




免费预览已结束,剩余72页可下载查看
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
摘要本次毕业设计题目为郡原美村1#楼电气设计,本工程为地上6层的三类低层民用住宅楼。课题的相关设计内容包括建筑电气设计的强电、弱电和消防部分设计。它包括用电负荷计算、电气照明及插座、防雷与接地、可视对讲系统设计、有线电视系统设计、电话系统设计、网络系统设计。本工程为三级供电,采用高低压配电房引来主用电源和备用电源供电,配电电压为380/220V。接地型为TN-C-S系统。每套住宅设置电度表计量用电量,集中安装在底层单元总配电箱。配电方式采用放射式。户内照明采用吸顶座灯,插座分为一般插座、空调插座、卫生间插座、厨房插座、冰箱插座和油烟机插座等。防雷为三类防雷设置避雷设施,接地采用联合基地装置。住宅单元入口处设置访客对讲系统。有线电视系统采用分配分支方式,用户输出口信号电平都为684dB,信号由多模光纤引自广播电视局有线电视网。本次设计旨在综合应用及巩固在校期间所学的基本知识和技能,熟悉设计工作基本方法及设计思想,加深对理论知识的理解,为今后的工作打下一定的基础。关键词:配电系统;照明;负荷计算;防雷接地;弱电系统IVAbstractThe graduation design topic is JunYuan Beautiful Village1 # building electrical design, this project for the ground 6 layers of the third level of high residential building. Subject related design content including building electrical design of strong current, weak current and fire system design. It includes electricity load calculation, electric lighting, socket, lightning protection and grounding, the visual talk-back system design, cable television system design, telephone system design, network system design.This project is a thirdly power supply, using high and low voltage transformer room from the main power supply and backup power supply, power distribution voltage for 380/220 V. Grounding type is TN-C-S system. Each set electricity meter measuring electricity consumption, the total distribution box installed in the bottom unit. The way of supply power is using radial distribution. Indoor lighting using suction cap lamp, socket is divided into general socket, air conditioning, bathroom, kitchen socket outlet, refrigerator and lampblack machine outlet socket. Lightning protection for the third class lightning protection facilities, adopt combination base grounding device. Residential unit set visitors intercom at the entrance. Cable TV system adopts branch distribution method, the user output signal level for 68 4 db, quotations from bureau of radio and television signals by multimode fiber cable networks.The design seeks to integrate application