DPI705E/705E-ISDigitalPressureIndicator

UserManual

D

Introduction

ThisusermanualcoverstheDPI705E/DPI705E-ISmeasurementinstrumentanditsassociatedremoteprobes,PM700E/PM700E-ISforpressuremeasurementandRTD-INTERFACE/

RTD-INTERFACE-ISfortemperaturemeasurement.

UnlessspecificallystatedinasectionallreferencestoDPI705EcoverbothDPI705E(non-IntrinsicallySafe)andDPI705E-IS(IntrinsicallySafe).ThisalsoappliestoPM700E,PM700E-ISandRTD-INTERFACE,RTD-INTERFACE-IS.

RTD-INTERFACEDPI705E DPI705E-IS

PM700E(Absolute,Gauge) PM700E(Differential)

DPI705ESeriesDigitalPressureIndicator

TheDruckDPI705Epressureindicatorusesasilicontransducertoproduceapressurereadinginvariouspressuremeasurementunits.TheseuserinstructionsincludetheoperationsforallDPI705EPressureIndicators,safetyinstructionsandtherequirementsforintrinsicallysafeinstruments.

ThePM700EprovidearemotepressuresensorfunctionfortheDPI705Etoallowmoreconvenientconnectionwhendirectconnectionofthehandheldinstrumentwouldbeinconvenient.ThePM700Eisa“plugandplay”deviceholdingitsowncalibrationdata,soitcanbeusedtohavemultiplepressurerangesensorsavailableforimmediateusewithasingleDPI705Einstrument.

TheRTD-INTERFACEisaremoteinterfaceforusewiththeDPI705EortheDPI620GtoallowconnectionofaPT100RTDprobetotheinstrumentforthepurposeofmeasuringtemperature.

Forallaccuracyspecificationsetcrefertotherelevantproductdatasheet,availablefordownloadfrom

HYPERLINK

D/essential

.

Copyright2019BakerHughes,aGEcompany,LLC(“BHGE”)—Allrightsreserved.137M7122DPI705E/DPI705EISUserManual–English|i

CommercialandIntrinsicallySafeProductversions

TheDPI705Eisavailableaseithernon-IntrinsicallySafe(blueincolor)orIntrinsicallysafe(yellowincolor)versions,withcasecoloringusedaswellaslabelingtoindicatetheversion.

TheremotepressuresensorPM700EandtheremoteRTDinterfaceRTD-INTERFACEareavailableaseithernon-IntrinsicallySafeorIntrinsicallysafeversions.Theoutermetalbodyoftheproductismarkedwithitspartnumberandrelevantapprovals.

Safety

ForallsafetyinformationonbothcommercialandIntrinsicallySafeversionsrefertotheQuickStartandSafetyManualprovidedwiththeunitandalsoavailablefordownloadon

HYPERLINK

D/essential.

PressureConnectorsandAdaptors

TheDPI705EandPM700EarefittedwithfemaleG1/8pressureconnectorsforthemainpressureportP1forranges25mbar-200bar(0.36psi-2900psi).Forpressures350bar-1400bar(5000psi-20000psi)Autoclavemalepressureconnectorsareused.ThemainpressureportP1isshownontheleftinthepicturebelow.

Fordifferentialunits/sensorsfittedwithareferenceportaLegrisadaptorisfittedgivinga4mmtubingfitting.Thisissho w.

Variousadaptorsareavailable(eitherasaccessoriesorconfiguredwhenordering)fortheG1/8connectiontoconverttootherstandards.Pleaseseedatasheetforfulldetails.

