EUROPEANSTANDARDNORMEEUROPÉENNEEUROPÄISCHENORM
EN50708-2-1
May2020
ICS29.180SupersedesEN50588-1:2017(PART)andallofits
amendmentsandcorrigenda(ifany)
EnglishVersion
Powertransformers-AdditionalEuropeanrequirements:Part2-
1Mediumpowertransformer-Generalrequirements
Transformateursdepuissance-Exigenceseuropeennes
supplémentaires:Partie2-1Transformateursdemoyenne
puissance
Tobecompleted
ThisEuropeanStandardwasapprovedbyCENELECon2019-10-09.CENELECmembersareboundtocomplywiththeCEN/CENELEC
InternalRegulationswhichstipulatetheconditionsforgivingthisEuropeanStandardthestatusofanationalstandardwithoutanyalteration.
ManagementCentreortoanyCENELECmember.
Up-to-datelistsandbibliographicalreferencesconcerningsuchnationalstandardsmaybeobtainedonapplicationtotheCEN-CENELEC
ThisEuropeanStandardexistsinthreeofficialversions(English,French,German).AversioninanyotherlanguagemadebytranslationundertheresponsibilityofaCENELECmemberintoitsownlanguageandnotifiedtotheCEN-CENELECManagementCentrehasthesamestatusastheofficialversions.
CENELECmembersarethenationalelectrotechnicalcommitteesofAustria,Belgium,Bulgaria,Croatia,Cyprus,theCzechRepublic,
Denmark,Estonia,Finland,France,Germany,Greece,Hungary,lceland,Ireland,Italy,Latvia,Lithuania,Luxembourg,Malta,the
Netherlands,Norway,Poland,Portugal,RepublicofNorthMacedonia,Romania,Serbia,Slovakia,Slovenia,Spain,Sweden,Switzerland,TurkeyandtheUnitedKingdom.
EuropeanCommitteeforElectrotechnicalStandardization
ComitéEuropeendeNormalisationElectrotechniqueEuropäischesKomiteefürElektrotechnischeNormung
CEN-CENELECManagementCentre:RuedelaScience23,B-1040Brussels
◎2020CENELECAllrightsofexploitationinanyformandbyanymeansreservedworldwideforCENELECMembers.
Ref.No.EN50708-2-1:2020E
2
EN50708-2-1:2020(E)
Contents
Europeanforeword 3
Introduction 4
1Scope 5
2Normativereferences 5
3Termsanddefinition 5
4Servicecondition 5
5Ratingandgeneralrequirements 5
5.1General 5
5.1.1HighestvoltagesforequipmentforwindingwithUm>1,1kV 5
5.1.2RatedvoltageforwindingwithUm≤1,1kV 5
5.1.3Tapping 6
5.1.4Connectiondesignationsforthreephasetransformers 6
5.2EnergyPerformance 6
5.2.1General 6
5.2.2Transformerswithspecialrequirements 9
6Ratingplate 11
7Tolerancesduringfactoryacceptancetests 11
8Tests 11
9Accessoriesandfittings 11
10Capitalizationlosses 11
11Transformersoverhaul 11
AnnexZZ(informative)RelationshipbetweenthisEuropeanStandardandtheecodesignrequirementsofCommissionRegulation(EU)No548/2014of21May2014anditsamendmentNo2019/1783of1October2019onimplementingDirective2009/125/ECoftheEuropeanParliamentandoftheCouncilwithregardtosmall,mediumandlarge
powertransformersaimedtobecovered12
EN50708-2-1:2020(E)
3
Europeanforeword
Thisdocument(EN50708-2-1:2020)hasbeenpreparedbyCLC/TC14"Powertransformers".
Thefollowingdatesarefixed:
·latestdatebywhichthisdocumenthas(dop)2020-11-22
tobeimplementedatnationallevelby
publicationofanidenticalnational
standardorbyendorsement
·latestdatebywhichthenational(dow)2023-05-22
standardsconflictingwiththisdocument
havetobewithdrawn
ThisdocumentsupersedesEN50588-1:2017andallofitsamendmentsandcorrigenda(ifany).