and consolidate the basic knowledge and skills which we learned during school, familiar with the basic method of design and design thinking, deepen our understanding of theoretical knowledge, laying a foundation for the future work.Key words: Distribution systems;lighting;load calculation;lightning proof grounding;weak current system目 录第一章 前言11.1 建筑电气概况11.2 设计原则11.3 设计内容2第二章 照明系统设计52.1 照明设计的要求52.2照明设计的目的和原则52.3照明的方式和种类52.3.1照明的方式52.3.2照明种类62.4照明灯具的选择62.5照度计算62.6 小结20第三章 开关和插座的设计213.1开关、插座安装规定213.1.1开关安装规定213.1.2插座安装规定213.2插座系统设计213.2.1插座设计规范213.2.2本工程插座设计223.3 小结26第四章 供配电系统设计274.1建筑供配电的负荷分级及其对供电要求274.2断路器的选择274.3导线和电缆截面选择284.4 线路敷设294.4.1线路敷设方式294.4.2金属管布线294.4.3导线穿管要求294.5负荷计算304.5.1负荷计算内容304.5.2计算负荷的方法304.6本工程负荷计算和选线304.7 小结46第五章 防雷接地系统设计475.1 建筑物的防雷分类475.2本建筑物年预计雷击次数计算485.3本工程防雷设计495.4过电压及接地505.4.1接地种类505.4.2 接地保护505.4.3 接地保护的类型515.5本工程接地设计535.6小结53第六章 有线电视系统设计546.1有线电视系统构成546.2有线电视分配系统546.3本工程有线电视系统设计546.4 小结58第七章 网络、电话系统设计607.1网络系统设计方案607.2本工程宽带网络系统设计607.3 电话系统概述607.4电话系统的设计原则607.5 电话线路的敷设617.6 本工程电话系统的设计617.7 小结61第八章 可视对讲系统设计628.1可视对讲系统概述628.1.1 系统组成628.1.2 设计原则628.2 本工程可视对讲设计638.2.1 本工程设备组成638.2.2 本工程安装638.3 小结64第九章 技术经济分析65第十章 结论66参考文献67谢辞68附录一 中文译文附录二 外文资料原文附录三 图纸沈阳建筑大学毕业设计郡原美村1#楼电气设计第一章 前言1.1 建筑电气概况建筑电气技术的发展,是随着建筑技术的发展,电气科技的发展而同步的。建筑电气技术是以电能、电子、电器设备及电气技术为手段来创造、维持和改善人民居住或工作的生活环境的电、光、声、冷和暖环境的一门跨学科的综合性的技术科学。它是强电和弱电与具体建筑的有机结合。由于技术发展和时代进步,人们的要求越来越高,使得建筑开始走向高品质,我们的设计也要和时代跟进。随着我国城镇建设扩大和发展,住宅建筑多样化、高层化、集群(小区)化是必然趋势,建筑电气设计与安装逐渐数字化、综合化方向发展。因此,完整的住宅电气设计是指由用户开始到小区建筑群结束所涉及的相关电气设计。需要强调的是,现代住宅电气设计,无论设计思想、技术、产品选择等诸方面,与传统大相径庭。人们在追求舒适、安全的居住环境的同时,对建筑电气的设计和安装业提出了一些节能设计的措施展开讨论。建筑电气作为一个专业,从无到有,由简单而复杂,发展到如今已经囊括了兼之强电和弱电在内的多个系统,并且随着以IT业为龙头的科学技术的发展,及其在建筑业的应用,综合弱电项目的智能电气更是突飞猛进。特别是近年来绿色建筑、智能建筑的兴起,使得现代计算机技术、现代控制技术、网络技术和现代通信技术在建筑电气领域取得了广泛的应用,使得建筑更加节能、环保,安全。在工程实践中,伴随着不断暴露的问题和解决问题的过程,建筑电气必将日趋成熟和发展健全;在避免二次投资造成浪费的同时,走向专业化、正规化和规范化。1.2 设计原则本次设计为郡原美村1#为三类民用建筑,地上6层。设计需做到方案合理、技术先进、运行可靠、满足相关规范的要求,还要简捷实用、便于操作、管理和维护,减少综合投资。并应结合当地供电、施工、房管等具体条件,选用的各类设施、器件除应考虑产品容量、质量、安全性、便于维护和管理等因素外,还应为日后用电水平的增长,留有裕量。有条件时,可考虑选用节电智能型产品。