·1·

Foreword

ThiscodeispreparedbyChinaGuohuaEnergyInvestmentCo.,LtdinconsultationwithassociatedactivitiesinaccordancewiththerequirementsofDocumentJB〔2010〕No.43issuedbytheMinistryofConstruction(MOC)-"NoticeonPrintingtheDevelopmentandRevisionPlanofNationalEngineeringConstructionStandardsin2010".

Inpreparingthisstandard,thedraftingworkgroupmadeextensivesurveysandanalysis,heldseveralsubject-focusedseminarsanddrewonpracticesinthefieldofacceptanceofphotovoltaicpowerprojectsinrecentyearsinChina,andthenonthisbasistooknationwideinputsfrominterestedpartiesbymultiplemeansofcommunication,andorganizeddiscussionsandstudyonmajorissues,andfinalizedthepresentversionaftersubmittingforreviewandapproval.

Thisspecificationcomprisesofsevenchaptersandsixappendices,coverstechnicallygeneralprovisions,terms,basicrequirements,acceptanceofUnitProject,acceptanceforProjectstart-up,acceptanceforcommissioningandtransfertoproduction,andfinalacceptance.

ThisspecificationisunderjurisdictionofTheMinistryofHousingandUrban-RuralDevelopmentofChinaismaintainedbyChinaElectricityCouncilandinterpretedtechnicallybyChinaGuohuaEnergyInvestmentCo.,Ltd.Interestedpartiesarekindlyrequestedtomailrecommendationsconcerningthe

contentshereintoGuohuaEnergyInvestmentCo.,Ltd.(Address:GuohuaInvestmentBuilding,No.3

SouthRoadofDongzhimen,DongchengDistrict,Beijing,P.R.C.,Postcode:100007),tofurtherimprovethequalityofthisspecification.

Chiefdevelopmentorganizations,participatingorganizations,chiefdraftingstaffandchiefreviewingstaffofthecodeare:

ChiefDevelopmentOrganizations:

GuohuaEnergyInvestmentCo.,Ltd

ChinaElectricityCouncil

ParticipatingOrganizations:

GCLSolarSystemLimited

BeijingCORONAScienceandTechnologyCo.,Ltd

InstituteofElectricalEngineeringofChineseAcademyofScience

HuadianNewEnergyDevelopmentCo.,Ltd

ChinaHuadianElectricPowerResearchInstitute

GezhoubaGroup'sElectricPowerCo.Ltd

SuntechPowerHoldingsCo.,Ltd

LDKSolar

GS-SOLAR(Fujian)Co.,Ltd

ChiefDraftingStaff:

XieJianningXuYongbangXuHonghuaShiYuewenGaohui

WangWenpingYaoWeixingGuHuaminZhuWeigangWuShaohuaShaoJiLiuQingchaoZhangQingyuanGaoPengfeiYuYun

·2·

LiChunLiuLiminLengJiguoWangShengliLiangZhe

HuangChuanzhongZhangLinglingWangZhiwei

ChiefReviewingStaff:

GuoJiabaoWangYiLiChunshanChenXiYiChuanbaoRenYuqing

YaoMinchengLiBinWangHongboShiSiqiangWuFubaoChenMoziLuZhigangZhuGengfuYanYutingWangLiJiaYangangLvPingyangSunYaojieYangWeiboLiYangZhangYouquanWuJie

Contents

1GeneralProvisions (1)

2Terms (2)

3BasicRequirements (3)

4AcceptanceofUnitProject (6)

4.1GeneralRequirements (6)

4.2CivilWorks (7)

4.3Installation (8)

4.4Planting (11)

4.5SecurityandProtection (11)

4.6FirePreventionandProtection (12)

5AcceptanceforProjectStart-up (13)

5.1GeneralRequirements (13)

5.2AcceptanceforStart-up (13)

6AcceptanceforCommissioningandTransfertoProduction (15)

6.1GeneralRequirements (15)

6.2AcceptanceforCommissioningandTransfertoProduction (15)

