




已阅读5页,还剩20页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
温湿度传感器 temperature and humidity sensor condensed water p 引用文件 xref file 文件名filename local controller di数字量输入 date日期 现场控制器 nddc1 模拟量输出do rvvp-3x1.0 rvvp-3x1.0 rvvp-5x1.0 rvvp-5x1.0 rvvp-3x1.0 模拟量输出ao 模拟量输入ai 说明: 现场控制器 nddc2 压差开关 pressure difference switch th local controller rvvp-5x1.0 rvvp-5x1.0 rvvp-3x1.0 rvvp-5x1.0 rvvp-4x1.0 rvvp-3x1.0 8mcc-3 rvvp-3x1.0 rvvp-4x1.0 rvvp-3x1.0 rvvp-3x1.0 rvvp-3x1.0 8mcc-2 d2 冷冻水回水 chilled water return chilled water supply condensed water 蒸汽 steam 冷冻水供水 凝结水 0.3mpa (q =165kw) g=275kg/h 热 m 7c (q =642kw) g=111t/h 12c 冷 md1 outdoor air 新风 3 35000m /h th p th p 3 35000m /h 冷冻水回水 0.3mpa (q =61kw) condensed water steam 蒸汽 chilled water return chilled water supply 冷冻水供水 凝结水 z g=102kg/h 热 md4 12c 冷 g=9.3t/h 7c (q =54kw) md3 ahu1-14 th p th ahu1-11 p 20000m /h3 3 20000m /h m 0.3mpa (g=72kg/h) 蒸汽 steam 凝结水 建 筑 专 业 工 艺 总 图 结 构 专 业 暖 通 给排水 签 署签 署签 署专 业 供 电 气体动力 电 照 签 署 控 制 专 业 通 信 a0 回风 45000m /h return air return air 回风 80000m /h z 3 3 th ahu control ptinciple diagram no.1 building no.1(main building) corporation eleventh design and when the temperature is in winter: indoor temperature is controlled by steam electric two-way valve d2 when f1 is opened and f2 is closed.when the temperature is higher than 24.2c,turn down d2;when the temperature is lower than 22.2c,turn up d2. indoor humidity is controlled by steam humidifier d3.when indoor humidity is higher than 50%,turn down d3;when the humidity is lower than 80pa or the data of the middle filter is more than 160pa,give out the alarming signal. th p 说明: 3.indoor temperature and humidity control: higher than 26.6c,then turn up d1. than 40%,turn up d3. 3 s1kzyl2 文件名 0007003 项目号:设计阶段 page no. 2000.9 date 日期: 无 scale 比例:张号: s72-1-13a13a/15 drawing no. 图号: building no.1(main building) ahu control ptinciple diagram no.4 c h i n a lhd lhd approved current revision intel technology (china) ltd project no. date 1号建筑(主厂房) drawing title: 控制原理图(四) file name revision description corporation r 图纸名称 5.31 6.29 dateas built date shanghai 平面位置示意图 confidential key plan 101 设计证书号 corporation edri ahu1-7空调原理说明 1.fire resisting-dampers should be interlocked with the air suppling units and the air exhausting units.when the temperature in the air pipe reches 70c, ahu1-7 air conditioning principle specification the dampers will be shut off automatically,and at the same time the power of air supplying and exhausting units will be also shut off.the signal will be delivered to the duty room.when fire signal is received in the duty room,the on-duty worker can shut off the fire resisting dampers and cut off the 电源,并将信号传至值班室。另外,当消防值班室接到火警信号时,也可由消防人员手动远距离关闭防火 2.空调系统的初效,中效过滤器的压差受到监测,当过滤器阻力大于下列值时报警:初效过滤器的压差80pa, 1.防火调节阀与送、排风机联锁, 当风管内空气温度达到70c时, 防火调节阀自动关闭,同时切断送、排风机 22.2c时,d2开大。 冬季:室内温度由蒸汽电动二通阀d2控制(f1全开,f2关闭)。温度高于24.2c 时,d2关小;温度低于 夏季:室内温湿度由冷冻水电动二通阀d1,电动风阀f1、f2控制,湿度优先。湿度高于60%时,d1开大; 湿度低于50%时,d1关小。如果室内湿度在5060%范围内,而温度低于24.6c时,风阀f1关小, f2开大;温度高于26.6c时,f1开大,f2关小,至f2全关后,如温度仍高于26.6c,再开大d1。 室内湿度由电动干蒸汽加湿器d3控制。湿度高于50%时,d3关小;湿度低于40%时,d3开大。 