HP服务器的一些启动报错的原因和解决办法(中英双语).doc_第1页
HP服务器的一些启动报错的原因和解决办法(中英双语).doc_第2页
HP服务器的一些启动报错的原因和解决办法(中英双语).doc_第3页
HP服务器的一些启动报错的原因和解决办法(中英双语).doc_第4页
HP服务器的一些启动报错的原因和解决办法(中英双语).doc_第5页
已阅读5页,还剩8页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

304-Keyboard or System Unit Erroraudible beeps: none possible cause: keyboard, keyboard cable, mouse controller, or system board failure. action: 1. be sure the keyboard and mouse are connected. only authorized technicians trained by hp should attempt to remove the system board. if you believe the system board requires replacement, contact hp technical support before proceeding. 2. run insight diagnostics (hp insight diagnostics on page 101) and replace failed components as indicated. 400 series list of messages: 40x-parallel port x address assignment conflict 404-parallel port address conflict detected 40x-parallel port x address assignment conflict audible beeps: 2 short possible cause: both external and internal ports are assigned to parallel port x. action: run the server setup utility and correct the configuration. 404-parallel port address conflict detected. .a hardware conflict in your system is keeping some system components from working correctly. if you have recently added new hardware remove it to see if it is the cause of the conflict. alternatively, use computer setup or your operating system to insure that no conflicts exist. audible beeps: 2 short possible cause: a hardware conflict in the system is preventing the parallel port from working correctly. action: 1. if you have recently added new hardware, remove it to see if the hardware is the cause of the conflict. 2.run the server setup utility to reassign resources for the parallel port and manually resolve the resource conflict. 3. run insight diagnostics (hp insight diagnostics on page 101) and replace failed components as indicated. 600 series list of messages: 601-diskette controller error 602-diskette boot record error 605-diskette drive type error 611-primary floppy port address assignment conflict 612-secondary floppy port address assignment conflict 601-diskette controller error audible beeps: none possible cause: diskette controller circuitry failure occurred. action: 1. be sure the diskette drive cables are connected. 2. replace the diskette drive, the cable, or both. 3. run insight diagnostics (hp insight diagnostics on page 101) and replace failed components as indicated. 602-diskette boot record error audible beeps: none possible cause: the boot sector on the boot disk is corrupt. action: 1. remove the diskette from the diskette drive. 2. replace the diskette in the drive. 3. reformat the diskette. 605-diskette drive type error. audible beeps: 2 short possible cause: mismatch in drive type occurred. action: run the server setup utility to set the diskette drive type correctly. 611-primary floppy port address assignment conflict audible beeps: 2 short possible cause: a hardware conflict in the system is preventing the diskette drive from operating properly. action: 1. run the server setup utility to configure the diskette drive port address and manually resolve the conflict. 2. run insight diagnostics (hp insight diagnostics on page 101) and replace failed components as indicated. 612-secondary floppy port address assignment conflict audible beeps: 2 short possible cause: a hardware conflict in the system is preventing the diskette drive from operating properly. action: 1. run the server setup utility to configure the diskette drive port address and manually resolve the conflict. 2. run insight diagnostics (hp insight diagnostics on page 101) and replace failed components as indicated. 1100 series list of messages: 1151-com port 1 address assignment conflict 1151-com port 1 address assignment conflict audible beeps: 2 short possible cause: both external and internal serial ports are assigned to com x. action: run the server setup utility and correct the configuration. 