【BS英国标准】BS EN 61326-2-5-2006 测量、控制和实验室用电气设备.电磁兼容性要求.第2-2部分特殊要求.用于低压分布系统的移动式试验、测量和监测设备用试验配置、操作条件和性能标准.doc_第1页
【BS英国标准】BS EN 61326-2-5-2006 测量、控制和实验室用电气设备.电磁兼容性要求.第2-2部分特殊要求.用于低压分布系统的移动式试验、测量和监测设备用试验配置、操作条件和性能标准.doc_第2页
【BS英国标准】BS EN 61326-2-5-2006 测量、控制和实验室用电气设备.电磁兼容性要求.第2-2部分特殊要求.用于低压分布系统的移动式试验、测量和监测设备用试验配置、操作条件和性能标准.doc_第3页
【BS英国标准】BS EN 61326-2-5-2006 测量、控制和实验室用电气设备.电磁兼容性要求.第2-2部分特殊要求.用于低压分布系统的移动式试验、测量和监测设备用试验配置、操作条件和性能标准.doc_第4页
【BS英国标准】BS EN 61326-2-5-2006 测量、控制和实验室用电气设备.电磁兼容性要求.第2-2部分特殊要求.用于低压分布系统的移动式试验、测量和监测设备用试验配置、操作条件和性能标准.doc_第5页
已阅读5页,还剩10页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

licensed copy: institute of technology tallaght, institute of technology, wed aug 15 19:50:37 gmt+00:00 2007, uncontrolled copy, (c) bsibritish standardbs en61326-2-5:2006electrical equipment for measurement, control and laboratory use emc requirements part 2-5: particular requirements test configurations, operational conditions and performance criteria for field devices with interfaces according to iec 61784-1, cp 3/2the european standard en 61326-2-5:2006 has the status of abritish standardics 25.040.40; 33.100 bs en 61326-2-5:2006national forewordthis british standard was published by bsi. it is the uk implementation of en 61326-2-5:2006. it is identical with iec 61326-2-5:2006. together with bs en 61326-1:2006, bs en 61326-2-1:2006, bs en 61326-2-2:2006,bs en 61326-2-3:2006, bs en 61326-2-4:2006 and bs en 61326-2-6:2006 supersedes bs en 61326:1998 which will be withdrawn no later than1 february 2009.the uk participation in its preparation was entrusted by technical committee gel/65, measurement and control, to subcommittee gel/65/1, system considerations.a list of organizations represented on gel/65/1 can be obtained on request to its secretary.this publication does not purport to include all the necessary provisions of a contract. users are responsible for its correct application.compliance with a british standard cannot confer immunity from legal obligations.licensed copy: institute of technology tallaght, institute of technology, wed aug 15 19:50:37 gmt+00:00 2007, uncontrolled copy, (c) bsiamd. no.datecommentsthis british standard was published under the authority of the standards policy and strategy committeeon 31 january 2007 bsi 2007isbn 978 0 580 50045 9amendments issued since publicationeuropean standarden 61326-2-5norme europenneeuropische norm october 2006 ics 25.040.40; 33.100supersedes en 61326:1997 + a1:1998 + a2:2001 + a3:2003english versionelectrical equipment for measurement, control and laboratory use - emc requirements -part 2-5: particular requirements -test configurations, operational conditions and performance criteria for field devices with interfaces according to iec 61784-1, cp 3/2(iec 61326-2-5:2006)matriel lectrique de mesure,de commande et de laboratoire - exigences relatives la cem - partie 2-5: exigences particulires - configurations dessai, conditionsde fonctionnement et critres daptitude la fonction pour les dispositifsen exploitation avec des interfaces conformes la cei 61784-1, cp 3/2 (cei 61326-2-5:2006)elektrische mess-, steuer-, regel- und laborgerte -emv-anforderungenteil 2-5: besondere anforderungen - prfanordnungen, betriebsbedingungen und leistungsmerkmale fr feldgerte mit schnittstellen gem iec 61784-1, cp 3/2(iec 61326-2-5:2006)licensed copy: institute of technology tallaght, institute of technology, wed aug 15 19:50:37 gmt+00:00 2007, uncontrolled copy, (c) bsithis european standard was approved by cenelec on 2006-09-01. cenelec members are bound to comply with the cen/cenelec internal regulations which stipulate the conditions for giving this european standard the status of a national standard without any alteration.up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the central secretariat or to any cenelec member.this european standard exists in three official versions (english, french, german). a version in any other language made by translation under the responsibility of a cenelec member into its own language and notified to the central secretariat has the same status as the official versions.cenelec members are the national electrotechnical committees of austria, belgium, cyprus, the czech