1、Cable and Board Presence - Message Code: x1AxxMessage CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?E1A10PDBPwrCableHighPDB power cable to the planar is missing or bad and system will not power on.F

2、ailing device is reseated/replaced/repaired.YesPre-PostE1A11PCIRsrConfigHighPCI risers are not configured correctly; some invalid configurations prevent system power on.Failing device is reseated/replaced/repaired.YesPre-PostE1A12PCIRsrMissingHighOne or all of the PCI risers is missing. This prevent

3、s system power on.Failing device is reseated/replaced/repaired.YesPre-PostE1A14SAS Cable ALowSAS cable A is missing or bad.Failing device is reseated/replaced/repaired.YesAnyE1A15SAS Cable BLowSAS cable B is missing or bad.Failing device is reseated/replaced/repaired.YesAnyE1A16SAS Cable FBLowFlex b

4、ay SAS cable is missing or bad.Failing device is reseated/replaced/repaired.YesAnyE1A17PwrCable FBLowFlex bay power cable is missing or bad.Failing device is reseated/replaced/repaired.YesAnyE1A18PDBCtrl CableHighPDB control cable to the planar is missing or bad and system will not power on.Failing

5、device is reseated/replaced/repaired.YesAnyTemperature - Message Code: x11xxMessage CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?E1114Temp AmbientMedAmbient temperature has a reached a point outsid

6、e of the allowed range.Temperature returns to allowable range.YesAnyE1116Temp MemoryHighMemory has exceeded allowable temperature and has been disabled to prevent damage to the components.AC Cycle or SEL clearYesAnyVoltages - Message Code: x12xxMessage CodeMessage StringMessage PriorityMessage Comme

7、ntsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?E1210CMOSBattLowCMOS battery is missing or the voltage is outside of the allowable range.Failing device is reseated/replaced/repaired.YesAnyE1211ROMBBattLowPERC5I RAID battery charger has reported to

8、 the Server Management that the battery is either missing, cant charge the battery (possibly because of high temperatures), or the battery is bad.Failing device is reseated/replaced/repaired.YesAnyW1228ROMBBatt 24 hours of sustained charge.YesAnyE12141.5VPwrGdHigh1.5 VV voltage regulator has failed.

9、AC Cycle or SEL clearYesAnyE12151.8VPwrGdHigh1.8 VV voltage regulator has failed.AC Cycle or SEL clearYesAnyE12163.3VPwrGdHigh3.3 V voltage regulator has failed.AC Cycle or SEL clearYesAnyE12175VPwrGdHigh5 V voltage regulator has failed.AC Cycle or SEL clearYesAnyE1218PCIRsr5VPwrGdHighPCI Riser 5 V

10、voltage regulator has failed.AC Cycle or SEL clearYesAnyE1219BackplanePwrGdHighBackplane voltage regulator has failed.AC Cycle or SEL clearYesAnyE1221Flex BayPwrGdHighFlex Bay voltage regulator power good has failed.AC Cycle or SEL clearYesAnyE1222VCACHE #PwrGdHighVCACHE # voltage regulator has fail

11、ed.AC Cycle or SEL clearYesAnyE1223VRM #PwrGdHighVRM # voltage regulator has failed.AC Cycle or SEL clearYesAnyE1225ESB 1.5VPwrGdHighESB 1.5 VV voltage regulator has failed.AC Cycle or SEL clearYesAnyE1226PCIRsr1.5VPwrGdHighPCI Riser 1.5 VV voltage regulator has failed.AC Cycle or SEL clearYesAnyE12

12、27LinearPwrGdHighLinear voltage regulator(s) has failed. Represents status of multiple voltage regulators used in the video and LOM circuitry.AC Cycle or SEL clearYesAnyE12280.9VPwrGdHighMemory VTT voltage regulator has failed.AC Cycle or SEL clearYesAnyE1229CPU # VCOREHighProcessor # VCORE voltage

13、regulator has failed.AC Cycle or SEL clearYesAnyE122ACPU VTTPwrGdHighProcessor VTT voltage regulator has failed.AC Cycle or SEL clearYesAnyE122B0.9 V Over VoltageHigh0.9 V regulator voltage has exceeded the allowable voltage range.AC Cycle or SEL clearYesAnyE122CCPU Power FaultHighA voltage regulato

