版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
DSO7004BSeriesDigitalStorageOscilloscopeUserManual(Version1.1)ContentsDSO7004BSeriesDigitalStorageOscilloscopeUserManualPAGEii目录ContentsContents iCopyrightDeclaration iiiChapter1 SafetyTips 11.1 GeneralSafetySummary 11.2 SafetyTermsandSymbols 21.3 TermsonProduct 21.4 SymbolsonProduct 21.5 ProductScrapping 2Chapter2 Overview 32.1 BriefIntroductiontoDSO7004BSeries 3Chapter3 GettingStartedGuide 43.1 Installation 43.1.1 PowerSupply 43.1.2 PowerCord 43.2 FunctionalCheck 43.2.1 Powerontheoscilloscope 43.2.2 Connecttheoscilloscope 43.2.3 Observethewaveform 53.3 ProbeExamination 53.3.1 Safety 53.3.2 UseofProbeCheckWizard 63.4 ManualProbeCompensation 63.5 ProbeAttenuationSetting 73.6 SelfCalibration 7Chapter4 MainFeatureDescription 84.1 OscilloscopeSetup 84.2 Trigger 84.3 DataAcquisition 104.4 WaveformScalingandPositioning 104.5 WaveformMeasurement 11Chapter5 BasicOperation 135.1 DisplayArea 135.1.1 XYFormat 155.2 HorizontalControls 155.2.1 ScanModeDisplay(RollMode) 175.3 VerticalControls 175.3.1 MathFFT 195.4 TriggerControls 255.5 MenuandOptionButtons 315.5.1 MEASURE 315.5.2 ACQUIRE 335.5.3 UTILITY 355.5.4 CURSOR 365.5.5 HELP 365.5.6 SAVE/RECALL 375.5.7 DISPLAY 395.6 FastActionButtons 395.6.1 AUTOSET 405.6.2 Help 415.6.3 DefaultSetup 415.7 Multi-functionalKnobsandButtons 435.8 SignalConnectors 43Chapter6 ApplicationExamples 456.1 Example1:TakingSimpleMeasurements 456.2 Example2:TakingCursorMeasurements 476.3 Example3:AnalyzingInputSignalstoEliminateRandomNoise 506.4 Example4:CapturingSingle-shotSignal 516.5 Example5:UsingX-YMode 526.6 Example6:TriggeringonPulseWidth 536.7 Example7:TriggeringonVideoSignal 546.8 Example8:UsingSlopeTriggertoCaptureParticularSlopeSignal 566.9 Example9:UsingOvertimeTriggertoMeasureLongPulseSignal 576.10 Example10:UsingMathFunctionstoAnalyzeWaveforms 586.11 Example11:MeasuringDataPropagationDelay 59Chapter7 Troubleshooting 617.1 ProblemSettlement 61Chapter8 Specifications 628.1 TechnicalSpecifications 628.2 Accessories 68Chapter9 ServicesandSupport 69Chapter10 GeneralCareandCleaning 7010.1 GeneralCare 7010.2 Cleaning 70AppendixAHarmfulandPoisonousSubstancesorElements 71CopyrightDeclarationCopyrightDeclarationAllrightsreserved;nopartofthisdocumentmaybereproducedortransmittedinanyformorbyanymeans,electronicormechanical,withoutpriorwrittenpermissionfromHantekTechnologiesCo.,Ltd(hereinafterreferredtoas‘Hantek’).Hantekreservesallrightstomodifythisdocumentwithoutpriornotice.PleasecontactHantekforthelatestversionofthisdocumentbeforeplacinganorder.Hantekhasmadeeveryefforttoensuretheaccuracyofthisdocumentbutdoesnotguaranteetheabsenceoferrors.Moreover,Hantekassumesnoresponsibilityinobtainingpermissionandauthorizationofanythirdpartypatent,copyrightorproductinvolvedinrelationtotheuseofthisdocument.SafetyTipsSafetyTipsGeneralSafetySummaryReadthefollowingsafetyprecautionstoavoidinjuryandpreventdamagetothisproductoranyproductsconnectedtoit.Toevadepotentialhazards,usethisproductonlyasspecified.Onlyqualifiedpersonnelshouldperformmaintenance.Avoidfireorpersonalinjury.Usesuitablepowercord.Useonlythepowercordspecifiedforthisproductandcertifiedforthecountryofuse.Connectanddisconnectproperly.Connectaprobewiththeoscilloscopebeforeitisconnectedtomeasuredcircuits;disconnecttheprobefromtheoscilloscopeafteritisdisconnectedfrommeasuredcircuits.Groundtheproduct.Thisproductisgroundedthroughthegroundingconductorofthepowercord.Toavoidelectricshock,thegroundingconductormustbeconnectedtoearthground.Beforemakingconnectionstotheinputoroutputterminalsoftheproduct,ensurethattheproductisproperlygrounded.Connecttheprobeinarightway.Theprobegroundleadisatgroundpotential.Donotconnectthegroundleadtoanelevatedvoltage.Checkallterminalratings.Toavoidfireorshockhazard,checkallratingsandmarkingsontheproduct.Refertotheproductmanualfordetailedinformationaboutratingsbeforemakingconnectionstotheproduct.Donotoperatewithoutcovers.Donotoperatethisproductwithcoversorpanelsremoved.Avoidexposedcircuitry.Donottouchexposedconnectionsandcomponentswhenpowerispresent.Donotoperatewithsuspectedfailures.Ifyoususpectthereisdamagetothisproduct,haveitinspectedbyqualifiedservicepersonnel.Assuregoodventilation.Donotoperateinwet/dampenvironments.Donotoperateinanexplosiveatmosphere.Keepproductsurfacescleananddry.SafetyTermsandSymbolsThefollowingtermsmayappearinthismanual:WARNING.Warningstatementspointoutconditionsorpracticesthatcouldresultininjuryorlossoflife.CAUTION.Cautionstatementsidentifyconditionsorpracticesthatcouldresultindamagetothisproductorotherproperty.TermsonProductThefollowingtermsmayappearontheproduct:DANGERindicatesaninjuryhazardimmediatelyaccessibleasyoureadthemarking.WARNINGindicatesaninjuryhazardnotimmediatelyaccessibleasyoureadthemarking.CAUTIONindicatesapossiblehazardtothisproductorotherproperty.SymbolsonProductThefollowingsymbolsmayappearontheproduct:ProtecProtectiveGround(Earth)TerminalMeasurementGroundTerminalCAUTIONRefertoManualMeasurementInputTerminalMainsDisconnectedMainsDisconnectedOFF(Power)MainsConnectedON(Power)HighVoltageProductScrappingDeviceRecyclingWeneedextractandutilizenaturalresourcestoproducethisdevice.Ifyoudonotreclaimthedeviceinaproperway,somesubstancesitcontainsmaybecomeharmfulorpoisonoustoenvironmentsorhumanbodies.Toavoidthembeingreleasedoutsideandtominimizethewasteofnaturalresources,wesuggestyoureasonablycallbackthisdevicetoensureproperrecoveryandrecyclingofmostmaterialswithinit.OverviewOverviewBriefIntroductiontoDSO7004BSeriesModelChannelsBandwidthSampleRateLCDDSO7084B480MHz2GS/s7inchcolorDSO7104B4100MHz2GS/s7inchcolorDSO7204B4200MHz2GS/s7inchcolorDSO7304B4300MHz2GS/s7inchcolorTableSTYLEREF1\s2SEQTable\*ARABIC\s11ModelListofDSO7004BSeriesDSO7004BSeriesoscilloscopescoverthebandwidthsfrom80MHzto300MHz,andprovidethereal-timeandequivalentsampleratesrespectivelyupto2GSa/sand25GSa/s.Inaddition,theyhave7inchcolorTFTLCDaswellasWINDOWS-styleinterfacesandmenusforeasyoperation.What’smore,theplentymenuinformationandtheeasy-to-operatebuttonsallowyoutogaininformationasmuchaspossibleinmeasurement;themultifunctionalknobsandthepowerfulshortcutkeyshelpyousavealotoftimeinoperation;theAutosetfunctionletsyoudetectsineandsquarewavesautomatically;theProbeCheckWizardguidesyoutoadjusttheprobecompensationandsettheProbeoptionattenuationfactor.Byusingthethreemethodstheoscilloscopeprovides(context-sensitive,hyperlinks,andanindex),youmaymasteralloperationsonthedeviceinquiteashorttimesoastogreatlyimproveyourefficiencyinproductionanddevelopment.GettingStartedGuideGettingStartedGuideInstallationTokeepproperventilationoftheoscilloscopeinoperation,leaveaspaceofmorethan5cmawayfromthetopandthetwosidesoftheproduct.PowerSupplyUseapowersupplythatdelivers90to240VRMS,45to440Hz.PowerCordUseonlypowercordsdesignedforthisproduct.Referto8.2Accessoriesforspecificstandards.FunctionalCheckFollowthestepsbelowtoperformaquickfunctionalchecktoyouroscilloscope.PowerontheoscilloscopePlugintheoscilloscopeandpresstheON/OFFbutton.Thenpushthe“UTILITY->F6->F6->F6->DEFAULT”button.ThedefaultProbeoptionattenuationsettingis10X.ConnecttheoscilloscopeSettheswitchontheprobeto10XandconnecttheprobetoChannel1ontheoscilloscope.First,aligntheslotintheprobeconnectorwiththeprotuberanceontheCH1BNCandpushtoconnect;then,turntorighttolocktheprobeinplace;afterthat,connecttheprobetipandreferenceleadtothePROBECOMPconnectors.Thereisamarkonthepanel:ProbeCOMP~2V@1KHz.CH1:CH1:toconnectwiththeprobePROBECOMPObservethewaveformPresstheAUTOSETbuttonandyoushouldseewithinafewsecondsasquarewaveofabout2Vpeak-to-peakat1kHzinthedisplay.PresstheCH1MENUbuttontwicetoremoveChannel1.PushtheCH2MENUbuttonandrepeatStep2andStep3toobserveChannel2.ProbeExaminationSafetyWhenusingtheprobe,keepyourfingersbehindtheguardontheprobebodytoavoidelectricshock.Donottouchmetallicportionsoftheprobeheadwhileitisconnectedtoavoltagesource.Connecttheprobetotheoscilloscopeandconnectthegroundterminaltogroundbeforeyoustartanymeasurements.UseofProbeCheckWizardEverytimeyouconnectaprobetoaninputchannel,youshouldusetheprobecheckwizardtoverifythatthisprobeisoperatingcorrectly.Therearetwowaystodothis:Usetheverticalmenu(forexample,pushtheCH1MENUbutton)tosettheProbeoptionattenuationfactor.PresstheUTILITY->F6->F6->F6->PROBECHECKbuttontousetheProbeCheckWizardandconfiguretheprobeoptionattenuationfactorproperlyfollowingmenuprompts.ManualProbeCompensationUponthefirstconnectionofaprobeandaninputchannel,youshouldmanuallyperformthisadjustmenttomatchtheprobetotheinputchannel.Uncompensatedormiscompensatedprobesmayleadtoerrorsorfaultsinmeasurement.Toadjusttheprobecompensation,followthestepsbelow.SettheProbeoptionattenuationinthechannelmenuto10X.Settheswitchontheprobeto10XandconnecttheprobetoChannel1ontheoscilloscope.Ifyouusetheprobehook-tip,ensureitisfirmlyinsertedontotheprobe.AttachtheprobetiptothePROBECOMP~2V@1KHzconnectorandthereferenceleadtothePROBECOMPGroundconnector.DisplaythechannelandthenpresstheAUTOSETbutton.Checktheshapeofthedisplayedwaveform.CompensatedCompensatedcorrectlyOvercompensatedUndercompensatedIfnecessary,useanonmetallicscrewdrivertoadjustthevariablecapacityofyourprobeuntiltheshapeofthewaveformturnstobethesameastheabovefigure.Repeatthisstepasnecessary.Seethefigurebelowforthewayofadjustment.ProbeAttenuationSettingProbesareofvariousattenuationfactorswhichaffecttheverticalscaleofthesignal.TheProbeCheckfunctionisusedtoverifyiftheProbeattenuationoptionmatchestheattenuationoftheprobe.AsanalternativemethodtoProbeCheck,youcanpushaverticalmenubutton(suchastheCH1MENUbutton)andselecttheProbeoptionthatmatchestheattenuationfactorofyourprobe.MakesurethattheAttenuationswitchontheprobematchestheProbeoptionintheoscilloscope.Switchsettingsare1Xand10X.WhentheAttenuationswitchissetto1X,theprobelimitsthebandwidthoftheoscilloscopeto6MHz.Tousethefullbandwidthoftheoscilloscope,besuretosettheswitchto10X.SelfCalibrationTheselfcalibrationroutinehelpsoptimizetheoscilloscopesignalpathformaximummeasurementaccuracy.Youcanruntheroutineatanytimebutshouldalwaysrunitiftheambienttemperaturechangesby5℃ormore.Foramoreaccuratecalibration,pleasepowerontheoscilloscopeandwaitfor20minutesTocompensatethesignalpath,disconnectanyprobesorcablesfromthefront-panelinputconnectors.Then,pushtheUTILITYbutton,selecttheSelfCalibrationoptionandfollowthedirectionsonthescreen..MainFeatureDescriptionMainFeatureDescriptionThischapterprovidessomegeneralinformationthatyouneedtolearnbeforeusinganoscilloscope.Itcontains:1.Oscilloscopesetup2.Trigger3.Dataacquisition4.Waveformscalingandpositioning5.WaveformmeasurementOscilloscopeSetupWhileoperatingtheoscilloscope,youmayoftenusethreefeatures:Autoset,savingasetupandrecallingasetup.Hereinaftertheyareintroducedonebyone.Autoset:Thisfunctioncanbeusedtoadjustthehorizontalandverticalscalesoftheoscilloscopeautomaticallyandsetthetriggercoupling,type,position,slope,levelandmode,etc.,toacquireastablewaveformdisplay.SavingaSetup:Bydefault,theoscilloscopewillsavethesetupeachtimebeforebeingclosed,andautomaticallyrecallthesetuponcebeingturnedon.(Note:Ifyoumodifythesetup,pleasewaitformorethan5secondsbeforeturningofftheoscilloscopetoensuretheproperstorageofnewsettings.)Youcansave10settingspermanentlyintheoscilloscopeandresetthemasnecessary.RecallingaSetup:Theoscilloscopecanrecallanyofyoursavedsetupsorthedefaultfactorysetup.DefaultSetup:Theoscilloscopeispresetfornormaloperationswhenitisshippedfromthefactory.Thisisthedefaultsetup.Youmayrecallthissetupatanytimeforyourrequirements.Toviewthedefaultsettings,refertoSection5.6.3.TriggerThetriggerdetermineswhentheoscilloscopebeginstoacquiredataanddisplayawaveform.Onceatriggerisproperlysetup,theoscilloscopecanconvertunstabledisplaysorblankscreenstomeaningfulwaveforms.Hereintroducesomebasicconceptsabouttrigger.TriggerSource:Thetriggercanbegeneratedwithmultiplesources.Themostcommononeistheinputchannel(alternativebetweenCH1,CH2,CH3andCH2).Whethertheinputsignalisdisplayedornot,itcantriggernormaloperations.AlsothetriggersourcecanbeanysignalconnectedtoanexternaltriggerchannelortheACpowerline(onlyforEdgetriggers).ThesourcewiththeACpowerlineshowsthefrequencyrelationshipbetweenthesignalandtheACcommercialpower.TriggerType:Theoscilloscopehassixtypesoftriggers:Edge,Video,PulseWidth,Slope,OvertimeandAlter.EdgeTriggerusestheanalogordigitaltestcircuitsfortriggering.Ithappenswhentheinputtriggersourcecrossesaspecifiedlevelinaspecifieddirection.VideoTriggerperformsafieldorlinetriggerthroughstandardvideosignals.PulseWidthTriggercantriggernormalorabnormalpulsesthatmeettriggerconditions.SlopeTriggerusestheriseandfalltimesontheedgeofsignalfortriggering.OvertimeTriggerhappensaftertheedgeofsignalreachesthesettime.AlterTrigger,asafeatureofanalogoscilloscopes,givesstabledisplaysofsignalsattwodifferentfrequencies.MainlyitusesaspecificfrequencytoswitchbetweentwoanalogchannelsCH1andCH2sothatthechannelswillgenerateAltertriggersignalsthroughthetriggercircuitry.TriggerMode:YoucanselecttheAutoorNormalmodetodefinehowtheoscilloscopeacquiresdatawhenitdoesnotdetectatriggercondition.AutoModeperformstheacquisitionfreelyinabsenceofvalidtrigger.Itallowsthegenerationofuntriggeredwaveformswiththetimebasesetto80ms/divorslower.NormalModeupdatesthedisplayedwaveformsonlywhentheoscilloscopedetectsavalidtriggercondition.Beforethisupdate,theoscilloscopestilldisplaystheoldwaveforms.Thismodeshallbeusedwhenyouwanttoonlyviewtheeffectivelytriggeredwaveforms.Inthismode,theoscilloscopedisplayswaveformsonlyafterthefirsttrigger.Toperformasinglesequenceacquisition,pushtheSINGLESEQbutton.TriggerCoupling:TriggerCouplingdetermineswhichpartofthesignalwillbedeliveredtothetriggercircuit.Thiscanhelptoobtainastabledisplayofthewaveform.Tousetriggercoupling,pushtheTRIGMENUbutton,selectanEdgeorPulsetrigger,andthenselectaCouplingoption.TriggerPosition:Thehorizontalpositioncontrolestablishesthetimebetweenthetriggerpositionandthescreencenter.SlopeandLevel:TheSlopeandLevelcontrolshelptodefinethetrigger.TheSlopeoptiondetermineswhetherthetriggerpointisontherisingorfallingedgeofasignal.Toperformthetriggerslopecontrol,presstheTRIGMENUbutton,selectanEdgetrigger,andusetheSlopebuttontoselectrisingorfalling.TheTRIGGERLEVELknobcontrolsthetriggerpointisonwhichpositionoftheedge.TriggerslopecanberisingorfallingTriggerslopecanberisingorfallingRisingEdgeFallingEdgeTriggerlevelcanbeadjustedverticallyDataAcquisitionWhenyouacquireananalogsignal,theoscilloscopewillconvertitintoadigitalone.Therearetwokindsofacquisition:Real-timeacquisitionandEquivalentacquisition.Thereal-timeacquisitionhasthreemodes:Normal,PeakDetect,andAverage.Theacquisitionrateisaffectedbythesettingoftimebase.Normal:Inthisacquisitionmode,theoscilloscopesamplesthesignalinevenlyspacedintervalstoestablishthewaveform.Thismodeaccuratelyrepresentssignalsinmosttime.However,itdoesnotacquirerapidvariationsintheanalogsignalthatmayoccurbetweentwosamples,whichcanresultinaliasingandmaycausenarrowpulsestobemissed.Insuchcases,youshouldusethePeakDetectmodetoacquiredata.PeakDetect:Inthisacquisitionmode,theoscilloscopegetsthemaximumandminimumvaluesoftheinputsignalovereachsampleintervalandusesthesevaluestodisplaythewaveform.Inthisway,theoscilloscopecanacquireanddisplaythosenarrowpulsesthatmayhaveotherwisebeenmissedinNormalmode.However,noisewillappeartobehigherinthismode.Average:Inthisacquisitionmode,theoscilloscopeacquiresseveralwaveforms,averagesthem,anddisplaystheresultingwaveform.Youcanusethismodetoreducerandomnoise.EquivalentAcquisition:Thiskindofacquisitioncanbeutilizedforperiodicsignals.Incasetheacquisitionrateistoolowwhenusingthereal-timeacquisition,theoscilloscopewilluseafixedratetoacquiredatawithastationarytinydelayaftereachacquisitionofaframeofdata.AfterrepeatingthisacquisitionforNtimes,theoscilloscopewillarrangetheacquiredNframesofdatabytimetomakeupanewframeofdata.Thenthewaveformcanberecovered.ThenumberoftimesNisrelatedtotheequivalentacquisitionrate.TimeBase:Theoscilloscopedigitizeswaveformsbyacquiringthevalueofaninputsignalatdiscretepoints.Thetimebasehelpstocontrolhowoftenthevaluesaredigitized.UsetheSEC/DIVknobtoadjustthetimebasetoahorizontalscalethatsuitsyourpurpose.WaveformScalingandPositioningThedisplayofwaveformsonthescreencanbechangedbyadjustingtheirscaleandposition.Oncethescalechanges,thewaveformdisplaywillincreaseordecreaseinsize.Oncethepositionchanges,thewaveformwillmoveup,down,right,orleft.Thechannelreferenceindicator(locatedontheleftofthegraticule)identifieseachwaveformonthescreen.Itpointstothegroundlevelofthewaveformrecord.VerticalScaleandPosition:Theverticalpositionofawaveformcanbechangedbymovingitupanddownonthescreen.Tocomparedata,youmayalignawaveformoveranother.WhenyoupushtheVOLTS/DIVbuttontochangetheverticalscaleofawaveform,thewaveformdisplaywillcontractorexpandverticallytothegroundlevel.HorizontalScaleandPosition:PretriggerInformationYoucanadjusttheHORIZONTALPOSITIONcontroltoviewwaveformdatabeforethetrigger,afterthetrigger,orsomeofeach.Whenyouchangethehorizontalpositionofawaveform,youareactuallychangingthetimebetweenthetriggerpositionandthescreencenter.Forexample,ifyouwanttofindoutthecauseofaglitchinyourtestcircuit,youshouldtriggerontheglitchandmakethepretriggerperiodlongenoughtocapturedatabeforetheglitch.Thenyoucananalyzethepretriggerdataandperhapsfindthecause.YouareallowedtochangethehorizontalscaleofallthewaveformsbyturningtheSEC/DIVknob.Forexample,youmaywanttoseejustonecycleofawaveformtomeasuretheovershootonitsrisingedge.Theoscilloscopeshowsthehorizontalscaleastimeperdivisioninthescalereadout.Sinceallactivewaveformsusethesametimebase,theoscilloscopeonlydisplaysonevalueforalltheactivechannels.WaveformMeasurementTheoscilloscopedisplaysgraphsofvoltageversustimeandcanhelptomeasurethedisplayedwaveform.Thereareseveralwaystotakemeasurements,usingthegraticule,thecursorsorperforminganautomaticmeasurement.Graticule:Thismethodallowsyoutomakeaquick,visualestimateandtakeasimplemeasurementthroughthegraticuledivisionsandthescalefactor.Forexample,youcantakesimplemeasurementsbycountingthemajorandminorgraticuledivisionsinvolvedandmultiplyingbythescalefactor.Ifyoucounted6majorverticalgraticuledivisionsbetweentheminimumandmaximumvaluesofawaveformandknewyouhadascalefactorof50mV/division,youcouldeasilycalculateyourpeak-to-peakvoltageasfollows:6divisionsx50mV/division=300mV.Cursor:Thismethodallowsyoutotakemeasurementsbymovingthecursors.Cursorsalwaysappearinpairsandthedisplayedreadoutsarejusttheirmeasuredvalues.Therearetwokindsofcursors:AmplitudeCursorandTimeCursor.Theamplitudecursorappearasahorizontalbrokenline,measuringtheverticalparameters.Thetimecursorappearasaverticalbrokenline,measuringthehorizontalparameters.Whenusingcursors,pleasemakesuretosettheSourcetothewaveformthatyouwanttomeasureonthescreen.Tousecursors,pushtheCURSORbutton.CursorCursorCursorAutomaticMeasurement:Theoscilloscopeperformsallthecalculationsautomaticallyinthismode.Asthismeasurementusesthewaveformrecordpoints,itismoreprecisethanthegraticuleandcursormeasurements.AutomaticmeasurementsshowthemeasurementresultsbyreadoutswhichareperiodicallyupdatedwiththenewdataacquiredbytheoscilloscopeBasicOperationBasicOperationThefrontpaneloftheoscilloscopeisdividedintoseveralfunctionalareas.Inthischapterwewillgiveaquickoverviewofallcontrolbuttonsandknobsonthefrontpanelaswellasthedisplayedinformationonthescreenandrelativetestingoperations.ThefigurebelowillustratesthefrontpaneloftheDSO7004Bseriesdigitaloscilloscope.FrontPanelofDSO7004BSeriesDisplayArea1010131211171615141234567891819DisplayFormat:::YT:Vectors:Grayindicatesautopersistence;Greenmeanspersistencedisplayisenabled.Whentheiconissettogreen,thetimeforpersistencedisplaywillbeshownbehindit.:XY:DotsAcquisitionMode:Normal,PeakDetectorAverageTriggerStatus:Theoscilloscopeisacquiringpretriggereddata.Allpretriggereddatahavebeenacquiredandtheoscilloscopeisreadytoacceptatrigger.TTheoscilloscopehasdetectedatriggerandisacquiringtheposttriggerinformation.Theoscilloscopeworksinautomodeandisacquiringwaveformsintheabsenceoftriggers.Theoscilloscopeisacquiringanddisplayingwaveformdatacontinuouslyinscanmode.●Theoscilloscopehasstoppedacquiringwaveformdata.STheoscilloscopehasfinishedasinglesequenceacquisition.ToolIcon::Ifthisiconlightsup,itmeansthekeyboardoftheoscilloscopeislockedbythehostcomputerviaUSBcontrol.:Ifthisiconlightsup,itmeanstheUSBdiskhasbeenconnected.:ThisiconlightsuponlywhentheUSBslaveinterfaceisconnectedwiththecomputer.Readoutshowsmaintimebasesetting.MainTimeBaseWindowDisplayofwindow’spositionindatamemoryanddatalength.WindowTimeBaseOperatingMenushowsdifferentinformationfordifferentfunctionkeys.Readoutshowsfrequencycount