RECALL 375.5.7 DISPLAY 395.6 FastActionButtons 395.6.1 AUTOSET 405.6.2 Help 415.6.3 DefaultSetup 415.7 Multi-functionalKnobsandButtons 435.8 SignalConnectors 43Chapter6 ApplicationExamples 456.1 Example1:TakingSimpleMeasurements 456.2 Example2:TakingCursorMeasurements 476.3 Example3:AnalyzingInputSignalstoEliminateRandomNoise 506.4 Example4:CapturingSingle-shotSignal 516.5 Example5:UsingX-YMode 526.6 Example6:TriggeringonPulseWidth 536.7 Example7:TriggeringonVideoSignal 546.8 Example8:UsingSlopeTriggertoCaptureParticularSlopeSignal 566.9 Example9:UsingOvertimeTriggertoMeasureLongPulseSignal 576.10 Example10:UsingMathFunctionstoAnalyzeWaveforms 586.11 Example11:MeasuringDataPropagationDelay 59Chapter7 Troubleshooting 617.1 ProblemSettlement 61Chapter8 Specifications 628.1 TechnicalSpecifications 628.2 Accessories 68Chapter9 ServicesandSupport 69Chapter10 GeneralCareandCleaning 7010.1 GeneralCare 7010.2 Cleaning 70AppendixAHarmfulandPoisonousSubstancesorElements 71CopyrightDeclarationCopyrightDeclarationAllrightsreserved;nopartofthisdocumentmaybereproducedortransmittedinanyformorbyanymeans,electronicormechanical,withoutpriorwrittenpermissionfromHantekTechnologiesCo.,Ltd(hereinafterreferredtoas‘Hantek’).Hantekreservesallrightstomodifythisdocumentwithoutpriornotice.PleasecontactHantekforthelatestversionofthisdocumentbeforeplacinganorder.Hantekhasmadeeveryefforttoensuretheaccuracyofthisdocumentbutdoesnotguaranteetheabsenceoferrors.Moreover,Hantekassumesnoresponsibilityinobtainingpermissionandauthorizationofanythirdpartypatent,copyrightorproductinvolvedinrelationtotheuseofthisdocument.SafetyTipsSafetyTipsGeneralSafetySummaryReadthefollowingsafetyprecautionstoavoidinjuryandpreventdamagetothisproductoranyproductsconnectedtoit.Toevadepotentialhazards,usethisproductonlyasspecified.Onlyqualifiedpersonnelshouldperformmaintenance.Avoidfireorpersonalinjury.Usesuitablepowercord.Useonlythepowercordspecifiedforthisproductandcertifiedforthecountryofuse.Connectanddisconnectproperly.Connectaprobewiththeoscilloscopebeforeitisconnectedtomeasuredcircuits;disconnecttheprobefromtheoscilloscopeafteritisdisconnectedfrommeasuredcircuits.Groundtheproduct.Thisproductisgroundedthroughthegroundingconductorofthepowercord.Toavoidelectricshock,thegroundingconductormustbeconnectedtoearthground.Beforemakingconnectionstotheinputoroutputterminalsoftheproduct,ensurethattheproductisproperlygrounded.Connecttheprobeinarightway.Theprobegroundleadisatgroundpotential.Donotconnectthegroundleadtoanelevatedvoltage.Checkallterminalratings.Toavoidfireorshockhazard,checkallratingsandmarkingsontheproduct.Refertotheproductmanualfordetailedinformationaboutratingsbeforemakingconnectionstotheproduct.Donotoperatewithoutcovers.Donotoperatethisproductwithcoversorpanelsremoved.Avoidexposedcircuitry.Donottouchexposedconnectionsandcomponentswhenpowerispresent.Donotoperatewithsuspectedfailures.Ifyoususpectthereisdamagetothisproduct,haveitinspectedbyqualifiedservicepersonnel.Assuregoodventilation.Donotoperateinwet/dampenvironments.Donotoperateinanexplosiveatmosphere.Keepproductsurfacescleananddry.SafetyTermsandSymbolsThefollowingtermsmayappearinthismanual:WARNING.Warningstatementspointoutconditionsorpracticesthatcouldresultininjuryorlossoflife.CAUTION.Cautionstatementsidentifyconditionsorpracticesthatcouldresultindamagetothisproductorotherproperty.TermsonProductThefollowingtermsmayappearontheproduct:DANGERindicatesaninjuryhazardimmediatelyaccessibleasyoureadthemarking.WARNINGindicatesaninjuryhazardnotimmediatelyaccessibleasyoureadthemarking.CAUTIONindicatesapossiblehazardtothisproductorotherproperty.SymbolsonProductThefollowingsymbolsmayappearontheproduct:ProtecProtectiveGround(Earth)TerminalMeasurementGroundTerminalCAUTIONRefertoManualMeasurementInputTerminalMainsDisconnectedMainsDisconnectedOFF(Power)MainsConnectedON(Power)HighVoltageProductScrappingDeviceRecyclingWeneedextractandutilizenaturalresourcestoproducethisdevice.Ifyoudonotreclaimthedeviceinaproperway,somesubstancesitcontainsmaybecomeharmfulorpoisonoustoenvironmentsorhumanbodies.Toavoidthembeingreleasedoutsideandtominimizethewasteofnaturalresources,wesuggestyoureasonablycallbackthisdevicetoensureproperrecoveryandrecyclingofmostmaterialswithinit.OverviewOverviewBriefIntroductiontoDSO7004BSeriesModelChannelsBandwidthSampleRateLCDDSO7084B480MHz2GS/s7inchcolorDSO7104B4100MHz2GS/s7inchcolorDSO7204B4200MHz2GS/s7inchcolorDSO7304B4300MHz2GS/s7inchcolorTableSTYLEREF1\s2SEQTable\*ARABIC\s11ModelListofDSO7004BSeriesDSO7004BSeriesoscilloscopescoverthebandwidthsfrom80MHzto300MHz,andprovidethereal-timeandequivalentsampleratesrespectivelyupto2GSa/sand25GSa/s.Inaddition,theyhave7inchcolorTFTLCDaswellasWINDOWS-styleinterfacesandmenusforeasyoperation.What’smore,theplentymenuinformationandtheeasy-to-operatebuttonsallowyoutogaininformationasmuchaspossibleinmeasurement;themultifunctionalknobsandthepowerfulshortcutkeyshelpyousavealotoftimeinoperation;theAutosetfunctionletsyoudetectsineandsquarewavesautomatically;theProbeCheckWizardguidesyoutoadjusttheprobecompensationandsettheProbeoptionattenuationfactor.Byusingthethreemethodstheoscilloscopeprovides(context-sensitive,hyperlinks,andanindex),youmaymasteralloperationsonthedeviceinquiteashorttimesoastogreatlyimproveyourefficiencyinproductionanddevelopment.GettingStartedGuideGettingStartedGuideInstallationTokeepproperventilationoftheoscilloscopeinoperation,leaveaspaceofmorethan5cmawayfromthetopandthetwosidesoftheproduct.PowerSupplyUseapowersupplythatdelivers90to240VRMS,45to440Hz.PowerCordUseonlypowercordsdesignedforthisproduct.Referto8.2Accessoriesforspecificstandards.FunctionalCheckFollowthestepsbelowtoperformaquickfunctionalchecktoyouroscilloscope.PowerontheoscilloscopePlugintheoscilloscopeandpresstheON/OFFbutton.Thenpushthe“UTILITY->F6->F6->F6->DEFAULT”button.ThedefaultProbeoptionattenuationsettingis10X.ConnecttheoscilloscopeSettheswitchontheprobeto10XandconnecttheprobetoChannel1ontheoscilloscope.First,aligntheslotintheprobeconnectorwiththeprotuberanceontheCH1BNCandpushtoconnect;then,turntorighttolocktheprobeinplace;afterthat,connecttheprobetipandreferenceleadtothePROBECOMPconnectors.Thereisamarkonthepanel:ProbeCOMP~2V@1KHz.CH1:CH1:toconnectwiththeprobePROBECOMPObservethewaveformPresstheAUTOSETbuttonandyoushouldseewithinafewsecondsasquarewaveofabout2Vpeak-to-peakat1kHzinthedisplay.PresstheCH1MENUbuttontwicetoremoveChannel1.PushtheCH2MENUbuttonandrepeatStep2andStep3toobserveChannel2.ProbeExaminationSafetyWhenusingtheprobe,keepyourfingersbehindtheguardontheprobebodytoavoidelectricshock.Donottouchmetallicportionsoftheprobeheadwhileitisconnectedtoavoltagesource.Connecttheprobetotheoscilloscopeandconnectthegroundterminaltogroundbeforeyoustartanymeasurements.UseofProbeCheckWizardEverytimeyouconnectaprobetoaninputchannel,youshouldusetheprobecheckwizardtoverifythatthisprobeisoperatingcorrectly.Therearetwowaystodothis:Usetheverticalmenu(forexample,pushtheCH1MENUbutton)tosettheProbeoptionattenuationfactor.PresstheUTILITY->F6->F6->F6->PROBECHECKbuttontousetheProbeCheckWizardandconfiguretheprobeoptionattenuationfactorproperlyfollowingmenuprompts.ManualProbeCompensationUponthefirstconnectionofaprobeandaninputchannel,youshouldmanuallyperformthisadjustmenttomatchtheprobetotheinputchannel.Uncompensatedormiscompensatedprobesmayleadtoerrorsorfaultsinmeasurement.Toadjusttheprobecompensation,followthestepsbelow.SettheProbeoptionattenuationinthechannelmenuto10X.Settheswitchontheprobeto10XandconnecttheprobetoChannel1ontheoscilloscope.Ifyouusetheprobehook-tip,ensureitisfirmlyinsertedontotheprobe.AttachtheprobetiptothePROBECOMP~2V@1KHzconnectorandthereferenceleadtothePROBECOMPGroundconnector.DisplaythechannelandthenpresstheAUTOSETbutton.Checktheshapeofthedisplayedwaveform.CompensatedCompensatedcorrectlyOvercompensatedUndercompensatedIfnecessary,useanonmetallicscrewdrivertoadjustthevariablecapacityofyourprobeuntiltheshapeofthewaveformturnstobethesameastheabovefigure.Repeatthisstepasnecessary.Seethefigurebelowforthewayofadjustment.ProbeAttenuationSettingProbesareofvariousattenuationfactorswhichaffecttheverticalscaleofthesignal.TheProbeCheckfunctionisusedtoverifyiftheProbeattenuationoptionmatchestheattenuationoftheprobe.AsanalternativemethodtoProbeCheck,youcanpushaverticalmenubutton(suchastheCH1MENUbutton)andselecttheProbeoptionthatmatchestheattenuationfactorofyourprobe.MakesurethattheAttenuationswitchontheprobematchestheProbeoptionintheoscilloscope.Switchsettingsare1Xand10X.WhentheAttenuationswitchissetto1X,theprobelimitsthebandwidthoftheoscilloscopeto6MHz.Tousethefullbandwidthoftheoscilloscope,besuretosettheswitchto10X.SelfCalibrationTheselfcalibrationroutinehelpsoptimizetheoscilloscopesignalpathformaximummeasurementaccuracy.Youcanruntheroutineatanytimebutshouldalwaysrunitiftheambienttemperaturechangesby5℃ormore.Foramoreaccuratecalibration,pleasepowerontheoscilloscopeandwaitfor20minutesTocompensatethesignalpath,disconnectanyprobesorcablesfromthefront-panelinputconnectors.Then,pushtheUTILITYbutton,selecttheSelfCalibrationoptionandfollowthedirectionsonthescreen..MainFeatureDescriptionMainFeatureDescriptionThischapterprovidessomegeneralinformationthatyouneedtolearnbeforeusinganoscilloscope.Itcontains:1.Oscilloscopesetup2.Trigger3.Dataacquisition4.Waveformscalingandpositioning5.WaveformmeasurementOscilloscopeSetupWhileoperatingtheoscilloscope,youmayoftenusethreefeatures:Autoset,savingasetupandrecallingasetup.Hereinaftertheyareintroducedonebyone.Autoset:Thisfunctioncanbeusedtoadjustthehorizontalandverticalscalesoftheoscilloscopeautomaticallyandsetthetriggercoupling,type,position,slope,levelandmode,etc.,toacquireastablewaveformdisplay.SavingaSetup:Bydefault,theoscilloscopewillsavethesetupeachtimebeforebeingclosed,andautomaticallyrecallthesetuponcebeingturnedon.