FLT_FLOW_TOO_LOW Laser Coolant Flow Is Below The Fault Level(激光器冷却水水流量低)FLT_FLOW_ON_TIMEOUT Laser Coolant Has Not Started Within The Allowed Time(激光器冷却水未在规定时间内打开)FLT_TEMP_COOLANT_IN Coolant Temperature Has Exceeded The Fault Level(冷却水温度超出设定范围)FLT_TEMP_SHUTTER_MIR_1 Shutter Mirror Temperature In Shutter 1 Has Exceeded The Fault Level(光闸反射镜1温度超出设定范围)FLT_TEMP_BEAM_DUMP_1 Shutter Beam Dump Temperature In Shutter 1 Has Exceeded The Fault Level(光闸吸收体温度超出设定范围)FLT_TEMP_TRB_1_CASE Turbine 1 Housing Temperature Has Exceeded The Fault Level(涡轮机1壳体温度超出设定范围)FLT_TEMP_TRB_1_BRNG_A Turbine 1 Bearing A Temperature Has Exceeded The Fault Level(涡轮机1轴承A温度超出设定范围)FLT_TEMP_TRB_1_BRNG_B Turbine 1 Bearing B Temperature Has Exceeded The Fault Level(涡轮机1轴承B温度超出设定范围)FLT_TEMP_TRB_2_CASE Turbine 2 Housing Temperature Has Exceeded The Fault Level(涡轮风机2壳体温度超出设定范围)FLT_TMEP_TRB_2_BRNG_A Turbine 2 Bearing A Temperature Has Exceeded The Fault Level(涡轮机2轴承A温度超出设定范围)FLT_TEMP_TRB_2_BRNG_B Turbine 2 Bearing B Temperature Has Exceeded The Fault Level(涡轮机2轴承B温度超出设定范围)FLT_TEMP_TRB_3_CASE Turbine 3 Housing Temperature Has Exceeded The Fault Level(涡轮风机3壳体温度超出设定范围)FLT_TEMP_TRB_3_BRNG_A Turbine 3 Bearing A Temperature Has Exceeded The Fault Level(涡轮机3轴承A温度超出设定范围)FLT_TEMP_TRB_3_BRNG_B Turbine 3 Bearing B Temperature Has Exceeded The Fault Level(涡轮机3轴承B温度超出设定范围)FLT_TEMP_RESONATOR_GAS Resonator Gas Temperature Has Exceeded The Fault Level(谐振腔气体温度超出设定范围)FLT_TEMP_MODULATOR_OIL Modulator Oil Temperature Has Exceeded The Fault Level (Only on Lasers with tube type HV Power Supplies) (油箱温度超出设定范围)FLT_REGULTNG_PRES_HI Laser Cavity Regulating Pressure Is Above The Fault Level(腔压高)FLT_REGULTNG_PRES_LO Laser Cavity Regulating Pressure Is Below The Fault Level(腔压低)FLT_BACKFILL_TIME_OUT Laser Backfill Has Failed To Complete In The Allowed Time(回充超时)FLT_HE_LO Helium Inlet Pressure Is Below The Fault Level AND Gas Fault Pre-Warning Time Has Expired(氦气压力低)FLT_CO2_LO CO2 Inlet Pressure Is Below The Fault Level AND Gas Fault Pre-Warning Time Has Expired(二氧化碳压力低)FLT_N2_LO Nitrogen Inlet Pressure is Below The Fault Level AND Gas Fault Pre-Warning Time Has Expired(氮气压力低)FLT_AIR_LO Air Inlet Pressure is Below The Fault Level. (空气压力低)FLT_DIS_OVER_CURRENT Current In Resonator Discharge Tube Has Exceeded Fault Level(放电电流过流)FLT_INV_UP2SPEED_TMOUT Inverter Has Failed to Reach Operating Frequency In Allowed Time(变频器在容许的时间内没有达到工作频率)FLT_INV_NOT_UP2SPEED Inverter Operating Frequency Is Below Required Minimum(变频器工作频率低于所需的最低)FLT_INV_FAULTED Inverter Is In Faulted Condition(变频器故障)FLT_VACUUM_PUMP_OVERLD Vacuum Pump Overload Breaker Has Tripped(真空泵断路器过载)FLT_COMPRESSOR _CB_AUX Compressor Circuit Breaker Auxillary Contact Has Tripped(涡轮风机断路器跳闸)FLT_VACUUM_PUMP _CB_AUX Vacuum Pump Circuit Breaker Auxillary Contact Has Tripped(真空泵断路器跳闸)FLT_HV _CB_AUX High Voltage Power Supply Circuit Breaker Auxillary Contact Has Tripped(高压断路器跳闸)FLT_HVPS_CONT_ON_TMOUT High