ProductDataSheet00813-0100-4001,RevWBApril2021

Rosemount3051PressureTransmitter

WiththeRosemount3051PressureTransmitter,you'llgainmorecontroloveryourplant.You'llbeabletoreduceproductvariationandcomplexityaswellasyourtotalcostofownershipbyleveragingonedeviceacrossanumberofpressure,level,andflowapplications.You'llhaveaccesstoinformationyoucanusetodiagnose,correct,andevenpreventissues.Andwithunparalleledreliabilityandexperience,the

Rosemount3051istheindustrystandardthatwillhelpyouperformathigherlevelsofefficiencyandsafetysoyoucanremaingloballycompetitive.

ROSEMOUNTTMEMERSONTM

Rosemount3051April2021

Contents

Settingthestandardforpressuremeasurement 2

Rosemount3051CCoplanarPressureTransmitterorderinginformation 6

Rosemount3051TIn-LineTransmitterorderinginformation 19

Rosemount3051CFFlowMeterselectionguide 29

Rosemount3051LLevelTransmitterorderinginformation 61

Specifications 73

Rosemount3051productcertifications 91

Rosemount3051Wirelessproductcertifications 107

Dimensionaldrawings 112

Options 127

2E/Rosemount

April2021Rosemount3051

Settingthestandardforpressuremeasurement

Provenbest-in-classperformance,reliability,andsafety

.Morethansevenmillioninstalled

.Referenceaccuracy0.04percentofspan

.Installedtotalperformanceof0.14percentofspan

.10-yearstabilityof0.2percentofURL.SIL2/3certified(IEC61508)

Maximizeinstallationandapplicationflexibilitywiththecoplanarplatform

.ImprovereliabilityandperformancewithintegratedDPFlowmeters,DPLevelsolutions,andintegralmanifolds..Easyinstallationwithallsolutionsfullyassembled,leak-tested,andcalibrated.

.Meetyourapplicationneedswithanunsurpassedoffering.

Advancedfunctionality

LoopIntegritydiagnostics

.Detecton-scalefailurescausedbyelectricalloopissuesbeforetheyimpactyourprocessoperation.

.Thiscapabilityissafetycertifiedforyourmostcriticalapplications.

Localoperatorinterface(LOI)

.Straightforwardmenusandbuilt-inconfigurationbuttonsallowyoutocommissionthedeviceinlessthanaminute.

.Configureinhazardous-arealocationswithoutremovingthetransmittercoverusingexternalbuttons.

E/Rosemount3

Rosemount3051April2021

IndustryleadingcapabilitiesextendedtoIEC62591(WirelessHART®)

Innovative,integratedDPflowmeters

.Costeffectivelyimplementwirelessontheindustry'smostprovenplatform.

.Optimizesafetywiththeindustry'sonlyintrinsicallysafepowermodule.

.Eliminatewiringdesignandconstructioncomplexitiestolowercostsby40to60percent.

.Quicklydeploynewpressure,level,andflowmeasurementsin70percentlesstime.

.Fullyassembled,configured,andleaktestedforout-of-the-boxinstallation.

.Reducestraightpiperequirements,lowerpermanent

pressureloss,andachieveaccuratemeasurementinsmalllinesizes.

.Upto1.65percentvolumetricflowaccuracyat8:1turndown.

4E/Rosemount

April2021Rosemount3051

Proven,reliable,andinnovativeDPLeveltechnologies

.

.

.

.

Connecttovirtuallyanyprocesswithacomprehensive

offeringofprocessconnections,fillfluids,directmount,orcapillaryconnectionsandmaterials.

QuantifyandoptimizetotalsystemperformancewithQZoption.

Operateathighertemperatureandinvacuumapplications.

OptimizelevelmeasurementwithcostefficientRosemountTuned-System™assemblies.

Instrumentmanifolds–quality,convenient,andeasy

.DesignedandengineeredforoptimalperformancewithRosemounttransmitters.

.Saveinstallationtimeandmoneywithfactoryassembly..Offersavarietyofstyles,materials,andconfigurations.