(Note:Ifyoumodifythesetup,pleasewaitformorethan5secondsbeforeturningofftheoscilloscopetoensuretheproperstorageofnewsettings.)Youcansave10settingspermanentlyintheoscilloscopeandresetthemasnecessary.RecallingaSetup:Theoscilloscopecanrecallanyofyoursavedsetupsorthedefaultfactorysetup.DefaultSetup:Theoscilloscopeispresetfornormaloperationswhenitisshippedfromthefactory.Thisisthedefaultsetup.Youmayrecallthissetupatanytimeforyourrequirements.Toviewthedefaultsettings,refertoSection5.6.3.TriggerThetriggerdetermineswhentheoscilloscopebeginstoacquiredataanddisplayawaveform.Onceatriggerisproperlysetup,theoscilloscopecanconvertunstabledisplaysorblankscreenstomeaningfulwaveforms.Hereintroducesomebasicconceptsabouttrigger.TriggerSource:Thetriggercanbegeneratedwithmultiplesources.Themostcommononeistheinputchannel(alternativebetweenCH1,CH2,CH3andCH2).Whethertheinputsignalisdisplayedornot,itcantriggernormaloperations.AlsothetriggersourcecanbeanysignalconnectedtoanexternaltriggerchannelortheACpowerline(onlyforEdgetriggers).ThesourcewiththeACpowerlineshowsthefrequencyrelationshipbetweenthesignalandtheACcommercialpower.TriggerType:Theoscilloscopehassixtypesoftriggers:Edge,Video,PulseWidth,Slope,OvertimeandAlter.EdgeTriggerusestheanalogordigitaltestcircuitsfortriggering.Ithappenswhentheinputtriggersourcecrossesaspecifiedlevelinaspecifieddirection.VideoTriggerperformsafieldorlinetriggerthroughstandardvideosignals.PulseWidthTriggercantriggernormalorabnormalpulsesthatmeettriggerconditions.SlopeTriggerusestheriseandfalltimesontheedgeofsignalfortriggering.OvertimeTriggerhappensaftertheedgeofsignalreachesthesettime.AlterTrigger,asafeatureofanalogoscilloscopes,givesstabledisplaysofsignalsattwodifferentfrequencies.MainlyitusesaspecificfrequencytoswitchbetweentwoanalogchannelsCH1andCH2sothatthechannelswillgenerateAltertriggersignalsthroughthetriggercircuitry.TriggerMode:YoucanselecttheAutoorNormalmodetodefinehowtheoscilloscopeacquiresdatawhenitdoesnotdetectatriggercondition.AutoModeperformstheacquisitionfreelyinabsenceofvalidtrigger.Itallowsthegenerationofuntriggeredwaveformswiththetimebasesetto80ms/divorslower.NormalModeupdatesthedisplayedwaveformsonlywhentheoscilloscopedetectsavalidtriggercondition.Beforethisupdate,theoscilloscopestilldisplaystheoldwaveforms.Thismodeshallbeusedwhenyouwanttoonlyviewtheeffectivelytriggeredwaveforms.Inthismode,theoscilloscopedisplayswaveformsonlyafterthefirsttrigger.Toperformasinglesequenceacquisition,pushtheSINGLESEQbutton.TriggerCoupling:TriggerCouplingdetermineswhichpartofthesignalwillbedeliveredtothetriggercircuit.Thiscanhelptoobtainastabledisplayofthewaveform.Tousetriggercoupling,pushtheTRIGMENUbutton,selectanEdgeorPulsetrigger,andthenselectaCouplingoption.TriggerPosition:Thehorizontalpositioncontrolestablishesthetimebetweenthetriggerpositionandthescreencenter.SlopeandLevel:TheSlopeandLevelcontrolshelptodefinethetrigger.TheSlopeoptiondetermineswhetherthetriggerpointisontherisingorfallingedgeofasignal.Toperformthetriggerslopecontrol,presstheTRIGMENUbutton,selectanEdgetrigger,andusetheSlopebuttontoselectrisingorfalling.TheTRIGGERLEVELknobcontrolsthetriggerpointisonwhichpositionoftheedge.TriggerslopecanberisingorfallingTriggerslopecanberisingorfallingRisingEdgeFallingEdgeTriggerlevelcanbeadjustedverticallyDataAcquisitionWhenyouacquireananalogsignal,theoscilloscopewillconvertitintoadigitalone.Therearetwokindsofacquisition:Real-timeacquisitionandEquivalentacquisition.Thereal-timeacquisitionhasthreemodes:Normal,PeakDetect,andAverage.Theacquisitionrateisaffectedbythesettingoftimebase.Normal:Inthisacquisitionmode,theoscilloscopesamplesthesignalinevenlyspacedintervalstoestablishthewaveform.Thismodeaccuratelyrepresentssignalsinmosttime.However,itdoesnotacquirerapidvariationsintheanalogsignalthatmayoccurbetweentwosamples,whichcanresultinaliasingandmaycausenarrowpulsestobemissed.Insuchcases,youshouldusethePeakDetectmodetoacquiredata.PeakDetect:Inthisacquisitionmode,theoscilloscopegetsthemaximumandminimumvaluesoftheinputsignalovereachsampleintervalandusesthesevaluestodisplaythewaveform.Inthisway,theoscilloscopecanacquireanddisplaythosenarrowpulsesthatmayhaveotherwisebeenmissedinNormalmode.However,noisewillappeartobehigherinthismode.Average:Inthisacquisitionmode,theoscilloscopeacquiresseveralwaveforms,averagesthem,anddisplaystheresultingwaveform.Youcanusethismodetoreducerandomnoise.EquivalentAcquisition:Thiskindofacquisitioncanbeutilizedforperiodicsignals.Incasetheacquisitionrateistoolowwhenusingthereal-timeacquisition,theoscilloscopewilluseafixedratetoacquiredatawithastationarytinydelayaftereachacquisitionofaframeofdata.AfterrepeatingthisacquisitionforNtimes,theoscilloscopewillarrangetheacquiredNframesofdatabytimetomakeupanewframeofdata.Thenthewaveformcanberecovered.ThenumberoftimesNisrelatedtotheequivalentacquisitionrate.TimeBase:Theoscilloscopedigitizeswaveformsbyacquiringthevalueofaninputsignalatdiscretepoints.Thetimebasehelpstocontrolhowoftenthevaluesaredigitized.UsetheSEC/DIVknobtoadjustthetimebasetoahorizontalscalethatsuitsyourpurpose.WaveformScalingandPositioningThedisplayofwaveformsonthescreencanbechangedbyadjustingtheirscaleandposition.Oncethescalechanges,thewaveformdisplaywillincreaseordecreaseinsize.Oncethepositionchanges,thewaveformwillmoveup,down,right,orleft.Thechannelreferenceindicator(locatedontheleftofthegraticule)identifieseachwaveformonthescreen.Itpointstothegroundlevelofthewaveformrecord.VerticalScaleandPosition:Theverticalpositionofawaveformcanbechangedbymovingitupanddownonthescreen.Tocomparedata,youmayalignawaveformoveranother.WhenyoupushtheVOLTS/DIVbuttontochangetheverticalscaleofawaveform,thewaveformdisplaywillcontractorexpandverticallytothegroundlevel.HorizontalScaleandPosition:PretriggerInformationYoucanadjusttheHORIZONTALPOSITIONcontroltoviewwaveformdatabeforethetrigger,afterthetrigger,orsomeofeach.Whenyouchangethehorizontalpositionofawaveform,youareactuallychangingthetimebetweenthetriggerpositionandthescreencenter.Forexample,ifyouwanttofindoutthecauseofaglitchinyourtestcircuit,youshouldtriggerontheglitchandmakethepretriggerperiodlongenoughtocapturedatabeforetheglitch.Thenyoucananalyzethepretriggerdataandperhapsfindthecause.YouareallowedtochangethehorizontalscaleofallthewaveformsbyturningtheSEC/DIVknob.Forexample,youmaywanttoseejustonecycleofawaveformtomeasuretheovershootonitsrisingedge.Theoscilloscopeshowsthehorizontalscaleastimeperdivisioninthescalereadout.Sinceallactivewaveformsusethesametimebase,theoscilloscopeonlydisplaysonevalueforalltheactivechannels.WaveformMeasurementTheoscilloscopedisplaysgraphsofvoltageversustimeandcanhelptomeasurethedisplayedwaveform.Thereareseveralwaystotakemeasurements,usingthegraticule,thecursorsorperforminganautomaticmeasurement.Graticule:Thismethodallowsyoutomakeaquick,visualestimateandtakeasimplemeasurementthroughthegraticuledivisionsandthescalefactor.Forexample,youcantakesimplemeasurementsbycountingthemajorandminorgraticuledivisionsinvolvedandmultiplyingbythescalefactor.Ifyoucounted6majorverticalgraticuledivisionsbetweentheminimumandmaximumvaluesofawaveformandknewyouhadascalefactorof50mV/division,youcouldeasilycalculateyourpeak-to-peakvoltageasfollows:6divisionsx50mV/division=300mV.Cursor:Thismethodallowsyoutotakemeasurementsbymovingthecursors.Cursorsalwaysappearinpairsandthedisplayedreadoutsarejusttheirmeasuredvalues.Therearetwokindsofcursors:AmplitudeCursorandTimeCursor.Theamplitudecursorappearasahorizontalbrokenline,measuringtheverticalparameters.Thetimecursorappearasaverticalbrokenline,measuringthehorizontalparameters.Whenusingcursors,pleasemakesuretosettheSourcetothewaveformthatyouwanttomeasureonthescreen.Tousecursors,pushtheCURSORbutton.CursorCursorCursorAutomaticMeasurement:Theoscilloscopeperformsallthecalculationsautomaticallyinthismode.Asthismeasurementusesthewaveformrecordpoints,itismoreprecisethanthegraticuleandcursormeasurements.AutomaticmeasurementsshowthemeasurementresultsbyreadoutswhichareperiodicallyupdatedwiththenewdataacquiredbytheoscilloscopeBasicOperationBasicOperationThefrontpaneloftheoscilloscopeisdividedintoseveralfunctionalareas.Inthischapterwewillgiveaquickoverviewofallcontrolbuttonsandknobsonthefrontpanelaswellasthedisplayedinformationonthescreenandrelativetestingoperations.ThefigurebelowillustratesthefrontpaneloftheDSO7004Bseriesdigitaloscilloscope.FrontPanelofDSO7004BSeriesDisplayArea1010131211171615141234567891819DisplayFormat:::YT:Vectors:Grayindicatesautopersistence;Greenmeanspersistencedisplayisenabled.Whentheiconissettogreen,thetimeforpersistencedisplaywillbeshownbehindit.:XY:DotsAcquisitionMode:Normal,PeakDetectorAverageTriggerStatus:Theoscilloscopeisacquiringpretriggereddata.Allpretriggereddatahavebeenacquiredandtheoscilloscopeisreadytoacceptatrigger.TTheoscilloscopehasdetectedatriggerandisacquiringtheposttriggerinformation.Theoscilloscopeworksinautomodeandisacquiringwaveformsintheabsenceoftriggers.Theoscilloscopeisacquiringanddisplayingwaveformdatacontinuouslyinscanmode.