Attentionisdrawntothepossibilitythatsomeoftheelementsofthisdocumentmaybethesubjectofpatentrights.CENELECshallnotbeheldresponsibleforidentifyinganyorallsuchpatentrights.
ThisdocumenthasbeenpreparedunderamandategiventoCENELECbytheEuropeanCommissionandtheEuropeanFreeTradeAssociationandsupportsessentialrequirementsofEUDirective(s).
FortherelationshipwithEUDirective(s)seeinformativeAnnexZZ,whichisanintegralpartofthisdocument.
EN50708-2-1:2020(E)
4
Introduction
Forthepurposeofthisdocument,therequirementsofthegeneralEN50708-1-1:2020apply.
Thisdocumentcontainsparticularrequirementsforspecifictransformersortransformerapplications,whicharebasedontherequirementsofthegeneralEN50708-1-1:2020.
Thisdocumentshouldbeconsideredinconjunctionwiththerequirementsofthegeneralparts.
TheparticularrequirementsofthedifferentsubpartsofEN50708supplement,modifyorreplacecertainrequirementsofthegeneralpartsofEN50708-1and/orEN50708-1-Xbeingvalidatthetimeofpublicationofthisdocument.Theabsenceofreferencestotheexclusionofapartoraclauseofageneralpartmeansthatthecorrespondingclausesofthegeneralpartareapplicable(undatedreference).
Requirementsofother-XpartswithXgreaterthan1beingeventuallyrelevantforcasescoveredbythisdocumentalsoapply.Thisdocumentcouldthereforealsosupplement,modifyorreplacecertainoftheserequirementsvalidatthetimeofpublicationofthisdocument.
ThemainclausenumberingofeachpartfollowsthepatternandcorrespondingreferencesofEN50708-1-1:2020.Thenumbersfollowingtheparticularnumberofthisdocumentarethoseofthecorrespondingparts,orclausesoftheotherpartsoftheEN50708series,validatthetimeofpublicationofthisdocument,asindicatedinthenormativereferencesofthisdocument(datedreference).
Inthecasewhereneworamendedgeneralpartswithmodifiednumberingwerepublishedafterthesubpartwasissued,theclausenumbersreferringtoageneralpartinsubpartsmightnolongeralignwiththelatesteditionofthegeneralpart.Datedreferencesshouldbeobserved.
EN50708-2-1:2020(E)
5
1Scope
ThescopeofthisdocumentistodefinetheenergyperformanceofMediumPowerTransformersincompliancewithEN50708-1-1:2020.
2Normativereferences
Thefollowingdocumentsarereferredtointhetextinsuchawaythatsomeoralloftheircontentconstitutesrequirementsofthisdocument.Fordatedreferences,onlytheeditioncitedapplies.Forundatedreferences,thelatesteditionofthereferenceddocument(includinganyamendments)applies.
EN50708-1-1:2020,Powertransformers-AdditionalEuropeanrequirements:Part1-1:Commonpart-Generalrequirements
EN60076-1:2011,Powertransformers-Part1:General
EN60076-3:2013,Powertransformers-Part3:Insulationlevels,dielectrictestsandexternalclearancesinair
ENIEC60076-11:2018,Powertransformers-Part11:Dry-typetransformers
3Termsanddefinitions
Forthepurposesofthisdocument,thetermsanddefinitionsgiveninEN50708-1-1:2020apply.
ISOandIECmaintainterminologicaldatabasesforuseinstandardizationatthefollowingaddresses:
一IECElectropedia:availableat
/
一ISOOnlinebrowsingplatform:availableat
/obp
4Serviceconditions
SeeEN60076-1:2011.
