.1.2斜截面受剪承载力计算根据“强剪弱弯”原则,需对框架梁剪力进行调整,结果如表6-2所示。跨净跨ln(m)gk+0.5qk(kN)VGb(kN)组合内力VAB5.822.2677.46185.0069.4945.51127.5299.13164.83BC2.210.6914.1175.6364.5163.9384.4364.7475.90CD5.822.2677.46164.7799.2345.52127.5369.54184.88(1)框架梁受剪截面AB、CD梁跨高比:l0/h=6300/600=10.5>2.5,γRE=1/0.85×0.2×1.0×14.3×250×560=471.1kN,满足要求。BC梁跨高比:l0/h=2.7/0.4=6.75>2.5,=302.8kN,满足要求。框架梁斜截面受剪配筋计算如表6-3所示。AB、BC、CD梁端箍筋的最大间距:{8d,1/4hb

项目AB梁BC梁CD梁V(kN)127.5284.43127.53h0(mm)560360560376.85242.26376.8567.2743.2467.270.150.160.151441001441001001002A8@1002A8@1002A8@1009006009002A8@2002A8@2002A8@200(2)梁端箍筋加密区长度AB和CD梁:l={1.5h,500}max={1.5×600,500}=900mmBC梁:l={1.5h,500}max={1.5×400,500}=600mm箍筋最小直径:d=8mm。(3)箍筋最大间距AB和CD梁:sb={hBC梁:sb={hb/4,8d,150}min={4加密区箍筋配置为:选双支箍2A8@100。复合最小配筋率:ρsv=Asv/(4)非加密区箍筋的间距AB和CD梁:取s=200mm<2sBC梁:取s=200mm<2s箍筋梁配箍筋示意图如图6-2所示。

6.1.3框架梁纵筋的锚固长度三级抗震框架纵筋的锚固长度为:laE6.2框架柱截面设计6.2.1轴压比验算轴压比验算如表6-4所示,从计算结果看均满足规范要求。

层柱Nmax(kN)Hn(m)λ=Hn/2h0Nmax/fcbhγRE6A317.92.70.850.0890.75B397.270.111C397.240.111D317.910.0895A641.290.1790.80B822.010.230C810.060.227D629.940.1764A965.070.270B1247.510.349C1223.630.342D942.370.2643A1289.000.361B1673.480.468C1673.650.468D1254.940.3512A1613.100.451B2100.260.587C2052.500.574D1597.690.4471A1948.493.950.545B2539.670.710C2480.020.694D1891.710.529

6.2.2框架柱正截面承载力计算柱的同一截面分别承受正反向弯矩,故采用对称配筋。计算结果如表6-5、6-6所示。轴线柱上端(kN·m)柱下端(kN·m)梁端弯矩(kN·m)梁左弯矩×1.3(kN·m)调整后柱上端(kN·m)调整后柱下端(kN·m)A轴四层62.60147.75185.00240.50071.57168.93三层92.76167.25231.05300.365107.16193.21二层111.14178.11245.55319.215122.65196.56一层148.33116.94235.83306.579171.43135.15D轴四层63.18148.33184.88240.34471.79168.55三层93.34167.83230.92300.196107.29192.91二层111.72178.70245.44319.072122.74196.33一层149.04175.53235.62306.306140.65165.65轴线柱上端(kN·m)柱下端(kN·m)梁左端弯矩(kN·m)梁右端弯矩(kN·m)(梁左+梁右)×1.3(kN·m)调整后柱上端(kN·m)调整后柱下端(kN·m)B轴四层96.04161.06164.8364.74298.44111.48186.96三层136.14190.41202.2987.87377.21157.26219.95二层159.95211.53227.15102.83428.97184.71244.27一层181.32205.24236.40107.93447.63209.97237.66C轴四层96.54161.5764.51164.77298.06111.48186.58三层136.65190.9187.65202.22376.83157.20219.63二层160.45212.05102.61227.09428.61184.62243.99一层181.92205.53107.66236.29447.14209.94237.19三级框架结构的底层,柱下端截面组合的弯矩设计值,应乘以增大系数1.3,如图6-3所示。