中效过滤器的压差160pa时报警。 power of the air supplying and exhausting units manually. 3.室内温湿度控制: 调节阀, 并切断送、排风机电源。 3as built drawing 竣工图2001.6 编制人: 9000 174000 圆片存放间 qre lab 9000 8300 36000 81000 9000 a 9000 12 a a 1 250 9000900065002500 345 4 1 9000 5 1 6 6 1 7 -0.200 9000 8000 9000 3450 9000 b c 9000 d 8000 2a 1b 8000 1c d 1 9000 e f 9000 g h 9000 纯水间 e waterdi. plating 焊脚处理实验室 lab spare room 备用间 plating 焊脚处理间 纯水站 rodi control room 控制室 ahu. 3 空调机房3 adi cleaning room 2 j1万 净化间2 化学品制备间 bcds wet station quality control 质量控制间 quality control 质量控制间 cal room 空调机房2 ahu. 2 cleaning room 1 净化间1 9000 j k elec. switch 变配电间 sem/edx rie room 冷冻机房 cold .comp corridor gowning 二次更衣室 走廊 computer room 9000 12 90009000 9 9000 8 7 1 9 8 11 9000 1011 900090009000 1314 9000 1516 1000 -1.200 2000.9 1/200 s31dlbx2 3 14a/15 施 s72-1-14a 90009000 1718 90003000 192120 医务室 nurse sation dc when the temperature is lower than 23.4c,turn down d3. (2) in winter,indoor temperature is controlled by steam electric two-way valve d2 and d4.when the temperature is higher than 22.2c,turn down d4 until d4 is completely closed,then turn down d2;when the temperature is lower than 20c,turn up d2 until it is completely turned up,then turn up d4. indoor humidity is controlled by electric steam humidifier d5.when indoor humidity is higher than 55%, turn down d5; when the humidity is lower than 40%,turn up d53. 1.防火调节阀与送.排风机联锁,当风管内空气温度达到70c时,防火调节阀自动关闭,同时切断送.排风机电源,并将信号传至值班室。另外,当消防值班室接到火警信号时,也可由消防人员手动远距离关闭防火调节阀,并切断送.排 风机电源。 1.fire resisting-dampers should be interlocked with the air supplying units and the air exhausting units.when the temperature in the air pipe reaches 70c, the dampers will be shut off automatically,and at the same time the power of air supplying and exhausting units will be also shut off.the signal will be delivered to the duty room. when fire signal is received in the duty room, the on-duty worker can shut off the fire resisting dampers and cut off the power of the air supplying and exhausting units manually. 2.空调系统的初效.中效.高效过滤器的压差受到监测,当过滤器阻力大于下列值时报警:初效过滤器的压差80pa,中效过滤器的压差160pa,高效过滤器的压差500pa时报警。 2.the pressure difference of the preliminary filter and the middle filter and the high filter is monitored.when the resisting pressure difference of preliminary filter is more than 80 pa or the data of the middle filter is more than 160 pa or the data of the high filter is more than 500 pa,give out the alarming signal. 3.室内温湿度控制: 夏季:室内温度由冷冻水电动二通阀d2控制。温度高于25.6c时,d2开大;温度低于23.4c时,d2关小。 室内湿度由冷冻水电动二通阀d1控制。湿度高于65%时,d1开大;湿度低于55%时,d1关小。 冬季:室内温度由蒸汽电动二通阀d3控制。温度高于22.2c时,d3关小;温度低于20c时,d3开大。 室内湿度由电动干蒸汽加湿器d4控制。湿度高于55%时,d4关小;湿度低于45%时,d4开大。 3.indoor temperature and humidity control: (1) in summer,indoor temperature is controlled by the two-way electric valve d2 on the chilling water pipe.when the temperature is more than 25.6c,turn up d2.when the temperature is lower than 23.4c, turn down d2. indoor humidity is controlled by the two-way electric valve d1.when the humidity is higher than 65%, turn up d1;when the humidity is lower than 55%, turn down d1. (2) in winter,indoor temperature is controlled by steam electric two-way valve d3.when the temperature is higher than 22.2c,turn down d3;when the temperature is lower than 20c,turn up d3. indoor humidity is controlled by electric steam humidifier d4.when indoor humidity is higher than 55%,turn down d4; when the humidity is lower than 45%,turn up d4. 