PartCode

IO-ADAPT-G1/4

IO-ADAPT-1/4NPT

IO-ADAPT-1/8NPT

IO-ADAPT-QF

Description

G1/4femaleadaptor

1/4NPTadaptor

1/8NPTadaptor

Quick-fithoseadaptor

Copyright2019BakerHughes,aGEcompany,LLC(“BHGE”)—Allrightsreserved.ii|137M7122DPI705E/DPI705EISUserManual–English

Seebelowforcautionsonadaptorandconnectorfitting:

3 τ;>Xq

: ; 0;;:mrpf1

4:

: ; > 4

12345

Batteries

DPI705EorPM700EG1/8portBondedseal110N3018

ISO228/1G1/8

NPTthreadpressureconnectorIO-ADAPT-1/4NPTorIO-ADAPT-1/8NPTNPTfemaletoG1/8maleadapterpartnumberIO-ADAPT-1/4NPT

ForcompatiblebatterytypesrefertoQuickStartandSafetyManualprovidedwiththeunitandalsoavailablefordownloadon

HYPERLINK

D/essential

Theinstrumentrequires4xAA/LR6batteries,fittedasshownbelow.UseasmallPosidrivescrewdrivertoloosenthescrewsinthebatterycompartmentcoverandfitasperthebatteryorientationshownonthebackoftheinstrumentasillustratedbelow:

Copyright2019BakerHughes,aGEcompany,LLC(“BHGE”)—Allrightsreserved.137M7122DPI705E/DPI705EISUserManual–English|iii

ExternalSensors

TheDPI705Esupportstwotypesofexternalsensor,bothofwhichconnectviaacableintotheright-handsideoftheunit.

Externalsensorconnector

Copyright2019BakerHughes,aGEcompany,LLC(“BHGE”)—Allrightsreserved.iv|137M7122DPI705E/DPI705EISUserManual–English

TheRTD-INTERFACEisoptionallysuppliedwithafield-rewirableM12connectorforcustomerstoconnecttheirownwire-endedRTD'sinto.ThisisaccessorypartnumberIO-RTD-M12CON.Thepinnumberingisprintedontherearoftheconnectorbodyandisreproducedbelowforclarity.

CustomerM12connectorpinout

Connectorfront Connectorrear(wiringside)

ControlsandFunctions

Function

Power

Filter

Leak

Tare

Units

Backlight

Alarm

Zero

Settings

Control

(PressSimultaneously)

(PressSimultaneously)

(PressSimultaneously)

Description

Turntheinstrumentonoroff.

Usetogetastablepressurereadingoveranoisypressuresource.

IthasasecondaryfunctionasaBackkey.

Usetomeasurepressureleaksoveraconfigurabletimeinterval

IthasasecondaryfunctionasanOKkey.

SetatemporaryzeroforrelativemeasurementsbyusingtheTarefeature.

IthasasecondaryfunctionasanIncrementkey.

ChangethemeasurementunitoftheinstrumentIthasasecondaryfunctionasaNextkey.

Turntheinstrumentbacklighton/off.

Setahighandlowalarmbasedonahigh/lowconfigurablethreshold.

SettheZeropointforyourgaugeordifferentialsensorbeforeperformingmeasurement.

PerformAdvancedoperationssuchassensorcalibration,configurecalibrationinterval,units,userPIN,displaylockbehaviorandfactoryreset.Alsochecksensorfull-scalevalues,systemdate/time,softwareversionandotherGeneralsettings.

Copyright2019BakerHughes,aGEcompany,LLC(“BHGE”)—Allrightsreserved.137M7122DPI705E/DPI705EISUserManual–English|v

DisplaySegments

TheDPI705Edisplaysegmentisexplainedbelow:

2 3 4 5 6 7 8 9

1

18 10

17

16

15

14

1113 12

1. LeakTestIndicator3. FilterOnIndicator

5. CalibrationDueIndicator

7. InternalSensorFunctionalIndicator9. AlarmStateIndicator

11.Resistance(Ohms)Indicator13.PressureUnitsIndicator

15.SensorTypeAbsolute/GaugeIndicator17.NegativeValueIndicator

2. BatteryLevelIndicator

4. ExternalSensorFunctionalIndicator6. RemoteStateIndicator

8. LockIndicator

10.TemperatureDegreeIndicator12.CustomUnitsIndicator

14.TareIndicator

16.MinimumSymbolIndicator18.MaximumSymbolIndicator

Copyright2019BakerHughes,aGEcompany,LLC(“BHGE”)—Allrightsreserved.vi|137M7122DPI705E/DPI705EISUserManual–English