即:(1)满足建筑物的使用功能;(2)考虑实际经济效益;(3)节省无谓消耗的能量。1.3 设计内容由于技术发展和时代进步,人们的要求越来越高,使得建筑开始走向高品质,我们的设计也要和时代跟进。此课题是关于建筑电气工程的设计课题,该课题来源于设计院的实际工程项目,本课题的相关设计内容包括建筑电气设计的强电、弱电部分设计。本设计将所学专业课程的理论知识与具体的工程实际相结合,熟练应用CAD绘图的基本技巧记忆建筑电气的施工程序,了解供配电系统的进线、配线方式,负荷计算及设备型号选择,照明系统的灯具选择和开关控制等项目,了解并初步掌握低层建筑电气设计的内容、步骤和方法,初步掌握低层建筑电气设计的相关规范,让学生对本专业所学的内容进行一次集中、系统、全面的复习、总结和完善,更好地掌握本专业的基本理论和基本技能,为以后所从事的工作打下基础。其中强电,弱电的主要设计内容是:(1) 强电部分主要内容包括:配电系统图设计;住宅用电负荷计算;照明配电平面图设计(包括照明及插座的设计);防雷与接地布置图设计;电气设计说明。(2) 弱电部分主要内容包括:弱电平面图设计(包括电视、电话、网络、访客可视对讲的设计);弱电系统图设计。本设计图纸共14张,包括图纸目录,图例、主要设备材料表;设计说明;强电部分和弱电部分。用电负荷计算:采用需用系数法计算并确定用户的计算负荷和短路电流,并将其作为选择断路器、电线电缆、电度表等低压电器设备的依据。电气照明及插座:根据规范要求对住宅内的灯具和插座进行布置,照明的灯具使用一个回路供电,还有普通、厨房、卫生间、空调等插座分别由单独回路供电。防雷与接地:根据年预计雷击次数,为此按三级防雷建筑设计:本工程按三类防雷建筑设置避雷设施,接地采用联合接地装置,并设置总等电位联接。接闪器:采用25*4镀锌扁钢沿屋面女儿墙或者隔墙顶贴装做避雷带,并在屋面焊接成不大于20m*20m、24m*16的网格,避雷带的支持卡间距为1m(转角处0.5m)。凡突出屋面的所有金属构件均应与避雷带可靠焊接。引下线:利用建筑物钢筋混凝土柱子内两根16以上主筋通长焊接作为引下线,上端与避雷带相连下端与基础钢筋相连。接地体做法为:利用建筑物基础和桩基内钢筋做接地体,将基础柱圈梁上下两层主筋沿基础外圈梁焊接成环形并将主轴线上的地梁上下两层主筋相互焊接成网做接地体。本建筑采用总等电位连接,各种引入。引出建筑物的金属管道均与就近的总等电位联结可靠联结。测试点:建筑物四角的外墙引下线在室外地面0.5米处设测试点,本工程防雷接地,安全保护接地及各种弱电系统接地共用接地装置,接地电阻要求不大于1欧姆,否则应增加接地体。凡正常不带电,而当绝缘破坏有可能呈现电压的一切电气设备金属外壳均应可靠接地。施工时应注意:焊接的搭接长度应满足施工规范的要求,焊接点应饱满,无虚焊、夹砂,焊接后应除尽药皮,埋地的焊接点应吐沥青漆防腐。可视对讲系统设计:本工程在住宅单元入口处设置访客对讲主机。各住户内设置访客对讲分机燃气泄漏探测器,对讲系统通过联网器与小区访客对讲系统联网。在火灾时能够通过自动报警系统对对讲门电控锁自动解锁。住户还可以通过本系统看到访客并与之对话确认对方身份。有线电视系统设计:电视信号采用多模光纤由广播电视局引来,在一楼设立电视器件箱,在住宅内设立电视插座,电视支线在楼梯间墙内敷设至索要引至的楼层后,穿塑料管在地板内敷设各户家庭综合信息接线箱。经过家庭综合信息接线箱分线至各电视插座。本设计仅供预埋管线使用,放大器、分频分支器选型参数根据有线电视网的设计要求。电话系统设计:电话由电信局采用HYA型电话电缆引来电话信号,在一层设置电话分线箱。电话支线采用HYA型导线在楼梯间墙内敷设至所要引上的楼层后穿塑料管暗敷设至家庭综合信息接线箱,由家庭综合接线箱引出的电话支线穿塑料管敷设至各个电话插座,其中一到六层标准层每户两个电话插座。网络系统设计:本工程网络信号自电信局引来,在单元一层楼梯间设置计算机网络配线箱。网络进线采用2芯62.5/125m多模光纤穿钢管引入。各套住宅的客厅和卧室设置计算机网络插座,由一层楼梯间内计算机网络分线箱引出的网络用户分支线采用HYUTP型五类四对对绞电缆在金属线槽内至各楼层。然后穿塑料管在地板内敷设至家庭多媒体箱,户内线路穿塑料管暗敷设,宽带网络出线盒均底边距地0.3m。本工程的主要设计依据是:(1) 相关专业提供给的工程设计资料;(2) 甲方提供的设计任务书及设计要求;(3) 中华人民共和国现行主要标准及法规:民用建筑电气设计规范(JGJ/T16-2011);建筑物防雷设计规范(GB50057-2011)(2011版);低压配电设计规范(GB50054-2011);供配电系统设计规范(GB50096-2012);住宅设计规范(GB50096-2011)(2011版);火灾自动报警系统设计规范(GB50116-2011);建筑照明设计标准(GB50034-2012);高层民用建筑设计防火规范(GB50045-2011)(2011版)等。