4.送.排风机与新风电动阀f1联锁,启动时,先启动循环风机.新风电动阀f1,再开新风风机cr1-6,最后开排风机;关闭时,则反之。 4.air supplying and exhausting units are interlocked with outdoor air electric valve f1.when started,first turn on air supplying unit and outdoor air electric valve f1,then turn on outdoor air fan cr1-6,at last turn on exhausting fan.when closed,the sequence is contrary to the starting sequence. 5.室内正压由新风电动阀f1控制。当微正压传感器所测压力大于10pa时,关小新风电动阀f1;反之,开大新风电动阀f1。 5.indoor slight positive pressure is controlled by outdoor air electric valve f1.when the pressure detected by the slight positive pressure sensor is higher than 10 pa,turn down f1;when the data is lower than 10 pa,turn up f1. 6.新风机cr1-6.电动风阀f2.f3与冷水电动阀d1联锁,当d1开启时,f2关闭,f3打开,新风机cr1-6启动;当d1关闭时,则反之。 6.out air fan cr1-6,outdoor air electric valve f2f3 and two-way electric valve d1 on the chilling water pipe.when d1 is turned on,f2 is turned off and f3 is turned off and outdoor air fan is turned on.when d1is turned off,the sequence is contrary. (二).cr1-69空调系统 cr1-69 ahu system: 三.图例 legend: three-phase four-pole socket lighting transformer,placed above the false ceiling ceiling maintenance lamp mounted fluorescent lamp with electronic ballast and tld36w/54 tube and emergency power mounted fluorescent lamp with electronic ballast and tld18w/54 tube mounted fluorescent lamp with electronic ballast and tld18w/54 tube and emergency power zr-vv-4x35+16 32zr-vv-5x6 zr-vv-3x2.520 开孔安装外,均为+0.3m a 汞灯,1x175w,嵌入式安装,跟现有灯具型号一样 mecury lamp,the type is the same as the existing one,1x175w the instruction of power distribution and lighting and automatic control and legend 磁力启动器,msb9(1.6a),+1.3m exhausting fan starter instruction of power distribution and building no.1(main building) 电力.照明.自控总说明及图例 1号建筑(主厂房) s72-1-2a2a/15 3 lighting and automatic control and legend 1 2 (一).ahu1-1114控制原理 control principle of ahu1-1114: 1.防火调节阀与送.排风机联锁,当风管内温度达到70c时,防火调节阀自动关闭,同时切断送.排风机电源,并将信号传至值班室。 另外,当值班室接到火警信号时,也可由消防人员手动远距离关闭防火调节阀,并切断送.排风机电源。 1.fire resisting-dampers should be interlocked with the air supplying units and the air exhausting units.when the temperature in the air pipe reachs 70c,the damper will be shut off automatically,and at the same time the power of air supplying and exhausting units will be also shut off.the signal will be delivered to the duty room. when fire signal is received in the duty room, the on-duty worker can shut off the fire resisting dampers and cut off the power of the air supplying and exhausting units manually. 2.空调系统的初效.中效过滤器的压差受到监测,当过滤器阻力大于下列值时报警:初效过滤器的压差80pa,中效过滤器的压 差160pa时报警。 2.the pressure difference of the preliminary filter and the middle filter is monitored.when the resisting pressure difference of preliminary filter is more than 80 pa or the data of the middle filter is more than 160 pa,give out the alarming signal. (二).ahu1-1,2,15 控制原理 control principle of ahu1-1,2,15 室内温湿度控制: 夏季:室内湿度由冷冻水电动二通阀d1控制。