7FinalAcceptance (17)

AppendixADocumentstobeSubmittedinAcceptance (19)

AppendixBReferenceDocumentstobeProvidedinAcceptances (20)

AppendixCAcceptanceCertificateforUnitProjects (22)

AppendixDAcceptanceCertificateforStart-up (26)

AppendixEAcceptanceCertificateforCommissioningandTransfertoProduction (30)

AppendixFAcceptanceCertificateforCompletion (34)

ListofQuotedStandards (38)

·1·

1GeneralProvisions

1.0.1Thiscodeisformulatedtoassurethequalityofandprovideguidanceandnormsfortheacceptanceofphotovoltaicpowerprojects.

1.0.2Thiscodeisapplicabletotheacceptanceofnew,modifiedandexpandedgroundahdrooftopphotovoltaicpowerprojectsconnectedtopowergridwithanratedvoltageof380Vorabove,itisnotapplicabletoBIPV(BuildingIntegratedPhotovoltaic)andhouseholdPVprojects.

1.0.3PhotovoltaicpowerprojectsshallbesubjectedtocomprehensiveacceptancecheckthatisdividedintofourstagesincludingUnitProject,projectStart-up,CommissioningandTransfertoProduction,andprojectcompletion.

1.0.4Appropriateacceptanceorganizationshallbeestablishedasperrequirementforeachstageacceptance,andaleadingunitshallbedeterminedforsuchanorganization.

1.0.5Besidesthiscode,theacceptanceofphotovoltaicpowerprojectsshallcomplywithothercurrentnationalstandards.

·2·

2Terms

2.0.1Photovoltaicpowerproject

Photovoltaic(PV)powerprojectisphysicalengineeringthatconvertssolarenergyintoelectricityusingPVmodulesandiselectricallyconnectedtopublicpowergrids.APVpowerprojectconsistsofPVmodules,inverters,electriclines,monitoring/controlsystem,andbuildings(structures).

2.0.2Photovoltaicpowerstation

APVpowerstationisapowerplantthatconvertssolarenergyintoelectricitythroughPVmodulesandsupplieselectricpowertopublicpowergridsatthecommandofgriddispatchingdepartment.ItconsistsofprimaryequipmentsuchasPVmodules,inverters,electriclines,switches,transformersandreactivepowercompensationdevices,andsecondaryequipmentsuchasrelayprotection,in-stationmonitoring/controldispatchingautomationandcommunications.

2.0.3Photovoltaicpowerunit

InaPVpowerstation,acertainnumberofPVmodulestringsareconnectedtoacombinerbox,fromwhichpowerisinvertedbyaninverterandthen,boostedbyanisolatedstep-uptransformertotherequiredfrequencyandvoltageofthegrid.ThesecollectivePVstringsarecalledaPVpowerunit.

2.0.4Qualityofappearance

Theexteriorqualityofaprojectdeterminedthroughobservationsandnecessarymeasurements.

2.0.5Planting

Plantingoftrees,flowers,lawn,vegetation,etc.

2.0.6Securityandprotection

Anengineeringthatisimplementedbycomprehensiveuseofsecurityandpreventiontechnologiesandothertechnologiestoestablishasystemwithfunctionsofanti-intrusion,anti-theft,anti-damage,anti-robbingandexplosion-proof(ortheircombination)forthepurposeofensuringpowerstationsecurityandpreventingmajoraccidents.

·3·

3BasicRequirements

3.0.1Projectacceptanceshallbebasedonthefollowing:

1Currentapplicablenationallaws,regulations,rules,andtechnicalstandards.

2Provisionsofauthoritiesconcerned.

3Projectapprovaldocumentsandapprovedadjustedestimates.

4Approveddesigndocuments,constructiondrawings,andrelateddocumentsofengineeringchanges.

3.0.2Projectacceptanceitemsshallincludebutnotlimitedto:

1Checkwhethertheworksareconstructedtotheapproveddesign.

