QuickInstallationGuideECR-LW
TheseshortoperatinginstructionsapplyforthefollowingdevicesofINSYSicom:
ECR-LW300
/manual
ECR-LW320
Itisintendedforaquickcommissioningbytheoperator.Refertotheassociatedmanualforfurtherinformation.ThisandotherassociatedmanualscanbefoundonourwebsiteinthemenuSupport>DocumentationandDownloads.ScantheQRcodeaboveorentertheURLintoyourwebbrowser.
TechnicalData
Theproductisonlyintendedfortheusewithinthepermissibletechnicallimitsspecifiedinthedatasheets.Theselimitsmustbeobserved.
ENGLISH
QuickInstallationGuideECR-LW
Operatingvoltage12V…24VDC(±20%)Powerconsumptiontyp.3W,max.7W
LevelinputHIGHlevel=10...24V
LOWlevel=0...5VContactopencondition:LOW
Currentconsumptioninputatmax.3mAat24VDCHIGHpotential
Digitaloutput(open24V(DC),100mAcollector),max.load
Max.voltagedropofthe<1V(DC)at100mAloadoutputinconditionON
OutputpowerWLAN(Wi-Fi)max.100mW
LTEfrequencies(4G)
UMTS/HSPAfrequencies(3G)
GSM/GPRSfrequencies(2G)
Temperaturerange
Maximumpermissiblehumidity
IPrating
700,800,900,1800,2100MHzbands1,3,8,20,28(ECR-LW300)700,850,900,1800MHz
bands3,5,8,28(ECR-LW320)
900,2100MHz,bd.1,8(ECR-LW300)850,900,2100MHz
bands1,5,8(ECR-LW320)
900,1800MHz(ECR-LW300)
-30°C…70°C(75°Cextended)
95%non-condensingHousingIP40
ENGLISH
QuickInstallationGuideECR-LW
TechnicalBoundaries
Max.linelengthsforantennas,powersupply,serialinterfaces,inputsandoutputsaswellasothersignals:30mCablecross-section:0.25…1.5mm²,flexiblelinesrequireendsleeves
Support
Ifyouneedfurthersupport,pleasecontactyoursalespartnerorINSYSicomsupport.Youcancontactoursupportdepartmentviae-mailundersupport@insys-icom.de.
DefectsLiabilityTerms
Auseotherthantheintendeduse,anignoranceofthesafetyinstructionsandthedocumentation,theuseofinsufficientlyqualifiedpersonnelaswellasunauthorisedmodificationsexcludetheliabilityofthemanufacturerfordamagesresultingfromthis.Theliabilityofthemanufacturerceasestoexist.
IntendedUse
Theproductmayonlybeusedforthepurposesspecifiedinthefunctionoverviewofthemanual.Inaddition,itmaybeusedforthefollowingpurposes:
Usageandmountinginanindustrialcabinet.
Switchinganddatatransmissionfunctionsinmachinesaccordingtothemachinedirective2006/42/EC.
Usageasdatatransmissiondevice,e.g.foraPLC.
Theproductmaynotbeusedforthefollowingpurposesandusedoroperatedunderthefollowingconditions:
Use,control,switchinganddatatransmissioninmachinesorsystemsinexplosiveatmospheres.
Controlling,switchinganddatatransmissionofmachines,whichmayinvolveriskstolifeandlimbduetotheirfunctionsorwhenabreakdownoccurs.
A
Routerconnection
InsertSIMcard(Mini-SIM,2FF)withcontactsfacingtothefrontandchamferfacingtotherouterinto“SIM1”slot
ConnectantennatoconnectionLTE(SMA(f)).Thescreenoftheantennasystemmust
beconnectedtotheprotectiveconductorwhenusinganoutsidemountedantenna!
Connectsupplyvoltage(12V…24VDC(±20%))totheterminalsV-andV+
Connectrouter(ETH1)totheconfigurationPC
Connectrouter(ETH2)tothenetwork
inwhichyoursystemislocated(localapplicationnetwork)
B
LANsettingsofconfigurationsPC(Windows7)
IfaDHCPclientisactiveonthePC,proceedwithstepC.Otherwise,eitherenabletheDHCPclientorconfigureastaticIPaddress.
OpenNetworkandSharingCenter(e.g.keyandsearchfor"sharing")
SelectLANconnectionandProperties
SelectInternetProtocolVersion4(TCP/IP)andProperties
EnableDHCPclientConfigureastaticIPaddress
9.
ObtainanIPaddressautomaticallyUsethefollowingIPaddress(example):
ItisrecommendedtounplugtheIPaddress:192.168.1.2networkcablebrieflyandplugitSubnetmask:255.255.255.0againuponactivationoftheDHCPStandardgateway192.168.1.1client.
PreferredDNSserver:192.168.1.1
PleasenotethepreviousvaluesbeforechangingtheTCP/IPsettingstobeabletorestorethemlater.
C
Webinterfaceaccess
EnterIPaddressoftherouterinaddressbarofthebrowser(default:)
Ifaproxyserverisenabledinyourbrowser,thismustbedisabledortheIPaddressoftheroutermustbeaddedasexception.
LoginwithName(default:insys)andPassword(icom)
OpentheInlineHelpusingthebutton(Displayhelptext)intheheader
ThelinksintheInlineHelpleadtotheOnlineHelpwithfurtherinformation.