湿度高于55%时,d1开大;湿度低于45%时,d1关小。 室内温度由冷冻水电动二通阀d3控制。温度高于25.6c时,d3开大;温度低于23.4c时,d3关小。 冬季:室内温度由蒸汽电动二通阀d2.d4控制。温度高于22.2c时,d4关小至全关后再关小d2;温度低于20c时,d2开大,至全开后再开大d4。 室内湿度由电动二通阀d5及电动干蒸汽加湿器d6控制。湿度高于50%时,d6先关小,至全关后再关小d5;湿度低于40%时,d5先开大,至全开后再开大d6。 3.indoor temperature and humidity control: (1) in summer,indoor humidity is controlled by the two-way electric valve d1 on the chilled water pipe.when the humidity is higher than 55%, turn up d1.when the humidity is lower than 45%, turn down d1.and indoor temperature is controlled by the two-way electric valve d3 on the chilled water pipe.when the temperature is higher than 25.6c,turn up d3;when the temperature is lower than 23.4c,turn down d3. (2) in winter,indoor temperature is controlled by steam electric two-way valve d2 and d4.when the temperature is higher than 22.2c,turn down d4 until d4 is completely closed,then turn down d2;when the temperature is lower than 20c,turn up d2 until it is completely turned up,then turn up d4. indoor humidity is controlled by the two-way electric valve d5 and the electric steam humidifier d6.when indoor humidity is higher than 55%,turn down d6 until it is completely closed,then turn down d6; when the humidity is lower than 40%,turn up d5 until it is completely opened,then turn up d6. 其余控制要求同ahu11114系统。the other control requirements are the same as the requirements of ahu1-1114 system. a 终端组合电器,pz30jm-6ii,内装c45n-1p(20a)一只,挂墙安装,+1.5m terminal box. there is one circuit breaker c45n-1p(20a) in it. control box of fire-resistant door,supplied by the producer 防火卷帘门控制箱,由生产厂家配套 3design modification 设计更改 2 22 4as built drawing 竣工图2001.6 编制人: 152409229715240 1 2 3 (50-0“)( 30 panels 10-1 1/8“=302-9 3/4“)(50-0“) 122777(402-9 3/4“) 30x3077 = tr1male female tr2 canteen office 1 payroll facility 1 facility 2 network rm (bcr) office 2 cr1 cr2cr3 cr4 cr5 cr6 security dmis it misc. recreation center lobby mail 15240(50-0“) (100-0“) b (50-0“) c 培训室1 培训室2 餐 厅 大 厅 邮件室 办公 1 办公 2 会议室1 会议室2会议室3 会议室4 会议室6 娱乐中心 会议室8 cr8 会议室7 cr7 n 会议室5 保安室 文控中心 备餐区 小卖部 设备间1 ad 设备间2 filename 文件名 xref file 引用文件 日期date签 署 暖 通 专 业 结 构 专 业 总 图 工 艺 建 筑 签 署签 署 给排水 专 业 供 电 气体动力 电 照 签 署 专 业 通 信 控 制 a0 s72-2-10a corporation as built date drawing no. intel technology (china) ltd c h i n a copyright 1996 intel corporation, all rights reserved this drawing contains information which is the property of intel corporation. this drawing is received in confidence and its contents may not be disclosed without the prior written consent of intel corporation. intel confidential c date 校对: final chk. by 总设计师: chief designer 审核: approvals review by design by 桥架布置图.网络间电力布线图及配电柜重复接地图 1:150 sbglqj.dwg 2000.6 文件名 file name 比例: scale 项目号: date 日期: project no. 0007003 10a/10 3 图号: 设计阶段 current revision 张号: page no. 2号建筑(临时办公房)building no.2(sprung building) drawing title: corporation r 图纸名称 shanghai preliminary design 初步设计 detailed drawings design 施工图 key plan revision description 2 1 rev. no.dateapproved 平面位置示意图 confidential edri # 9 lane90 , lanxi road, shanghai. prc 信息产业部电子第十一设计研究院 design license no. :2200051 eleventh design & research institute, m. i. i. 