Short communication Experimental performance of R432A to replace R22 in residential air conditioners and heat pumps Ki Jung Park Yun Bo Shim Dongsoo Jung Department of Mechanical Engineering Inha University Incheon 402 751 Republic of Korea a r t i c l ei n f o Article history Received 19 December 2007 Accepted 20 February 2008 Available online 4 March 2008 Keywords Natural refrigerants Propylene Dimethylether R432A Air conditioners Heat pumps a b s t r a c t In this study thermodynamic performance of R432A and HCFC22 is measured in a heat pump bench tes ter under both air conditioning and heat pumping conditions R432A has no ozone depletion potential and very low greenhouse warming potential of less than 5 R432A also offers a similar vapor pressure to HCFC22 for drop in replacement Test results showed that the coeffi cient of performance and capacity of R432A are 8 5 8 7 and 1 9 6 4 higher than those of HCFC22 for both conditions The compressor dis charge temperature of R432A is 14 1 17 3 C lower than that of HCFC22 while the amount of charge for R432A is 50 lower than that of HCFC22 due to its low density Overall R432A is a good long term drop in environmentally friendly alternative to replace HCFC22 in residential air conditioners and heat pumps due to its excellent thermodynamic and environmental properties 2008 Elsevier Ltd All rights reserved 1 Introduction For the past few decades HCFC22 has been predominantly used in residential air conditioners and heat pumps The parties to the Montreal protocol however decided to phase out HCFC22 eventu ally since it contains ozone depleting chlorine 1 Hence the reg ulation for HCFC production has begun from 1996 in the developed countries and for new equipment HCFC22 is not currently used in European Union and it can not be used in United States from 2010 For the past years various alternatives for HCFC22 have been proposed 2 4 and tested 3 4 in an effort to comply with the Montreal protocol At this time HFC refrigerant mixtures such as R410A and R407C are used in some countries to replace HCFC22 2 5 At the same time many companies expend much effort to develop their own alternatives for HCFC22 Especially refrigerant mixtures composed of environmentally safe pure refrigerants have gotten a special attention from the industry with the expectation of possible energy effi ciency without major changes in the system 6 These days greenhouse warming has become one of the most important global issues and Kyoto protocol was proposed to re solve this issue which classifi ed HFCs as greenhouse gases 7 With this global trend in view HFC134a will be banned in mobile air conditioners of new vehicles from 2011 according to EU F Gases Regulation and MAC directive which specifi cally bans the use of refrigerants having global warming potential GWP of more than 150 8 For reference the GWP of HFC134a is 1300 At this time many EU countries seriously consider the ban of the use of even HFCs in residential air conditioners and heat pumps 9 Even though HFC refrigerants of R410A and R407C are used in some sys tems their future is not certain since their GWPs are 1700 2000 which is even higher than that of HFC134a One of the possible solutions to avoid HFCs of high GWP is the use of natural refrigerants such as hydrocarbons For the past few decades fl ammable hydrocarbon refrigerants have been prohibited in normal air conditioning applications due to a safety concern These days however this trend is somewhat relaxed because of the environmental and energy issue Therefore some of the fl am mable refrigerants have been applied to certain applications 10 11 Propane R290 and propylene R1270 are used for heat pumping applications in Europe 12 It is well known that hydro carbons offer low GWPs of less than 5 low cost availability com patibility with the conventional mineral oil and environmental friendliness 10 11 Furthermore dimethylether DME RE170 is a good environmentally friendly refrigerant having excellent ther modynamic properties 13 Recently ASHRAE listed R432A as a possible candidate to re place R22 14 R432A is a near azeotropic mixture composed of 80 propylene R1270 and 20 dimethylether RE170 by mass It has no ozone depletion potential and very low GWP of less than 5 Its gliding temperature difference during phase change is 1 C with normal boiling point of 46 6 C Even though this is a mix ture heat transfer degradation is not expected since its gliding temperature difference is very small 15 In this study thermody namic performance of R432A was measured in an attempt to 1359 4311 see front matter 2008 Elsevier Ltd All rights reserved doi 10 1016 j applthermaleng 2008 02 019 Corresponding