还有其它有关国家及地方的现行规程、规范及标准。68第二章 照明系统设计2.1 照明设计的要求住宅(公寓)照明宜选用细管径直管荧光灯或紧凑型荧光灯。当因装饰需要选用自炽灯时,宜选用双螺旋白炽灯。灯具的选择应根据具体房问的功能而定,宜采用直接照明和开启式灯具,并宜选用节能型灯具。在住宅照明设计中,应根据使用性质,功能要求和使用条件,按不同标准分别取值。住宅内照度标准所规定的照度,是指工作面上的平均维护照度,若设计未加指明时,以距地0.75m的参考水平面作为工作面。2.2照明设计的目的和原则照明设计的原则如下:(1) 使用性原则,使用是根本也是设计的出发点和基本条件。使用性还包括照明系统的施工安装、运行几维修的方便简单,及对未来照明发展变化留有一定的空间。(2) 安全性原则,在选择设计照明系统时要自始至终坚持安全第一的原则。在设计中要遵循规范的规定和要求,严格按规范设计。(3) 经济性原则,一方面是节能,另一方面是节约1。2.3照明的方式和种类2.3.1照明的方式照明器按其布局方式或使用功能而构成的基本方式,称为照明方式。一般分为一般照明、分区一般照明、局部照明和混合照明四种。(1) 一般照明:为使整个照明场地获得均匀明亮的水平照度,使用照明器在整个照明场所基本均匀布置的照明方式。(2) 分区一般照明:根据需要提高特定区域照度的一般照明。根据工作面布置的实际情况,将照明器集中或分区集中均匀的布置在工作区上方,使室内不同被照面上产生不同的照度,可以有效的节约能源。(3) 局部照明:以满足照明范围内某些部位的特殊需要而设置的照明称为局部照明。它仅限于照亮一个有限的工作区,通常采用从最适合的方向装设台灯、射灯或反射灯型灯泡。其优点是灵活、方便、节电、能有效地突出重点。(4) 混合照明:由一般照明和局部照明共同组成的照明称为混合照明。其实质是在一般照明的基础上,在另外需要提供特殊照明的局部,采用局部照明。2.3.2照明种类照明种类分为正常照明、应急照明、值班照明、警卫照明、障碍照明、装饰照明和艺术照明。(1) 正常照明:为满足正常工作而设置的室内外照明称为正常照明。它起着满足人们基本视觉要求的功能,是照明设计中的主要照明。它可以单独使用,也可与事故照明、值班照明同时使用,但控制线路必须分开。(2) 应急照明:在正常照明因故障熄灭后,提供事故情况下继续工作或人员安全或顺利的照明称为应急照明。它包括备用照明、安全照明和疏散照明三种。(3) 值班警卫照明:供值班和警卫人员使用的照明。可利用正常照明能单独控制的一部分,或利用事故照明的一部分或全部作值班照明。(4) 障碍照明:装设在建筑物上作为障碍标志用的照明。在飞机场周围较高的建筑物上或有船舶通行的航道两侧的建筑物上,应按民航和交通部门的有关规定装设障碍照明灯。2.4照明灯具的选择室内照明光源的确定,应根据使用场所的不同,合理地选择光源的光效、显色性、寿命、启动点燃和再点燃时间等光电特性指标以及环境条件对光源光电参数的影响1。灯具的选择是照明设计的基本内容之一,其选择恰当与否,直接影响到照明的质量、经济性能和耗能指标的好坏。(1) 住宅照明灯具的选择以普通节能灯为主;(2) 卫生间等潮湿环境要求采用防潮灯具、开关宜安装于浴室外或采用防潮防水型面板;(3) 在高温场所,宜采用散热性能好、耐高温的灯具;(4) 在易受机械损伤、光源自行脱落可能造成人员伤害或财物损失的场所使用的灯具,应有防护措施;住宅的公共走道、走廊、楼梯间应设人工照明。2.5照度计算照度计算是照明设计的重要内容之一,照度计算的目的,是根据所需要的照度值和其它已知条件来确定灯泡的容量或灯具的数量。本次设计应用需用系数法进行照度计算。照度标准值:在民用建筑照明设计中,应根据建筑性质、建筑规模、等级标准、功能要求和使用条件等依据下表。表2-1 节能灯单位面积安装功率计算高度(m)房间面积(m2)节能灯照度(lx)3050751001502002310151525255050150150300300以上2.52.11.81.71.61.54.23.63.12.82.62.46.25.44.84.33.93.28.37.26.45.75.24.912.510.99.58.67.87.316.714.512.711.510.49.7参照国家标准:建筑照明设计标准GB 50034-2004,得知表2-2。 