2Checkthequality-relateddocumentationofcompletedworksincludingdatacollection,sorting,filingintheprocessofdesign,construction,equipmentmanufacturingandinstallation.

3Checksafetymanagementinconstruction.

4Checkifthenecessaryconditionsareavailableforputtingintooperationorproceedingtothenextstage.

5Checkprojectinvestmentcontrolandtheusagesofthefunds.

6Presentsolutionstoremainingproblemsidentifiedinacceptance.

7Makeassessmentofandconclusionsonproject.

3.0.3Theconclusiononacceptanceshallbesubmittedtoacceptancecommittee(workgroup)forreviewandapproval.

3.0.4Acceptanceshallbedulyorganizedwhenconditionsforprojectacceptancearesatisfied.Worksthatarenotsubjectedtoorfailacceptanceshallnotbehandedoverforproductionorproceedtofollow-upconstruction.Acceptanceworkshallbeinterconnectedwithoutoverlap.

3.0.5TheresponsibilityforacceptanceofUnitProject,Start-up,CommissioningandTransfertoProduction,andFinalAcceptanceiswithanacceptanceteamorcommitteerespectivelyestablishedforsuchpurpose.

3.0.6Theacceptancedatashallbecollectedandsortedoutanddulysubmittedasperrequirementsbyconstructionunitsconcernedwhichshallcheckthecompletenessandformatofsubmitteddada.

3.0.7Acceptancedocumentsareclassifiedintosubmittedfilesandilesforfuturereference.Theorganizationsconcernedshallguaranteeandaccountforauthenticityofthesubmittals.RefertoAppendixAandAppendixBtothisstandardforlistofacceptancedocuments.

3.0.8Responsibilitiesofthepartiesinvolvedinprojectacceptancearedefinedasfollows:

1TheOwnershall:

1)Organizeandco-ordinateacceptanceworkateachstageandtakechargeofmanagerialworkinprocessofacceptance.

2)Takepartincheckandco-ordinationofspecializedteamsateachstage.

3)Coordinatetoresolveproblemsarisingfromexecutionofthecontractduringacceptance.

4)Provideasummaryreportonprojectconstruction.

·4·

5)Providereportsforcompletionacceptanceconcerningprojectcompletion,executionoftheestimates,projectsettlement,andimplementationoftheplansforsoilandwaterconservationandenvironmentalprotection.

6)Workwithrelatedorganizationstodofinalsettlementandaudit.

2Thesurveyoranddesignershall:

1)Verifyconstructionrecordsconcerningcivilandfoundationworks.

2)Solvetechnicalproblemsindesignandmakenecessarychangestothedesign.

3)Beresponsiblefortheprojectdesignconceptandqualityandpresentafinalreport'onprojectdesignforthepurposeofacceptance.

3TheContractorshall:

1)Provideacompletesetofconstructionrecords,testrecords,andaconstructionsummary.

2)Collectandprovideacompletesetofequipmentpackingdocumentsanddrawings.

3)Participateintheacceptanceateachstageandundertaketocorrectdefects.

4)Co-operatewiththeOwnerinjobsconcerningsitesafety,firefighting,guarding,andmaintenanceandrepairbeforeacceptanceofUnitProject,forstart-up,commissioningandtransfertoproduction.

5)Submitthecompletiondocumentsandhandoverspareparts,specialtools,andinstrumentsasrequiredbytheconstructionmanagingorganization.

4Thecommissioningorganizationshall:

1)Prepareacommissioningprogramandastart-upplan.

2)Comprehensivelycheckthesystemconditionsbeforecommissioningandassurethesafetymeasuresmeettherequirementsinthecommissioningplan.

3)Providetechnicalanalysisofproblemsfoundduringcommissioningandsolutions.

4)Submitacompletesetofrecordofequipmentcommissioning,commissioningreportandsummary,andconfirmwhetherstart-upcanbeperformed.

5Thesupervisingorganizationshall:

1)OrganizeacceptanceoftheitemprojectsandthePartProjects.

