8D报告案例模板example.doc_第1页
8D报告案例模板example.doc_第2页
8D报告案例模板example.doc_第3页
8D报告案例模板example.doc_第4页
8D报告案例模板example.doc_第5页
已阅读5页,还剩2页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

CUSTOMER COMPLAINT - FINAL REPORT8D Report number: F040358000FQS -8DGLOBAL INFORMATION8D Close Date:February 04, 2004CUSTOMER NAME:ARRAY ELECTRONICS LTD.Customer contact:Tony ChenCustomer ref.:Customer part number:Area ref. number:NA401012ST creator:Mr Gary HUA, Field Quality Service Asia PacificST manager:(8D report creator)Mr. Bt LEE, Muar plant Quality & Reliability St ref.:F040358000FQS ST commercial product:TDA2007AST Distribution list:Mr Blancky HO, Field Quality Service Asia PacificMrs Cathy LI, Field Quality Service Asia PacificEDDY GAN, PDIP TESTMr Gary HUA, Field Quality Service Asia PacificSP LOW, QA / FAMr Austin WU, Field Quality Service Asia PacificReport approved by:Title:Date:Signature:BT LEECHIEF FA ENGINEER04 Feb 04Report prepared by: SP LOWFA ENGINEER04 Feb 04Detail informationComplaint informationCustomer date:January 19, 2004ST creation date:January 19, 2004ST evidence received date (by FAR Mgr.):January 26, 2004Quantity received by ST:12Quantity affected at Customer:Customer failure rate (ppm):Origin of the defect:ManufacturingCustomer symptom description:The end cusomer believes this part has potential risk.Customer contact:Tony ChenST complaint creatorMr Gary HUA, Field Quality Service Asia PacificST complaint manager:(8d report creator)Mr. Bt LEE, Muar plant Quality & Reliability Device informationCustomer part # :ST commercial product :TDA2007AST raw line #:BA7A*L443CAX Product family (code & description):70 AUDIO SYSTEMSPackage:7A SIL 9Wafer fab. process:OF MT/-HWafer fab.:0857 AMKF AMK 5; CFMAssembly fab.:0959 MU1A ST MUAR - MALAYSIATest plant:0959 MU1T ST MUAR - MALAYSIA8D RESULTS SYNOPSIS / PROBLEM DESCRIPTIONDominant defect description:1: EOS, ESD2: EOS - ESD3: EOS - ESD generalSample RefQty QA numberTracecode19W99CE034123W99CD0341Root Cause:Application / Electrical overstressContainment action:Implementation date:None.February 04, 2004Corrective action:Implementation date:Not ApplicableFebruary 04, 20048D REPORT DETAILS: F040358000FQS -8DST Analysis results synopsisDominant defect description:1: EOS, ESD2: EOS - ESD3: EOS - ESD generalSample RefQty QA numberTracecode19W99CE034123W99CD03411D Team8D team leader :Mr. Bt LEE, Muar plant Quality & Reliability Team members :EDDY GAN, PDIP TESTSP LOW, QA / FA2D Problem descriptionCustomer symptomSample:1Cust. symptom description: the end cusomer believes this part has potential risk.Sample:2Cust. symptom description: the end cusomer believes this part has potential risk.Symptom comments11 units were tested failed catastropy. Burnt marks due to electrical overstress were observed. 1 unit was tested good in ATE.Muar FA Findings:StepsFindingsExternal visual inspectionOnly 3 units with tracecodeW99CE0341 have unbroken leads, the other 9 units were having broken leads.Curve tracingLeakage or short at Pin 8 or Pin 9 vs ground except for unit with reference #1.X-raysNo anomalies.ATEOnly unit with reference #1 was tested good in ATE, the other 11 units were tested fail Bin #6, #27 and #28.Decapsulation-Internal visual inspectionBurnt marks were observed on die top between Pin 8 and Pin 9 rails for units with reference #4, #5, #10 and #11. Note: Units with reference #1 to #9 are from tracecode W99CE0341; units with reference #10 to #12 are from tracecode W99CD0341.Enclosure:Pin 9 of Unit Reference #10Pin 8 of Unit Reference #11Pin 9 of Unit Reference #11Pin 8 of Unit Reference #4Pin 9 of Unit Reference #4Pin 8 of Unit Reference #5Pin 9 of Unit Reference #53D Containment actionNot Applicable.4D CauseArea involvedMacro process:CUSTOMERLocation:CUSTOMERProcess step:APPLICATION (EOS)Root causeRoot cause:Application / Electrical overstressDefect intentionally reproduced:Escape root cause description:Not Applicable.Problem root cause description:Not Applicable.5D Corrective action & VerificationNot Applicable.6D Implementation of permanent corrective actionNot Applicable.7D PreventionRevised Quality System Doc.Reference & version changesDate of create-updateError of process: NOControl plan Ref.:Not applicableError of application: YESFailure Modes Effects Analysis Ref.:Not applicableSpecification Ref.:Not applicableCross-fertilization Ref.:Not applicableText - Comments :Not required since the unit was failed during the customers application.8D Information & ConclusionStatus:CompletedClose date:February 04, 2004Estimated date of parts delivery after containmentAdditional comments:None.Electrical Analysis ANALYSIS DATA AND RESULTS : Sample ref.:F040358000FQS -EA1 - 2Units ser. no:All unitsFail type:StableCorrelation with customer:noElectrical defect:1- TESTING2- DC tests3- Short.Remark:All units were tested failed catastropy in ATE.Sample ref.:F040358000FQS -EA1 - 1Units ser. no:All unitsFail type:StableCorrelation with customer:noElectrical defect:1- TESTING2- DC tests3- Short.Remark:Unit with reference #1 was teste

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论