author Tel 82 32 860 7320 fax 82 32 868 1716 E mail address dsjung inha ac kr D Jung Applied Thermal Engineering 29 2009 597 600 Contents lists available at ScienceDirect Applied Thermal Engineering journal homepage examine the possibility of drop in substitution of HCFC22 for air conditioning and heat pumping applications 2 Experiments 2 1 Experimental apparatus In this study drop in performance of R432A is measured using the similar experimental apparatus as described in Ref 3 As seen in Fig 1 the apparatus has the water cooled con denser and water heated evaporator with a nominal capacity of 3 5 kW A rotary compressor designed originally for HCFC22 was used to lift the pressure while a hand expansion valve was used for regulating the mass fl ow rate Since Ref 3 con tains all the details of the test apparatus measurements test procedures data verifi cation etc an interested reader is referred to Ref 3 In this paper test procedure and test condition will be described 2 2 Test procedure Test procedure is as follows 1 The system was evacuated for 2 3 h before charging 2 The temperatures in the chiller and heating bath were set and the secondary heat transfer fl uid HTF was pumped into the evaporator and condenser and the system was charged with a specifi c refrigerant For R22 the system was charged with a vapor refrigerant at the compressor inlet For R432A the system was charged with a lower vapor pressure refrig erant RE170 at the compressor inlet which was followed by a higher vapor pressure fl uid R1270 A digital scale of 0 1 g accuracy was employed to measure the amount of charge 3 The expansion valve was controlled and simultaneously the amount of charge was adjusted to maintain the constant superheat and subcooling usually 5 C each at the exits of evaporator and condenser Nomenclature COP coeffi cient of performance GWPglobal warming potential PRpressure ratio Qcapacity W Ttemperature C Wcompressor work W Subscripts ccondenser disdischarge eevaporator T T Expansion Valve Flow meter Ref Filter Drier Sight Glass SLHX T T T Cond Water Evap Water Heat Exchanger Condenser TP T T T T T T T T T T T T T TP T T TP T T T T T T T T T T T T T T TP Water Heater Water Chiller Evaporator Flow meter Cond Water Flow meter Evap Water Compressor Evap Water Cond Water Refrigerant T Temperature P Pressure TP Thermopile SLHX Suction Line Heat Exchanger TPTP 3 Way Valve Fig 1 Schematic of a heat pump bench tester Ref 3 598K J Park et al Applied Thermal Engineering 29 2009 597 600 4 When the system reached steady state for more than 1 h data were taken every 30 s for more than 30 min 2 3 Test condition To compare the performance of refrigerants correctly a fair test condition should be employed For this purpose all tests were conducted with the secondary HTF temperatures fi xed in this study For air conditioning simulation HTF water ethylene glycol mixture in the evaporator and water in the condenser temperatures at the inlet and outlet of the evaporator were set to roughly 26 0 C and 11 0 C respectively while those at the in let and outlet of the condenser were set to roughly 30 0 C and 42 0 C respectively Even though the external condition was the same the resulting saturation temperatures of HCFC22 and R432A in the evaporator and condenser were different roughly 7 C and 45 C due to differing heat transfer characteristics of these fl uids For heat pumping simulation HTF temperatures at the inlet and outlet of the evaporator were set to roughly 10 0 C and 1 0 C respectively while those at the inlet and outlet of the con denser were set to roughly 30 0 C and 39 0 C respectively Un der this condition the saturation temperatures of HCFC22 and R432A and in the evaporator and condenser were roughly 7 C and 41 C respectively In fact for both conditions the HTF temperatures at the outlets of the evaporator and condenser varied a little bit due to the difference in capacity between two refrigerants tested Calibrated pressure transducers of 0 1 FS accuracy coriolis mass fl ow meters of 0 2 accuracy and a dig ital power meter of 0 1 accuracy were used in the measure ments Inthisstudy theuncertaintyintemperature measurement is less than 0 1 C For all tests the superheat at the evaporator exit and subco oling at the condenser exit were kept to be 5 C The amount of charge was adjusted to maintain the same superheat and subco oling under the same external condition Finally as for the lubri cant a conventional mineral oil was used for both R432A and HCFC22 3 Results and discussion Tables 1 and 2 list various measured system parameters such as the coeffi cient of performance COP capacity compressor work pressure ratio discharge temperature and amount