5Ratingandgeneralrequirements
5.1General
5.1.1HighestvoltagesforequipmentforwindingwithUm>1,1kV
InsulationlevelsanddielectrictestshallbeinaccordancewiththerequirementsofEN60076-3:2013
andfordrytypetransformersinaccordancewithENIEC60076-11:2018.
ThevaluesofthehighestvoltageUmforequipmentare:
3,6kV-7,2kV-12kV-17,5KV-24kV-36kV
NOTENationalpracticesmightrequiretheuseofhighestvoltagesforequipmentupto(butnotincluding)
52kV,whentheratedvoltageislessthan36kV(suchasUm=38,5kVorUm=40,5kV).
5.1.2RatedvoltageforwindingwithUm≤1,1kV
ForUm≤1,1kV,thepreferredratedvoltagevalueshallbechoseninthehereunderlist:400V-410V-415V-420V-433V-690V
Thisdocumentmaybeappliedeitherasawholeorinpart,totransformerswithratedlowvoltagesbelow400Vandabove690V.
EN50708-2-1:2020(E)
6
Thevaluesforshortdurationpowerfrequencywithstandand/orforthelightningimpulsewithstandtestbetweenwindingsandearthneedtobestatedbythepurchaser.
5.1.3Tapping
ForDETC(De-energizedtapchanger),thepreferredtappingrangesshallbe±2,5%with3tappositionsand±2×2,5%with5tappositions.Onspecialrequest±4×2,5%with9tappositionscanbeprovided.Tappingrangesgreaterthan±10%orwithmorethan9tappositionsareunusualandsubjecttospecificagreement.
TappingrangesoutsidetheabovedefinitionsforDETCoranyrangesforOLTC(Onloadtapchanger)shallbespecifiedbyagreementbetweenmanufacturerandpurchaser.
Theleveloflossesofthisstandardshallbecompliantwhatevertherangesandmethodsoftapping.NOTEOLTCmeansalsotransformersequippedwithtappingconnectionssuitableforoperationwhiletransformerisenergisedoronloadforvoltageadaptationpurposes.
5.1.4Connectiondesignationsforthreephasetransformers
Preferredconnectiondesignations(IEV[421-10-09])shallbeinaccordancewithclocknotation5or11withDyn,unlessotherwiseagreedbetweenmanufacturerandpurchaser.
5.2EnergyPerformance
5.2.1General
Introduction
Thetablesbelowindicatethemaximumleveloflossesforno-loadlossesandforloadlossesforTIER1andTIER2.
TIER1hasbeenappliedsince1July2015forthevaluesoflossesfollowingCommissionRegulation(EU)No548/2014of21May2014anditsamendmentNo2019/1783of1October2019.
TIER2shallbeappliedfrom1July2021forthevaluesoflossesfollowingCommissionRegulation(EU)No548/2014of21May2014anditsamendmentNo2019/1783of1October2019.
Table1and2defineloadlossesandno-loadlossesforonewindingwithUm≤24kVandtheotheronewithUm≤3,6kV.Additionalcorrectionsaredefinedforhighestvoltage,dualvoltageorspecialonloadtapping,giveninTable3,4,5andotherclauses.CorrectionsfactorsinTable3,4,5arecumulative.
Duringfactoryacceptancetests,themeasuredvaluesofno-loadandloadlossesshallnotexceedtherespectivemaximumvaluesdeterminedwithTable1and2and6andcorrectedbycorrectionsfactorasstatedabove.
ThereferenceconditionsdefinedinEN50708-1-1:2020applies.
Othervaluesofshort-circuitimpedancecanbespecifiedbythepurchaserforparticularsystemserviceconditions,e.g.inthecaseofparalleloperationsinalltablesofthisclause.
ThesoundpowerlevelsaregiveninTables1and2.TransformerscanberequestedorofferedwithsoundpowerlevelLwAotherthanthelistedvalues.
UnlessotherwiseagreedbetweenmanufacturerandpurchaserthesoundpowerlevelLwAgivenin
Tables1and2areconsideredfornoloadcondition.