Contents

1. BasicFunctionality 11.1 Turnon/off11.2 PressureMeasurement21.3 TemperatureMeasurement21.4 ZERO31.5 TARE41.6 FILTER41.7 UNITS41.8 Backlight5

2. AdvancedFunctionality 62.1 MaximumReading62.2 MinimumReading62.3 LeakTest72.4 Alarm8

2.4.1SetHighAlarm92.4.2SetLowAlarm11

3.Settings133.1AdvancedSettings14

3.1.1 AdjustSensorCalibration 143.1.2 CalibrateSensor 163.1.3 SetCalibrationDate 183.1.4 SetCalibrationDueInterval 183.1.5 ChangeUserPIN 193.1.6 UnitsLock 213.1.7 LockDisplay 223.1.8 FactoryReset 23

3.2 GeneralSettings 243.2.1 Full-scaleValue 253.2.2 CalibrationDueDate 253.2.3 Audio 263.2.4 Autoshutdown 273.2.5 BatteryType 283.2.6 Date 293.2.7 Time 313.2.8 CustomUnit 323.2.9 SoftwareVersion 34

4. Accessories 36

5. ErrorCodes&Diagnostics 375.1 ErrorCodes375.2 Diagnostics38

Copyright2019BakerHughes,aGEcompany,LLC(“BHGE”)—Allrightsreserved.137M7122DPI705E/DPI705EISUserManual–English|vii

6.ApprovedServiceCenters386.1ReturnGoods/MaterialProcedure38

Copyright2019BakerHughes,aGEcompany,LLC(“BHGE”)—Allrightsreserved.viii|137M7122DPI705E/DPI705EISUserManual–English

1.BasicFunctionality

1.1Turnon/off

INFORMATIONIfnodatehasbeenpreviouslyset,a“ ”(Date)symbolis

displayedpromptingforasystemdate.RefertotheSection3.2.6.tosetasystemdate.Afterthedateisset,followstep3onwards.

INFORMATIONTheexternalsensorhasprecedenceovertheinternalsensor.Thismeansthatifanexternalsensorisconnected,theinstrumentwillmeasurefromtheexternalsensorbydefault.

Toturnontheunit,pressthepowerbuttonbriefly.AllthesegmentsilluminateontheLCDDisplayasshownbelow.

Uponsuccessfulpowerup,thesequenceofeventsthatfolloware,1. Thebacklightturnson(unlessdisabled).

2. Thebatterylevelisdisplayed.

3. Thepositivefull-scaleofthesensorisbrieflydisplayed.

4. Thenumberofdaysremainingtothenextcalibrationduedatearethenbrieflydisplayed.

Copyright2019BakerHughes,aGEcompany,LLC(“BHGE”)—Allrightsreserved.137M7122DPI705E/DPI705EISUserManual–English|1

5. Thesensorreadingscreenisthendisplayed.Thisisthedefaultstateormainscreenoftheinstrument.Theexampleshownbelowwillbeusedtorefertothesensorreadingscreenthroughoutthismanual

1.2PressureMeasurement

TheDPI705Ecanbeusedtomeasurepressurefromanexternalpressuresource-itdoesnotgeneratepressureitself.

Tomeasurepressure:

1. ConnectanexternalpressuresourcetobemeasuredviatheP1pressureportatthetopoftheinstrument.

2. Theinstrumentwilldisplaythemeasuredpressureusingtheinternalsensorasshownbelow.

3. Tomeasurepressureviaanexternalsensor,connectanexternalsensorviatheportontherightsideoftheinstrument.

4. Theinstrumentwillthenmeasurepressureusingtheexternalsensorasshownbelow.

Note:Thesensortype(absoluteorgauge)willbeshownonthedisplayas“ ”or“”.Differentialsensorsareindicatedasgauge.

