



全文预览已结束
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
3 Operating elements Barksdale GmbH Dorn Assenheimer Strasse 27 D 61203 Reichelsheim Germany Tel 49 60 35 9 49 0 Fax 49 60 35 9 49 111 and 9 49 113 e mail info barksdale de www barksdale de UDS 3 12 Electrical connection 1 Ub 2 Ub 3 Signal Switch contacts S1S2S3S4 S1S2S3S4 Protective load M4 Analog output Analog GND 0 V 4 20 mA 0 10 V Current supply 18 V DC 30V DC 0 V max RL UB 12 V 20 mA max 10 mA Sensor connection UAS 3 acc DIN 43650 8 digit 14 segment display Cover screws Sign Trend arrows Menu buttons 20 part bargraph Connection UAS 3 optional Pg 13 5 Pressure conn Pg 13 5 Pressure conn 4 x 4 5 Signal Ub Ub 1 2 3 gn bn ws 38 5 Switchpoint display SP1 SP4 Dimensions in mm Operating Instructions Pressure Switch UDS 3 with 4 Relay Outputs and Trip Amplifier UAS 3 1 Product description 2 Starting operations Intended applications The pressure switch trip amplifier is a device to monitor system pressure temperature flow level etc and has four switching outputs and one analog output The pressure switch is only to be installed in systems where the maximum pressure Pmax is not exceeded according to the values on the type label The trip amplifier is only to be connected to input signals according to the values on the type label at the bottom side of the device Attention This device is not designed to be used as the only safety relevant element in pressurized systems according PED 97 23 EC Only assemble or disassemble the device when depressurized The pressure switch should be installed and operated only by authorized personel For wall mounting remove the four front cover screws and the front cover Then fasten the device with four screws to the wall and finally remount the front cover To damp strong vibrations shock mounts must be used Mount the pressure connection G 1 4 female of the UDS 3 to the pressure system with a flexible pipe and tighten with a 45 Nm torque For pressure peaks damping screws must be used UAS 3 Connect the sensor to the 3 pin cube plug at the bottom side of the device The electrical connection supply analog output switching contacts must be carried out according to the connection tables depicted on the top of the device by removing the cover cap and insert the cable through the cable gland PG 13 5 If required additional cable glands can be installed in the cover cap by breaking out the perforated cavities The electrical connection must be carried out in accordance with the VDE 0100 regulations In order to ensure trouble free operation it is essential to connect the protective lead When operating from 230 V AC loads at the switch contacts independent cables must be installed for supply and switches cover cap with two cable screw connections If inductive loads magnets contactors etc are connected to the switch relays suitable protective devices varistors etc must be provided Fixing lugs for M4 screws Item Nr 923 1196 Software version V1 or higher Index C 05 05 2004 Specifications are subject to changes without notice Contact rating max 120 V DC 250 V AC Switching power max 120 W 1250 V AC Switching capacitiy 220 V AC 3 A VDE 0660 T 2 Constant current max 5 A Switching rate max 20 s Analog measuring input By choice Current input 4 20 mA Voltage input 0 10 V DC Resistance input Poti 500 Ohm 100 kOhm in combination with 2 wire circuit pin 2 is not required Plug 3 pin DIN 43650 38 5 43 DisplayErrorCause maxPositive excess of the measuring rangeThe measured value exceeds the max of the range minNegative excess of the measuring rangeThe measured value is lower than the min of the range anaoFailure of the analog outputOutput loop is not closed or short circuited sensSensor failure internal Sensor bridge not in balance might be been overloade dataStored data failure EEProm internal Memory failure progProcessor failure internal Microcontroller failure calCalibration failure internal Calibration values are wrong 4 Operation After the unit is switched on the unit starts an automatic self test The device is menu operated and configured by the three keys on the front With the M key mode you change between the operation indicating level to the dialog values and the adjusted actual values With the keys up and down you change between the dialog values in the menu or change the values functions in the menus A change of any configuration starts always with the M Mode and indicated by the flashing cursor After a change has been made the M mode key must be pressed to confirm each configuration to set numbers each digit has to be confirmed with the M Mode before adjusting the next one By confirming the last digit the new configuration will be stored in the memory Pushing the down key at the end of the sub menu the software will switch automatically to the main menu For a quick termination of programming you can change into the measuring mode from any level in the menu by pressing the M key for 5 seconds If the dialog is not continued within two minutes the device automatically returns to the measuring mode without accepting the new values see also List of functions 5 Key lock Activating the up and down keys together for more than 5 seconds will block any changings in all menues shown by LOCK in the display In this mode all configuration values can be checked only but not changed Repeating this action will unlock the configuration menu and shown by UNLK in the display 6 Error handling The internal self check software will monitor the proper functioning of the unit When any of the following failures will occur the flashing display will indicate the following text List of functions Main MenuSub MenuValueDescription Measuring Display of the actually measured value modeand the measuring unit MENUDisplay keylock UNLKNo keylock all parameters can be adjusted LOCKKeylock active all parameters visibal but can not be changed SP 1 SP 4Switchpoint menu SP1 SP4 MODESTNDStandard evaluation rising falling WINDWindow technology ERROError output ON Switch on value for SP1 SP4 if the ON value is smaller than the OFF value the switch evaluatiuon is falling OFF Switch off value SP1 SP4 LEVInversion of the switching output SP1 SP4 HLFSHigh level fail safe Normally Open function LLFSLow level fail save Normally Closed function DEL0 0s 9 9 sSwitch on switch off delay for SP1 SP2 in seconds ANOPAnalog output menu ANOPONAnalog output in operation OFFAnalog output switched off AOZS Scale the analog output start value e g 0 bar 4mA AOFSScale the analog output end value e g 400bar 20mA DISPDisplay menu UNITbarAdjustment of the measuring unit the recalculation to the new onlyPSIunit value is done automatically UDS3 MPa DAMP0 0s 9 9 sDamping of the displayed measuring value in seconds OFFS Measuring value Offset means shifting the display range CUT Cut Off means signal surpression within the cut off range BGZS Scale the bargraph start
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 制造业生产流程优化及效率提升方案
- 社交媒体对时尚设计行业知识产权的影响研究-洞察及研究
- 中华经典古训文化普及手册
- 天线阵列与物联网融合研究-洞察及研究
- 国企员工岗位职责与考核细则示范文本
- 氮磷去除技术在湖泊治理中的应用-洞察及研究
- 特殊需求学生教育机会的不平等-洞察及研究
- 2025福建龙岩市上杭县总医院引进医学类台湾人才1人模拟试卷及答案详解(夺冠)
- 圣诞节联欢晚会英文主持稿
- 硕士研究生电子技术考试科目大纲
- 公司工程数量管理办法
- 宇宙中的地球 1.3地球的历史(第1课时)课件
- 支部委员会委员选票一
- 锅炉安装改造维修施工工艺标准
- 如何书写个案护理报告
- 一线医务人员登记表(模板)
- GB/T 1591-2018低合金高强度结构钢
- 战略销售蓝表中文版
- 2021年四年级数学上册二两三位数除以两位数整理与练习课件苏教版
- 人体解剖学01绪论课件
- 第3节金属的塑性加工
评论
0/150
提交评论