NOTELosslevelsandcorrectionfactorsdefinedin
an
d
refertotwowindingmediumpower
transformers.Losslevelsforthreewindingsmediumpowertransformersarenotdefinedduetolackofdataatthetimeofthepublicationofthisstandard.
EXAMPLEcumulativecorrections:
IncaseoftransformershavingprimaryhighestvoltageforequipmentUm=36kVandsecondaryhighestvoltageforequipmentUm≤3,6KVallowing10%onPkand15%onP⁰accordingtoTable3,andhavingdualvoltageononewindingallowing10%onPkand15%onP0accordingtoTable4.
EN50708-2-1:2020(E)
7
ThetotalcorrectionsonPkis21%(1,1x1,1-1)andP0is32,25%(1,15x1,15-1)
Loadlossesandno-loadlossesforonewindingwithUm≤24kVandtheotheronewithUm≤3,6kV
ThefollowingtablesaredefinedforstepdownorstepuptransformerswithonewindingwithUm≤24kVandtheotheronewithUm≤3,6kV.Table1isforliquidimmersedtransformersandTable2fordry-typetransformers.
Table1—Losses,shortcircuitimpedanceandsoundpowerlevelforliquidimmersed
transformers
Ratedpower
TIER1
Pk
TIER1
Po
TIER2
Pk
TIER2
Po
LwA
Short-circuitImpedance
kVA
w
W
W
W
dB(A)
%
≤25
900
70
600
63
37
4
50
1100
90
750
81
39
4
100
1750
145
1250
130
41
4
160
2350
210
1750
189
44
4
250
3250
300
2350
270
47
4
315
3900
360
2800
324
49
4
400
4600
430
3250
387
50
4
500
5500
510
3900
459
51
4
630
6500
600
4600
540
52
4or6
800
8400
650
6000
585
53
6
1000
10500
770
7600
693
55
6
1250
11000
950
9500
855
56
6
1600
14000
1200
12000
1080
58
6
2000
18000
1450
15000
1305
60
6
2500
22000
1750
18500
1575
63
6
3150
27500
2200
23000
1980
64
6
Table2—Losses,shortcircuitimpedanceandsoundpowerlevelsfordry-typetransformers
Ratedpower
TIER1
Pk
TIER1
Po
TIER2
Pk
TIER2
Po
LwA
Short-circuitImpedance
kVA
W
W
W
W
dB(A)
%
≤50
1700
200
1500
180
49
6
100
2050
280
1800
252
51
6
160
2900
400
2600
360
54
6
250
3800
520
3400
468
57
6
400
5500
750
4500
675
60
6
630
7600
1100
7100
990
62
6
800
8000
1300
8000
1170
64
6
1000
9000
1550
9000
1395
65
6
1250
11000
1800
11000
1620
67
6
1600
13000
2200
13000
1980
68
6
2000
16000
2600
16000
2340
70
6
2500
19000
3100
19000
2790
71
6
3150
22000
3800
22000
3420
74
6
EN50708-2-1:2020(E)
8
Loadlossandno-loadlossincaseofotherhighestvoltage
TheleveloflossesgiveninTable1andinTable2shallbeweightedbythecorrectionfactorsgiveninTable3below,inordertotakecareofvariationsrelatedtothehighestvoltageforequipmentvalues.
