Cisco9124 SAN交换机简单配置.doc_第1页
Cisco9124 SAN交换机简单配置.doc_第2页
Cisco9124 SAN交换机简单配置.doc_第3页
Cisco9124 SAN交换机简单配置.doc_第4页
Cisco9124 SAN交换机简单配置.doc_第5页
已阅读5页,还剩10页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

MDSMDS 91249124 配置配置 Delete a zone that you created 2 Clear a startup configuration enter the write erase command from the EXEC mode prompt 2 Setting the Switch s Shell Timeout 2 Installing and Clearing a License 3 Displays a Specified License 3 Displays All Licenses 3 Displays the Host ID 4 Assigning a Switch Name 4 Configuring the Management Port 4 Disablingor enable a Telnet or ssh Server 5 Download a configuration file from a remote server 5 Saving the Configuration 5 Creating and Configuring VSANs 6 Assigning VSAN Membership 6 Deleting VSANs 7 Viewing VSAN Configurations 7 Configuring Fibre Channel Interfaces 8 Configuring a Zone 9 Zone Sets 9 Active Zone Set 9 Viewing Zone Information 10 Recovering Administrator Password 12 FOR EXAMPLE 13 Delete a zone that you created switch config zonezone namename testtest vsanvsan 1 1 switch config zone exitexit switch config nono zonezone namename testtest vsanvsan 1 1 switch config Clear a configure 清除配置参数清除配置参数 Switch write erase Setting the Switch s Shell Timeout switch config line console switch config console exec timeout 60 switch config line vty switch config line exec timeout 60 Installing and Clearing a License switch install license bootflash license file switch clear license license file switch clear license all Displays a Specified License switch show license fcports lic fcports lic SERVER this host ANY VENDOR cisco FEATURE fcports cisco 1 000 permanent 30 HOSTID VDH 4C0AF664 SIGN 24B2B68AA676 fcport license Displays All Licenses switch show license all fcports lic SERVER this host ANY VENDOR cisco FEATURE fcports cisco 1 000 permanent 30 HOSTID VDH 4C0AF664 SIGN 24B2B68AA676 fcport license ficon lic FEATURE ficon cisco 1 000 permanent uncounted HOSTID VDH 4C0AF664 SIGN CB7872B23700 ficon license Displays the Host ID switch show license hostid License hostid VDH 4C0AF664 Assigning a Switch Name switch config t switch config switchname myswitch1 myswitch1 config myswitch1 config no switchname switch config Configuring the Management Port switch config terminal switch config interface mgmt 0 switch config ip address 1 1 1 0 255 255 255 0 switch config if no shutdown switch config if exit switch config ip default gateway 1 1 1 1 Disablingor enable a Telnet or ssh Server switch config t switch config no telnet server enable switch config telnet server enable switch config t Step 2 switch config ssh server enable switch config no ssh server enable Download a configuration file from a remote server switch copy system running config switch copy tftp 172 16 10 1 237 img bootflash 237 img Saving the Configuration switch copy running config startup config Creating and Configuring VSANs switch config t switch config vsan database switch config vsan db switch config vsan db vsan 2 switch config vsan db switch config vsan db vsan 2 name TechDoc Assigning VSAN Membership switch config t switch config vsan database switch config vsan db switch config vsan db vsan 2 switch config vsan db switch config vsan db vsan 2 interface fc1 8 switch config vsan db switch config vsan db vsan 7 switch config vsan db switch config vsan db vsan 7 interface fc1 8 Deleting VSANs switch config t switch config vsan database switch config db switch config db vsan 2 switch config vsan db switch config vsan db no vsan 5 switch config vsan db switch config vsan db end switch Viewing VSAN Configurations switch switch showshow vsanvsan 100100 vsan 100 information name VSAN0100 state active in order guarantee no interoperability mode no loadbalancing src id dst id oxid switch switch showshow vsanvsan usageusage 4 vsan configured configured vsans 1 4 vsans available for configuration 5 4093 switch switch showshow vsanvsan vsan 1 information name VSAN0001 state active in order guarantee no interoperability mode no loadbalancing src id dst id oxid vsan 2 information name VSAN0002 state active in order guarantee no interoperability mode no loadbalancing src id dst id oxid vsan 7 information name VSAN0007 state active in order guarantee no interoperability mode no loadbalancing src id dst id oxid vsan 100 information name VSAN0100 state active in order guarantee no interoperability mode no loadbalancing src id dst id oxid switchswitch showshow vsanvsan 1 1 membershipmembership vsan 1 interfaces fc2 16 fc2 15 fc2 