版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、User Instructions: SE 1794 Flex I/O Faceplates09/13/07 Rev 1.0The SE 1794 Flex I/O Faceplates files allow you to quickly load, configure, and use preconfigured status and diagnostic displays or faceplates for Flex 1794 Digital and Analog I/O using RSView Supervisory Edition.The example below shows t
2、he types of Flex I/O template objects that can be added to a specific system display. The I/O button templates can be configured to launch the on-top status and diagnostic displays or faceplates for the particular I/O modules they represent.Example of I/O Button Templates used to launch a digital an
3、d analog faceplate1System CompatibilityThe faceplate files are compatible with: RSLogix5000 V15 or laterRSView Supervisory Edition 4.0 or later.Before using faceplate files, please upgrade your RSView Studio Supervisory Edition Version 4.0 with the patches posted on or after 01/01/07.The latest RSVi
4、ew Studio Supervisory Edition 4.0 patches may be found within the Rockwell Automation Knowledgebase at the following website/ Answer ID: /knowledgebaseAnswer ID:35680NOTE: These instructions are for local or distributed I/O on EtherNet/IP and ControlNet but not Device
5、Net.The following modules are compatible with these instructions:Digital1794-IA16/A1794-IA8/A1794-IA8I/A1794-IB10XOB61794-IB16/A1794-IB16D/A1794-IB16XOB16P1794-IB32/A1794-IB8/A1794-IB8S/A1794-IC16/A1794-IM8/A1794-IV16/A1794-OM81794-OW81794-OX81794-OA16/A1794-OB16/A1794-OB16D/A1794-OB16P/A1794-OB32P/
6、A1794-OC16/A1794-OV16/A1794-OV16P/AAnalog1794-IE121794-IE4XOE2B1794-IE81794-IE8H1794-IE8XOE41794-IF2XOF2I1794-IF4I1794-IR81794-IRT81794-IT81794-OE121794-OE41794-OE8H1794-OF4I2General Setup1) After downloading your file, the following folder will be created: SE_1794_Digital&Analog_Faceplate_Files. Th
7、is folder will contain the 1794 digital and analog I/O faceplate files, the 1794 parameter file and a “SE_1794_IO_Button_Templates” folder containing the templates for the 1794 I/O modules that can be used on your display.Logix Configuration1)Open existing Logix file with RSLogix50002)Add and config
8、ure the desired Flex I/O modules. (Skip to step 2e for distributed I/O).a.For Local I/O, right click on the FlexBus Local or Local2 and select “New Module”.b.Select the appropriate I/O module from the available listing.3c.Enter a distinct module name and description.d.Repeat step 2a-2c for all local
9、 Flex I/O modules.e.For distributed Flex I/O, right click on “Backplane, FlexLogix System” and select “New Module”. Then select the appropriate Communications module (i.e. 1788-CNC/A or 1788- ENBT/A) local to the controller.f.Give the new Communications module a name, a description and enter the cor
10、rect chassis size. For an ENBT give the IP address. For a CNB give the node number.4g.Right click the Communication module you just configured and select “New Module” to add the appropriate network adapter.h.Select the appropriate adapter module for the distributed I/O you are using.i.Give the new m
11、odule a name, description, an IP address, and choose a chassis size.NOTE: Do not set the Comm Format to Rack Optimization for these faceplates.5j.Right click on the network adapter and select “New Module”. for your system.Add the appropriate I/O modulek.Enter a distinct module name and description.l
12、.Repeat step 2j-2k for all distributed Flex I/O modules.RSView SE Configuration1) Open your existing RSView SE application that you wish to add the Flex I/O faceplate to.2) Add the appropriate “SE_1794-Ixx_Faceplate.gfx” or “SE_1794-Oxx_Faceplate.gfx” file to your displays.6a.Right-click on Displays
13、, and select “Add Component Into Application”. Browse to the SE_1794_Digital&Analog_Faceplate_Files folder and select the faceplate GFX file that matches the module you wish to create a faceplate for.3)Add the faceplate parameter file “SE_1794_Parameter.par” to your RSView SE application.a.Right-cli
14、ck on Parameters, and select “Add component Into application”. Browse to the SE_1794_Digital&Analog_Faceplate_Files folder and select the “SE_1794_Parameter.par” file. Then click the Open button.b.Now open the parameter that was just added and edit the “parameter tagname” to match your application.