2)Evaluateprojectqualityaccordingtothedesignandrelatedacceptancespecifications.

3)Superviseandmanagethequality,safety,andprogressofprojectstart-up.

4)Participateindiscussionsonstart-upcommissioningprogram,measures,planandprocedures,andinacceptanceandsigningofprojectstart-upcommissioning.

5)Checkandconfirmwhetherconditionsforstart-uparemet,andurgetheContractorstocompleteallthejobsnecessaryforstart-up.

6TheOperatorshall:

1)ParticipateinacceptanceonStart-up,CommissioningandTransfertoProduction,andcompletion.

2)Participateinthepreparationofacceptanceprogramandacceptancesigningoff.

3)Participateinthereviewofthestat-upcommissioningplan.

4)Printrulesandregulations,systemcharts,recordtablesforproductionandoperation.

5)Preparesparepartsandsafetyappliance.

6)Checktheequipmentinoperationhavedesignationsandnumbersfordispatchingand

·5·

completeandcorrectmarkings,andsubmitanapplicationforthecommissioningofnewequipmenttothedispatchingdepartment.

7Theequipmentmanufacturersshall:

1)Providetechnicalsupportandinstructions.

2)Dulyremovemanufacturedefectsandsolveproblemsintheircharge.

·6·

4AcceptanceofUnitProject

4.1GeneralRequirements

4.1.1UnitProjectisclassifiedintofivemajorcategories:civilworks,installation,planting,securityandprotection,andfirepreventionandprotection.

4.1.2EachUnitProjectconsistsofseveralPartProjects.AcceptanceofUnitProjectshallbeorganizedbytheOwnerafterthePartProjectsarequalifiedthroughacceptance,

4.1.3PartProjectconsistsofseveralItemProjects.AcceptanceofPartProjectsshallbeorganizedbythechiefsupervisoryengineeraftertheItemProjectsarequalifiedthroughacceptance.

4.1.4AcceptanceofItemProjectsshallbeorganizedbythesupervisingengineerafterContractorhasqualifieditselfthroughcheckandevaluation.

4.1.5AcceptanceofUnitProjectshallmeetthefollowingrequirements:

1Qualitycontroldocumentationiscomplete.

2ThecheckdataonsafetyandfunctionalityofPartProjectsofaUnitProjectarecomplete.

3Spotcheckresultsofmajorfunctionsshallcomplywithappropriatetechnicalrequirements.

4Appearancequalitymeetstheacceptancerequirements.

4.1.6CompositionandmainresponsibilitiesoflUnitProjectacceptanceteam:

1TheUnitProjectacceptanceteamisestablishedbytheOwnerandcomposedofchiefsfrominterestedpartiesincludingtheQwner,thedesigningorganization,thesupervisor,theContractor(s),andthecommissioningorganization,andspecializedtechnicalpersonnel.

2TheUnitProjectacceptanceteamshall:

1)CommandandcoordinateinspectionsandacceptanceofPartProjects,ItemProjects,allstagesofconstructionandinstallationinallspecialties.

2)DulyorganizeorganizationsconcernedandspecializedpersonneltoformacceptanceteamsforPartProjectsandItemProjectsaccordingtotheworkprogress.

3)ListentotheoralreportpresentedbyContractorsonprojectconstructionandqualityevaluation.

4)Putforwardproposalsfordefectsfoundduringinspectionsandoverseeconcernedorganizationstocorrectthedefectswithinagiventimelimit.

5)ProvideoverallassessmentofUnitProject,andsign"LetterofAcceptanceofUnitProject"RefertoAppendixC.

4.1.7UponcompletionofUnitProject,theContractorshalldulyapplytotheOwnerforacceptance.TheUnitProjectacceptanceteamshalldulyestablishspecializedacceptanceteamstoperformacceptance.

4.1.8AcceptanceofUnitProjectshall:

1CheckwhethertheUnitProjectcomplieswiththeapproveddesigndrawings,designchangenotice(s)andtechnicalrequirementsforconstruction.