表2-2 住宅建筑照明标准值房间或场所参考平面及其高度照度标准值(lx)Ra起居室一般活动0.75m水平面10080书写、阅读0.75m水平面300*卧 室一般活动0.75m水平面7580床头阅读0.75m水平面150*餐 厅0.75m餐桌面15080厨房一般活动0.75m水平面10080操作台台 面 150*卫 生 间0.75m水平面10080注: * 宜用混合照明房间或场所照明功率密度(W/m2)对应照度值(lx)现行值目标值起居室76100卧室75餐厅150厨房100卫生间100表2-3 住宅建筑照明的照度标准值表2-4 飞利浦灯具利用系数(部分数据)有效顶棚反射系数/%807050墙反射系数/%503010503010503010地面反射系数/%202020室空间系数20.640.600.580.620.590.580.600.570.5630.570.530.510.560.520.500.540.510.4940.520.470.450.510.460.440.490.450.4450.470.420.400.460.410.390.450.410.3960.430.380.360.420.370.320.350.410.3770.390.340.320.390.340.320.380.330.3280.360.310.290.360.310.290.350.300.2990.330.280.260.330.280.260.320.280.26100.310.260.240.300.260.240.300.260.24 20% 时的修正系数如下表2-5:表2-5修正系数有效顶棚反射系数/%807050墙反射系数/%503010503010503010有效地面反射率=30%室空间系数11.0821.0751.0681.0701.0641.0591.0491.0441.04021.0661.0551.0471.0571.0481.0391.0411.0331.02731.0541.0421.0331.0481.0371.0281.0341.0271.02041.0451.0331.0241.0401.0291.0211.0301.0221.01551.0381.0261.0181.0341.0241.0151.0271.0181.01261.0331.0211.0141.0301.0201.0121.0241.0151.00971.0291.0181.0111.0261.0171.0091.0221.0131.00781.0261.0151.0091.0241.0151.0071.0201.0121.00691.0241.0141.0071.0221.0141.0061.0191.0111.005101.0221.0121.0061.0201.0121.0051.0171.0101.004照度计算如下:计算每单位被照面积所需的灯泡安装功率:P=WA 2-1式中: P 全部灯泡的安装功率,瓦;A 被照面积,平方米;W 单位面积安装功率,瓦。计算灯泡个数:N=W/P 2-2式中:N 该计算房间内灯的安装个数;W 该计算房间内总的安装功率; P 每只灯的总功率。对于每个灯具来说,由光源发出的额定光通量与最后落到工作面上的光通量之比值称为光源光通量利用系数(简称利用系数)。U= 2-3式中:U 利用系数; 由灯具发出的最后落到工作面上的光通量,lm; 每个灯具中光源额定总光通量,lm。有了利用系数的概念,则室内平均照度即可由下式计算2: 2-4或 2-5式中:Eav 工作面平均照度,lx; 每个灯具中光源的额定总光通,lm;N 灯具数;U 利用系数;A 工作面面积,;K 维护系数,一般住宅选用0.8 ,维护系数K是考虑到灯具在使用过程中由于光源光通量的衰减、灯具和房间的污染而引起照度下降。室空间系数:RCR= 2-6顶棚空间系数:CCR= 2-7地板空间系数: FCR= 2-8式中:l 室长,m;w 室宽,m; 室空间高,m; 顶棚空间高,m; 地板空间高,m。 2-9式中:Ao 顶棚(或地版)平面面积,;As 顶棚(或地版)空间内所有表面的表面积,; 顶棚(或地版)空间各表面的平均反射比。假设空间由i各表面组成,以Ai表示第i各表面面积,以表示地i各表面的反射比,则平均反射比由下式求出: 2-10A 户型 S=67.4m2卧室面积A=11.9 ,照度选择 E=75lx,查表得 W=4W/,P=WA=47.6W,吸顶灯每盏40W,N=47.6/(40+405%)1.13。 采用飞利浦吸顶灯40W一盏。校验:卧室长L=3.6m,宽W=3.3m,高H=2.8m,工作面高度=0.75m,室空间高度为=2m,窗户尺寸为1.5m1.8m,窗户反射比为0.1,顶棚反射比为0.8,墙反射比为0.5,地面反射比为0.3。灯具为吸顶节能灯,功率为40W,光通量为2720lm,照度要求为75lx。室空间比: RCR=5.81墙面平均反射系数:0.45地板空间平均反射比:0.39地板空间等效反射系数: 0.25根据=0.8,按0.5算,查表2-4得:RCR=5,U=0.47;RCR=6,U=0.43。