Accessinformationwhenyouneeditwithassettags

NewlyshippeddevicesincludeauniqueQRcodeassettagthatenablesyoutoaccessserializedinformationdirectlyfromthedevice.Withthiscapability,youcan:

.Accessdevicedrawings,diagrams,technicaldocumentation,andtroubleshootinginformationinyourMyEmersonaccount.Improvemeantimetorepairandmaintainefficiency

.Ensureconfidencethatyouhavelocatedthecorrectdevice

.Eliminatethetime-consumingprocessoflocatingandtranscribingnameplatestoviewassetinformation

E/Rosemount5

Rosemount3051April2021

Rosemount3051CCoplanarPressureTransmitterorderinginformation

Rosemount3051CCoplanarPressureTransmittersarethe

industrystandardfordifferential,gage,andabsolutepressuremeasurement.Thecoplanarplatformenablesseamless

integrationwithmanifolds,flow,andlevelsolutions.

Capabilitiesinclude:

.TheLoopIntegrityDiagnosticcontinuouslymonitorstheelectricallooptodetectchangesthatcompromisethe

integrityofthetransmitted4-20mAoutputsignal(OptionCodeDA0).

.LOIwithstraightforwardmenusandbuilt-inconfiguration

buttons(optioncodeM4).

.Safetycertification(optioncodeQT).

CONFIGURE>

VIEWPRODUCT>

Onlineproductconfigurator

ManyproductsareconfigurableonlineusingourProductConfigurator.SelecttheConfigurebuttonorvisitour

website

tostart.Withthistool'sbuilt-inlogicandcontinuousvalidation,youcanconfigureyourproductsmorequicklyandaccurately.

Specificationsandoptions

SeetheSpecificationsandoptionssectionformoredetailsoneachconfiguration.Specificationandselectionofproductmaterials,options,orcomponentsmustbemadebythepurchaseroftheequipment.SeetheMaterialselectionsectionformoreinformation.

Modelcodes

Modelcodescontainthedetailsrelatedtoeachproduct.Exactmodelcodeswillvary;anexampleofatypicalmodelcodeisshownin

Figure1

.

Figure1:ModelCodeExample

1.Requiredmodelcomponents(choicesavailableonmost)

2.Additionaloptions(varietyoffeaturesandfunctionsthatmaybeaddedtoproducts)

Optimizingleadtime

Thestarredofferings(*)representthemostcommonoptionsandshouldbeselectedforbestdelivery.Thenon-starredofferingsaresubjecttoadditionaldeliveryleadtime.

6E/Rosemount

April2021Rosemount3051

Requiredmodelcomponents

Model

Code

Description

3051C

Coplanarpressuretransmitter

*

Measurementtype

Code

Description

D

Differential

*

G

Gage

*

A

(1)

Absolute

(1)IforderedwithWirelessoutputcodeX,onlyavailablewith316Lstainlesssteel(SST)diaphragmmaterial(code2),andsiliconefillfluid(code1).

Pressurerange

Code

Differential

(Rosemount3051CD)

Gage

(Rosemount3051CG)

Absolute

(Rosemount3051CA)

1

–25to25inH2O

(–62.16to62.16mbar)

–25to25inH2O

(–62.16to62.16mbar)

0to30psia

(0to2.06bar)

*

2

–250to250inH2O

(–621.60to621.60mbar)

–250to250inH2O

(–621.60to621.60mbar)

0to150psia

(0to10.34bar)

*

3

–1000to1000inH2O(–2.48to2.48bar)

–393to1000inH2O(–0.97to2.48bar)

0to800psia(0to55.15bar

*

4

–300to300psi

(–20.68to20.68bar)

–14.2to300psi

(–0.97to20.68bar)

0to4000psia

(0to275.79bar)

*

5

–2000to2000psi

(–137.89to137.89bar)

–14.2to2000psi

(–0.97to137.89bar)

N/A

*

0(1)

–3to3inH2O

(-7.46to7.46mbar)

N/A

N/A

(1)Rosemount3051CD0isonlyavailablewithoutputcodeAandX.ForoutputcodeA,onlytransmitterflangecode0(AlternateflangeH2,H7,HJ,orHK),isolatingdiaphragmcode2,OringcodeA,andboltingoptionL4areavailable.ForoutputcodeX,onlytransmitterflangecode0(AlternateflangeH2),isolatingdiaphragmcode2,OringcodeA,andboltingoptionL4areavailable.

Transmitteroutput

Code

Description

A

(1)

4–20mAwithdigitalsignalbasedonHART®Protocol

*

F

FOUNDATION™FieldbusProtocol

*

W(2)

PROFIBUS®PAProtocol

*

X

(3)

Wireless(requireswirelessoptionsandengineeredpolymerhousing)

*

E/Rosemount7

Rosemount3051April2021

M

(4)

Low-power,1–5VdcwithdigitalsignalbasedonHARTProtocol

(1)HARTRevision5isthedefaultHARToutput.

(2)Forlocaladdressingandconfiguration,M4(LOI)isrequired.NotavailablewithproductcertificationcodesE4,EM,EP,I6,IM,KD,KL,KM,KP,KS,N3.

(3)Thisoptionisonlyavailablewithintrinsicallysafeapprovals.

(4)OnlyavailablewithC6,E2,E5,I5,K5,KB,EM,EP,andE8productcertifications.

Materialsofconstruction

Code

Transmitterflangetype

Flangematerial

Drain/vent

2

Coplanar

SST

SST

*

3

(1)

Coplanar

CastC-276

AlloyC-276

*

4

Coplanar

Alloy400

Alloy400/K-500

*

5

Coplanar

PlatedCS

SST

*

7

(1)

Coplanar

SST

AlloyC-276

*

8(1)

Coplanar

PlatedCS

AlloyC-276

*

0

Alternateprocessconnection

*

(1)MaterialsofconstructioncomplywithrecommendationsperNACEMR0175/ISO15156forsouroilfieldproductionenvironments.Environmentallimitsapplytocertainmaterials.Consultlateststandardfordetails.SelectedmaterialsalsoconformtoNACEMR0103forsourrefining

environments.

Isolatingdiaphragm

Code

Description

2

(1)

316LSST

*

3

(1)

AlloyC-276

*

4(2)

Alloy400

5(2)

Tantalum(availableonRosemount3051CDandCG,ranges2–5only;notavailableonRosemount3051CA)

6

(2)

Gold-platedalloy400(useincombinationwithO-ringoptioncodeB)

7(2)

Gold-plated316SST

(1)MaterialsofconstructioncomplywithrecommendationsperNACEMR0175/ISO15156forsouroilfieldproductionenvironments.Environmentallimitsapplytocertainmaterials.Consultlateststandardfordetails.SelectedmaterialsalsoconformtoNACEMR0103forsourrefining

environments.

(2)Notavailablewithwirelessoutput(codeX).

O-ring

Code

Description

A

Glass-filledPTFE

*

B

Graphite-filledPTFE

*

Sensorfillfluid

Code

Description

1

Silicone

*

8E/Rosemount

April2021Rosemount3051

2

(1)

Inert(differentialandgageonly)

*

(1)Notavailablewithwirelessoutput(codeX).

Housingmaterial

Code

Description

Conduitentrysize

A

Aluminum

½–14NPT

*

B

Aluminum

M20x1.5

*

E

Aluminum,ultralowcopper

½–14NPT

*

F

Aluminum,ultralowcopper

M20x1.5

*

J

SST

½–14NPT

*

K

SST

M20x1.5

*

P

(1)

Engineeredpolymer

Noconduitentries

*

D

(2)

Aluminum

M(2)

SST

(1)Onlyavailablewithwirelessoutput(codeX).

(2)Transmitterconduitentrywillbe½NPTanda½NPTtoG½threadadapterwillbeprovided.ThisoptionisonlyavailablewithproductcertificationsoptionsI1,I2,I3,I7,IA,IB,IM,KA,N1,N3,N7.HousingcodeDisalsoavailablewithE4,andIG.

Wirelessoptions

RequireswirelessoutputcodeXandengineeredpolymerhousingcodeP.

Wirelesstransmitrate,operatingfrequency,andprotocol

Code

Description

WA3

Userconfigurabletransmitrate,2.4GHzWirelessHART®

*

AntennaandSmartPower™

Code

Description

WP5

Internalantenna,compatiblewithGreenPowerModule(I.S.PowerModulesoldseparately)

*

E/Rosemount9

Rosemount3051April2021

Additionaloptions

Extendedproductwarranty

Code

Description

WR3

3-yearlimitedwarranty

*

WR5

5-yearlimitedwarranty

*

Plantweb™controlfunctionality

Code

Description

A01

FOUNDATION™Fieldbuscontrolfunctionblocksuite

*

Plantweb™diagnosticfunctionality

Code

Description

DA0

LoopIntegrityHART®Diagnostic

*

D01

FOUNDATION™FieldbusDiagnosticsSuite

*

Alternateflange

Thealternateflangeoptioncoderequiresthe0codeinmaterialsofconstructionforalternateprocessconnection.