Table3—Correctionsofthelossesforhighestvoltage
Specialcombinationofvoltagesinonewinding
Loadlosses
(Pk)
No-loadlosses
(Po)
Forbothliquidimmersed(Table1)anddrytype(Table2)
PrimaryhighestvoltageforequipmentUm≤24KV
SecondaryhighestvoltageforequipmentUm>3,6kV
Nocorrection
Nocorrection
Forliquidimmersed(Table1)
PrimaryhighestvoltageforequipmentUm=36kV
SecondaryhighestvoltageforequipmentUm≤3,6kV
10%
15%
PrimaryhighestvoltageforequipmentUm=36kV
SecondaryhighestvoltageforequipmentUm>3,6kV
10%
15%
Fordrytype(Table2)
PrimaryhighestvoltageforequipmentUm=36kV
SecondaryhighestvoltageforequipmentUm≤3,6kV
10%
15%
PrimaryhighestvoltageforequipmentUm=36kV
SecondaryhighestvoltageforequipmentUm>3,6KV
15%
20%
Loadlossandno-loadlossincaseofdualvoltage
Table4belowgivescorrectionfactorstobeappliedtotheloadandno-loadlossesindicatedinTables1,2and6formediumpowertransformerswithdualvoltageinoneorbothwindingsdifferingmorethan10%.
ThelossesshallbecalculatedonthebaseofthevoltageofthewindingspecifiedinthesecondcolumnofTable4andcanbeincreasedwiththecorrectionfactorsgiveninthelast2columnsofTable4.Inanycase,whateverthecombinationsofwindingvoltages,thelossescannotexceedthevaluesgiveninTables1,2and6correctedbythefactorsinTable4.
EN50708-2-1:2020(E)
9
Table4—Correctionsofthelossesfordualvoltage
Typeofdualvoltage
Referencevoltage
fortheapplicationofcorrectionfactors
Loadlosses
(Pk)
No-load
losses
(Po)
Dualvoltageononewindingwithreducedpoweroutputonthelowerlow-voltagewinding
AND
maximumavailablepoweronthe
lowervoltageofthelow-voltagewindinglimitedto0,85oftheratedpowerassignedtothelow-voltagewindingatitshighervoltage.
Lossesshallbe
calculatedbasedonthehighervoltageofthelow-voltage
winding
Nocorrection
Nocorrection
Dualvoltageononewindingwithreducedpoweroutputonthelowerhigh-voltagewinding
AND
maximumavailablepoweronthe
lowervoltageofthehigh-voltagewindinglimitedto0,85oftheratedpowerassignedtothehigh-voltagewindingatitshighervoltage.
Lossesshallbe
calculatedbasedonthehighervoltageof
thehigh-voltagewinding
Nocorrection
Nocorrection
DualvoltageononewindingAND
fullratedpoweravailableonbothwindings,i.e.thefullnominalpowerisavailableregardlessofthecombinationofvoltages.
Thelossesshallbecalculatedbasedonthehighervoltageofthedualvoltage
winding
10%
15%
Dualvoltageonbothwindings
AND
ratedpoweravailableonallcombinationsofwindings,i.e.bothvoltagesononewindingarefullyratedincombinationwithoneofthevoltagesontheotherwinding
Thelossesshallbecalculatedbasedonthehighervoltagesofbothdualvoltage
windings
20%
20%
Incaseoftransformerswithtwoidenticallowvoltagewindingsand/orhighvoltagewindingsinparallelconnectiondesignedwithhalfofratedpowereach,dualvoltagecorrectionfactorsgiveninTable4shouldbeapplied.
NOTEIncaseoftransformerswithdualhighvoltagewinding,theratedpowerconsideredisonthehighestratedvoltagewinding.
5.2.2Transformerswithspecialrequirements
Ratedpowernotincludedinthelist
Fortransformerhavingaratedpowerdifferentfromthevaluesgiveninthetables,alinearinterpolationshallbedone.
Transformersequippedforvoltageregulationwhileenergised
Whentransformersareequippedwithtappingconnectionssuitableforoperationwhiletransformerisenergisedoronloadforvoltageadaptationpurposes,thelevelofloadlossandno-loadlossofthelistofthisstandardshallbeincreased.
EN50708-2-1:2020(E)
10
Table5—Correctionoflossesfortransformersequippedforvoltageregulation
Pk
Po
TIER1
5%
20%
TIER2
Nocorrection
10%
Suchcorrectionsareapplicableirrespectivelyofthetechnologyusedtoperformthevoltageadaptation.