用内插法求得RCR=5.81,U0.46。0.2,按0.3计算,查表2-5得:RCR=5,K=1.038;RCR=6,K=1.033;由内插法得RCR=5.81,K=1.037。U=1.0370.46=0.47787.2lxEav/E标准116.3%可知一盏飞利浦40W吸顶灯可以满足照度要求。主卧室面积A=15.5 ,照度选择 E=75lx,查表得 W=4.5W/,P=WA=69.75W,吸顶灯每盏72W,N=69.75/(72+725%)0.92。采用飞利浦吸顶灯72W一盏 校验:卧室长L=4.5m,宽W=3.45m,高H=2.8m,工作面高度=0.75m,室空间高度为=2m,窗户尺寸为1.5m1.8m,窗户反射比为0.1,顶棚反射比为0.8,墙反射比为0.5,地面反射比为0.3。灯具为吸顶节能灯,功率为72W,光通量为2720lm,照度要求为75lx。室空间比: RCR=5.1墙面平均反射系数: 地板空间平均反射比: 0.39地板空间等效反射系数: 0.27根据=0.8,按0.5算,查表2-4得:RCR=5,U=0.47;RCR=6,U=0.43。用内插法求得RCR=5.4,U0.434。0.2,按0.3计算,查表2-5得:RCR=5,K=1.038;RCR=6,K=1.033。由内插法得RCR=5.4,K1.036。U=1.0360.434=0.45063.174xEav/E标准84.2%可知一盏飞利浦72W吸顶灯可以满足照度要求。卫生间面积A=4.4,照度选择 E=100lx,查表得 W=4.5W/,P=WA=19.8W,防尘吸顶灯每盏22W,N=19.8/(22+225%)1。采用飞利浦防尘吸顶灯22W一盏。校验:房间长L=2.2m,宽W=2m,高H=2.8m,工作面高度=0.75m,室空间高度为=2m,无窗,顶棚反射比为0.8,墙反射比为0.5,地面反射比为0.3。灯具为防尘吸顶节能灯,功率为22W,光通量为1500lm,照度要求为100lx。室空间比: RCR=9.5墙面平均反射系数: 地板空间平均反射比: 0.42地板空间等效反射系数: 0.23根据=0.8,=0.5,查表2-4得:RCR=9,U=0.33;RCR=10,U=0.31。用内插法求得RCR=9.8,U0.316。按0.2计算,不需修正。91.8lxEav/E标准91.8%可知一盏飞利浦22W防尘吸顶灯可以满足照度要求。 厨房面积A=4.8,照度选择 E=100lx,查表得 W=4.5W/,P=WA=21.6W,防尘吸顶灯每盏22W,N=21.6/(22+225%)1。采用飞利浦防尘吸顶灯22W一盏。校验:房间长L=3m,宽W=1.6m,高H=2.8m,工作面高度=0.75m,室空间高度为=2m,窗户尺寸为1.5m1.8m,窗户反射比为0.1,顶棚反射比为0.8,墙反射比为0.5,地面反射比为0.3。灯具为吸顶节能灯,功率为22W,光通量为1500lm,照度要求为100lx。室空间比: RCR=9.6墙面平均反射系数: 0.45地板空间平均反射比: 0.42地板空间等效反射系数: 0.23根据=0.8,按0.5算,查表2-4得:RCR=8,U=0.36;RCR=9,U=0.33。用内插法求得RCR=7.7,U0.35。按0.2计算,不需要修正。87.5lxEav/E标准=87.5%可知一盏飞利浦32W防尘吸顶灯可以满足照度要求。客厅面积A=24 ,照度选择 E=100lx,查表得 W=4.5W/,P=WA=108W,吸顶灯每盏75W,N=108/(75+755%)1.2。采用飞利浦吸顶灯75W一盏。 校验:房间长L=6.2m,宽W=4.7m,高H=2.8m,工作面高度=0.75m,室空间高度为=2m,窗户尺寸为1.5m1.8m,窗户反射比为0.1,顶棚反射比为0.8,墙反射比为0.5,地面反射比为0.3。灯具为吸顶节能灯,功率为75W,光通量为5320lm,照度要求为100lx。室空间比: RCR=4.5墙面平均反射系数:0.47地板空间平均反射比:0.38地板空间等效反射系数: 0.27根据=0.8,按0.5算,查表2-4得:RCR=4,U=0.52;RCR=5, U=0.47。用内插法求得RCR=6.88,U0.490.2,按0.3计算,查表2-5得:RCR=4,K=1.045;RCR=5, K=1.038。用内插法求得RCR=6.88,K1.041U=1.0410.49=0.5190.44lxEav/E标准=90.44%可知一盏飞利浦75W吸顶灯可以满足照度要求。阳台1面积A=2.8,照度选择 E=75lx,查表得 W=4W/,P=WA=11.2W,嵌入式天棚灯每盏13W,N=11.2/(13+135%)0.82。 采用飞利浦嵌入式天棚灯13W一盏。 