1.3TemperatureMeasurement

TheDPI705EcanbeusedtomeasuretemperatureusingtheRTD-INTERFACE.Tomeasuretemperature:

1. ConnecttheRTD-INTERFACEviatheportontherightoftheinstrument,andconnectanRTD-PROBEorPT100totheRTD-INTERFACE.

Copyright2019BakerHughes,aGEcompany,LLC(“BHGE”)—Allrightsreserved.2|137M7122DPI705E/DPI705EISUserManual–English

2. TheinstrumentwillmeasuretemperatureinDegreesCelsiusbydefaultasshownbelow.

3. Tochangethetemperatureunit,presstheshowninDegreesFahrenheit.

4. Tochangethemeasurementunit,presstheOhms.

key.Thetemperaturereadingisthen

keyagain.Thereadingisthenshownin

1.4ZERO

CAUTIONZeroisafunctionthatcausesanon-reversibleadjustmentofthe

zeroreadingandeffectivelyadjuststhecalibrationofthesensor.Donotconfusezerowithtare-pleasereadbothsectionsifuncertain.

AzeroshouldbeperformedonaGaugeorDifferentialpressureinstrumentbeforemeasuringpressure.Thezerofunctionisnotavailableonabsolutepressuresensors(becauseabsolutevacuumwouldhavetobeappliedtothemtomakeitvalid)andisnotavailableonRTD-Interface.

Toperformazero:

1. Openallpressureportstoatmosphericpressure.

2. Pressthe and keystogether.

Copyright2019BakerHughes,aGEcompany,LLC(“BHGE”)—Allrightsreserved.137M7122DPI705E/DPI705EISUserManual–English|3

3. Thedisplaywillbrieflyshow“ ”(Zero)indicatingthatthezerofunctionhasbeensuccessful.

1.5TARE

Thetarefunctionallowsatemporaryoffsettomakethereadinggotozeroatthepointwhenthekeyispressed.Thisoffsetismaintaineduntilthe keyispressedagain,ortheunitis

poweredoff.

Totogglethetarefunctionalityonoroffpressthe key.Iftareisactivethen“ ”willbeshownonthedisplayasbelow.

1.6FILTER

Thefilterfunctionalityallowsafilteredpressurereadingbyshowingarollingaverageoflast10measurements.Thiswillgiveamorestablereadingofanoisymeasurement.

Totogglethefilterfunctionality,

1. Pressthe key.

2. Thecurrentstatusofthefilterfunctionwillbedisplayed.

3. The“ ”(Filter)indicationondisplaymeansthefilterfunctionalityison.Thedevicewillstartdisplayingfilteredreadingsonthedisplay.

4. Pressthe keyagaintoturnthefilterfunctionalityoff.Thefiltersymbolwilldisappear.

1.7UNITS

Tochangethepressureunitsofthedisplay:

Copyright2019BakerHughes,aGEcompany,LLC(“BHGE”)—Allrightsreserved.4|137M7122DPI705E/DPI705EISUserManual–English

1. Ensurethesensorreading(home)screenisshown.Otherwise,pressthe keytogobacktothepressurereadingscreen.

2. Pressthe keytogotothenextunituntilthedesiredunitofmeasureisdisplayed.

Note:Somepressureunitsarenotappropriateforsomepressureranges(e.g.mbarunitsfora1400barsensor,barfora25mbarsensoretc.).

3. TheunitslistedbelowaresupportedbyDPI705E.

PressureSensorUnits:

mbar Ib/ft2

bar kgf/cm2

Pa kgf/m2

hPa mmHg(0°C)

kPa mHg(0°C)

MPa inHg(0°C)

psi mmH2O

cmH2O(4°C)

mH2O(4°C)

inH2O(4°C)

inH2O(20°C)

ftH2O(4°C)

ftH2O(20°C)

CustomUnit

RTDInterfaceUnits:

°F Ω(Resistance) °C

CustomUnitfunctionalityallowsacustomscalingfactorforanyoneofthecurrentunitswhichthenautomaticallygetsappliedforallunits.SeeSection3.2.8formoredetails.

Acustomunitisindicatedbyadownarrowonthebottomrightcornerofthedisplay.