Voltage Power Supply Control Contactor Has Failed to Energize/De-Energize In Allowed Time(在允许的时间内高压电源接触器没有吸合)FLT_ENCL_INTER_LOCK Laser Enclosure Interlock Is In Open State(激光器外壳联锁处于打开状态)FLT_HV_INTER_LOCK HV Safety Interlock is In Open State(激光器高压安全连锁报警)FLT_SHUTTER_1_SW_FAILED Position Switch In Shutter 1 Has Failed(光闸位置开关1出错)FLT_SHUTTER_1_LOST_POS Shutter 1 is in Neither Open Nor Closed Positions(光闸位置开关1既不开也不关反正有问题了)FLT_SHUTTER_1_NOT_OPEN Shutter 1 Failed To Open(光闸1打开失败)FLT_SHUTTER_1_NOT_CLOSE Shutter 1 Failed To Close(光闸1关闭失败)FLT_SHUTTER_2_SW_FAILED Position Switch In Shutter 2 Has Failed(Dual Beam Lasers Only) (光闸位置开关2出错)FLT_SHUTTER_2_LOST_POS Shutter 2 is in Neither Open Nor Closed Positions(Dual Beam Lasers Only) (光闸位置开关2既不开也不关反正有问题了)FLT_SHUTTER_2_NOT_OPEN Shutter 2 Failed To Open(Dual Beam Lasers Only) (光闸开关2打开失败)FLT_SHUTTER_2_NOT_CLOSE Shutter 2 Failed To Close(Dual Beam Lasers Only) (光闸开关2关闭失败)FLT_FS24V_TIMEOUT Fail Safe 24V Relay Did Not Close in Allowed Time(安全24V超时)FLT_PUMP_DOWN_TIMEOUT Laser Pump Down Did Not Complete in Allowed Time(回抽超时)FLT_HVPS_FAULTED A High Voltage Power Supply is in Faulted State(高压电源错误)FLT_HVPS_TUBE_OUT One of the Laser Discharge Tubes has Failed to Reach Minimum Discharge Current Level. (一个放电管没有达到最小放电电流)FLT_SNR_SHUTTER MIR_1 Temperature Sensor on Shutter 1 Mirror Has Failed. (光闸反射镜1温度报警)FLT_SNR_BEAM_DUMP_1 Temperature Sensor on Shutter 1 Beam Dump Has Failed. (光束套管1温度报警)FLT_SNR_SHUTTER MIR_2 Temperature Sensor on Shutter 2 Mirror Has Failed. (Dual Beam Lasers Only) (光闸反射镜2温度报警)FLT_SNR_BEAM_DUMP_2 Temperature Sensor on Shutter 2 Beam Dump Has Failed. (Dual Beam Lasers Only) (光束套管1温度报警)FLT_RESERVED_53 Reserved for Future Use(为将来使用保留)FLT_RESERVED_54 Reserved for Future Use(为将来使用保留)FLT_RESERVED_55 Reserved for Future Use(为将来使用保留)FLT_RESERVED_56 Reserved for Future Use(为将来使用保留)FLT_RESERVED_57 Reserved for Future Use(为将来使用保留)FLT_RESERVED_58 Reserved for Future Use(为将来使用保留)FLT_RESERVED_59 Reserved for Future Use(为将来使用保留)FLT_RESERVED_60 Reserved for Future Use(为将来使用保留)FLT_RESERVED_61 Reserved for Future Use(为将来使用保留)FLT_RESERVED_62 Reserved for Future Use(为将来使用保留)FLT_RESERVED_63 Reserved for Future Use(为将来使用保留)WRN_FLOW_TOO_LO Coolant Flow Is Below Warning Level(冷却水流量低报警)WRN_CDRH_FAIL CDRH Indicator Light Has Failed(CDRH指示等出错)WRN_TEMP_H2O_IN Coolant Inlet Temperature has Exceeded Warning Level(冷却水温度报警)WRN_TEMP_SHTR_MIR_1 Shutter 1 Mirror Temperature Has Exceeded Warning Level(光闸反射镜1温度报警)WRN_TMEP_BEAM_DMP_1 Shutter 1 Beam Dump Temperature Has Exceeded Warning Level(Shutter Beam Dump1温度报警)WRN_TEMP_SHTR_MIR_2 Shutter 2 Mirror Temperature Has Exceeded Warning Level (Dual Beam Lasers Only) (反射镜2温度报警)WRN_TMEP_BEAM_DMP_2 Shutter 2 Beam Dump Temperature Has Exceeded Warning Level (Dual Beam Lasers Only) (Shutter Beam Dump2温度报警)WRN_TEMP_TRB_1_CASE Turbine 1 Housing Temperature Has Exceeded Warning Level(涡轮机1机体温度报警)WRN_TEMP_TRB_1_BRNG_A Turbine 1 Bearing