阳台2面积A=4,照度选择 E=75lx,查表得 W=4W/,P=WA=16W,嵌入式天棚灯每盏18W,N=16/(18+185%)0.85。 采用飞利浦嵌入式天棚灯18W一盏。B 户型卧室面积A=11.8,照度选择 E=75lx,查表得 W=4W/,P=WA=47.2W,吸顶灯每盏40W,N=47.2/(40+405%)1.12。 采用飞利浦吸顶灯40W一盏。主卧室面积A=12,照度选择 E=75lx,查表得 W=4W/,P=WA=48W,吸顶灯每盏40W,N=48/(40+405%)1.14。采用飞利浦吸顶灯40W一盏。 厨房面积A=4.5,照度选择 E=100lx,查表得 W=4.5W/,P=WA=20.25W,防尘吸顶灯每盏22W,N=20.25/(22+225%)0.88。采用飞利浦防尘吸顶灯22W一盏。卫生间面积A=3.2,照度选择 E=100lx,查表得 W=4.5W/,P=WA=14.4W,防尘吸顶灯每盏11W,N=14.4/(11+115%)1.25。 采用飞利浦防尘吸顶灯11W一盏。 客厅面积A=18.7,照度选择 E=100lx,查表得 W=4.5W/,P=WA=84.15W,吸顶灯每盏75W,N=84.15/(75+755%)1.07。采用飞利浦吸顶灯75W一盏。 阳台1面积A=3,照度选择 E=75lx,查表得 W=4W/,P=WA=12W,吸顶灯每盏11W,N=12/(11+115%)1.04。采用飞利浦嵌入式天棚灯11W一盏。阳台2面积A=2.6,照度选择 E=75lx,查表得 W=4W/,P=WA=10.4W,嵌入式天棚灯每盏11W,N=10.4/(11+115%)0.9。 采用飞利浦嵌入式天棚灯11W一盏。(3)C 户型卧室面积A=10.2,照度选择 E=75lx,查表得 W=4W/,P=WA=40.8W,吸顶灯每盏40W,N=40.8/(40+405%)0.97。 采用飞利浦吸顶灯40W一盏。主卧室面积A=14.6,照度选择 E=75lx,查表得 W=4W/,P=WA=58.4W,吸顶灯每盏40W,N=58.4/(40+405%)1.39。采用飞利浦吸顶灯40W一盏。 厨房面积A=4.7,照度选择 E=100lx,查表得 W=4.5W/,P=WA=21.15W,防尘吸顶灯每盏22W,N=21.15/(22+225%)0.92。采用飞利浦防尘吸顶灯22W一盏。卫生间面积A=3.4,照度选择 E=100lx,查表得 W=4.5W/,P=WA=15.3W,防尘吸顶灯每盏11W,N=15.3/(11+115%)1.32。 采用飞利浦防尘吸顶灯11W一盏。 客厅面积A=10.8,照度选择 E=100lx,查表得 W=4.5W/,P=WA=48.6W,吸顶灯每盏40W,N=48.6/(40+405%)1.16。采用飞利浦吸顶灯40W一盏。 阳台面积A=3,照度选择 E=75lx,查表得 W=4W/,P=WA=12W,吸顶灯每盏11W,N=12/(11+115%)1.04。采用飞利浦嵌入式天棚灯11W一盏。餐厅面积A=8.3,照度选择 E=150lx,查表得 W=5W/,P=WA=41.5W,嵌入式天棚灯每盏40W,N=41.5/(40+405%)0.99。 采用飞利浦嵌入式天棚灯40W一盏。(4)D 户型卧室面积A=13,照度选择 E=75lx,查表得 W=4W/,P=WA=52W,吸顶灯每盏40W,N=52/(40+405%)1.24。 采用飞利浦吸顶灯40W一盏。厨房面积A=4.3,照度选择 E=100lx,查表得 W=4.5W/,P=WA=19.35W,防尘吸顶灯每盏22W,N=19.35/(22+225%)0.84。采用飞利浦防尘吸顶灯22W一盏。卫生间面积A=3.2,照度选择 E=100lx,查表得 W=4.5W/,P=WA=14.4W,防尘吸顶灯每盏11W,N=14.4/(11+115%)1.25。 采用飞利浦防尘吸顶灯11W一盏。 客厅面积A=16,照度选择 E=100lx,查表得 W=4.5W/,P=WA=72W,吸顶灯每盏75W,N=72/(75+755%)0.91。采用飞利浦吸顶灯75W一盏。 阳台1面积A=3.4,照度选择 E=75lx,查表得 W=4W/,P=WA=13.6W,吸顶灯每盏11W,N=13.6/(11+115%)1.18。采用飞利浦嵌入式天棚灯11W一盏。阳台2面积A=2.1,照度选择 E=75lx,查表得 W=4W/,P=WA=8.4W,嵌入式天棚灯每盏11W,N=8.4/(11+115%)0.73。 采用飞利浦嵌入式天棚灯11W一盏。(5)E 户型卧室面积A=10.2,照度选择 E=75lx,查表得 W=4W/,P=WA=40.8W,吸顶灯每盏40W,N=40.8/(40+405%)0.97。 采用飞利浦吸顶灯40W一盏。主卧室面积A=14.6,照度选择 E=75lx,查表得 W=4W/,P=WA=58.4W,吸顶灯每盏40W,N=58.4/(40+405%)1.39。采用飞利浦吸顶灯40W一盏。 厨房面积A=4.5,照度选择 E=100lx,查表得 W=4.5W/,P=WA=20.25W,防尘吸顶灯每盏22W,N=20.25/(22+225%)0.88。采用飞利浦防尘吸顶灯22W一盏。卫生间面积A=3.4,照度选择 E=100lx,查表得 W=4.5W/,P=WA=15.3W,防尘吸顶灯每盏11W,N=15.3/(11+115%)1.32。 采用飞利浦防尘吸顶灯11W一盏。 客厅面积A=9.2,照度选择 E=100lx,查表得 W=4.5W/,P=WA=41.4W,吸顶灯每盏40W,N=41.4/(40+405%)0.99。采用飞利浦吸顶灯40W一盏。 阳台1面积A=3,照度选择 E=75lx,查表得 W=4W/,P=WA=12W,吸顶灯每盏11W,N=12/(11+115%)1.04。采用飞利浦嵌入式天棚灯11W一盏。公共照明灯具的选取此处不做设计。直接选取安全出口指示灯和单向疏散指示灯2.5W/盏,声控灯和管井间壁灯36W/盏。2.6 小结 本章节主要介绍了居民住宅的照明系统,讲述了照明系统的设计内容和一般规则。本工程是通过单位容量法进行照度计算,通过计算确定了不同房间的灯具个数、大小以及安装方式。灯具的种类是根据其作用和安装在不同房间来选择的,例如,在厨房的灯应让房间明亮,没有阴影,应选择防水防尘的灯具。 第三章 开关和插座的设计3.1开关、插座安装规定3.1.1开关安装规定(1) 接线开关距地面的高度一般为23m;距门口为150200mm;且拉线的出口应向下。(2) 扳把开关距地面的高度为1.2m,距门口为150200mm;开关不得置于单扇门后。(3) 暗装开关的面板应端正、严密并与墙面平;(4) 开关位置应与灯位相对应,同一室内开关方向应一致。3.1.2插座安装规定(1) 暗装和工业用插座距地面不应低于30cm;(2) 在儿童活动场所应采用安全插座。采用普通插座时,其安装高度不应低于1.8m;(3) 同一室内安装的插座高低差不应大于5mm,成排安装的插座高低差不应大于2mm;(4) 暗装的插座应有专用盒,盖板应端正严密并与墙面平。3.2插座系统设计3.2.1插座设计规范 根据民用建筑电气设计规范,插座设计有如下规定:(1) 当插座为单独回路时,数量不宜超过10个(组)。(2) 当灯具和插座混为一路过,其中插座数量不宜超过5个(组)。(3) 插座应由单独的回路配电,并且一个房间内的插座由同一路配电。(4) 在潮湿房间(住宅中的厨房除外)内,不允许装设一般插座,但设置有安全隔离变压器插座可除外3。表3-1 电源插座的设置要求及数量序号名称设置要求数量1起居室(厅)、兼起居的卧室单相两孔、三孔电源插座32卧室、书房单相两孔、三孔电源插座23厨房IP54单相两孔、三孔电源插座24卫生间IP54单相两孔、三孔电源插座15洗衣机、冰箱、排油烟机、排风机、空调器、电热水器单相三孔电源插座13.2.2本工程插座设计(1) 一到六层标准层 A户型客厅:两面对应的墙壁分别设置一个10A/250V的单相二、三孔插座(带保护门),距地0.3米。在靠近窗户处,设一个20A/250V的单相三孔插座作为柜式空调插座(带保护门),距地1.7米。厨房:设置一个防溅水型16A/250V的单相二、三孔插座(带保护门),作为电磁炉插座,距地1.5米。设置一个防溅水型10A/250V的单相二、三孔插座(带保护门)作为油烟机插座,距地2.2米。设置一个防溅水型16A/250
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 中国网络安全产品项目创业计划书
- 中国家庭治疗仪项目创业计划书
- 中国姬松茸项目创业计划书
- 中国CAE软件项目创业计划书
- 中国疾病远距检测项目创业计划书
- 中国观赏植物项目创业计划书
- 中国宁夏电子竞技项目创业计划书
- 中国高山反季节蔬菜项目创业计划书
- 安全教育考卷的题库及答案
- 2025年AI医疗行业发展现状、趋势、主要应用领域及相关标的分析报告
- 2025年民营经济发展的相关政策考试试题及答案
- 贵州国企招聘2025贵州省粮食储备集团有限公司招聘76人笔试参考题库附带答案详解析版
- 欠款购买材料合同协议书
- 网络安全基础知识试题及答案
- 第18课《文言文二则》(《铁杵成针》)公开课一等奖创新教学设计及反思
- 2025年透明质酸钠项目市场调查研究报告
- 检查与检验结果审核制度
- 陕09J01 建筑用料及做法图集
- 电感气隙计算方法
- 关于进一步理顺市区行政管理体制的调研报告5
- 现代护理管理工具的应用.ppt
评论
0/150
提交评论