of charge for HCFC22 and R432A obtained under air conditioning and heat pumping conditions respectively For each refrigerant tests were performed at least three times and test results agreed within 1 repeatability 3 1 Coeffi cient of performance In refrigeration and air conditioning COP is a measure of en ergy effi ciency for a given device charged with a specifi c refriger ant Hence it is important to examine fi rst of all the COP of R432A against HCFC22 As listed in Tables 1 and 2 the COP of R432A is 8 5 8 7 higher than that of HCFC22 under both condi tions One of the reasons for the improved effi ciency is the decrease in pressure ratio PR across the compressor As listed in Tables 1 and 2 the PR of R432A decreased 9 7 as compared to that of HCFC22 The decreased pressure ratio in turn results in a decrease in compressor work which was also seen in Tables 1 and 2 Test results demonstrate that R432A is a good alternative to replace HCFC22 in air conditioners and heat pumps from the standpoint of energy effi ciency 3 2 Capacity The capacity is as important as COP in refrigeration Tables 1 and 2 show the evaporator cooling capacity Qefor air conditioning and the condenser heating capacity Qcfor heat pumping as well as changes in capacity difference in Qeand difference in Qc of R432A as compared to HCFC22 for a given compressor R432A showed 1 9 6 4 higher capacity under both conditions Especially the capacity difference between R432A and HCFC22 was larger under heat pumping condition This is a good feature considering the inherent problem of heat pumps that the heating capacity de creases as the outdoor temperature decreases Test results indicate that R432A is a good drop in replacement without requiring ma jor changes in compressor In fact resizing and redesigning of com pressors is very costly and the drop in feature of R432A is very advantageous from the viewpoint of manufacturing cost 3 3 Compressor discharge temperatures The lifetime and reliability of the system as well as the stability of the refrigerant and lubricant should be considered when alter native refrigerants are considered These characteristics can be examined indirectly by measuring the compressor discharge tem perature Tdis As listed in Tables 1 and 2 R432A showed 14 1 17 3 C decrease in discharge temperature From this observation it can be safely concluded that R432A would be appropriate from the viewpoint of system reliability and refrigerant stability 3 4 Refrigerant charge Most of the hydrocarbons have smaller density than that of the halocarbons and hence the amount of charge decreases signifi cantly with hydrocarbons 10 As listed in Tables 1 and 2 R432A Table 1 Test results for HCFC22 and R432A under air conditioning condition RefrigerantsCOPDifference in COP Qe W Difference in Qe W W Difference in W PRTdis C Charge g HCFC223 41373410962 9984 71300 R432A3 708 538061 91028 6 22 7070 6650 Table 2 Test results for HCFC22 and R432A under heat pumping condition RefrigerantsCOPDifference in COP Qc W Difference in Qc W W Difference in W PRTdis C Charge g HCFC223 6834729434 2794 11350 R432A4 008 736936 4923 2 13 8676 8650 K J Park et al Applied Thermal Engineering 29 2009 597 600599 showed a decrease in charge of 50 0 51 9 as compared to HCFC22 This will help alleviate further the direct emission of refrigerant which is responsible for the greenhouse warming 4 Conclusions In this study thermodynamic performance of R432A and HCFC22 was measured in a breadboard type heat pump air condi tioner under typical air conditioning and heat pumping conditions Various performance characteristics were measured and following conclusions were drawn 1 The COP of R432A is 8 5 8 7 higher than that of HCFC22 2 The capacity of R432A is 1 9 6 4 higher than that of HCFC22 3 The compressor discharge temperature of R432A is 14 1 17 3 C lower than that of HCFC22 4 The amount of charge for R432A is 50 lower than that of HCFC22 due to its low density 5 R432A is a good long term drop in environmentally friendly alternative refrigerant to replace HCFC22 in residential air conditioners and heat pumps due to its excellent thermody namic and environmental properties Acknowledgements This study was supported by MK Chemical Inc and Inha University References 1 United Nations Environmental Programme Montreal Protocol on Substances that Deplete the Ozone Layer Final act United Nations New York 1987 2 A Cavallini Working fl uids for mechanical refrigeration Int J Refrigeration 19 1996 485 496 3 D Jung Y Song B Park Performance of HCFC22 alternative refrigerants Int J Refrigeration 23 2000 466 474 4 K Park D Jung Performa
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
评论
0/150
提交评论