2Checkconstructionrecordsandmaterialcertificatesandinspectionreports.

3Checkinspectionrecordsandreportsfromthesupervisorofmajorprocessesandconcealed

·7·

works.

4ChecktheappearanceandoverallqualityoftheUnitProjectagainsttheacceptancerequirements.

5Providesolutionstoproblemsfoundduringtheinspection.

6QualityevaluationoftheUnitProject.

7Sign"LetterofAcceptanceofUnitProject".

4.1.9AcceptanceofPartProjectsshallmeetthefollowingrequirement:

1Documentsrelatingtoqualitycontrolarecomplete.

2InspectionresultsandsamplesofthesafetyandfunctionsoftheItemProjectsunderthePartProjectsshallmeetrelatedrequirements.

3Appearancequalitymeetsrequirements.

4.2CivilWorks

4.2.1AcceptanceofcivilworksincludesthatofPartProjectssuchassupportfoundationofPVmodules,fieldandundergroundfacilities,andstructures.

4.2.2Constructionrecords,acceptancedocumentsofconcealedworks,documentsofqualitycontrol,andrecordsofselfinspectionandacceptanceshallbecomplete.

4.2.3ThesupportfoundationofPVmodulesshallmeetthefollowingrequirements:

1Single(strip)concretefoundationshallcomplywiththecurrentnationalstandardCodeforAcceptanceofConstructionalQualityofConcreteStructuresGB50204.

2PilefoundationshallcomplywiththecurrentnationalstandardCodeforAcceptanceofConstructionQualityofBuildingFoundationGB50202.

3Exposedbuilt-inmetalparts(built-inbolts)shallbeprotectedagainstcorrosion.

4Theseatforroofsupport'shallbeconstructedinsuchawayasnottocausedamagetothemainstructureofthebuildingandthewaterprooffunctionoftheroof.Theseatshallbefirmlyandreliablyconnectedtothebearingstructuresofthebuilding.

5Tolerancesofaxislines,elevation,crosssectionandverticalityofthesupportfoundationandtolerancesofthesizesofbuilt-inbolts(parts)shallcomplywiththecurrentnationalstandardCodeforConstructionofPVPowerStationGB50794.

4.2.4Fieldandundergroundfacilitiesshallmeetthefollowingrequirements:

1Thesitelevelingshallmeettherequirementinthedesign.

2Roadsshallmeetthedesignrequirements.

3Cabletrenchshallmeetthedesignrequirements.Thetrenchshallbefreeofforeignmaterials,andshallbeequippedwithcompletecoversandsealinganddrainagefacilities.

4Watersupplyanddrainagefacilitiesshallmeetthedesignrequirements.

4.2.5AcceptanceofItemProjectssuchasinverterroom,switchroom,complex,masterbuilding,step-upsubstation,fence/wallofthebuildings(structures)shallcomplywiththecurrentnationalstandardsUnifiedStandardforConstructionalQualityAcceptanceofBuildingEngineeringGB50300,andCodeforAcceptanceofConstructionQualityofSteelStructuresGB50205,aswellasrelevantdesignrequirements.

·8·

4.3Installation

4.3.1AcceptanceofinstallationincludesuchPartProjectsassupports,PVmodules,combinerbox,inverter,electricalequipment,lightningprotectionandgrounding,electriclinesandcables.

4.3.2Completeproductmanuals,testrecords,certificates,installationdrawings,sparepartsandspecialtoolsandrelatedlists.

4.3.3Completedocumentssuchasrecordsandreportofequipmentsampling,installationandstart-up,signedrecordsofkeyproceduresduringconstruction,andrecordsofqualitycontrolandselfinspectionandacceptance.

4.3.4Installationofsupportsshallmeetthefollowingrequirements:

1Installationoffixedsupportsshallmeetthefollowingrequirements:

1)InstallationoffixedsupportsshallcomplywiththecurrentnationalstandardCodeforAcceptanceofConstructionQualityofSteelStructuresGB50205.