底层柱l0=1.0H,其余各层柱lh0NbN≤Nb时为大偏心受压破坏,N>Ne0=M构件端界面偏心距调整系数Cm=0.7+0.3M1/M2,当小于0.7时,取0.7。截面曲率修正系数,当计算值大于1.0时取1.0。故,当小于1.0时,取1.0由得,且柱截面纵向钢筋的最小总配筋率为0.85%,柱总配筋率不应大于5%。0.85%bh=0.85%×500×500=1875≤+<5%bh=5%×500×500=12500且As,minA垂直于受力平面内的配筋根据构造要求,每侧实配4C18。框架柱正截面承载力计算如表6-7、6-8、6-9。郑州市外国语中学6#办公楼设计柱层l(m)l截面一般组合地震组合内力组合内力考虑二阶效应影响e

(mm)e'

(mm)N−Nb破坏类型大偏压x−2as'As=As',x<2as'As=As',x>2as'选用钢筋Mmax(kN·m)N(kN)Mmax(kN·m)N(kN)γREMmax(kN·m)γREN(kN)CmeeeeξcηnsCmηnsMA64.1258.25顶48.62273.51100.58235.6275.44176.720.81426.8720446.870.9711.051.0075.44656.87236.87<0大偏压0.054-55.282774C18底41.28317.935.62263.5426.72197.66554.1258.25顶44.78577.37127.3544.6995.48408.520.87233.7120253.710.5511.091.0095.48463.7143.71<0大偏压0.124-22.861184C18底42.9641.2971.57572.6157.26429.4644.1258.25顶48.97881.92168.93831.91135.14623.930.89203.0620223.060.4811.111.00133.31433.0613.06<0大偏压0.1907.26544C18底46.61912.16107.16859.8385.73644.8734.1258.25顶53.241186.71193.211120.27154.57840.200.89172.4720192.470.4211.131.00154.86402.47-17.53<0大偏压0.25537.51-974C18底49.591216.96122.651148.1998.12861.1424.1258.25顶58.321491.77196.561140.43157.25855.070.96172.3620192.360.4211.131.08170.15402.36-17.64<0大偏压2.60039.63-124C18底61.791522.01171.431429.35137.141072.0114.559.1顶49.661796.92153.151668.90122.521251.681.5491.7720111.770.2411.261.94667.73321.77-98.23<0大偏压0.38195.06-4204C18底54.951838.62429.201707.39343.361280.54

郑州市外国语中学6#办公楼设计6.2.3框架柱斜截面承载力计算(1)框架柱最不利剪力计算根据“强剪弱弯”原则,对最不利剪力进行调整,计算结果如表6-10。层柱Hn(m)6A100.5835.622.7065.58B95.2850.8970.38C95.451.2570.61D100.6836.0665.845A127.371.5795.75B131.91114.48118.63C132.47111.48117.46D127.9671.7996.184A168.93107.16132.93B186.96157.26165.74C186.58157.20165.52D168.55107.29132.813A193.21122.65152.08B219.95184.71194.84C219.63184.62194.64D192.91122.74151.982A196.56171.43177.18B244.27209.97218.71C243.99209.94218.56D196.33140.65162.251A135.15429.203.95185.74B237.66405.56211.69C237.19275.76168.82D165.65429.43195.85

(2)截面尺寸验算=(0.2×14.3×500×400)/0.85=773.88>Vmax=218.71均满足要求。(3)斜截面承载力计算由于柱的反弯点在层高范围内2.7÷2×0.46=2.93,取λ=3.0N=1276.99<0.3fcA=0.3×14.3×5002×10-3=1072.5,故取N=1072.2kN=1.05×1.43×500×460÷(1+3.0)+0.056×1072.5×103=146396<0.85×218.71×1000=185903.5取4支箍φ8,Asv=50.3mm2,s=200mm。柱端加密区:取s=100,选用4A8。非柱端加密区:s=200mm<15d=15×18=270mm,选用4A8。柱端加密区长度:l={h,Hn/6,500}max={500,2700/6,500}=500mm(4)验算体积配筋率轴压比μ=0.574,线性内插得λv=0.1074.l1=500-2×26=452mm,l2=500-2×26=452mmAcor=(500-2×28)×(500-2×28)=197136其配筋率为:加密区:ρsv=4×50.3×452+4×50.3×452/444×444×100=0.92%>=0.1074×16.7/270=0.66%>0.4%,满足要求。非加密区:ρsv=4×50.3×452+4×50.3×452/444×444×200=0.47%,满足要求。