republic, denmark, estonia, finland, france, germany, greece, hungary, iceland, ireland, italy, latvia, lithuania, luxembourg, malta, the netherlands, norway, poland, portugal, romania, slovakia, slovenia, spain, sweden, switzerland and the united kingdom.ceneleceuropean committee for electrotechnical standardization comit europen de normalisation electrotechnique europisches komitee fr elektrotechnische normungcentral secretariat: rue de stassart 35, b - 1050 brussels 2006 cenelec -all rights of exploitation in any form and by any means reserved worldwide for cenelec members.ref. no. en 61326-2-5:2006 een 61326-2-5:2006 9 licensed copy: institute of technology tallaght, institute of technology, wed aug 15 19:50:37 gmt+00:00 2007, uncontrolled copy, (c) bsiforewordthe text of document 65a/474/fdis, future edition 1 of iec 61326-2-5, prepared by sc 65a, system aspects, of iec tc 65, industrial-process measurement and control, was submitted to the iec-cenelec parallel vote and was approved by cenelec as en 61326-2-5 on 2006-09-01.the en 61326 series supersedes en 61326:1997 + corrigendum september 1998 + a1:1998 + a2:2001+ a3:2003.this part of en 61326 is to be used in conjunction with en 61326-1 and follows the same numbering of clauses, subclauses, tables and figures as that standard.the following dates were fixed: latest date by which the en has to be implemented at national level by publication of an identicalnational standard or by endorsement(dop)2007-06-01 latest date by which the national standards conflictingwith the en have to be withdrawn(dow)2009-09-01this european standard has been prepared under a mandate given to cenelec by the european commission and the european free trade association and covers essential requirements of ec directive 89/336/eec. see annex zz.annexes za and zz have been added by cenelec.endorsement noticethe text of the international standard iec 61326-2-5:2006 was approved by cenelec as a europeanstandard without any modification.licensed copy: institute of technology tallaght, institute of technology, wed aug 15 19:50:37 gmt+00:00 2007, uncontrolled copy, (c) bsielectrical equipment for measurement, control and laboratory use emc requirements part 2-5: particular requirements test configurations,operational conditions and performance criteria for field devices with interfaces according to iec 61784-1, cp 3/21scopein addition to the requirements of iec 61326-1, this part of iec 61326 treats the particular features for emc testing of field devices with interfaces according to iec 61784-1, cp 3/2. this part of iec 61326 covers only the field-bus interface of the equipment.note the other functions of the equipment are covered by other parts of the iec 61326 series.this part of iec 61326 refers only to field devices intended for use in process control and process measuring.for interface operation and the interface parameters, this part of iec 61326 is in accordance with iec 61784-1, cp 3/2. that standard specifies a set of protocol specific communication profiles based on the iec 61158 series.the manufacturer specifies the environment for which the product is intended to be used and/or selects the appropriate test level specifications of iec 61326-1.2normative referencesthe following referenced documents are indispensable for the application of this document. for dated references, only the edition cited applies. for undated references, the latest edition of the referenced document (including any amendments) applies.clause 2 of iec 61326-1 applies, except as follows:addition:iec 61326-1:2005, electrical equipment for measurement, control and laboratory use emcrequirements part 1: general requirementsiec 61158 (all parts), digital data communications for measurement and control field-bus for use in industrial control systemsiec 61158-2, digital data communications for measurement and control field-bus for use in industrial control systems part 2 :physical layer specification and service definitioniec 61158-3, digital data communications for measurement and control field-bus for use in industrial control systems part 3 :data link service definitionlicensed copy: institute of technology tallaght, institute of technology, wed aug 15 19:50:37 gmt+00:00 2007, uncontrolled copy, (c) bsiiec 61158-5, digital