1、Light SourcesTipFor long bulb life and accurate results, always allow your Ocean Optics light source to warm up for the recommended amount of timeprior to use.Our line of cleverly designed light sources covers the entire UV-NIR wavelength range and combines innovation with reliability to give youser

2、ious performance and precision.From design features like built-in filter slots to optional accessories such as direct-attach cuvette holders, nothing is more convenient and simple to use than Ocean Opticslight sources.These low-cost, modular light sources feature SMA 905 connectorsfor quick and easy

3、 connection.Light SourcesLightSourcesSources for I lumination, Excitation and CalibrationThe development of Ocean Optics miniature spectrometers created the need for comparably sized and priced accessories, including light sources. Since no such sources existed, we developed our own - compact, modul

4、ar sources for illumination, excitation and calibration.Our light sources for illumination cover various wavelength ranges to enable absorbance, transmission and reflectance measurements from the deep UV to themid-IR. Light-emitting diodes produce output for fluorescence measurements. For fast, reli

5、able spectrometer wavelength calibrations, we offer a range of options. Design fea- tures such as built-in filter slots, combined with optional accessories such as direct-attach cuvette holders, make sampling simple.86Tel:Light SourcesTypeProductWavelength RangeOutputMeasurement TypeDeuterium Tungst

6、en HalogenDH-2000-BAL DH-2000215-2500 nmContinuousAbsorbance, Fluorescence, Reflectance, TransmissionMiniature Deuterium Tungsten HalogenDT-MINI-2-GS215-2500 nmContinuousAbsorbance, Reflectance, TransmissionDeuteriumD-2000215-400 nmContinuousAbsorbance, Fluorescence, Reflectance, TransmissionXenonPX

7、-2HPX-2000220-750 nm185-2000 nmPulsed ContinuousAbsorbance, Fluorescence, Reflectance, TransmissionLEDsVariousMany options from 240 nm-whitePulsed or ContinuousFluorescenceTungsten HalogenHL-2000360-2500 nmContinuousAbsorbance, Reflectance, TransmissionSilicone Nitride EmitterCOOL-RED1000-5000 nmCon

8、tinuousAbsorbance, Reflectance, TransmissionCalibrated Deuterium Tungsten HalogenDH-2000-CAL220-1050 nmContinuousCalibration (Radiometric)Calibrated Tungsten HalogenHL-2000-CAL380-1050 nm (typical)ContinuousCalibration (Radiometric)Mercury ArgonHG-1253-1700 nmContinuousCalibration (Wavelength)ArgonA

9、R-1700-1700 nmContinuousCalibration (Wavelength)NeonNE-1540-754 nmContinuousCalibration (Wavelength)XenonXE-1916-984 nmContinuousCalibration (Wavelength)KryptonKR-1427-893 nmContinuousCalibration (Wavelength)Modular Light Source OptionsUV Light SourcesHigh-Powered LEDsWe offer deuterium sources for

10、UV absorbance and reflectanceUsed as excitation sources for fluorescence. Feature minimal warm-up measurements. Our pulsed xenon lamps are long-life sources forand high stability. Power is lower and spectral width is wider than with absorbance, reflectance and fluorescence measurements, and forlaser

11、s. We offer a full range of options for UV-NIR. LEDs are available measuring optically or thermally labile samples.individually and with rugged housings.Combination Deuterium and Tungsten Light SourcesRadiometrically Calibrated Light SourcesUsed as single illumination sources for UV-NIR measurements

12、.Used to calibrate the absolute spectral intensity of a system inirradiance applications.VIS-Mid-IR Light SourcesTungsten halogen sources are standard VIS-NIR light sources forWavelength Calibration Sourcesabsorbance, reflectance of solid objects, and color measurement.Used to calibrate the waveleng

13、th of spectrophotometric systems. We Our Cool Red source has response into the mid-IR.offer a full range of options for your UV-VIS needs.LightSourcesTools For Manipulating LightModifying LightOcean Optics products give you countless options for modifying the light transmitted to your spectrometers

14、detector. Depending on your application needs, we provide a number of methods for changing the way light interacts with your configuration.For high-intensity applications such as laser characterization, steps must be taken to avoid detector saturation. In other cases, changing the fiber size or addi

15、ng mirrors to your spectrometer bench may increase light collection efficiency.Entrance Aperture: SlitAn installed slit acts as the entrance aperture to the optical bench and regulates the amount of light that enters. You specify the slit size. Options range from 5 to 200 µm.Fiber Optic Variabl