设计证书号 300x100槽式桥架 cable tray +3.2m 300x100槽式桥架 cable tray +3.2m 200x100槽式桥架 cable tray +3.2m 说 明 note: 所有的桥架均为xqj-1-1a槽式桥架,安装高度为+3.2m.安装时注意与其他专业相配合. all the cable trays are xqj-1-1a type of cable tray.the installation height is 3.2m.during installation,the installation of cable tray should cooperate with the installation of other pipes. 30480 15240 network rm (bcr) (e)(f)(g) (h) 16a bv-3x2.5 sc15 16a bv-3x2.5 sc15 16a bv-3x2.5 sc15 16a bv-3x2.5 sc15 16a bv-3x2.5 sc15 16a bv-3x2.5 sc15 16a bv-3x2.5 sc15 16a bv-3x2.5 sc15 16a bv-3x2.5 sc15 16a bv-3x2.5 sc15 16a bv-3x2.5 sc15 16a bv-3x2.5 sc15 16a bv-3x2.5 sc15 16a bv-3x2.5 sc15 16a bv-3x2.5 sc15 16a bv-3x2.5 sc15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1n7-id-12.5kw r80pa, 中效过滤器的压差160pa时报警。 (2)过渡季i i 时,新风比为10%,室内温度由冷冻水电动二通阀d1控制。温度高于26c 时, 1.空调系统的初效,中效过滤器的压差受到监测, 当过滤器阻力大于下列值时报警: 初效过滤器的 开度加大,至100%后,如温度仍高于26c,室内温度开始由冷冻水电动二通阀d1控制, 其动作过程同(1);温度低于22c时,f1、f2开度减小,至10%后,如温度低于20c, wh w hw h chilled water supply chilled water return 蒸汽 steam condensed water 凝结水 冷冻水供水 冷冻水回水 0.3mpa (q =75.5kw) g=125kg/h 热 g=30.2t/h 7c (q =175kw) 12c 冷 z m d2 d1 f3 m t=2026c 回风 32880m /h return air 3 排风 138032880m /h 新风 350035000m /h outdoor air exhaust air f1 m z m 3 3 t=2026c tr1 t=2026ct=2026c lobbymailcr1 f2 female 1060m /h t=2026c 1060m /h3 canteenmale 3 t=2026ct=2026c corridoroffice 1 wh 0.3mpa (q =75.5kw) 冷 7c (q =175kw) g=30.2t/h temperature and humidity sensor 温湿度传感器 图 例 legend 温度传感器 压差开关 temperature sensor pressure difference sensor chilled water return condensed water chilled water supply steam 蒸汽 冷冻水供水 凝结水 12c 冷冻水回水 z g=125kg/h 热 d2m d1m m f3 pp 1100m /h 送风 35000m /h supply air 3 回风 35000m /h3 return air 3 排风 350035000m /h 新风 350035000m /h exhaust air outdoor air mf1 z mf2 3 3 t=2026c payroll 1100m /h3 t=2026c office 1 33900m /h3 33900m /h3 送风 35000m /h supply air 3 m 模拟量输入 模拟量输出 模拟量输出 数字量输入 ai ao di do rvvp-5x1.0 rvvp-4x1.0 rvvp-4x1.0 rvvp-5x1.0 rvvp-3x1.0 rvvp-4x1.0 rvvp-3x1.0 rvvp-5x1.0 模拟量输入 数字量输入 模拟量输出 模拟量输出do di ao ai rvvp-5x1.0 rvvp-4x1.0 rvvp-4x1.0 rvvp-3x1.0 rvvp-5x1.0 rvvp-4x1.0 rvvp-5x1.0 rvvp-3x1.0 rvvp-4x1.0 rvvp-4x1.0 rvvp-3x1.0 rvvp-4x1.0 ahu2-1空调自动控制原理图ahu2-2空调自动控制原理图 现场控制器 ddc现场控制器 ddc rvvp-5x1.0 rvvp-5x1.0 rvvp-3x1.0 rvvp-3x1.0 rvvp-5x1.0 rvvp-5x1.0 filename 文件名 xref file 引用文件 日期date签 署 暖 通 专 业 结 构 专 业 总 图 工 艺 建 筑 签 署签 署 给排水 专 业 供 电 气体动力 电 照 签 署 专 业 通 信 控 制 a0 s72-2-8 corporation as built date drawing no. intel technology (china) ltd c h i n a copyright 1996 intel corporation, all rights reserved this drawing contains information which is the property of intel corporation. this drawing is received in confidence and its contents may not be disclosed without the prior written consent of intel corporation. intel confidential c date 校对: final chk. by 总设计师: chief designer 审核: approvals review by design by 空调控制原理图(一) s2kzyl1.dwg 2000.6 文件名 file name 比例: scale 项目号: date 日期: project no. 0007003 8/10 2 图号: 设计阶段 current revision 张号: page no. 2号建筑(临时办公房) building no.2(sprung building) drawing title: corporation r 图纸名称 shanghai preliminary design 初步设计 detailed drawings design 施工图 key plan revision description 2 1 rev. no.dateapproved 平面位置示意图 confidential 101 edri # 9 lane90 , lanxi road, shanghai. prc 信息产业部电子第十一设计研究院 design license no. :2200051 eleventh design & research institute, m. i. i. 