data communications for measurement and control field-bus for use in industrial control systems part 5 : application layer service definitioniec 61158-6, digital data communications for measurement and control field-bus for use in industrial control systems part 6 : application layer protocol specificationiec 61784 (all parts 1), digital data communications for measurement and controliec 61784-1, digital data communications for measurement and control part 1 : profile sets for continuous and discrete manufacturing relative to fieldbus use in industrial control systems3terms and definitionsclause 3 of iec 61326-1 applies.4generalclause 4 of iec 61326-1 applies.5emc test plan5.1generalsubclause 5.1 of iec 61326-1 applies.5.2configuration of eut during testingsubclause 5.2 of iec 61326-1 is applicable, except as follows:addition:5.2.101test configurationin order to assign any malfunction of the communication during the emc test to the eut, the configuration of field devices with interfaces according to iec 61784-1, cp 3/2, shall be limited to the operation of one master and one slave (eut) during emc type tests.for the slave, auxiliary connections for power supply or signalling are possible.the slave is connected via a three-port field distributor with the signal coupler. the signal coupler is connected to the automation system.a standardized field-bus terminator is attached at the third port of the field distributor.the components eut, signal coupler, field distributor and terminator are connected by means of a standardized field-bus cable.1 other parts are under consideration.licensed copy: institute of technology tallaght, institute of technology, wed aug 15 19:50:37 gmt+00:00 2007, uncontrolled copy, (c) bsithe shield shall be connected at any individual component by a low-impedance grounding strip (connection between the shield and the case with a large surface).the individual cable lengths l1, l2, l3 originate from a practice-adjusted setup, such as the one given in figure 101.the cable length l4 should be in the range of 8 m, in the case where the respective basic standards do not specify other lengths. the cable installation shall be in accordance with the appropriate basic standard.the connection of the shield at the shield grounding point may be produced by partially removing the isolation of the cable shield and fixing the cable shield with a metal clamp or by means of conductive leading-in conductors such as a metallic cable gland at the ground plane or at the shielding metal wall, respectively.the location and execution of the shield grounding point depends on the given test facility; for example, by use of an anechoic chamber or a shielded cabin, it is the metal wall penetration; and with tests on tables with ground plane the shield grounding point is on the ground plane.5.2.102connection linea standard bus cable type a shall be used as the communication line (see 11.8.2 ofiec 61158-2:2003). the cable lengths l1 to l3 are given in figure 101 and l4 is described in.2.103connections at the eutthe grounding of the eut and the shield connections shall be in accordance with the manufacturers specification.5.2.104field-bus network for emc testthe field-bus network includes the terminator of the bus line, a field distributor, a signal coupler, the automation system and the eut.the evaluation and conditioning of the data in the signal coupler and the automation system is not the object of this part of iec 61326.the field distributor and the bus terminator are passive components only.el1 = 8 macl2 = 2 mlicensed copy: institute of technology tallaght, institute of technology, wed aug 15 19:50:37 gmt+00:00 2007, uncontrolled copy, (c) bsif4 l3 = 2 m2l41d5b3iec 1063/06keya automation system (master)1 shield grounding point (sgp)b field device (eut, slave)2 shield connected with low impedancec signal coupler (actual version)3 connection (see 5.2.101)d emc test place4 cable from distributor to sgpe three-port field distributor5 cable from sgp to field devicef terminatorfigure 101 test setup for emc testinglicensed copy: institute of technology tallaght, institute of technology, wed aug 15 19:50:37 gmt+00:00 2007, uncontrolled copy, (c) bsi5.3operation conditions of eut during testingsubclause 