.ReadoutpointsouthorizontalwaveformpositionTriggerType::Edgetriggerontherisingedge.:Edgetriggeronthefallingedge.:Videotriggerwithlinesynchronization.:Videotriggerwithfieldsynchronization.:PulseWidthtrigger,positivepolarity.:PulseWidthtrigger,negativepolarity.Pop-upPromptReadouttellstriggerlevel.Iconindicateswhetherthewaveformisinvertedornot.20MBandwidthLimit.Ifthisiconlightsup,itmeansthebandwidthlimitisenabled,otherwisedisabled.Iconindicateschannelcoupling.ChannelMarkerWindowdisplayswaveform.XYFormatTheXYformatisusedtoanalyzephasedifferences,suchasthoserepresentedbyLissajouspatterns.TheformatplotsthevoltageonCH1againstthevoltageonCH2,whereCH1isthehorizontalaxisandCH2istheverticalaxis.TheoscilloscopeusestheuntriggeredNormalacquisitionmodeanddisplaysdataasdots.Thesamplingrateisfixedat1MS/s.TheoscilloscopecanacquirewaveformsinYTformatatanysamplingrate.YoumayviewthesamewaveforminXYformat.Toperformthisoperation,stoptheacquisitionandchangethedisplayformattoXY.ThetablebelowshowshowtooperatesomecontrolsinXYformat.ControlsUsableornotinXYformatCH1VOLTS/DIVandVERTICALPOSITIONcontrolsSetthehorizontalscaleandpositionCH2VOLTS/DIVandVERTICALPOSITIONcontrolsContinuouslysettheverticalscaleandpositionReferenceorMathUnusableCursorsUnusableAutoset(displayformatresettoYT)UnusableTimebasecontrolsUnusableTriggercontrolsUnusableHorizontalControlsUsethehorizontalcontrolstochangethehorizontalscaleandpositionofwaveforms.Thehorizontalpositionreadoutshowsthetimerepresentedbythecenterofthescreen,usingthetriggertimeaszero.Whenyouchangethehorizontalscale,thewaveformwillexpandorcontracttothescreencenter.Thereadoutneartheupperrightofthescreenshowsthecurrenthorizontalpositioninsecond.Mrepresents‘MainTimeBase’,andWindicates‘WindowTimeBase’.Theoscilloscopealsohasanarrowiconatthetopofthegraticuletoindicatethehorizontalposition.1.HORIZONTALPOSITIONKnob:Usedtocontrolthetriggerpositionagainstthescreencenter.Pushthisbuttontoresetthetriggerpointbacktothescreencenter.AN:Usedtosetthehorizontalpositionaszero.Single-windowModeDual-windowMode(FullScreen)MajorWindowMajorWindowMinorWindow(ExpandedWindow)LocationofexpandedwindowdatainmemoryMulti-functionalMulti-functionalKnob3.SEC/DIVKnob:Usedtochangethehorizontaltimescalesoastomagnifyorcompressthewaveformhorizontally.Ifthewaveformacquisitionisstopped(byusingtheRUN/STOPorSINGLESEQbutton),theSE
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2026年临邑县带编教师招聘考试备考题库及答案解析
- 裸土扬尘污染整治培训讲义
- 城市防洪排涝工程项目社会稳定风险评估报告
- 2026年中医执业医师考试中医法律法规重点习题
- 老旧片区城市更新项目社会稳定风险评估报告
- 机械零部件尺寸检测作业规范
- 年产5万吨秸秆纤维综合利用项目可行性研究报告
- 城市光储充一体化充电站项目可行性研究报告
- 2026年事业单位招聘教师《小学语文教学设计》模拟试题冲刺版
- 2026年莎车县带编教师招聘笔试备考试题及答案解析
- 建筑工地安全风险评估制度
- 2026年花艺师高级工模拟试卷及参考答案
- GB 28480-2026首饰安全技术要求
- 儿童内分泌系统疾病保健
- 2025-2030中国生物聚乳酸(PLA)市场运行监测与投资动态分析研究报告
- 2026年压缩空气储能电站安全技术规范实施要点
- 2026年技能人才评价外部质量督导员考试试卷及答案
- 2026北京市公安局监所管理总队招聘勤务辅警300人考试参考试题及答案解析
- 深度解析(2026)《SYT 7813-2024 天然气取样系统性能评价》
- 质粒构建的原理及技术
- 机修钳工知识培训课件
评论
0/150
提交评论