Code

Description

H2

Traditionalflange,316SST,SSTdrain/vent

*

H3

(1)

Traditionalflange,alloyC,alloyC-276drain/vent

*

H4

Traditionalflange,castalloy400,alloy400/K-500drain/vent

*

H7

(1)

Traditionalflange,316SST,alloyC-276drain/vent

*

HJ

DIN-complianttraditionalflange,SST,7/16-in.(10mm)adapter/manifoldbolting

*

FA

Levelflange,SST,2-in.(51mm),ANSIClass150,verticalmount316SSTdrain/vent

*

FB

Levelflange,SST,2-in.(51mm),ANSIClass300,verticalmount316SSTdrain/vent

*

FC

Levelflange,SST,3-in.(76mm),ANSIClass150,verticalmount316SSTdrain/vent

*

FD

Levelflange,SST,3-in.(76mm),ANSIClass300,verticalmount316SSTdrain/vent

*

FP

DINlevelflange,SST,DN50,PN40,verticalmount316SSTdrain/vent

*

FQ

DINlevelflange,SST,DN80,PN40,verticalmount316SSTdrain/vent

*

HK(2)

DINcomplianttraditionalflange,SST,0.40in.(10mm)adapter/manifoldbolting316SST

HL

DINcomplianttraditionalflange,SST,0.50in.(12mm)adapter/manifoldbolting316SST

(1)MaterialsofconstructioncomplywithrecommendationsperNACEMR0175/ISO15156forsouroilfieldproductionenvironments.Environmentallimitsapplytocertainmaterials.Consultlateststandardfordetails.SelectedmaterialsalsoconformtoNACEMR0103forsourrefining

environments.

(2)NotvalidwithoptioncodeP9for4500staticpressure.

10E/Rosemount

April2021Rosemount3051

Manifoldassembly

“Assemble-to”itemsarespecifiedseparatelyandrequireacompletedmodelnumber.

Code

Description

S5

AssembletoRosemount305IntegralManifold

*

S6

AssembletoRosemount304ManifoldorConnectionSystem

*

Integralmountprimaryelement

NotvalidwithoptioncodeP9for4500staticpressure.“Assemble-to”itemsarespecifiedseparatelyandrequireacompletedmodelnumber.

Code

Description

S3

AssembletoRosemount405CompactOrificePlate

*

S4

(1)

AssembletoRosemountAnnubar™orRosemount1195IntegralOrifice

*

(1)Transmitterflangelimitedtocoplanar(optioncodes2,3,5,7,or8)ortraditional(optioncodesH2,H3,orH7).

Sealassemblies

“Assemble-to”itemsarespecifiedseparatelyandrequireacompletedmodelnumber.

Code

Description

S1

(1)

AssembletooneRosemount1199seal

*

S2

(2)

AssembletotwoRosemount1199seals

*

(1)NotvalidwithoptioncodeD9forRC½adapters.

(2)NotvalidforoptioncodesDFandD9foradapters.

Mountingbracket

Panelmountingboltsarenotsupplied.

Code

Description

B4

Coplanarflangebracket,allSST,2-in.(51mm)pipeandpanel

*

B1

Traditionalflangebracket,CS,2-in.(51mm)pipe

*

B2

Traditionalflangebracket,CS,panel

*

B3

Traditionalflangeflatbracket,CS,2-in.(51mm)pipe

*

B7

Traditionalflangebracket,B1withSSTbolts

*

B8

Traditionalflangebracket,B2withSSTbolts

*

B9

Traditionalflangebracket,B3withSSTbolts

*

BA

Traditionalflangebracket,B1,allSST

*

BC

Traditionalflangebracket,B3,allSST

*

Productcertifications

Code

Description

E8

ATEXFlameproofandDustCertification

*

E/Rosemount11

Rosemount3051April2021

I1

(1)

ATEXIntrinsicSafetyandDust

*

IA

ATEXFISCOIntrinsicSafety;forFOUNDATION™FieldbusorPROFIBUS®PAProtocolonly

*

N1

ATEXTypenCertificationandDust

*

K8

ATEXFlameproof,IntrinsicSafety,Typen,Dust(combinationofE8,I1andN1)

*

E4

TIISFlame-proof

*

I4

TIISIntrinsicSafety

*

E5

USAExplosion-proof,DustIgnition-Proof

*

I5(2)

USAIntrinsicallySafe,Nonincendive

*

C6

CanadaExplosion-proof,DustIgnition-proof,IntrinsicallySafe,andDivision2

*

E6

CanadaExplosion-proof,DustIgnition-proof,Division2

*

I6

CanadaIntrinsicSafety

*

K6

CanadaandATEXExplosion-proof,IntrinsicallySafe,andDivision2(combinationofC6,E8,andI1)