1600 series list of messages: 1609 - the server may have a failed system battery. some 1610-temperature violation detected. - waiting 5 minutes for system to cool 1611-cpu zone fan assembly failure detected. either 1611-cpu zone fan assembly failure detected. single fan 1611-fan failure detected 1611-fan x failure detected (fan zone cpu) 1611-fan x failure detected (fan zone i/o) 1611-fan x not present (fan zonecpu) 1611-fan x not present (fan zone i/o) 1611- power supply zone fan assembly failure detected. either 1611-power supply zone fan assembly failure detected. single fan 1611-primary fan failure (fan zone system) 1611-redundant fan failure (fan zone system) 1612-primary power supply failure 1615-power supply configuration error 1615-power supply configuration error 1615-power supply failure, power supply unplugged, or power supply fan failure in bay x 1616-power supply configuration failure 1609 - the server may have a failed system battery. some. .configuration settings may have been lost and restored to defaults. refer to server documentation for more information. if you have just replaced the system battery, disregard this message. audible beeps: none possible cause: real-time clock system battery has lost power. the system will lose its configuration every time ac power is removed (when the system is unplugged from ac power source) and this message displays again if a battery failure has occurred. however, the system will function and retain configuration settings if the system is connected to the ac power source. action: replace battery (or add external battery). 1610-temperature violation detected. - waiting 5 minutes for system to cool audible beeps: none possible cause: the ambient system temperature exceeded acceptable levels. action: lower the room temperature. 1611-cpu zone fan assembly failure detected. either. .the assembly is not installed or multiple fans have failed in the cpu zone. audible beeps: none possible cause: required fans are missing or not spinning. action: 1. check the fans to be sure they are installed and working. 2. be sure the assembly is properly connected and each fan is properly seated. 3. if the problem persists, replace the failed fans. 4. if a known working replacement fan is not spinning, replace the assembly. 1611-cpu zone fan assembly failure detected. single fan. .failure. assembly will provide adequate cooling. audible beeps: none possible cause: required fan not spinning. action: replace the failed fan to provide redundancy, if applicable. 1611-fan failure detected audible beeps: 2 short possible cause: required fan not installed or spinning. action: 1. check the fans to be sure they are working. 2. be sure each fan cable is properly connected and each fan is properly seated. 3. if the problem persists, replace the failed fans. 1611-fan x failure detected (fan zone cpu) audible beeps: 2 short possible cause: required fan not installed or spinning. action: 1. check the fans to be sure they are working. 2. be sure each fan cable is properly connected, if applicable, and each fan is properly seated. 3. if the problem persists, replace the failed fans. 1611-fan x failure detected (fan zone i/o) audible beeps: 2 short possible cause: required fan not installed or spinning. action: 1. check the fans to be sure they are working. 2. be sure each fan cable is properly connected, if applicable, and each fan is properly seated. 3. if the problem persists, replace the failed fans. 1611-fan x not present (fan zonecpu) audible beeps: 2 short possible cause: required fan not installed or spinning. action: 1. check the fans to be sure they are working. 2. be sure each fan cable is properly connected, if applicable, and each fan is properly seated. 3. if the problem persists, replace the failed fans. 1611-fan x not present (fan zone i/o) audible beeps: 2 short possible cause: required fan not installed or spinning. action: 1. check the fans to be sure they are working. 2. be sure each fan cable is properly connected, if applicable, and each fan is properly seated. 3. if the problem persists, replace the failed fans. 1611- power supply zone fan assembly failure detected. either. .the assembly is not installed or multiple fans have failed. audible beeps: none possible cause: required fans are missing or not spinning. action: 1. check the fans to be sure they are installed and working. 2. be sure the assembly is properly connected and each fan is properly seated. 