2)Forsupportsusingfasteners,thefasteningportionsofshallbefirmandsoundwithspringwasherbeingpressedflat.

3)Supportsshallbeerectedtothevertieality,levelness,andangletolerancespecifiedinthecurrentnationalstandardCodeforConstructionofPVPowerStationGB50794.

4)TolerancesfortheinstallationoffixedsupportsshallcomplywiththecurrentnationalstandardCodeforConstructionofPVPowerStationGB50794.

5)Manuallyadjustablesupportsshallhavetheelevationangleadjustmenttothedesignrequirements.

6)Corrosionprotectionoffixedsupportsshallmeetthedesignrequirements.

7)SupportsofmetalstructuresshallbereliablyconnectedtothegroundingsystemofPVarrays.

2Installationoftrackingsupportsshallmeetthefollowingrequirements:

1)InstallationoftrackingsupportsshallcomplywiththecurrentnationalstandardCodeforAcceptanceofConstructionQualityofSteelStructuresGB50205.

2)Fastenersofsupportsshallbefirmlyfastenedwithoutunevenspringwasher.

3)Whenthetrackingsupportissettoworkinmanualmode,themanualmovementshallmeetthedesignrequirements.

4)Whenthetrackingsupporthasamanualoperationmodewithlimits,themanualmovementshallmeetthedesignrequirements.

5)Movementinautomaticmodeshallmeetthedesignrequirements.

6)Highwindprotectionshallmeetthedesignrequirements.

7)Energizing/De-energizingtestingshallmeetthedesignrequirements.

8)Trackingprecisionshallmeetthedesignrequirements.

9)Thetrackingcontrolsystemshallmeetthetechnicalrequirements.

4.3.5InstallationofPVmodulesshallmeetthefollowingrequirements:

1InstallationofPVmodulesshallmeetthefollowingrequirements:

1)PVmodulesshallbeinstalledtothedesigndrawings,andthenumberofconnectionsandtheroutesshallmeetthedesignrequirements.

2)AppearanceofPVmodulesandterminalboxesandconnectorsshallnotshowanydamage.

·9·

3)ConnectorsbetweenPVmodulesshallbefirmlyconnected,andtheconnectingwiresshallbetreatedtohaveaneatandgood-lookingappearance.

4)TheinclinationangleforinstallationofPVmodulesshallcomplywiththecurrentnationalstandardCodeforConstructionofPVPowerStationGB50794.

5)DifferenceintheheightofPVmodulesshallcomplywiththecurrentnationalstandardCodeforConstructionofPVPowerStationGB50794.

6)TheinsulationresistanceofPVarraysshallmeetthedesignrequirements.

2Wiringshallmeetthefollowingrequirements:

1)PVmodulestringsshallbeconnectedinparallelorseriestothedesignrequirements.

2)MarkingofPVmodulestringsshallmeetthedesignrequirements.

3)Theopen-circuitvoltageandtheshort-circuitcurrentofPVmodulestringsshallcomplywith

thecurrentnationalstandardCodeforConstructionofPVPowerStationGB50794.

4.3.6Installationofcombinerboxesshallmeetthefollowingrequirements:

1Theinstallationpositionoftheboxbodyshallmeettherequirementsonthedesigndrawings.

2Thecombinerboxshallbecompletelymarked.

3Theboxbodyandthesupportshallbefirmlyconnected.

4Combinerboxeswithametalbodyshallbereliablygrounded.

5Heightandlevelnessofinstallationshallmeetthedesignrequirement.

4.3.7Installationofinvertersshallmeetthefollowingrequirements:

1Theappearanceoftheequipmentanditsmainpartsandcomponentsshallnothaveanydamageanddamp,andloosenedormissingcomponentsarenotallowed.

2Reviewcommissioningrecordsanddocuments.

3Thelabeloftheequipmentshallcarrytherequiredinformation,includingloadconnectionpointsandtheirpolarity.

4Invertersshallbereliablygrounded.