14、r failure was detected when the processor regulator(s) was enabled.AC Cycle or SEL clearYesAnyFans - Message Code: x13xxMessage CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?E1310RPM Fan #LowRPM of

15、fan # is outside of the intended operating range.Fan RPM reading returns to a point inside of the intended operating range.YesAnyE1311RPM Fan Mod #ALowRPM of fan A in the # module is outside of the intended operating range.Fan RPM reading returns to a point inside of the intended operating range.Yes

16、AnyE1311RPM Fan Mod #BLowSame as above except for fan B of module #.Fan RPM reading returns to a point inside of the intended operating range.YesAnyE1311RPM Fan Mod #CLowSame as above except for fan C of module #.Fan RPM reading returns to a point inside of the intended operating range.YesAnyE1311RP

17、M Fan Mod #DLowSame as above except for fan D of module #.Fan RPM reading returns to a point inside of the intended operating range.YesAnyE1313Fan RedundancyLowThe system is no longer fan redundant. Another fan failure would put the system at risk of over-heating.Fan redundancy is regained, which re

18、quires all fans to be operating within the intended operating range.YesAnyProcessors - Message Code: x14xxMessage CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?E1410CPU # IERRHighProcessor # has had

19、 an internal error (IERR), but this does not always mean that CPU is the problem .There are a large variety of issues that cause an IERR.AC Cycle or SEL clearYesAnyE1414CPU #ThermtripHighProcessor # has encountered a Thermtrip(over-temperature) event.AC Cycle or SEL clearYesAnyE1418CPU # PresenceHig

20、hProcessor # is missing/bad and the system is in an unsupported configuration.AC Cycle or SEL clearYesPre-POSTE141CCPU MismatchHighProcessors are not compatible as defined by Dell .System is in an unsupported configuration.AC Cycle or SEL clearYesPre-POSTE141FCPU ProtocolHighBIOS has reported a proc

21、essor protocol error.AC Cycle or SEL clearYesPOST, After POSTE1420CPU Bus PERRHighBIOS has reported a processor bus PERR (parity error).AC Cycle or SEL clearYesPOST, After POSTE1421CPU InitHighBIOS has reported a processor initialization error.AC Cycle or SEL clearYesPOST, After POSTE1422CPU Machine

22、ChkHighBIOS has reported a machine check error.AC Cycle or SEL clearYesPOST, After POSTSystem Memory - Message Code: x21xxMessage CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?E2110MBECrdx DIMM # &

23、#HighOne of the DIMMs in the set implicated by # & # has had a multi-bit error (MBE).If no memory riser is present the “Crdx” string is left out of the message.“x” is the memory riser, A-Z.AC Cycle or SEL clearYesPOST, After POSTE2111SBE Log DisableCrdx DIMM #HighBIOS has disabled memory single-bit

24、error (SBE) logging and will not log anymore SBEEs until the system is rebooted.# represents DIMM implicated by BIOS .If no memory riser is present the “Crd x” string is left out of the message.“x” is the memory riser, A-Z.System resetYesPOST, After POSTE2112MemSpareCrdx DIMM #HighBIOS has spared th

25、e memory because it has determined the memory had too many errors.# represents DIMM implicated by BIOS. If no memory riser is present the “Crdx” string is left out of the message.“x” is the memory riser, A-Z.System resetYesPOST, After POSTE2113Mem Mirror Crd x DIMM # & #HighBIOS has disabled memory

26、mirroring because it has determined one half of the mirror has had too many errors. # & # represents DIMM pair implicated by BIOS. If no memory riser is present the “Crdx” string is left out of the message.“x” is the memory riser, A-Z.System resetYesPOST, After POSTI2114MemRaidLowBIOS Memory RAID Ba

27、nkUser action, sensor return to normalYesAnyI2115MemAdded Card xLowMemory has been added while the system is running.AC Cycle or SEL clearYesAnyI2116MemRemovedLowMemory has been removed while the system is running.AC Cycle or SEL clearYesAnyE2117MemHot PlugLowMemory hot-plug operation has failed.AC