1.8Backlight

Thebacklightworksin3modes:Defaultmode

• Backlightturnsonforafewsecondsatanykeypress(includingbriefpressofbacklightkey).Permanentlyonmode

1. PressandHoldthebacklightkeyontheinstrumentuntilthebacklightturnson.2. Adoublebeepisheardifaudioisenabled.

3. Thebacklightshouldthenremainon(regardlessofkeypress).

4. Toreturnthebacklighttodefaultmodeshortpressthebacklightkey.Permanentlyoffmode

1. PressandHoldthebacklightkeyontheinstrumentuntilthebacklightturnsoff.2. Adoublebeepisheardifaudioisenabled.

3. Thebacklightshouldthenremainoff(regardlessofkeypress).

4. Toreturnthebacklighttodefaultmodeshortpressthebacklightkey.

Copyright2019BakerHughes,aGEcompany,LLC(“BHGE”)—Allrightsreserved.137M7122DPI705E/DPI705EISUserManual–English|5

2.AdvancedFunctionality2.1MaximumReading

Themaximumreadingisthehighestreadbytheinstrumentsincepowerup.Thevaluewillbereseteachtimethedeviceisturnedoff.

Toview/resetthemaximumpressurereading:

1. Ensurethedisplayisonthesensorreadingscreenasshownintheexamplebelow.

2. Pressthe key.

3. Thedisplaywillthenshowthemaximumrecordedreading.Note:

• Theup-arrowonthedisplayindicatesthatthecurrentreadingisthemaximumpressurereading.e.g.11mbar.

• Ifthereisadashsymbolbelowtheuparrow,itmeansthereadingisnegative(notshownincurrentexample).

4. Toresetthemaximumpressurereading,pressandholdthe keyuntilabeepsoundisheard(ifaudioisenabled).

5. Thereadingwillthenreset,andtheunitwillimmediatelystartmeasuringagain,butisstillonlyshowingthemaximumreadingonthedisplay-thisiseffectivelyPeakHoldmode.

6. Pressthe keytoexitmaximumdisplaymode.

2.2MinimumReading

Theminimumreadingisthelowestreadbytheinstrumentsincepowerup.Thevaluewillbereseteachtimethedeviceisturnedoff.

Toview/resettheminimumpressure:

Copyright2019BakerHughes,aGEcompany,LLC(“BHGE”)—Allrightsreserved.6|137M7122DPI705E/DPI705EISUserManual–English

1. Ensurethedisplayisonthesensorreadingscreenasshownintheexamplebelow.

2. Pressthe key.

3. Thedisplaywillshowmaximumpressurereading,withup-arrow.

4. Pressthe keyagaintoseetheMinimumPressurereading.Note:

• Thedown-arrowonthedisplayindicatesthatthecurrentreadingistheminimumpressurereading.

• Thedashabovethedownarrowindicatesthatthereadingisnegative.Thedisplaybelowshows-16mbar.

5. Toresettheminimumpressurereading,pressandholdthe keyuntilabeepsoundisheard(ifaudioisenabled).

6. Thereadingwillthenreset,andtheunitwillimmediatelystartmeasuringagain,butisstillonlyshowingtheminimumreadingonthedisplay-thisiseffectivelynegativePeakHoldmode.

7. Pressthe keytoexitminimumdisplaymode.

2.3LeakTest

Thisfeatureisusedtodeterminewhetherthereisaleakintheconnectedsystembyrecordingthepressurechangeoveraperiodoftime.LeaktestcanalsobeusedwiththeRTD-INTERFACEtorecordtemperaturechangeovertime.

Toperformaleaktest,followthesequenceofstepsbelow:

Copyright2019BakerHughes,aGEcompany,LLC(“BHGE”)—Allrightsreserved.137M7122DPI705E/DPI705EISUserManual–English|7

1. Ensurethedisplayisonthesensorreadingscreen.

2. Pressthe key3times.

3. Aclocksymbolappearsinthetopleftcornerofthedisplay.Theleaktesttimeappearswithdefaultat60seconds.

4. Tochangethetimervalue,pressthe key,thedisplaywillcycle60,120,300seconds.

5. Pressthe keytostarttheleaktestfortheselectedtimeduration.Thetimerdisplaycountsdownandthepointerintheclocksymbolwillrotateforthespecifiedduration.