5InterfaceattheACsideoftheinvertershallbeinsulated.

6Allinsulationandswitchesshallfunctionnormally.

7Thecoolingfanshallworknormally.

8Inverterventilationshallmeetthedesignrequirements.

9Invertersshallbefirmlyandreliablyconnectedtothefoundation.

10Installationofsuspendedinvertersshallalsomeetthefollowingrequirements:

1)Invertersshallbefirmlyandreliablyconnectedtosupports.

2)Installationheightshallmeetthedesignrequirements.

3)Levelnessshallmeetthedesignrequirements.

4.3.8Installationofelectricalequipmentshallmeetthefollowingrequirements:

1InstallationoftransformersandmutualinductorsshallcomplywiththecurrentnationalstandardCodeforConstructionandAcceptanceofPowerTransformers,OilReactorsandMutualInductors-ElectricalEquipmentInstallationEngineeringGB50148.

2Installationofhigh-voltageelectricalequipmentshallcomplywiththecurrentnationalstandardCodeforConstructionandAcceptanceofHigh-VoltageElectricalAppliances-ElectricalEquipmentInstallationEngineeringGB50147.

3Installationoflow-voltageelectricalequipmentshallcomplywiththecurrentnationalstandard

·10·

CodeforConstructionandAcceptanceofLow-VoltageElectricalAppliances-ElectricalEquipmentInstallationEngineeringGB50254.

4Wiringofswitchboards,cabinetsandsecondarycircuitsshallcomplywiththecurrentnationalstandardCodeforConstructionandAcceptanceofSwitchboard,CabinetandSecondaryCircuit-ElectricalEquipmentInstallationEngineeringGB50171.

5InstallationofthemonitoringsystemofPVpowerstationsshallmeetthefollowingrequirements:

1)Completedocumentsaboutcablelayingroutes.

2)Cablesizesandtypesshallmeetthedesignrequirements.Cablesshallbeorderlyarrangedinanaestheticwaywithoutexternaldamage.Cablesboundtogethershallbeclosetoeachothertoformaneatandflatappearance.Strainrelievesshallbeevenlyplacedandproperlyset.

3)Thesignaltransmissionmodeshallmatchthetransmissiondistanceforthesignalline.Thetransmissionqualityshallmeetthedesignrequirements.

4)Signallineshallbelaidseparatelyfrompowerlinesandreliablygrounded.

5)Sensorsandtransducersshallbeinstalledwhereaccuratemeasurementscanbetakenwithoutimpactofotherfactors.

6)Themonitoringandcontrollingsoftwareshallhavethefunctionalitytothedesignrequirements.

7)Themonitoringandcontrollingsoftwareshallsupportstandardinterfaces.Theprotocoloftheinterfaceshallmeettherequirementsloftheupstreammonitoringandcontrollingsystemandtherequirementsondispatching.

8)Anyfaultofthemonitoringandcontrollingsoftwareshallnotimpactnormalfunctionoftheequipmentundermonitoring.

9)Ainsulationtestingreportasperrelatedstandardshallbeprovidedforallliveequipment.

6RelayprotectionandautomaticsafetydevicesshallcomplywiththecurrentnationalstandardTechnicalCodeforRelayingProtectionandSecurityAutomaticEquipmentGB/T14285.

7AutomateddispatchingsystemshallcomplywiththecurrentprofessionalstandardSpecificationsforTheDesignofDispatchingAutomationinElectricPowerSystemsDL/T5003andrelatedrequirementsonsafetyandprotectionforsecondarypowersystems.

8InstallationofdevicesforreactivecompensationshallcomplywiththecurrentnationalstandardCodeforConstructionandAcceptanceofHigh-VoltageElectricalAppliances-ElectricalEquipmentInstallationEngineeringGB50147.

9DispatchingcommunicationsystemshallcomplywiththecurrentindustrystandardsRulesofManagementofCommunicationinElectricPowerSystemDL/T544andTechnicalSpecificationsforAutomaticExchang

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论