16、e AttenuatorOur FVA-UV Fiber Optic Variable Attenuator is an opto-mechanical device that helps control the amount of light transmitted between two fibers. This attenuates light uniformly at all wavelengths from the ultraviolet through the near-infrared.Installed FiltersIn addition to the variable lo

17、ngpass filters (order-sorting filters applied to the detectors window), we offer optional bandpass and longpass blocking filters that restrict radia- tion in certain wavelength regions.Optical FiberOur optical fibers are available in diameters ranging from 8 µm to 1000 µm. If you require m

18、ore light for your application, youll want a larger diameter fiber. In the absence of a slit, the fiber connected to the spectrometer acts as the optical benchs entrance aperture.Integration TimeThis software setting is similar to the shutter speed of a camera. The higher the value specified, the lo

19、nger the detector“looks” at incom photons. Using our companion software, you can adjust this setting to suit different applications.Neutral Density FiltersWith a neutral density filter installed at your light source or sampling device, you can reduce the intensity of light that reaches the detector

20、across all wavelengths. Filters are2-mm thick and 8 mm in diameter and come in optical density levels of 0.6 (25% transmis- sion), 1.0 (10%) and 2.0 (1%).Linear Variable FiltersOur high-pass, low-pass and adjustable bandpass filters have excellent blockingcharacteristics and ideal for spectrally sha

21、to heat. They arethe light emitted from broadband sources.Loose FiltersOur loose filters fit into our light sources, cuvette holders and in-line filter holders. High-pass filters eliminate second- and third- order effects, test for stray light and blockGershun Tube KitsGershun Tube Kits are ideal fo

22、r solar irradiance measurements and feature an SMA 905-terminated barrel that attaches to a fiber or the spectrometer. This provides control of the aperture size. Simply select one of the interchangeable aluminum apertures to adjust the field of view of the device from 1° to 28°.excitation

23、 energy. Balng filters absorbenergy in some regions while transmitting in others. Bandpass filters pass energy in one region and block light above and below that region.Tel:87Light SourcesDH-2000-BALBalanced Deuterium Tungsten Halogen Light SourceWeve applied our expertise in patterned dichroic filt

24、ers to create the only combined-spectrum illumination source available that eliminates saturation and signal-to-noise issues associated with the D-alpha line in deuterium sources. Our DH-2000-BAL Deuterium Tungsten Halogen Light Source combines deuterium and tungsten halogen light sources into a sin

25、gle optical path that produces a powerful, stable output from 215-2500 nm.About the D-alpha LineAll deuterium-tungsten halogen sources have a D-alpha line, revealed as a jagged peak in the visible portion of the spectrum, that produces“unbalanced” output in the deuterium and tungsten halogen sources

26、. Correcting for this deuterium line a sharp spectral feature near 655 nm is difficult.For example, if you adjust spectrometer integration time to reduce the intensity of this saturated spectral line, the efficiency of the system at UV wavelengths drops significantly, compromising signal-to-noise pe

27、rformance. Also, spectrometer efficiency is greatest at about the same spectral range as the655 nm line, exaggerating its effects.Proprietary Filtering TechnologyUsing the same high-precision patterned dichroic filter technology that distinguishes our Linear Variable Filters, the DH-2000-BAL balance

28、s the intensity of the deuterium and tungsten halogen sources, producing a “smoother” spectrum across the entire wavelength range and eliminating problems associated with saturation. By comparison, most combination UV-NIR sources can be adjusted for relative intensity only.Measured with HR2000+ with

29、 25 µm Slit and 400 µm Optical Fiber88Tel:Light SourcesSpecificationsDimensions: Weight: Wavelength range:Power consumption:Power requirements: Voltage:Current: Stability:Drift:Time to stable output: Bulb life:Operating temperature: Humidity:Electronic certifications:150 mm x 135 mm x 319

30、mm3.8 kg215-400 nm (deuterium); 360-2500 nm (tungsten halogen)25 W (deuterium); 20 W (tungsten halogen); 190 Wum85-264 V 50/60 HzIgnition 350 V/20° tungsten bulb voltage is adjustable from 4.5 to 11.5 voltsOperating 85 V/0.3A<5 x 106 peak-to-peak (0.1-10.0 Hz)<0.01% per hour40 minutes (de

31、uterium); 20 minutes (tungsten)1,000 hours5 °C - 35 °C5-95% non-condensing at 40 °CCE; VDI/VDE 0160; EN 61010Technical TipUltraviolet radiation below 300 nm degrades transmission in silica fibers, resulting in solarization (increased light absorption in the UV fiber that can invalidat