AllmodifieddatawillonlybestoredintheopenedprofileafterclickingtheSavesettingsbuttonandbecomeeffectiveuponclickingthe(Activateprofile)button.
D
ConfigurationasInternetrouterviacellularradio
InMenuHelp>Wizards:SelectStartupWizard
SelectInternetaccessviaCellularnetwork(refertoinlinehelpforWANoverEthernet)
ThefollowingdatacanbefoundinthecontractdocumentsofyourSIMcardorcanberequestedfromtheprovider.TheAPNsofpopularproviderscanbedisplayedbyclingingon.
EnterPINoftheSIMcard
EnterUsernameandPasswordforauthenticationwiththeprovider(mustnotbeempty)
EnterAccessPointName(APN)
EnterIPaddressofthelocalapplicationnetwork
IftherouteristobeconfiguredfortheicomConnectivitySuite-VPN(https://connectivity.insys-icom.de),selecticomConnectivitySuite–VPNunderVPNconnectionandenterCustomernameandDevicecode(fromicomConnectivitySuite–VPN,“MyVPNHub”tab).Then,theIPaddressinthelocalnetworkwillbeassignedbytheicomConnectivitySuite-VPN.
ClickonExecutewizard
TheWANLEDflashesgreenduringconnectionestablishment;assoonasanInternetconnectionhasbeenestablished,itisilluminatedgreenandtheSignalLEDflashesgreen.
Ifthewebinterfaceoftherouterdoesnotreturnuponexecutingthewizard,clickon“Reload”inthebrowser(orCtrl+F5).
E
Configurationofaccessdata
Usernameandpasswordforwebinterfaceaccessoftheexistinguserinthedefaultsettingsmustbechangedtopreventamanipulationoftheconfigurationbyunauthorisedpersons.
MenuAdministration>Users:EnterorchangeUsernameandPasswordandselectUsergroup"Read/Write"
StoresettingsinprofilewithSavesettingsandactivateprofilewith
Atypoduringenteringorforgettingtheconfiguredaccessdatarequirearesettodefaultsettingstobeabletoaccesstherouteragain.
Allessentialconfigurationstepsarecompletedwiththis.Furtherconfigurationdependsonyourspecificapplication.Otherfrequentlyrequiredsettingsareavailableonthefollowingpage.
Availabilityoftherouteruponconfiguration
Thewizarddeactivatestheconfigurationnetwork(IPnet1)andassignsETH1tothelocalapplicationnetwork(IPnet2).Inaddition,itconfiguresthepreviousdefaultaddressasadditionalIPaddressforIPnet2thattheconfigurationPCstillhasaccessafterexecutingthewizard(ifthishasnotalreadybeenassignedinthelocalapplicationnetwork).
UsingtherouterasicomSmartGateway
IftherouteristobeusedasanicomSmartEnergyGatewayoricomSmartMachineryGatewayforexample,thisisthebesttimenowtoinstalltheicomDataSuiterequiredforthis.AwizardisavailableforthisintheHelpmenu.RefertotheQuickInstallationGuideoftheicomDataSuite(/manual#icom-data-suite)ortherespectiveConfigurationGuide(https://docs.insys-icom.de/en_icom_data_suite.html).
Resettingtherouter
Ifitisnecessarytoresettherouterduringconfiguration,thisispossiblewithoutlosingthesettings.
MenuAdministration>Reset
ClickonRebootdevicenow
Alternatively,pressresetkeyonthedevicefrontonceforashorttime(softreset)
Resettingtheroutertodefaultsettings
Iftherouteristoberesettodefaultsettings,itcanberesettodeliverystate.
MenuAdministration>Reset:checkalloptions
ClickonResetnow
Alternatively,pressresetkeyonthedevicefrontthreetimesforashorttimewithin2seconds
Resettingandinitialisingtherouter
Iftherouterisnotavailableanymoreforanyreaso
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 幼儿园老师保育工作总结8篇
- 适合汽车修理厂使用的营销方案
- 幼儿园的退学申请书5篇
- suv汽车普通买卖合同
- 集团内部竞聘方案
- 农村房基地买卖版合同
- 外贸购销合同实例(中英文对照)
- 2024春节文化活动方案5篇
- 社会小调查实践报告模板5篇
- 幼儿园防寒教案8篇
- 安徽省合肥市一中、六中、八中2023-2024学年高考冲刺押题(最后一卷)语文试卷含解析
- 第12课 19世纪下半期资本主义的扩展(教学设计)-【中职专用】《世界历史》
- 2024年二建《(矿业)专业工程管理与实务》核心考点速记速练200题(详细解析)
- 鉴赏诗歌人物形象市公开课一等奖省赛课微课金奖课件
- 杭州市西湖区文新街道招考编外用工高频考题难、易错点模拟试题(共500题)附带答案详解
- 墓碑墓穴采购安装质量保障方案
- 环境保护水土保持技术交底样本
- 会展旅游 课件全套 第1-11章 会展与会展旅游概述- 会展旅游的国际比较
- 莎士比亚戏剧赏析智慧树知到期末考试答案2024年
- 招标代理服务 投标方案(技术方案)
- 2024年山东省聊城市东昌府区一模生物试题
评论
0/150
提交评论