全文预览已结束
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
Calibration of the focal plane detectors for a compact MPR neutron spectrometer with proton beam from HI-13 tandem accelerator Guoguang Zhangab*,Xia Lib , Ji Baob , Jianfu Zhanga, Long Houb ,Zuying Zhoub, aNorthwest Institute of Nuclear Technology, Xian, Shaanxi, 710024, P.R.C bChina Institute of Atomic Energy, Beijing, 102413, P.R.C ABSTRACT A new compact magnetic proton recoil (MPR) type spectrometer has been developed for diagnosing fusion neutrons. The designs of beam optics and focal plane detectors (FPD) of the MPR spectrometer are presented. The calibration experiment of the FPD, which is consisted of silicon micro strips, has been performed on the HI-13 tandem accelerator at China Institute of Atomic Energy (CIAE). The uncertainty of the measurement data is discussed. Keywords: focal plane detector, energy calibration, magnetic proton recoil spectrometer, beam optics 1. INTRODUCTION The magnetic proton recoil (MPR) spectrometer has been utilized in the measurement of the thermonuclear neutrons from a fusion reactor 1, 2. The instrument is based on the principle that neutrons can be converted to protons through elastic scattering in a proton-rich conversion foil and the fact that protons traveling in a magnetic field can be separated in space due to their momentum difference. When protons enter the magnetic spectrometer, momentum selection takes place and their energies can be deduced by their positions on a focal plane detector array at the exit of the spectrometer. The protons are only recoiled from the elastic scattering process and there is practically no other extraneous production of protons. Furthermore, only forward recoiled protons are used so the energy downshift is small. This helps obtaining good energy resolution and low background interference. This spatial distribution can be related back to neutron energy at the foil. The MPR spectrometer was installed at the Joint European Torus (JET) in 1996 and has provided diagnostics of mainly for high neutron yield rates from both deuterium-deuterium and deuterium-tritium plasmas since February 1997. The MPR weights about 90 tons including the surrounding concrete shielding that is needed for reducing background interference in the hostile environment of the Torus hall. A novel spectrometer for the measurement of neutrons has been designed for OMEGA and the NIF 3, 4. In this work, for solving the problems of fusion neutron energy measurement in a very limited space, a compact MPR type spectrometer has been developed at Northwest Institute of Nuclear Technology (NINT). The whole MPR weights only about 1.5 tons. The size of the MPR spectrometer is about 1.30.90.5 m3. A silicon PIN detector array, which consists of 40 micro strips, is used as the focal plane detectors (FPD). Each strip size is 2200.5 mm3. The dimension of the proton collimators slit is 2mm20mm. The electric conductivity of silicon material, manufactured by Wake Company in Germany, is about 6000 cm. The dark current of each strip is below 1 nA at 100V bias. A quadrupole-dipole (QD) system has been developed to focus and adjust the proton beam. The QD system has a target-to-image demagnification in both transverse directions and therefore produces a spectrum in a small area on the dispersive plane, which can be recorded by the FPD. The beam optics of the spectrometer was calculated using TRANSPORT 5 and Turtle codes. The bending angle of the dipole is 60 and 14MeV protons can be cast in the central trajectory when the magnetic field is 18 kG . 2. EXPERIMENTAL METHOD In order to test the focal plane of the system, a calibration experiment of the FPD using proton beam was carried out at the HI-13 tendon accelerator at China Institute of Atomic Energy (CIAE). The diagram of the spectrometer is shown in Fig.1. The whole system consists of four parts. The first part is the Au scattering chamber, the second part is the vacuum chamber for proton transport, the third part is the magnetic system and the last part is the focal plane detector. An Au foil is set in the center of the scattering chamber and it can deliver appropriate proton beam without losing much of its energy before entering the proton collimator. The Au target is 10mm in diameter and with a mass thickness of 4.7mg/cm2. The energy of incoming proton beam is 14MeV. Then the scattered protons go through a 2.2 cm long collimator to the magnetic analysis system and are focused