32、e data). For applications using the DH-2000 Light Sources <300 nm, we recommend solarization-resistant assemblies. See Page 137 fors.DH-2000-BAL Spectral OutputDH-2000Deuterium Tungsten Halogen Light SourceOur DH-2000 Deuterium Tungsten Halogen Light Source combines the continuous spectrum of deu

33、terium and tungsten halogen light sources into a single optical path for powerful output from 215-2500 nm. In addition, Deep-UV versions of our DH-2000 are available with a 190-2000 nm range.Options and Accessories: Shutter and Filter Holder Integrated shutters are available for your DH-2000 and can

34、 be driven by either a switch or a TTL signal.You can also include a filter holder with the source that accepts filters up to 4 mm in thickness and as large as 25 mm square or 25 mm round. The DH-2000 has an SMA 905 connector for easycoupling to our spectrometers and accessories via an optical fiber

35、.Adjustable PowerThe DH-2000 has a potentiometer that adjusts the intensity of the tungsten halogen output. This allows you to adjust the optical power of the light source from 10-100%.Measured with HR2000+ Spectrometer with 25 µm Slit and 400 µm Optical FiberTel:89Light SourcesItem CodeDe

36、scriptionDH2000-DUVUses a Deep-UV deuterium bulb that provides 190-2000 nm wavelength rangeDH2000-SIncludes shutter control via a TTL signal or manual switch up to 5 HzDH2000-S-DUVUses a Deep-UV deuterium bulb that provides a 190-2000 nm wavelength range; includes shutter control via a TTL signal or

37、 manual switch up to 5 HzDH2000-FHSIncludes a filter holder for filters up to 25 mm square or 25 mm round and 4 mm thickDH2000-FHS-DUVUses a Deep-UV deuterium bulb that provides 190-2000 nm wavelength range; includes a filter holder for filters up to 25 mm square or 25 mm round and 4 mm thickSpecifi

38、cationsDimensions:150 mm x 135 mm x 319 mmWeight:3.5 kgPower consumption:25 W (deuterium); 20 W (tungsten halogen)Wavelength range:190-400 nm (deep-UV deuterium bulb) 215-2500 nm (standard deuterium and tungsten halogen bulbs)Humidity:5-95% without condensation at 40 °CLamp current:Operating 85

39、 V/0.3ALamp lifetime:1,000 hoursLamp voltage:Ignition 580 V at 20 °CCurrent voltage drift:<0.01% per hourCurrent voltage stability:<5 x 106 peak-to-peak (0.1-10.0 Hz)Operating temperature:5 °C - 35 °CPower requirements:85-264 V 50/60 HzRadiation characteristic:Aperture 0.5 mm, n

40、umerical aperture 26°(13°); focused Total power: 100 WPower consumption:Approximately 78VAWarm-up time:40 minutes (deuterium);20 minutes (tungsten halogen)Markings:CE; VDI/VDE 0160; EN 61010DH-2000 Series Spectral OutputDT-MINI-2-GSMini Deuterium Tungsten Halogen Light SourceUV-NIR Spectra

41、l RangeThe DT-MINI-2-GS Deuterium Tungsten Halogen Light Source combines the continuous spectrum of an RF-excited deuterium UV light source and a tungsten halogen VIS-NIR light source in a single optical path.The combined-spectrum sources produce stable spectral output from215-2500 nm in a compact p

42、ackage.Powerful Output 0.5 mm ApertureThe DT-MINI-2-GS Deuterium Tungsten Halogen Light Source also utilizes a bulb with a 0.5-mm diameter aperture. It also has a shutter for blocking the light path, which can be controlled via a manual switch or TTL.There is also a switch for turning the deuterium

43、source on and off, and one for turning the tungsten halogen source on and off; each switch can be used independently of the other.Note: Use item code DT-MINI-2-B when ordering replacement bulbs for the DT-MINI series miniature deuterium tungsten halogen light sources.Measured with HR2000+ Spectromet

44、er with 25 µm Slit and 400 µm Optical Fiber90Tel:Light SourcesSpecificationsDimensions: Weight: Wavelength range:Power consumption: Output:Stability:Time to stable output: Bulb life:Ignition delay:Connector:140 mm x 50 mm x 125 mm475 g215-2500 nm350 mA 12 VDC3.8 watts (deuterium); 1.2 watt