28、Cycle or SEL clearYesAnyE2118Fatal NBMemCRCHighNorthbound FBD CRC error on non-redundant entry. One of the connections in the FBD link on the Northbound (towards the MCH) side is broken.This is determined by the MCH when two CRC errors have been detected twice in a row.AC Cycle or SEL clearYesPOST,

29、After POSTE2119Fatal SBMemCRCHighFBD alert on non-redundant entry. One of the connections in the FBD link on the Southbound (towards the AMBson the FBDIMMs) side is broken.This is determined by the MCH when two CRC errors have been detected twice in a row.AC Cycle or SEL clearYesPOST, After POSTPowe

30、r Supplies - Message Code: x16xxMessage CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?E1610PS # MissingLowPower supply # was removed or is missing from the system.Failing device is reseated/replaced

31、/repaired.YesAnyE1614PS # StatusLowPower supply # has failed.Failing device is reseated/replaced/repaired.YesAnyE1618PS # PredictiveLowPower supply # has a failure that predicts a power down event in this supply (i.e. power supply fan failure or power supply over-temp).Failing device is reseated/rep

32、laced/repaired.YesAnyE161CPS # Input LostLowPower supply # is attached to the system but has lost its AC/DC input.Failing device is reseated/replaced/repaired.YesAnyE1620PS #Input RangeLowPower supply #s AC/DC input is outside of the allowable range.Failing device is reseated/replaced/repaired.YesAn

33、yE1624PS RedundancyLowThe power supply subsystem is no longer redundant. If the last supply fails the system will go down.Failing device is reseated/replaced/repaired.YesAnyE1625PS AC CurrentLowThe power supply input power is above the allowed amount for the power supply.Failing device is reseated/r

34、eplaced/repaired.YesAnyBIOS - Message Code: x17xxMessage CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?E1710I/O ChannelChkHighBIOS has reported an I/O channel check.AC Cycle or SEL clearYesPOST, Aft

35、er POSTE1711PCI PERR B# D# F#HighBIOS has reported PCI parity error on a component that resides in PCI configuration space at bus #, device #, function #.AC Cycle or SEL clearYesPOST, After POSTE1711PCI PERR Slot #HighBIOS has reported PCI parity error on a component that resides in slot #.Same as a

36、bove.Same as above.Same as above.E1712PCI SERR B# D# F#HighBIOS has reported a PCI system error on a component that resides in PCI configuration space at bus #, device #, function #.AC Cycle or SEL clearYesPOST, After POSTE1712PCI SERR Slot #HighBIOS has reported a PCI system error on a component th

37、at resides in slot #.Same as above.Same as above.Same as above.E1714Unknown ErrLowBIOS has determined there has been an error in the system but is unable to determine its origin.AC Cycle or SEL clearYesPOST, After POSTE171FPCIE Fatal Err B# D# F#HighBIOS has reported a PCIe fatal error on a componen

38、t that resides in PCI configuration space at bus #, device #, function #.AC Cycle or SEL clearYesPOST, After POSTE171FPCIE Fatal Slot #HighBIOS has reported a PCIe fatal error on a component that resides in slot #.Same as above.Same as above.Same as above.Hard Drives - Message Code: x18xxMessage Cod

39、eMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?E1810HDD # FaultLowHard drive # has had a fault as determined by the SAS subsystem.AC Cycle or SEL clearYesPOST, After POSTE1811HDD #RbldAbrtLowDrive # has

40、 had its rebuild aborted.AC Cycle or SEL clearYesPOST, After POSTE1812HDD # RemovedLowDrive # has been removed from the system.System reset or device is reseated/replaced/repaired.YesPOST, After POSTMiscellaneous- Message Code: x19xxMessage CodeMessage StringMessage PriorityMessage CommentsMinimum A

41、ction Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?I1910IntrusionLowThe chassis lid has been removed.Chassis lid is returned to the system.YesAnyI19113ERRsChkLogN/AUser must check the system event log (SEL) for the rest of the errors on the system .Thee LCD is l