设计证书号 t p th p thth t th thththththth a bb a local controller automatic control principle of ahu2-1 local controller analog input analog output digital input digital outputdigital output digital input analog output analog input automatic control principle of ahu2-2 control principle remarks 1.the pressure difference of the preliminary filter and the middle filter is monitored. when the resisting pressure difference of preliminary filter is more than 80pa or the data of middle filter is more than 160pa,give out the alarm signal. 2.the temperature and humidity signal detected by the temperature and humidity sensor will be sent to local controller ddc.after calculating,enthalpy will be given. 3.indoor temperature control:(fresh air enthalpy: iw, returning air enthalpy: ih) (1).in summer, when iwih, the ratio of fresh air is 10%, the indoor temperature is controlled by the two-way electric valve on chilled water pipe. when the temperature is higher than 26c, turn up d1. when the temperature is lower than 20c,turn down d1. till d1 is turned off, run the transition season control processing programme (2).in transition season, the indoor temperature is first controlled by electric air damper f1f3. when the temperature is higher than 26c, turn up f1 & f2. when the two dampers are turned on completely and if the temperature is still higher than 26c, the indoor temperature is controlled by the two-way electric valve d1 on the chilled water pipe. this control process is the same as that in note(3). when the temperature is lower than 22c, turn down f1 & f2. when the opening of the damper is 10% and if the temperature is lower than 20c, run the winter control processing programme. that is the same as which is noted in (3). (3).in winter, when iwi 时,新风比为10%,室内温度由冷冻水电动二通阀d1控制。温度高于26c 时, (3)冬季i 80pa, 中效过滤器的压差160pa时报警。 ahu2-35空调原理说明 wh wh wh p chilled water return chilled water supply condensed water steam 蒸汽 凝结水 冷冻水供水 冷冻水回水 g=30.2t/h 热 7c (q =175kw) 12c 冷 mf1 回风 32650m /h return air 3 z 回风 35000m /h3 排风 350035000m /h return air 3 新风 350035000m /h outdoor air exhaust air 3 35000m /h 35000m /h t=2026c office 2 3 3 送风 35000m /h supply air 3 30
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 五年级数学(小数乘除法)计算题专项练习及答案汇编
- 中考数学总复习《 圆》测试卷附参考答案详解(黄金题型)
- 自考专业(人力资源管理)综合提升测试卷【夺冠】附答案详解
- 中级银行从业资格之中级银行业法律法规与综合能力题库检测题型含完整答案详解【夺冠】
- 重难点解析四川成都市华西中学7年级数学下册第一章整式的乘除综合测评试卷(含答案详解)
- 2025年城市危旧房改造社会稳定风险评估指标体系与方法研究
- 电竞公司转授权管理办法
- 自考专业(护理)每日一练试卷附答案详解【预热题】
- 重难点自考专业(学前教育)【满分必刷】附答案
- 注册公用设备工程师检测卷及参考答案详解(综合卷)
- GB/T 19851.12-2025中小学体育器材和场地第12部分:学生体质健康测试器材
- 公安科技信息化课件
- 桥梁工程支架浇筑连续箱梁的施工监理实施细则
- T∕CITS 146-2024 尿液有形成分名称与结果报告规范化指南
- 07HBP与OD、TD、LD区别培训课件
- 2023年安徽师范大学医院高校医学专业毕业生招聘考试历年高频考点试题含答案解析
- 经典分镜教程-电影分镜头画面设计机位图设计课件
- 心衰病患者护理查房课件
- JJF1101-2019环境试验设备温度、湿度校准规范-(高清现行)
- TSG11-2020 锅炉安全技术规程
- 水泥化学分析方法培训精品课件
评论
0/150
提交评论