6. Afterthetimehaselapsed,thedisplaywillshowthechange(leak)rateperminuteineitherpressureunitsortemperature/resistanceforRTD-INTERFACE.Theclocksymbolthenchangestosteady,andthecurrentconfiguredmeasurementunitwillbevisibleatthebottomofthedisplay.

7. ToleavetheLeakTestscreen,pressthe key.

2.4Alarm

Thealarmfeatureallowsanalarmtobesetbasedoncertainconditions.Forexample,pressurevalueaboveorbelowusersetlimits.

Copyright2019BakerHughes,aGEcompany,LLC(“BHGE”)—Allrightsreserved.8|137M7122DPI705E/DPI705EISUserManual–English

Thesteadyappearanceofabellicononthetoprightcornerofthedisplayindicatesthatthealarmfeatureisenabledandhighandlowthresholdvaluesforthealarmtriggerarealreadyset.

Whenthealarmistriggeredthebelliconflashes,thereadingflashesandthebacklightflashes.Bydefault,thealarmsoundsfor60secondsbutthedisplayflashesuntilthealarmconditionisremoved.

Toturnthealarmfeatureonoroff:

1. Ensurethedisplayisonthesensorreadingscreen.

2. Pressthe and keyssimultaneously.

3. Thecurrentstateofthealarmwillbedisplayedasshownbelow.

4. Tochangethestateofthealarm,pressthe keyasshownabove.

5. Pressthe tosavethechangesandreturntothesensorreadingscreen.6. Oncethealarmison,twoalarmtypesareavailable:

a. Highalarm:Alarmwillbetriggeredwhenthemeasurementgoesabovethehighthresholdvalue.

b. Lowalarm:Alarmwillbetriggeredwhenthemeasurementgoesbelowthelowthresholdvalue.

Note:

• TheinstrumentwillnottriggeranalarmifthealarmstateissettoOFF.• SeeSection2.4.1andSection2.4.2tosethigh/lowalarmthresholds.

• Highandlowalarmsareindependentofeachother.Eitheroneorbothcanbeenabled.

2.4.1SetHighAlarm

Thehighalarmcanbesettoprovideanalarmwhenpressureortemperatureexceedsthesethighthresholdvalue.

Note:Thechosenlimitmustbewithintherangeofthesensor.Forexample,ifasensor'srangecoverspositivevaluesonly,thenanegativelimitcannotbeset.

Tosetahighalarm:

Copyright2019BakerHughes,aGEcompany,LLC(“BHGE”)—Allrightsreserved.137M7122DPI705E/DPI705EISUserManual–English|9

1. Ensurethedisplayisonthesensorreadingscreen.

2. Pressthe and keyssimultaneously.

3. Thecurrentstateofthealarmwillbedisplayedasshownbelow.EnsurethealarmissettoON.

4. Pressthe keytonavigatetothehighalarmscreen.Thereadingvalueforthehighalarmwillbeshown.

Note:

• Theup-arrowontheleftindicatesthatthisisthemaximumvalue.

• Ifnovalueisset,thebelowscreenindicatesthatavaluemustbeset.

5. Tochangethisvalue,pressthe key-the'currentdigit'willflashbriefly.

6. Usethe

7. Usethe

keytoincrementthecurrentdigitvalue.

keytomovetothenextdigit.

8. Whenalldigitshavebeenprocessed,pressthe keytosavethevalue.

Copyright2019BakerHughes,aGEcompany,LLC(“BHGE”)—Allrightsreserved.10|137M7122DPI705E/DPI705EISUserManual–English

Note:

• Tosetanegativevalue,pressthesymbolsflash,thenpressthe

keyuntiltheup-arrowanddown-arrowkeytotogglethenegativevaluesymbol.

•Settingavaluebeyondthesensorrangevalueproducesanerroronthescreenasshownbelow.Ifthishappenspressthekeyandenterthevalueagain.