7板的计算7.1材料选用C30混凝土,,钢筋,楼面板尺寸的计算板块B1计算:板块B2计算:B1、B2板块位置如图2-1所示,均按双向板计算理论进行计算。取t=100mm。7.2荷载计算(办公室)(走廊)7.3截面设计7.3.1弯矩计算按塑性理论计算,取1m宽板带作为计算单元。(1)边区格板B1板两端与梁整体连接时,计算跨度为板的净跨度取,采用分离式配筋。跨内及支座塑性铰线上的总弯矩为由于区格板B1四周与梁链接,内力折减系数为0.8,由得kN·m/mkN·m/mkN·m/mkN·m/m(2)中间区格板B2板的计算跨度净跨,即:采用分离式配筋。跨内及支座塑性铰线上的总弯矩为:由于区格板B2四周与梁连接,折减系数为0.8,由得kN·m/mkN·m/mkN·m/mkN·m/m7.3.2配筋计算假定钢筋直径为10,则截面有效高度可近似按计算钢筋截面面积。计算结果如表7-1所示。

截面m(kN·m)h0(mm)As(mm2)选配钢筋适配钢筋(mm2)跨中B1方向1.47710043C8@200251方向0.287909B2方向1.06810031方向0.1602905支座B1-B12.95410086B1-B20.57410017B2-B12.13610062B2-B20.32041009最小配筋率实配钢筋面积均满足要求。

8楼梯计算8.1设计资料本工程采用现浇钢筋混凝土板式楼梯,设计混凝土强度等级为C30,楼梯及平台板中采用HRB400级钢筋,平台梁纵向采用HRB400级钢筋。踏步宽300高150。活荷载标准值为3.5。计算6-7轴线第四层楼梯。楼梯平台布置图如图8-1所示。8.2梯段板设计梯段板跨度板厚楼梯斜板的倾角,根据踏步宽300,高150,有,,取1m宽板带为计算单元。

荷载计算恒荷载标准值:踏步板自重:踏步地砖面层:踏步水泥砂浆找平层:12mm厚水泥砂浆板底抹灰:活荷载标准值:恒荷载设计值:活荷载设计值:(2)内力计算(3)配筋计算板的有效高度:最小配筋率选配钢筋C8@100,As=503mm2,每级踏步下配一根A8的分布筋。满足抗剪要求。支座配钢筋C8@200。8.3平台板计算(PTB1)计算跨度:按单向板计算,取1m宽板带为计算单元,板厚为120mm。(1)荷载计算恒荷载标准值(与走廊楼面相同):活荷载标准值:恒荷载设计值:活荷载设计值:(2)内力计算(3)配筋计算选配钢筋C8@200,As=251mm2,分布钢筋为C8@300。8.4梁梯梁计算(TL1)a为平台梁在墙上的长度,a=200mm。(1)荷载计算梯段板传荷载:平台板传:梁自重:合计:32.03kN/m(2)内力计算(3)配筋计算配HRB400级钢筋,。最小配筋率选配钢筋2C18,As=509mm2。只需按构造配置钢筋,选配A8@200双肢箍筋。

9柱下独立基础9.1基本概况本办公楼采用柱下独立基础。基础顶面到室外地坪的距离为0.5m。基础混凝土强度等级为C30,9.2独立基础设计1.0m杂填土4.0m粉土(1)独基深度(2)地基承载力设计值(3)基础底面积(4)地基承载力验算偏心距:=237.52<1.2fa=1.2×241.56=289.872kPa(5)计算基底净反力(6)计算冲切力柱与基础交接处:。9.3基础配筋计算(1)基础长边方向阶梯一处:kN·m阶梯二处:

kN·m换算成每米宽度的钢筋截面积为530mm2,所以实配钢筋C12@180,,基础短边方向配筋和长边相同。

参考文献[1]中华人民共和国国家标准.混凝土结构设计规范(GB50010-2010)(2015年修订版)[S].北京:中国建筑工业出版社,2015.[2]中华人民共和国国家标准.建筑抗震设计规范(GB50010-2010)(2016年修订版)[S].北京:中国建筑工业出版社,2016.[3]中华人民共和国国家标准.建筑结构荷载规范(GB50009-2012)[S].北京:中国建筑工业出版社,2012.[4]中华人民共和国行业标准.办公楼建筑设计规范(JGJ36-2019)[S].北京:化学工业出版社,2016.[5]中华人民共和国行业标准.建筑设计防火规范(GB50016-2014)(2018年修订)[S].北京:中国计划出版社,2018.[6]中华人民共和国行业标准.建筑地基基设计规范(GB50016-2011)[S].北京:中国计划出版社,2011.[7]同济大学.

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论