Thelossesofthetransformersarethosemeasuredduringthetestwhateverthekindoftransformers,includedalldevicestomanagetheAVRinsidethetransformers.
ForatransformerhavinganinsulationlevelaccordingtoTable3andhavingtappingconnectionssuitableforoperationwhilethetransformerisenergizedoronloadforvoltageadaptationpurposesbothcorrectionsshallbetakenintoaccount.
NOTEAVR:AutomaticVoltageRegulation:toautomaticallycontroltheinputoroutputvoltageofthetransformerforon-loadvoltageregulationpurposes.
Liquidimmersedthreephasepolemountedtransformers
Fortheone-to-onereplacementofexistingmediumpowerpole-mountedtransformerstheapplicablemaximumlevelsofloadandno-loadlossesarenottheonesinTables1and2butthoseinTable6below.MaximumallowablelossesforkVAratingsotherthanthoseexplicitlymentionedinTable6shallbeobtainedbylinearinterpolationorextrapolation.ThecorrectionfactorsforspecialcombinationsofwindingvoltagesindicatedinTables3and4arealsoapplicable.
Fortheone-to-onereplacementofexistingmediumpowerpole-mountedtransformers,themanufacturer,importerorauthorizedrepresentativeshallincludeinthetechnicaldocumentationofthetransformerthefollowinginformation:
一theaddressandcontactdetailsofthecommissionerofthereplacementtransformer;
一thestationwherethereplacementtransformeristobeinstalled.Thisshallbeunequivocallyidentifiedeitherbyaspecificlocationoraspecificinstallationtype(e.g.technicaldescriptionofthepole).
Intheabovecases,themanufacturer,importerorauthorizedrepresentativeshallnotifythecompetentnationalmarketsurveillanceauthorities.
Withregardstotheinstallationofnewpole-mountedtransformers,itistherequirementsinTables1and2,inconjunctionwithTables3and4wherejustified,whichareapplicable.
Table6—Maximumloadandno-loadlossesformediumpowerimmersedpolemounted
transformersforonetoonereplacement
Ratedpower
TIER1
Pk
TIER1
Po
TIER2
Pk
TIER2
Po
kVA
W
W
W
W
25
900
70
725
70
50
1100
90
875
90
100
1750
145
1475
145
160
3102
300
3102
270
200
2750
356
2333
310
250
3250
425
2750
360
315
3900
520
3250
440
400
4750
645
3905
545
EN50708-2-1:2020(E)
11
6Ratingplate
TheadditionalrequirementsforratingplatearegiveninEN50708-1-1:2020.
Theone-to-onereplacementofexistingmediumpowerpole-mountedtransformersshallbewrittenontheratingplatebythewords“1/1replacement”
7Tolerancesduringfactoryacceptancetests
TheadditionalrequirementsfortolerancesaregiveninEN50708-1-1:2020.
8Tests
TheadditionalrequirementsfortestsaregiveninEN50708-1-1:2020orinrelevantparts.
9Accessoriesandfittings
Listofaccessoriesandfittingsareunderdevelopmentinrelevantparts.
10Capitalizationlosses
ThecapitalizationshouldbeappliedtofixedlossesbychoosingtheadequateratedpowerorbyspecifyinglowerlossesthanthemaximumvaluesgivenintheClause5.
11Transformersoverhaul
TheadditionalrequirementsfortransformersoverhaularegiveninEN50708-1-1:2020.
EN50708-2-1:2020(E)
12
AnnexZZ
(informative)
RelationshipbetweenthisEuropeanStandardandtheecodesign
requirementsofCommissionRegulation(EU)No548/2014of21
May2014anditsamendmentNo2019/1783of1October2019on
implementingDirective2009/125/ECoftheEuropeanParliament
andoftheCouncilwithregardtosmall,mediumandlargepower
transformersaimedtobecovered
ThisEuropeanStandardhasbeenpreparedunderaCommission'sstandardizationrequestM/495toprovideonevoluntarymeansofconformingtotheecodesignrequirementsofCommissionRegulation(EU)No548/2014of21May2014anditsamendmentNo2019/1783of1October2019onimplementingDirective2009/125/ECoftheEuropeanParliamentandoftheCouncilwithregardtoecodesignrequirementsforsmall,mediumandlargepowertransformers.