9. Pressthe keytogotothemainscreen.

2.4.2SetLowAlarm

Thelowalarmallowsanalarmtobesetforwhenpressurereadinggoesbelowthealarmlowthreshold

Tosetalowalarm:

1. Ensurethedisplayisonthesensorreadingscreen.

2. Pressthe and keyssimultaneously.

3. Thecurrentstateofthealarmwillbedisplayedasa“”(On)or“ ”(Off).EnsurethealarmissettoON.

4. Pressthe keytwicetonavigatetothelowalarmscreen.Thepressurevaluesetforlowalarmwillbedisplayed.

Note:

• Thedownarrowontheleftindicatesthatthisisthelowvalue.

• Thedashabovethearrowindicatesthatthisisanegativevalue.

5. Tochangethisvalue,pressthe key.The'currentdigit'willflashbriefly.

Copyright2019BakerHughes,aGEcompany,LLC(“BHGE”)—Allrightsreserved.137M7122DPI705E/DPI705EISUserManual–English|11

6. Usethe

7. Usethe

keytoincrementthecurrentdigitvalue.

keytomovetothenextdigit.

8. Whenalldigitshavebeenprocessed,pressthe keytosavethevalue.Note:

• Tosetanegativevalue,pressthesymbolsflash,thenpressthe

keyuntiltheup-arrowanddown-arrowkeytotogglethenegativevaluesymbol.

• Settinganinvalidthresholdwillresultinanerrormessage.Forexample,Error.03

whichmeansthevalueisoutofbounds.Ifthishappenspressthe keyandenterthevalueagain.

9. Pressthe keytogotothemainscreen.

Copyright2019BakerHughes,aGEcompany,LLC(“BHGE”)—Allrightsreserved.12|137M7122DPI705E/DPI705EISUserManual–English

3.Settings

Thebelowflowdiagramshowsthemenusequenceforadvancedfeaturesontheinstrument.

AdvancedFeatureMode

GeneralSettings

DisplayFullScale

CalibrationDue

AudioON/OFF

AutoShutdownON/OFF

BatteryType

SetDate

SetTime

CustomUnitSetup*

SoftwareVersion

AdvancedSettingsEnterPINtoUnlock

AdjustSensorCalibration

SetCalibrationDate

SetCalibrationInterval

ChangeUserPIN

UnitsLock/Unlock

LockUserAccess

FactoryReset

*NotAvailablewithRTD-INTERFACE

TherearetwocategoriesofSettingswithinDPI705E,GeneralSettingsandAdvancedSettings.Toaccessthesesettings:

1. Ensurethedisplayisonthesensorreadingscreen.

2. Pressthe , and keyssimultaneously.

Copyright2019BakerHughes,aGEcompany,LLC(“BHGE”)—Allrightsreserved.137M7122DPI705E/DPI705EISUserManual–English|13

3. Thedisplaywillshow“ ”(Advanced)whichindicatesthatSettingsfunctionisselected.

4. Twotypesofoperationsareavailable:a. GotoAdvancedSettings

Thereare7advancedsettingswhichcanbeaccessedbypressingthe keyonthe“ ”(Advanced)screen.APINwillberequestedbeforetogainaccesstothesesettings.

b. GotoGeneralSettings

Thereare9generalsettingswhichcanbeaccessedbypressingthe keyfromthe“ ”(Advanced)screen.

Thesectionsbelowexplainthetwocategoriesofsettings

3.1AdvancedSettings

ThesefeaturescanbeaccessedthroughtheAdvancedSettingswhichrequiresa4-digitunlockPIN.

Setting

AdjustSensorCalibration

SetCalibrationDate

SetCalibrationDueInterval

ChangeUserPIN

UnitsLock

LockDisplay

FactoryReset

Description

Performcalibrationofthesensor

Changecalibrationdate

Changecalibrationinterval(default365days)

ChangeuserPINorlockcode

Disableorenablemeasurementunits(allunitsareenabledbydefault)

Lockuserinterfacetoallowrestrictedaccesstocertainfunctionality

Resettheinstrumenttoitsfactorysettings

INFORMATIONThedefaultPINis4321.ItishighlyrecommendedtochangethedefaultPINforsecurityreasons.InstructionstochangetheuserPINaredefinedinSection3.1.5.

3.1.1AdjustSensorCalibration

Thisfeatureadjuststhecalibrationoftheinternalorexternalsensor.Thesameprocedureisusedforthein

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论