*

E7

IECExFlameproof,DustIgnition-proof

*

I7

IECExIntrinsicSafety

*

N7

IECExTypenCertification

*

K7

IECExFlame-proof,DustIgnition-proof,IntrinsicSafety,andTypen(combinationofI7,N7,andE7)

*

IG

IECExFISCOIntrinsicallySafe;forFOUNDATIONFieldbusorPROFIBUSPAProtocolsonly

*

K5

USAExplosion-proof,DustIgnition-Proof,IntrinsicallySafe,andDivision2

*

E2

INMETROFlameproof001

*

I2

INMETROIntrinsicSafety

*

IB

INMETROFISCOintrinsicallysafe;forFOUNDATIONFieldbusorPROFIBUSPAProtocolsonly

*

K2

INMETROFlameproof,IntrinsicSafety

*

E3

ChinaFlameproof

*

I3

ChinaIntrinsicSafety

*

N3

ChinaTypen

*

EM

TechnicalRegulationsCustomsUnion(EAC)Flameproof

*

IM

TechnicalRegulationsCustomsUnion(EAC)IntrinsicSafety

*

KM

TechnicalRegulationsCustomsUnion(EAC)FlameproofandIntrinsicSafety

*

KB

USAandCanadaExplosion-proof,DustIgnitionProof,IntrinsicallySafe,andDivision2(combinationofK5andC6)

*

KD

USA,Canada,andATEXExplosion-proof,IntrinsicallySafe(combinationofK5,C6,I1,andE8)

*

KL(3)

USA,Canada,IECEx,ATEXIntrinsicSafetyCombination

*

KS

USA,Canada,IECEx,ATEXExplosionProof,IntrinsicallySafe,Dust,Non-Incendive,Type-N,Div.2

*

EP

RepublicofKoreaFlameproof

*

IP

RepublicofKoreaIntrinsicSafety

*

KP

RepublicofKoreaFlameproof,IntrinsicSafety

*

(1)DustapprovalnotapplicabletooutputcodeX.

(2)Nonincendivecertificationnotprovidedwithoutputcode(X).

(3)OnlyavailablewithoutputcodeX.

12E/Rosemount

April2021Rosemount3051

Drinkingwaterapproval

ThisapprovalisnotavailablewithAlloyC-276isolator(code3),tantalumisolator(code5),allcastC-276flanges,allplatedcarbonsteel(CS)flanges,allDINflanges,alllevelflanges,assemble-tomanifolds(codesS5andS6),assemble-toseals(codesS1andS2),assemble-toprimaryelements(codesS3andS4),surfacefinishcertification(codeQ16),andremotesealsystemreport(codeQZ).

Code

Description

DW

NSFdrinkingwaterapproval

*

Shipboardapprovals

Shipyardapprovalsarenotavailablewithwirelessoutput(codeX).

Code

Description

SBS

AmericanBureauofShipping

*

SBV

(1)

BureauVeritas(BV)

*

SDN

DetNorskeVeritas

*

SLL

(1)

LloydsRegister(LR)

*

(1)OnlyavailablewithproductcertificationsE7,E8,I1,I7,IA,K7,K8,KD,N1,N7

SSTtagging

Code

Description

Y2

316SSTnameplate,toptag,wire-ontag,andfasteners

Custodytransfer

ThecustodytransferoptionisonlyavailablewithHART4–20mAoutput(codeA).

Code

Description

C5

MeasurementCanadaAccuracyApproval(limitedavailabilitydependingontransmittertypeandrange;contactanEmersonrepresentative).

*

Boltingmaterial

Code

Description

L4

(1)

Austenitic316SSTbolts

*

L5

ASTMA193,gradeB7Mbolts

*

L6

AlloyK-500bolts

*

(1)L4boltingnotrequiredwithS6option.

E/Rosemount13

Rosemount3051April2021

Displayandinterfaceoptions

Code

Description

M4

(1)

LCDdisplaywithLOI

*

M5

LCDdisplay

*

(1)Onlyavailablewith4-20mAHART®output(codeA)andPROFIBUS®-PA(codeW).

Calibrationcertificate

Code

Description

Q4

Calibrationcertificate

*

QG

(1)

CalibrationcertificateandGOSTverificationcertificate

*

QP

Calibrationcertificationandtamperevidentseal

*

(1)ContactanEmersonrepresentativeforavailability.