14 fc2 13 fc2 12 fc2 11 fc2 10 fc2 9 fc2 8 fc2 7 fc2 6 fc2 5 fc2 4 fc2 3 fc2 2 fc2 1 fc1 16 fc1 15 fc1 14 fc1 13 fc1 12 fc1 11 fc1 10 fc1 9 fc1 7 fc1 6 fc1 5 fc1 4 fc1 3 fc1 2 fc1 1 vsan 2 interfaces vsan 7 interfaces fc1 8 vsan 100 interfaces vsan 4094 isolated vsan interfaces Configuring Fibre Channel Interfaces switch config t switch config interface fc1 1 switch config t switch config interface fc1 1 4 fc2 1 3 switch config if no shutdown switch config if shutdown Configuring a Zone switch config t switch config zone name Zone1 vsan 3 switch config zone switch config zone member interface fc 2 1 Zone Sets Either zone set A or zone set B can be activated but not together switch config t switch config zoneset name Zoneset1 vsan 3 switch config zoneset switch config zoneset member Zone1 switch config zoneset Active Zone Set switch config t switch config switch config zoneset activate name Zoneset1 vsan 3 switch config no zoneset activate name Zoneset1 vsan 3 ATTETION If one zone set is active and you activate another zone set the currently active zone set is automatically deactivated You don t need to explicitly deactivate the currently active zone set before activating a new zone set Viewing Zone Information Displays Zone Information for All VSANs switch show zone zone name Zone3 vsan 1 pwwn 21 00 00 20 37 6f db dd pwwn 21 00 00 20 37 9c 48 e5 zone name Zone2 vsan 2 fwwn 20 41 00 05 30 00 2a 1e fwwn 20 42 00 05 30 00 2a 1e fwwn 20 43 00 05 30 00 2a 1e zone name Zone1 vsan 1 pwwn 21 00 00 20 37 6f db dd pwwn 21 00 00 20 37 a6 be 2f pwwn 21 00 00 20 37 9c 48 e5 Displays Zone Information for a Specific VSAN switch show zone vsan 1 zone name Zone3 vsan 1 pwwn 21 00 00 20 37 6f db dd pwwn 21 00 00 20 37 9c 48 e5 zone name Zone2 vsan 1 fwwn 20 4f 00 05 30 00 2a 1e fwwn 20 50 00 05 30 00 2a 1e fwwn 20 51 00 05 30 00 2a 1e fwwn 20 52 00 05 30 00 2a 1e fwwn 20 53 00 05 30 00 2a 1e zone name Zone1 vsan 1 pwwn 21 00 00 20 37 6f db dd pwwn 21 00 00 20 37 a6 be 2f pwwn 21 00 00 20 37 9c 48 e5 Display Configured Zone Set Information switch show zoneset vsan 1 zoneset name ZoneSet2 vsan 1 zone name Zone2 vsan 1 fwwn 20 4e 00 05 30 00 2a 1e fwwn 20 4f 00 05 30 00 2a 1e fwwn 20 50 00 05 30 00 2a 1e fwwn 20 51 00 05 30 00 2a 1e fwwn 20 52 00 05 30 00 2a 1e zone name Zone1 vsan 1 pwwn 21 00 00 20 37 6f db dd pwwn 21 00 00 20 37 a6 be 2f pwwn 21 00 00 20 37 9c 48 e5 fcalias Alias1 zoneset name ZoneSet1 vsan 1 zone name Zone1 vsan 1 pwwn 21 00 00 20 37 6f db dd pwwn 21 00 00 20 37 a6 be 2f pwwn 21 00 00 20 37 9c 48 e5 fcalias Alias1 Display Configured Zone Set Information for a Range of VSANs switch show zoneset vsan 2 3 zoneset name ZoneSet2 vsan 2 zone name Zone2 vsan 2 fwwn 20 52 00 05 30 00 2a 1e fwwn 20 53 00 05 30 00 2a 1e fwwn 20 54 00 05 30 00 2a 1e fwwn 20 55 00 05 30 00 2a 1e fwwn 20 56 00 05 30 00 2a 1e zone name Zone1 vsan 2 pwwn 21 00 00 20 37 6f db dd pwwn 21 00 00 20 37 a6 be 2f pwwn 21 00 00 20 37 9c 48 e5 fcalias Alias1 zoneset name ZoneSet3 vsan 3 zone name Zone1 vsan 1 pwwn 21 00 00 20 37 6f db dd pwwn 21 00 00 20 37 a6 be 2f pwwn 21 00 00 20 37 9c 48 e5 fcalias Alias1 Displays Active Zonesets switch show zoneset active zoneset name ZoneSet1 vsan 1 zone name zone1 vsan 1 fcid 0 x080808 fcid 0 x090909 fcid 0 x0a0a0a zone name zone2 vsan 1 fcid 0 xef0000 pwwn 21 00 00 20 37 6f db dd fcid 0 xef0100 pwwn 21 00 00 20 37 a6 be 2f Displays Brief Descriptions of Zone Sets switch show zoneset brief zoneset name ZoneSet1 vsan 1 zone zone1 zone zone2 Recovering Administrator Password Step 1 Reboot the switch switch reload The supervisor is going down for reboot NOW Step 2 Press the Ctrl key sequence when the switch begins its SAN OS software boot sequence to enter the switch boot prompt switch boot Step 3 Change to configuration mode switch boot config terminal Step 4 Enter the admin password command to reset the administrator password switch boot config admin password password Step 5 Exit to the EXEC mode switch boot config exit switchboot Step 6 Enter the load command to load the SAN OS software switch boot load bootflash system img mz Step 7 Save the software configuration switch copy running config startup config FOR EXAMPLE switch1 config t Enter configuration commands one per line End with CNTL Z switch1 config interface fc1 1 8 switch1 config if no shutdown switch1 config if exit switch1 config vsan database switch1 config vsan db vsan 2 name jsfgc switch1 config vsan db vsan 2 i

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论