●Theoscilloscopehasstoppedacquiringwaveformdata.STheoscilloscopehasfinishedasinglesequenceacquisition.ToolIcon::Ifthisiconlightsup,itmeansthekeyboardoftheoscilloscopeislockedbythehostcomputerviaUSBcontrol.:Ifthisiconlightsup,itmeanstheUSBdiskhasbeenconnected.:ThisiconlightsuponlywhentheUSBslaveinterfaceisconnectedwiththecomputer.Readoutshowsmaintimebasesetting.MainTimeBaseWindowDisplayofwindow’spositionindatamemoryanddatalength.WindowTimeBaseOperatingMenushowsdifferentinformationfordifferentfunctionkeys.Readoutshowsfrequencycount.ReadoutpointsouthorizontalwaveformpositionTriggerType::Edgetriggerontherisingedge.:Edgetriggeronthefallingedge.:Videotriggerwithlinesynchronization.:Videotriggerwithfieldsynchronization.:PulseWidthtrigger,positivepolarity.:PulseWidthtrigger,negativepolarity.Pop-upPromptReadouttellstriggerlevel.Iconindicateswhetherthewaveformisinvertedornot.20MBandwidthLimit.Ifthisiconlightsup,itmeansthebandwidthlimitisenabled,otherwisedisabled.Iconindicateschannelcoupling.ChannelMarkerWindowdisplayswaveform.XYFormatTheXYformatisusedtoanalyzephasedifferences,suchasthoserepresentedbyLissajouspatterns.TheformatplotsthevoltageonCH1againstthevoltageonCH2,whereCH1isthehorizontalaxisandCH2istheverticalaxis.TheoscilloscopeusestheuntriggeredNormalacquisitionmodeanddisplaysdataasdots.Thesamplingrateisfixedat1MS/s.TheoscilloscopecanacquirewaveformsinYTformatatanysamplingrate.YoumayviewthesamewaveforminXYformat.Toperformthisoperation,stoptheacquisitionandchangethedisplayformattoXY.ThetablebelowshowshowtooperatesomecontrolsinXYformat.ControlsUsableornotinXYformatCH1VOLTS/DIVandVERTICALPOSITIONcontrolsSetthehorizontalscaleandpositionCH2VOLTS/DIVandVERTICALPOSITIONcontrolsContinuouslysettheverticalscaleandpositionReferenceorMathUnusableCursorsUnusableAutoset(displayformatresettoYT)UnusableTimebasecontrolsUnusableTriggercontrolsUnusableHorizontalControlsUsethehorizontalcontrolstochangethehorizontalscaleandpositionofwaveforms.Thehorizontalpositionreadoutshowsthetimerepresentedbythecenterofthescreen,usingthetriggertimeaszero.Whenyouchangethehorizontalscale,thewaveformwillexpandorcontracttothescreencenter.Thereadoutneartheupperrightofthescreenshowsthecurrenthorizontalpositioninsecond.Mrepresents‘MainTimeBase’,andWindicates‘WindowTimeBase’.Theoscilloscopealsohasanarrowiconatthetopofthegraticuletoindicatethehorizontalposition.1.HORIZONTALPOSITIONKnob:Usedtocontrolthetriggerpositionagainstthescreencenter.Pushthisbuttontoresetthetriggerpointbacktothescreencenter.AN:Usedtosetthehorizontalpositionaszero.Single-windowModeDual-windowMode(FullScreen)MajorWindowMajorWindowMinorWindow(ExpandedWindow)LocationofexpandedwindowdatainmemoryMulti-functionalMulti-functionalKnob3.SEC/DIVKnob:Usedtochangethehorizontaltimescalesoastomagnifyorcompressthewaveformhorizontally.Ifthewaveformacquisitionisstopped(byusingtheRUN/STOPorSINGLESEQbutton),theSE
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 煤电项目生态修复实施方案
- 2025年云南省迪庆州高职单招职业技能考试题库及参考答案详解(综合卷)
- 厂房建设工程技术交底
- 2024年汉中技师学院高职单招职业技能考试模拟试卷完整答案详解
- 2026年甘肃能源化工职业学院高职单招职业技能考试题库附答案详解【模拟题】
- 2027年益阳资水职业学院高职单招职业技能考试模拟试卷【培优B卷】附答案详解
- 2027年渠恒职业学院高职单招职业适应性测试考试题库附答案详解【B卷】
- 2024年漆宁职业学院高职单招职业适应性测试考试题库含完整答案详解【网校专用】
- 2024年湖南潇湘技师学院单招综合素质考试题库(考点精练)附答案详解
- 2025年秦盛专修高职学院高职单招职业适应性测试考试题库【综合卷】附答案详解
- 2026中国工商银行河南省分行纪检人才专项社会招聘考试备考题库及答案解析
- 机关支部2026年上半年意识形态工作总结
- 西陵区网格员考试真题试卷
- 露天矿山无人驾驶车辆运行安全技术规范
- 施工阶段成本控制目标方案
- 铜仁市2025-2026学年高考冲刺押题(最后一卷)数学试卷(含答案解析)
- 农业执法队考勤制度
- 抖音电商培训全套
- 2026年及未来5年中国天津市酒店行业发展趋势预测及投资战略研究报告
- 按病种付费与医院临床科室运营策略
- JJG(交通) 157-2020 动态剪切流变仪检定规程
评论
0/150
提交评论