3. if the problem persists, replace the failed fans. 4. if a known working replacement fan is not spinning, replace the assembly. 1611-power supply zone fan assembly failure detected. single fan. .failure. assembly will provide adequate cooling. audible beeps: none possible cause: required fan not spinning. action: replace the failed fan to provide redundancy, if applicable. 1611-primary fan failure (fan zone system) audible beeps: none possible cause: a required fan is not spinning. action: replace the failed fan. 1611-redundant fan failure (fan zone system) audible beeps: none possible cause: a redundant fan is not spinning. action: replace the failed fan. 1612-primary power supply failure audible beeps: 2 short possible cause: primary power supply has failed. action: replace power supply. 1615-power supply configuration error audible beeps: none possible cause: the server configuration requires an additional power supply. a moving bar is displayed, indicating that the system is waiting for another power supply to be installed. action: install the additional power supply. 1615-power supply configuration error - a working power supply must be installed in bay 1 for proper cooling. - system halted! audible beeps: none possible cause: the server configuration requires an additional power supply. a moving bar is displayed, indicating that the system is waiting for another power supply to be installed. action: install the additional power supply. 1615-power supply failure, power supply unplugged, or power supply fan failure in bay x audible beeps: none possible cause: the power supply has failed, or it is installed but not connected to the system board or ac power source. action: reseat the power supply firmly and check the power cable or replace power supply. 1616-power supply configuration failure -a working power supply must be installed in bay 1 for proper cooling. -system halted! audible beeps: none possible cause: power supply is improperly configured. action: run the server setup utility and correct the configuration.304键盘或系统组合误差 听见蜂鸣声:无 可能的原因:键盘,键盘线,鼠标控制器或系统板故障。 行动: 1。可以肯定的键盘和鼠标连接。 只有授权的惠普培训的技术人员应努力消除系统板。如果你相信系统板之前需要进行更换,联系惠普技术支持。 2。运行洞察诊断(“惠普洞察分析”页101)和替换故障组件的说明。 400系列 名单的消息: 40倍,并口x地址分配冲突 404并行端口地址冲突检测 40倍,并口x地址分配冲突 听见蜂鸣声:2短 可能的原因:外部和内部端口被分配到并行端口x的 行动:在服务器上运行安装实用工具和正确的配置。 404并行端口地址冲突检测. 硬件冲突.您的系统保持正常运行某些系统组件。如果您最近添加了新硬件删除它,看看它是冲突的原因。或者,使用计算机设置或您的操作系统以确保没有冲突存在。 听见蜂鸣声:2短 可能的原因:在系统硬件冲突阻止正常工作的并行端口。 行动: 1。如果您最近添加了新硬件,删除它,看看硬件是冲突的原因。 2.run服务器安装实用工具来重新分配资源的并行端口和手动解决资源冲突。 3。运行洞察诊断(“惠普洞察分析”页101)和替换故障组件的说明。 600系列 名单的消息: 601 -软盘控制器错误 602 -软盘引导记录错误 605软盘驱动器类型的错误 611小学软盘端口地址分配冲突 612中学软盘端口地址分配冲突 601 -软盘控制器错误 听见蜂鸣声:无 可能的原因:软盘控制器电路出现故障。 行动: 1。可以肯定的软盘驱动器电缆连接。 2。取代软盘驱动器,电缆,或两者兼而有之。 3。运行洞察诊断(“惠普洞察分析”页101)和替换故障组件的说明。 602 -软盘引导记录错误 听见蜂鸣声:无 可能的原因:在启动磁盘启动扇区已损坏。 行动: 1。从软盘驱动器中删除该磁盘。 2。替换驱动器中的软盘。 3。格式化的软盘。 605软盘驱动器类型的错误。 听见蜂鸣声:2短 可能的原因:在驱动器不匹配的类型发生。 行动:在服务器上运行安装实用工具来设置磁盘驱动器的类型正确。 611小学软盘端口地址分配冲突 听见蜂鸣声:2短 可能的原因:在系统硬件冲突是防止从软盘驱动器运行正常。 行动: 1。在服务器上运行安装实用工具来配置软盘驱动器端口地址和手动解决冲突。 2。运行洞察诊断(“惠普洞察分析”页101)和替换故障组件的说明。 612中学软盘端口地址分配冲突 听见蜂鸣声:2短 可能的原因:在系统硬件冲突是防止从软盘驱动器运行正常。 行动: 1。在服务器上运行安装实用工具来配置软盘驱动器端口地址和手动解决冲突。 2。运行洞察诊断(“惠普洞察分析”页101)和替换故障组件的说明。 1100系列 名单的消息: 1151 - 1地址分配COM端口冲突 1151 - 1地址分配COM端口冲突 听见蜂鸣声:2短 可能的原因:外部和内部串行端口被分配到COM十 行动:在服务器上运行安装实用工具和正确的配置。 1600系列 名单的消息: 1609 - 服务器可能有一个失败的系统电池。一些 1610年温违反检测。 - 等待5分钟,冷却系统 1611 CPU的风扇装配故障检测区。或 1611 CPU的风扇装配故障检测区。单扇 1611 -风扇故障检测 1611 -风扇x故障检测(扇区的CPU) 1611 -风扇x故障检测(扇区的I / O) 1611 - x不存在风扇(风扇zonecpu) 1611 - x不存在风扇(风扇带的I / O) 1611 - 电源风扇部件故障检测区。或 1611 -电源风扇部件故障检测区。单扇 1611年小学风扇故障(风扇带系统) 1611冗余风扇故障(风扇带系统) 1612年,主要电力供应中断 1615年,电源配置错误 1615年,电源配置错误 1615年,电源故障,电源拔掉,或在海湾电源风扇故障x 1616年,电源配置失败 1609 - 服务器可能有一个失败的系统电池。一些. .配置设置可能已丢失,恢复到默认值。参考服务器文档了解更多信息。如果你刚刚更换的系统电池,忽略此消息。 听见蜂鸣声:无 可能的原因:实时时钟系统的电池已失去动力。该系统将失去它的配置,每次交流电源被移走(当该系统是从AC电源断开)和此消息如果电池发生故障显示。然而,该系统将配置设置功能和保留如果系统已连接到交流电源。 行动:更换电池(或添加外部电池)。 1610年温违反检测。 - 等待5分钟,冷却系统 听见蜂鸣声:无 可能的原因:环境系统的温度超出可接受的水平。 行动:降低室内温度。 1611 CPU的风扇装配故障检测区。要么. .大会未安装或多个球迷在CPU区失败。 听见蜂鸣声:无 可能的原因:需要球迷已丢失或不旋转。 行动: 1。检查风扇以确保它们安装和工作。 2。可以相信大会已正确连接,每个风扇安装正确。 3。如果问题仍然存在,请更换故障的风扇。 4。如果一个已知的工作更换风扇不转动,取代大会。 1611 CPU的风扇装配故障检测区。单扇. .失败。大会将提供充分的冷却。 听见蜂鸣声:无 可能的原因:需要风扇不转动。 行动:更换故障风扇,以提供冗余,如适用。 1611 -风扇故障检测 听见蜂鸣声:2短 可能的原因:没有安装所需的风扇或旋转。 行动: 1。检查风扇以确保他们的工作。 2。确保每个风扇电缆连接正确,每个

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论