on the focal plane detector. As shown in Fig.1, a corrugated tube and the back-to-front equipment are installed to adjust the distance from the chamber to the focal plane. Fig.1. The schematic diagram of experimental system The MPR data are collected by the data acquisition (DAQ) system during an experiment run. In addition to collecting data from the detector, the DAQ is also used to monitor the status of detector array, the DAQ electronics and the dipole magnets. The schematic view of the data acquisition is shown in Fig. 2. Fig.2. The schematic view of MPRs data acquisition system Focal Plane Detector 32 Strips Si-PIN Detectors VME DAQ Systam M32 Charge Sensitive Preamplifiers Preamplifier Power Supply CAEN N568B 16 Channel Amplifier CAEN N568B 16 Channel Amplifier CAEN V785N DAQ trig Detectors Bias CF8000 OR CF8000 OR When a proton hits on the silicon strip of the detector array, the output charge signal, related to the energy deposited in the detector, are fed into M32 charge sensitivity preamplifiers. The output signal from preamplifier is then split into two signals and fed into two CAEN 568B linear amplifiers, which constitutes two separate branches of the DAQ system, one analogue and one digital branch. The digital branch, which possesses high throughput, records the counts of signals (time resolved) by using standard CAEN V785N VME system, which is triggered by the signal from the PS CF8000, fed by CAEN 568B fast output signal. In the analogue branch, pulse height histograms are recorded by using analogue-to-digital conversion (ADC) VME modules. The pulse height histograms are used for off-line background corrections of the data. However, only silicon signals above a given absolute voltage (threshold) are recorded so that low-energy events are rejected automatically in the DAQ. When the pulse height histogram at the central channel appears more distinct than that at other channels by adjusting the magnetic current, the current value of the power supply for the magnetic is fixed. After the position of 14MeV proton on the focal plane was obtained, the energy of proton beam was changed step by step from 12MeV to 16MeV by changing the high voltage of the HI-13 tandem accelerator. Then the position spectrum and the pulse height histograms are measured for all silicon strip detectors. An Am-241 alpha standard source and ORTEC 448 pulse generator were used for energy calibration. The yield of proton is monitored by using an ORTEC 439 digital current integrator. The spectrum of protons at each detector position can be deduced from the parameters of VME data acquisition system. 3. RESULTS AND DISCUSSION Fig.3 shows the position distribution of 14MeV protons on focal plane detector. It is clear that only three channels can record the proton beam from the magnetic analysis vacuum chamber. The peak is at the 15th channel. The pulsed height distribution of 15th channel is shown in Fig.4. Fig.3. The position distribution on focal plane detector Fig.4. The pulse height distribution of 15th channel After obtaining the position of 14MeV proton on the focal plane, the energy of proton is changed from 12MeV to 16MeV by changing the high voltage of HI-13 tandem accelerator. The position distributions of different protons on focal plane detector are shown in Fig.5. So the relationship between the energy of protons and the peak of position can be obtained, which is shown in Fig.6. Fig. 5. The position distributions of different protons on focal plane detector Fig. 6. The relationship of energy and the position of silicon strip detector The results show that the position resolution of the system can be up to 50keV/mm or 0.1MeV per channel. The whole range of the focal plane detector can cover about 4MeV, while 40 silicon strips are used together. The uncertainty of the measurement data at 14MeV is around 8%. The energy resolution of 14MeV proton is about 1.4%. It is believed that this compact MPRs ca
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2026年事业单位职业能力倾向测验判断推理试题及答案
- 2026年山西交安b证考试考试试题及答案解析
- 2026年金属冶炼企业车间主任安全责任培训试卷及答案
- 2026年会计职称考试面试题及答案参考
- 2026年工地安全管控冲刺押题(附答案)
- 生态补水工程水资源论证报告书
- 社区核酸采样点群众突发晕厥急救预案
- 2026年5月16日山东省济宁邹城事业单位面试真题及答案解析
- 2026副高卫生职称考试题库
- 农贸市场新建项目交通影响评价
- 黄河流域方言的地域特征与文化变迁-洞察阐释
- 地震基础知识授课课件
- 手机专卖店导购员的日常职责
- 2022年北京市海淀区七年级初一年级下册期末数学试卷(含答案)
- 语文教师书写《识字写字教学》教育教研讲座教学培训课件
- 高速铁路信号系统信号机安装方法
- 儿童绘本故事《蚂蚁搬家》
- 年综合固废收集预处理20万吨新建项目环评资料环境影响
- 劳务合作合同终止协议书
- 民居建筑-福建土楼课件
- 东南亚文化学习通超星期末考试答案章节答案2024年
评论
0/150
提交评论