Materialtraceabilitycertification

Code

Description

Q8

MaterialtraceabilitycertificationperEN102043.1

*

Positivematerialidentification(PMI)

Code

Description

Q76

PMIverificationandcertificate

*

Qualitycertificationforsafety

ThequalitycertificationforsafetyisonlyavailablewithHART®4–20mAoutput(codeA).

Code

Description

QT

SafetycertifiedtoIEC61508withcertificateofFMEDA

*

Configurationbuttons

Code

Description

D4

(1)

Analogzeroandspan

*

DZ

(2)

Digitalzerotrim

*

(1)OnlyavailablewithHART®4–20mAoutput(codeA).

(2)OnlyavailablewithHART4–20mAoutput(outputcodeA)andwirelessoutput(outputcodeX)

14E/Rosemount

April2021Rosemount3051

Transientprotection

Thetransientprotectionoptionisnotavailablewithwirelessoutput(codeX).TheT1optionisnotneededwithFISCOProductCertifications;transientprotectionisincludedintheFISCOproductcertificationcodesIA,IB,andIE.

Code

Description

T1

Transientprotectionterminalblock

*

Softwareconfiguration

ThesoftwareconfigurationoptionisonlyavailablewithHART®4–20mAoutput(outputcodeA)andwirelessoutput(outputcodeX).

Code

Description

C1

Customsoftwareconfiguration(Forwired,seetheRosemount3051

ConfigurationDataSheet

.Forwireless,seetheRosemount3051Wireless

ConfigurationDataSheet

.)

*

Lowpoweroutput

Code

Description

C2

0.8–3.2VdcoutputwithdigitalsignalbasedonHARTProtocol(availablewithoutputcodeMonly)

*

Gaugepressurecalibration

Code

Description

C3

Gaugecalibration(Rosemount3051CAonly)

*

Alarmlevels

ThealarmlevelsoptionisonlyavailablewithHART4–20mAoutput(codeA).

Code

Description

C4

(1)

AnalogoutputlevelscompliantwithNAMURrecommendationNE43,alarmhigh

*

CN

(1)

AnalogoutputlevelscompliantwithNAMURrecommendationNE43,alarmlow

*

CR

Customalarmandsaturationsignallevels,highalarm(requiresC1andRosemount3051

ConfigurationDataSheet

)

*

CS

Customalarmandsaturationsignallevels,lowalarm(requiresC1andRosemount3051

ConfigurationDataSheet

)

*

CT

Rosemountstandardlowalarm

*

(1)NAMUR-compliantoperationispresetatthefactoryandcanbechangedtostandardoperationinthefieldforthestandardRosemount3051.

Pressuretesting

Code

Description

P1

Hydrostatictestingwithcertificate

E/Rosemount15

Rosemount3051April2021

Cleaningprocessarea

Code

Description

P2

Cleaningforspecialservice

P3

(1)

Cleaningfor<1ppmchlorine/fluorine

(1)NotavailablewithcodeS5.

Flangeadapters

ThisoptionisnotvalidwithalternateprocessconnectionoptionsS3,S4,S5,andS6.

Code

Description

DF

½–14NPTflangeadapter(s)

*

Ventdrainvalves

Code

Description

D7

Coplanarflangewithoutdrain/ventports

DC

Portsleftopen-None

Conduitplug

Theconduitplugoptionisnotavailablewithwirelessoutput(codeX).

Code

Description

DO

316SSTconduitplug

*

RC¼RC½processconnection

Thisoptionisnotavailablewithalternateprocessconnection,DINflanges,andlevelflanges.

Code

Description

D9

RC¼flangewithRC½flangeadapter-SST

Maximumstaticlinepressure

Code

Description

P9

4500psig(310,26bar)staticpressurelimit(Rosemount3051CDranges2–5only)

*

Groundscrew

Thegroundscrewoptionisnotavailablewithwirelessoutput(codeX).TheV5optionisnotneededwiththeT1option;externalgroundscrewassemblyisincludedwiththeT1option.

Code

Description

V5

Externalgroundscrewassembly

*

16E/Rosemount

April2021Rosemount3051

Surfacefinish

Code

Description

Q16

Surfacefinishcertificationforsanitaryremoteseals

*

Toolkittotalsystemperformancereports

Code

Description

QZ

Remotesealsystemperformancecalculationreport

*

Conduitelectricalconnector

Theconduitelectricalconnectoroptionisnotavailablewithwirelessoutput(codeX).

Code

Description

GE

M12,4-pin,maleconnector(eurofast®)

*

GM

Asizemini,4-pin,maleconnector(minifast®)

*

NACE

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论