5.3 of iec 61326-1 is applicable, except as follows:addition:5.3.101 operational conditionsthe operating conditions describe the software settings at the field device (eut) and at the automation system. the master connected to the signal coupler is set as master class 1, the eut as slave.the cyclic operating mode shall be used.the parameter retry limit shall be set to 2 at the master. this means that, after three consecutive transmission errors (bus-line break down or slave not working), the master (automation system) sets the status to 0.the general bus parameters for the cyclic data exchange in table 84 of iec 61158-3:2003 shall be taken into account.5.3.102statusthe field bus controller, in conjunction with the automation system, monitors the received data of the eut. the received data is of the data type qualifiedfloat32 or qualifiedunsigned8 as defined in 2 or 3 of iec 61158-5. those data types are of the format structure and have a field named status.for the automation system and the test evaluation, the quality in the status is significant.in the case of received data, only four qualities can appear (extract taken from .2.2 ofiec 61158-6):good (cascade)means that the status is in the range between 192 and 255good (non cascade)means that the status is in the range between 128 and 191uncertainmeans that the status is in the range between 64 and 127badmeans that the status is in the range between 0 and 63the eut shall preferably be configured so that the value of the status is 128.other values for the status are allowed if they enable the evaluation of the function of the eut. however, values of the status indicating a disturbed communication shall be avoided. if a status value deviating from 128 is chosen, the reasons for this decision shall be given in the test report.5.3.103monitoringa) the status shall be monitored.b) the measuring value shall be monitored.if the allowed tolerances are not specified in an appropriate part of iec 61326, the values specified by the manufacturer may be used.licensed copy: institute of technology tallaght, institute of technology, wed aug 15 19:50:37 gmt+00:00 2007, uncontrolled copy, (c) bsi5.4specification of performance criteriasubclause 5.4 of iec 61326-1 applies.5.5test descriptionsubclause 5.5 of iec 61326-1 applies.6immunity requirements6.1conditions during the testssubclause 6.1 of iec 61326-1 applies.6.2immunity test requirementssubclause 6.2 of iec 61326-1 applies.6.3random aspectssubclause 6.3 of iec 61326-1 applies.6.4performance criteriasubclause 6.4 of iec 61326-1 applies.in addition, the status shall be monitored.performance criteria a:the status value chosen according to 5.3.102 shall be unchanged during and after the test.performance criteria b:the status value during the test may deviate from that chosen according to 5.3.102. the status value after the test shall remain unchanged from that chosen according to 5.3.102.performance criteria c:the status value during and after test may deviate from that chosen according to emission requirementsclause 7 of iec 61326-1 applies.8test results and test reportclause 8 of iec 61326-1 applies.9instructions for useclause 9 of iec 61326-1 applies.annex za(normative)normative references to international publications with their corresponding european publicationsthe following referenced documents are indispensable for the application of this document. for dated references, only the edition cited applies. for undated references, the latest edition of the referenced document (including any amendments) applies.notewhere an international publication has been modified by common modifications, indicated by (mod), the relevant en/hdapplies.publicationyeartitleen/hdyearaddition to annex za of en 61326-1:2006:iec 61326-12005electrical equipment for measurement, control and laboratory use - emc requirementspart 1: general requirementsen 61326-12006iec 61158series digital data communication for measurement and control - fieldbus for use in industrial control systemsen 61158seriesiec 61158-2- 1)digital data communications for measurement en 61158-22004 2)and control - fieldbus for use in industrialcontrol systemspart 2: physical layer specificatio

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论