OncethisstandardiscitedintheOfficialJournaloftheEuropeanUnionunderthatRegulation,compliancewiththenormativeclausesofthisstandardgiveninTableZZ.1confers,withinthelimitsofthescopeofthisstandard,apresumptionofconformitywiththecorrespondingecodesignrequirementsofthatRegulationandassociatedEFTARegulations.
TableZZ.1—CorrespondencebetweenthisEuropeanStandardandCommissionRegulation
(EU)No548/2014of21May2014anditsamendmentNo2019/1783of1October2019
implementingDirective2009/125/ECoftheEuropeanParliamentandoftheCouncilwith
regardtoecodesignrequirementsforsmall,mediumandlargepowertransformersand
Commission'sstandardizationrequestM/495
Ecodesignrequirementsof
CommissionRegulation(EU)No
548/2014of21May2014andits
amendmentNo2019/1783of
1October2019
Clause(s)/subclause(s)ofthisEN
Remarks
Annexl
Requirementsforthree-phasemediumpowertransformerswith
ratedpower≤3150KVA.
Table1.3a
Maximumloadandno-loadlosses(inW)forthree-phaseliquid-immersedmediumpowertransformerswithonewindingwithUm≤24kVandtheotherwithUm≤3,6kV
Subclause
Table1reportsthevaluesTIER1Po,i.e.themaximumvaluesof
no-loadlossesthatareapplicablefrom1July2015(Tier1).
From1July2021(Tier2),therequirementisTIER2Po.
Table1reportsthevaluesTIER1Pk,whicharethemaximumloadlossesapplicablefrom1July2015(Tier1).
From1July2021(Tier2),therequirementisTIER2Pk
EN50708-2-1:2020(E)
13
Ecodesignrequirementsof
CommissionRegulation(EU)No
548/2014of21May2014andits
amendmentNo2019/1783of
1October2019
Clause(s)/subclause(s)ofthisEN
Remarks
Annexl
Requirementsforthree-phasemediumpowertransformerswith
ratedpower≤3150KVA.
Table1.2
Maximumloadandno-loadlosses(inW)forthree-phasedry-typemediumpowertransformerswithonewindingwithUm≤24kVandtheotherwithUm≤3,6kV
Subclause
Table2reportsthevaluesTIER1Po,i.e.thema
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- T/CSTEA 00016-2021陈年武夷岩茶储存技术规范
- 电影制作公司制片人项目设计与成本核算考核表
- 食品生产设备维护保养标准流程操作手册
- 绿色环保垃圾分类管理解决方案
- 网络教育公司课程研发工程师KPI考核表
- 行业考核评估表
- 酒店服务水平提升绩效评估表
- 数据统计与分析方法手册
- 井矿盐制盐工安全意识强化考核试卷含答案
- 铁路运输工长绩效分析表
- 【第一次月考】2026 秋七年级上册道法第一次月考卷(统编版素养测评)
- 2026年非融资担保服务行业市场深度调查及投资规划报告及未来五至十年区域市场差异与机会
- 大型机械设备运行路线及作业位置承载能力校核方案
- 2026-2027学年四年级上册数学第一次月考分层训练测试完整版试卷
- 中国树莓果汁市场销售格局与未来经营效益盈利性研究报告
- 2024年秋人教版三年级英语上册电子课本
- 猪场非瘟质保协议书
- 楼房地基注浆加固施工方案
- 临时钢便桥搭建技术规范
- 安全员岗位考试及答案题库
- 2025年湖南省教育系统后备干部考试参考试题(含答案)
评论
0/150
提交评论