15、The “parameter tagname” needs to include the RSLinx Enterprise “Device Shortcut” name of your systems controller and the Logix “tag name” of the intended Flex I/O module you wish to monitor.i. Double-click on the faceplate parameter file, and edit the “Device Shortcut” name7(in this example it is CL
16、X-L43) to match the Logix controller that was previously configured in your RSLinx Enterprise Communication Setup.ii.Enter the Logix “tag name” of the intended Flex I/O module to monitor.For modules that are local, this tag name will be the name “Local” followed by a “:” and the slot location of the
17、 module, ie., Local:1For modules that are distributed, this tag name will be the name of your adapter you added in step 2h of the Logix Configuration section, followed by a “:” and the slot location of the module,i.e. Network_Adapter:1Close and Save changes.8To add parameter files for additional Fle
18、x I/O modules, simply repeat steps 3a and 3b above, creating a unique parameter name by assigning the associated “Device Shortcut” and Logix “tag name” for each module.For modules that are local, change only the slot location of the tag name,Example: #1=CLX-L43Local:2 represents a module in slot 2.F
19、or modules that are distributed, this tag name will be the name of the additional I/O adapters, followed by a “:” and the slot location of the module.Example: #1=CLX-L43Network_Adapter_2:1 (“Network_Adapter_2” represents another unique name for an I/O adapter on the network and “:1” represents the m
20、odule in slot 1.)4)Create the display navigation to open the 1794 I/O Faceplates at runtime. (To use the I/O button templates for the 1794 Modules skip to pg 11, Configuration Steps for using the I/O Button Templates.)a.On a desired graphic display, create a new button object.b.Double-click on the b
21、utton object to display its properties and configure the Action tab. Click onthe browse (i.e. ellipses,) button beside the Press Action field to launch the Command Wizard.c.Select the Display command and click Next.d.Use the browse buttons, drop down menus and the Parameter File checkbox to select t
22、he appropriate area, display and parameter file name and click Finish.9e.The Display command syntax has now been configured and inserted into the Press Action field.f.Configure the remaining Button Properties if desired and click OK.g.Repeat steps 4a-4f for navigation to any additional Flex I/O modu
23、les, using a unique parameter file for each additional Flex I/O module.5) Now, you can save and create a runtime file to test your display.10Configuration Steps for using the I/O Button TemplatesIf you desire a hardware system view as shown below, with each module in the chassis configured as a disp
24、lay navigation button that can launch individual Flex I/O faceplates, follow these instructions.1)Add the 1794 bitmap images into your RSView application by right clicking onto the Image folder in the system tree and choosing “Add Component into Application.”112)Browse to your “SE_1794_IO_Button_Tem
25、plates” folder that was created in step 1 under General Setup. Select all the 1794 Bitmaps images. Click Open.3)Next, add the 1794 display navigation files into your RSView Application by right clicking on the Display folder in the system tree and by selecting “Add Component into Application.”4)Brow
26、se to your “SE_1794_IO_Button_Templates” folder and select all the GFX files. Verify the displays appear under Displays in your system tree.Click Open.125)Create a new Display or open your own system display to copy the I/O button templates to.6)Open the “Goto_Flex_Adapters_and_Controllers” displays
27、 and copy (or drag and drop) your desired graphic object onto your system display.7)Open the “Goto_Flex_Input_Modules” or “Goto_Flex_Output_Modules display and copy (or drag and drop) your desired modules onto the display.138)Repeat step 7 until all the required modules have been copied onto the cha
28、ssis.9)Double click twice on a module to launch the button properties (be sure to click near the top of themodule to open the Button properties and not the “text” object properties). display area and select Object Explorer to use its object list.Or right click on the10)To configure the Action tab, click on the browse (i.e. ellipses, to launch the Command Wizard.) button beside the Press Action field1411)Select the Disp
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 新型军民用电声终端研发与TWS耳机智能制造基地项目可行性研究报告模板-申批备案
- 2026年市场营销策略专项训练试卷带答案
- 2026年赣州语文高考题目及答案
- 2026年江西财经职业学院招聘编制外合同聘用制人员9人笔试备考题库及答案解析
- 2026年河北中烟工业有限责任公司人员招聘考试模拟试题及答案
- 2026广东博罗县产业投资集团有限公司所属企业招聘11人考试模拟试题及答案解析
- 2026黔西南州秋季赴省内外高校引进高层次人才和急需紧缺人才128人笔试参考题库及答案解析
- 2026北京灵枢医药文化有限公司社会招聘3人笔试备考试题及答案解析
- 2026年联通数字科技有限公司人员招聘考试备考试题及答案
- 2026海城市公开选调事业单位工作人员12人笔试参考题库及答案解析
- 2026年爆破员考试模拟试题新题库附答案
- 老年髋部骨折患者围手术期管理专家共识
- 车辆叉车日常检查记录表
- 江苏省无锡市2025-2026学年高三上学期11月期中考试地理试卷
- 《信息技术基础》课件 第2章 Windows11操作系统
- 国企党建考试题库及答案
- 西安交通大学少年班自主招生物理试卷试题及答案(2025年)
- 《WPS AI智能办公应用大全》全套教学课件
- 财务经营意识培训
- 电气火灾 培训 课件
- 2025年行政执法人员执法证考试必考多选题库及答案(共160题)
评论
0/150
提交评论