A Temperature Has Exceeded Warning Level(涡轮机1轴承A温度报警)WRN_TEMP_TRB_1_BRNG_B Turbine 1 Bearing B Temperature Has Exceeded Warning Level(涡轮机1轴承B温度报警)WRN_TEMP_TRB_2_CASE Turbine 2 Housing Temperature Has Exceeded Warning Level(涡轮机2机体温度报警)WRN_TEMP_TRB_2_BRNG_A Turbine 2 Bearing A Temperature Has Exceeded Warning Level(涡轮机2轴承A温度报警)WRN_TEMP_TRB_2_BRNG_B Turbine 2 Bearing B Temperature Has Exceeded Warning Level(涡轮机2轴承B温度报警)WRN_TEMP_TRB_3_CASE Turbine 3 Housing Temperature Has Exceeded Warning Level(涡轮机3机体温度报警)WRN_TEMP_TRB_3_BRNG_A Turbine 3 Bearing A Temperature Has Exceeded Warning Level(涡轮机3轴承A温度报警)WRN_TEMP_TRB_3_BRNG_B Turbine 3 Bearing B Temperature Has Exceeded Warning Level(涡轮机3轴承B温度报警)WRN_TEMP_RESONATOR_GAS Resonator Gas Temperature Has Exceeded The WarningLevel(谐振腔气体温度报警)WRN_TEMP_MODULATOR_OIL Modulator Oil Temperature Has Exceeded Warning Level (Only on Lasers that are Equipped with Tube Type HVPS) (油箱温度)WRN_SNR_COOLANT_IN CoolantTemperature Sensor Has Failed(冷却水温度传感器温度错误)WRN_SNR_SHUTTER_MIR_1 Shutter1 Mirror Temperature Sensor Has Failed(光闸反射镜1温度传感器错误)WRN_SNR_BEAM_DUMP_1 Shutter 1 Beam Dump Temperature Sensor Has Failed(Shutter Beam Dump1温度传感器错误)WRN_SNR_SHUTTER_MIR_2 Shutter 2 Mirror Temperature Sensor Has Failed(Dual Beam Lasers Only) (光闸反射镜2温度传感器错误)WRN_SNR_BEAM_DUMP_2 Shutter 2 Beam Dump Temperature Sensor Has Failed(Dual Beam Lasers Only) (Shutter Beam Dump2温度传感器错误)WRN_SNR_TRB_1_CASE Turbine 1 Case Temperature Sensor Has Failed(涡轮机1温度传感器错误)WRN_SNR_TRB_1_BRNG_A Turbine 1 Bearing A Temperature Sensor Has Failed(涡轮机1轴承A温度温度传感器错误)WRN_SNR_TRB_1_BRNG_B Turbine 1 Bearing B Temperature Sensor Has Failed(涡轮机1轴承B温度传感器错误)WRN_SNR_TRB_2_CASE Turbine 2 Case Temperature Sensor Has Failed(涡轮机2温度传感器错误)WRN_SNR_TRB_2_BRNG_A Turbine 2 Bearing A Temperature Sensor Has Failed(涡轮机2轴承A温度温度传感器错误)WRN_SNR_TRB_2_BRNG_B Turbine 2 Bearing B Temperature Sensor Has Failed(涡轮机2轴承B温度传感器错误)WRN_SNR_TRB_3_CASE Turbine 3 Case Temperature Sensor Has Failed(涡轮风机3温度传感器错误)WRN_SNR_TRB_3_BRNG_A Turbine 3 Bearing A Temperature Sensor Has Failed(涡轮机3轴承A温度温度传感器错误)WRN_SNR_TRB_3_BRNG_B Turbine 3 Bearing B Temperature Sensor Has Failed(涡轮机3轴承B温度传感器错误)WRN_SNR_MOD_OIL Modulator Oil Temperature Sensor Has Failed(Only on Lasers that are Equipped with Tube Type HVPS) (油箱温度传感器错误)WRN_HE_LO Helium/Premix Inlet Pressure is Below Fault Level(氦气压力报警)WRN_CO2_LO CO2 Inlet Pressure is Below Fault Level(二氧化碳压力报警)WRN_N2_LO Nitrogen Inlet Pressure is Below Fault Level(氮气压力报警)WRN_AIR_LO Air Purge Inlet Pressure is Below Fault Level(空气压力报警)WRN_INV_FAULT Frequency Inverter is in Fault State During PUMPDOWN Sequence. (回抽时变频器错误)WRN_HVPS_FAULT High Voltage power supply is in a faulted condition. (高压电源错误)WRN_SHUTTER _1_FAULT High Voltage Has Been Initiated With Shutter 1 In Fault State(高压启动后光闸1错误)WRN_SHUTTER _2_FAULT High Voltage Has Been Initiated With Shutter 2 In Fault State(高

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论