42、imited to three error, warning, and/or informational messages at a time based on priority level.Less than 3 events to display on the LCD.NoAnyI1912SEL FullMedSystem Event Log is full of events and because of this is unable to log anymore. You must clear the log in order for the Server Management con

43、troller to log any more events.AC Cycle or SEL clearYesAnyE1913CPU & Firmware MismatchMedCurrent version of BMC firmware is incompatible with the Woodcrest processor.AC Cycle or SEL clearYesPOSTBIOS Progress Codes - Message Code: N/AMessage CodeMessage StringMessage PriorityMessage CommentsMinimum A

44、ction Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?N/APOWERN/A0x01 - System power-on.N/ANoAnyN/AMCODEN/A0x02 - CPU Microcode load.N/ANoAnyN/ACINITN/A0x03 - Chipset Initialization.N/ANoAnyN/AMEMCN/A0x04 - Memory Configuration.N/ANoAnyN/ASBIOSN/A0x05 - BIOS shadow

45、 into memory.N/ANoAnyN/APINITN/A0x06 - Multiprocessor Initialization.N/ANoAnyN/ASTARTN/A0x07 - POST processing start.N/ANoAnyN/ASMMN/A0x08 - System management interrupt (SMI) initialization.N/ANoAnyN/APCIENN/A0x09 - PCI Bus Enumeration & Video initialization.N/ANoAnyN/AVIDEON/A0x40 - Display sign-on

46、.N/ANoAnyN/APCICN/A0x41 - PCI Configuration.N/ANoAnyN/AOSN/A0x7F - Give control to OS.N/ANoAnyN/AE2010N/A0x80 - No memory installed in the system.N/ANoAnyN/AE2011N/A0x81 - Memory detected but is not configurable .Error detected during memory configuration. Could be result of bad memory, mismatched m

47、emory or bad socket.N/ANoAnyN/AE2012N/A0x82 - Memory configured but not usable. Memory sub-system failure. Could be the result of bad memory.N/ANoAnyN/AE2013N/A0x83 - BIOS failed to copy its flash image into memory. Could be the result of bad memory.N/ANoAnyN/AE2014N/A0x84 - CMOS failure. CMOSS RAM

48、not working.N/ANoAnyN/AE1215N/A0x05 - DMA controller failure.N/ANoAnyN/AE1116N/A0x80 - Interrupt controller failure.N/ANoAnyN/AE1217N/A0x07 - Timer refresh failure.N/ANoAnyN/AE1218N/A0x28 - Programmable interval timer error.N/ANoAnyN/AE0119N/A0x29 - Parity error.N/ANoAnyN/AE122AN/A0x2a - SIO failure

49、.N/ANoAnyN/AE122BN/A0x00b0 - Keyboard controller failure.N/ANoAnyN/AE141CN/A0x3c - System management interrupt (SMI) initialization failure.N/ANoAnyN/AE.11N/A0xC4 - BIOS shutdown test failure.N/ANoAnyN/AE.11N/A0xC4 - BIOS POST memory test failure. Could be the result of bad memory.N/ANoAnyN/AE141FN/

50、A0xC4 - Dell remote access controller (DRAC) configuration failure. Check screen for the actual error message.N/ANoAnyN/AE0000N/A0xC4 - CPU configuration failure. Check screen for the actual error message.N/ANoAnyN/AE1221N/A0xC4 - Incorrect memory configuration. Memory population order not correct.

51、Refer to the user guide.N/ANoAnyN/AE1222N/A22x - General failure after video. Check screen for the actual error message.N/ANoAnyBIOS Fatal Error Codes - Message Code: x20xxMessage CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System

52、 Phase When Event Can Occur?E2010No MemoryHigh0x80 - No memory installed in the system.System resetYesPOSTE2011MemConfigErrHigh0x81 - Memory detected but is not configurable. Error detected during memory configuration. Could be result of bad memory, mismatched memory or bad socket.System resetYesPOSTE2012Unusable MemoryHigh0x82 - Memory configured but not usable. Memory sub-system failure. Could be the result of bad memory.System resetYesPOSTE2013Shadow BIOS FailHigh0x83 - BIOS failed to copy its flash image into memory. Could be the result of bad memory.S

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论