45、s (tungsten halogen)1.0% peak-to-peak (over 4 hours) after 30-minute warm-up10 minutes (deuterium); 1 minute (tungsten halogen)1500 hours (deuterium); 1500 hours (tungsten halogen)<2.0 seconds (delay for cold start-up may be longer)SMA 905Technical TipThe DT-MINI-2-GS is your go-to choice for app

46、lication setups requiring UV and VIS-NIR illumination.However, we also offer our USB-DT, which can be used as a standalone source, stacked atop a USB2000+ or USB4000 Spectrometer or connected to your HR- or QE- spectrometer using a breakout box. The latter allows you to control multiple functions th

47、rough software.For assistance in selecting the optimum miniature deuterium tungsten halogen light source for your application, please contact an Ocean Optics Applications Scientist.DT-MINI-2-GS Spectral OutputD-2000Powerful, Stable Deuterium Source for UV ApplicationsDeuterium Light SourceThe D-2000

48、 Deuterium Light Source delivers robust, even output from 215-400 nm with peak-to-peak stability of less than 0.005% and drift of only +/-0.5% per hour.D-2000 is also available in a Deep-UV configuration that provides you a wavelength range of 190-400 nm.Options and AccessoriesIntegrated shutters ar

49、e also available with the D-2000 and can be driven by a TTL signal. All versions of the D-2000 have an SMA 905 Connector for easy coupling to our spectrometers and fiber optic accessories, a safety shutter for blocking the light when the fiber is not attached, and safety goggles. The 1,000-hour deut

50、erium bulb used in the D-2000 can be replaced easily.Measured with HR2000+ Spectrometer with 25 µm Slit and 400 µm Optical FiberTel:91Light SourcesOrdering InformationItem D2000D2000-DUVD2000-S D2000-S-DUVDH2000-BD DH2000-DUV-BDescriptionDeuterium light source, 215-400 nmD-2000 configured

51、with a Deep-UV deuterium bulb that provides a 190-400 nm wavelength rangeD-2000 configured with a shutter (controlled via a TTL signal or switch)D-2000 configured with Deep-UV deuterium bulb that provides a 190-400 nm wavelength range and includes a shutter (controlled via a TTL signal or switch)Rep

52、lacement deuterium bulb for the D-2000 and the D-2000-SReplacement deuterium bulb for the D-2000- DUV and the D-2000-S-DUVSpecificationsDimensions: Weight:Power consumption: Wavelength range: Peak-to-peak stability: Drift:Warm-up time: Voltage and current: Bulb lifetime:Operating temperature: Humidi

53、ty:Radiation characteristic: Power requirements: Markings:TTL-shutter input:Shutter speed:150 mm x 135 mm x 319 mm5.35 kg (without power cord)830 mA 230 VDC or 1660 mA 115 VDC215-400 nm (standard bulb); 190-400 nm (deep-UV bulb)<0.005% at 250 nm+/-0.5% per hour at 250 nm 40 minutesIgnition 350V/2

54、0° operating 85 V/0.3A 1,000 hours for standard or deep-UV bulb 5 °C - 35 °C5-95% without condensation at 40 °CAperture 0.5 mm, numerical aperture 26° (13°) 85-264 V 50/60 HzCE; VDI/VDE 0160; EN 61010Up to 5 Hzum (shutter versions only) 10 ms minimumTechnical TipUltravi

55、olet radiation below 300 nm degrades transmission in silica fibers, resulting in solarization (increased light absorption in the UV fiber that can invalidate data). For applications using the D-2000 Light Sources, we recommend solarization-resistant assemblies. See Page 137 fors.D2000-S-DUV Series S

56、pectral OutputHPX-2000High-Powered Continuous Wave Xenon Light SourceHigh Power OutputThe HPX-2000 Xenon Light Source is a high-power source that is a brilliant companion for fluorescence applications and for other applications wherea high-intensity lamp is necessary. The 35-watt, short-arc lamp con

57、tinuous spectrum from the UV through the NIR (185-2000 nm).s aIntegrated ShutterThe HPX-2000 features an integrated shutter that can be triggered by either a switch or by a TTL signal. The HPX-2000 also comes equipped with a slot for filters up to 25 mm in diameter or 25 mm square and up to14 mm thick.Measured with HR2000+ Spectrometer with 25 µm Slit and 400 µm Optical Fiber92Tel:Light SourcesSpecificationsDimensions: Weight:Power consumption: Wavelength range: Power output: Trigger input:

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论