




已阅读5页,还剩15页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
China JiangsuTaicang Instrument Factory Taicang Computer Application Instrument FactoryProduct SpecimenProduct ManualSXY2 series liquid level monitorSWJ series electrode water level meterBrief IntroductionTaicang Instrument Factory and Taicang Computer Application Instrument Factory covers an area of 5640 sqm and their floor area is 3000 sqm. There are 144 staff and workers among which 8 professional inspectors and 15 engineers, assistant engineers and economists. The factories are capable of producing in batches the complete set of electric contact water level meters which obtain the title of famous brand product of Suzhou City. The factories have been praised as the “bona fide” unit successively for ten years.Established in 1977, Taicang Instrument Factory mianly produces instruments, valves, electrodes and high pressure vessels etc. All these products sell well to about 800 users in 28 provinces, cities and autonomous regions and the products are also supplied to a considerable number of boiler manufacturers. The products also enjoy exportation to southeast Asian regions. Now they have developed J641Y-64 pneumatic fast shutoff valve, J61Y-P55 170V high pressure cutoff valve, pressure vessel, B43H pipe level meter and DK,-3 single and double polarity switch etc.Taicang Factory is equipped with processing machines as lathes, grinders, millers, drillers, cold processing and welding equipment. It also has electronic measuring instruments, transistor characteristice display instruments, BT-3 frequency characteristics display instrument, UJ-37 electronic display instruments, BT-3 frequency characteristics display instruments, UJ-37 electronic potential difference gauges and standard resistor box etc.Taicang Instrument Factory and Taicang Computer Application Instrument Factory is designated as the SWJ series and SXY2S series electrode two-colour water level meters producer by The Ministry Of Machinery And Electronics Industry.1. ApplicationSXY2S series liguid level monitor is a new kind of electrode liquidometer, which is suitable for measuring and controlling the liquid level in boiler drum, high and low pressure heater, degasifier, evaporator, start-up separator of once-through boiler, water tank etc. It is also used for measuring and controlling the level of other electric conductive liquid, but not for the combustibe, burstable or corrosive liquid.For meeting the demand of increased water treatment technology, the instrument could be used in the situation of water resistance 0500K, the function of adjusting water resistance arbitrarily is designed in the instrument for consumers using in situ.2. Technical parameters1. Voltage requirement: 220V(-15% +10%)2. Supply time of direct current(D.C)by storage battery in the instrument:4hours3. Operating temperature: -10 +454. Operating humidity:85%5. Suitable water resistance:0-500K6. Down lead length from contact to indicator instrument:200m7. Capacity of output contact of relay: maximum limited two sets in normally open and normally shut 220V 3A, minimum limited two sets in normally open and normally shut 220V 3A(the instrument with the relay of maximum limited three sets and minimum limited two sets could be provided according the special requiment of user).8. Hole in a instrument panel for mounting:152+1mm76+1mm9. Dimensions:80mm160mm300mm(WHL),special type:160mm160mm300mm10. Power consumption:5W11. Weight: about 2.8Kg 3. NomenclatureSWY2S-XXX-XXX-XProduct type-scale type-measure cylinder-erect mode (function)The scale type look up table 6, The measure cylinder look up table 2, erect mode: Z-vertical, H-horizontal ,C-self-provided power source4. Characteristics1.SXY2S series liquid level monitor consists of measure cylinder, electrode contacts and secondary meter. On the priciple of different conductivity between water and steam in the boiler drum, the change of water level could be transformed into the cgange of resistance, which then be delived to secondary instrument to measure, indicate and control. The multi-polar detection is adopted, i.e, the numbers of electrode contact in measure cylinder is same as the number of indicated point on secondary meter. The most number of electrode contact is 38 (for special type 160mm160mm300mm).This electrode contact liquidometer could be suited to the boiler operation conditions with changed paraments, such as start-up or shut down In such operation conditions, the drum level could be indicated exactly also. Because of the larger sectional area of the measure cylinder, the shrinkage error caused by decrease of water temperature is very little. And the measure cylinder is near to the drum with electric signal transfer from electrode contact to secondary meter , so that the time delay is very short.2.The ultra-pure ceramics electropolars are used as electrode contacts fitted in SXY2S series liquid level monitor, which have excellent characteristic of pressurization, thermostability, insulation and use alternating current as power supply, so that the life of electrode contact could be prolonged effectively, the troble of changing electrode contact frequently could be avoided.3.The integrated circuit with high input resistence and CMOS digital circuit with socket are used in secondary meter,it is very convenient for production and maintenance. The analog display and digital display are used simultaneously as indicator of the instrument,so the up-down situation of the water level could be indicated very sensitively. A set of colour changeable luminant diodes matched with a standard scale-meter are used as analogy display, red as steam while green as water. While a three digits LED charactron matched with a sign indicator is used as digit display (four digits charactron is used in some instruments).4.The SXY2S series liquid level monitor is provided with the function of acousto-optic alarm when the water level is beyond the limit. The alarm point could be setted arbitrarily according the users demand (jumper wire connection is adopted), and each two sets of relays output control contacts as higher limit and lower limit respectively are provided for extemal connection. To the special demand, the output control contacts of three sets as higher limit and two sets as lower limit (or two sets as higher limit and three sets as lower limit) could be provided also. For eliminating the effect of false level on the alarm interlock action caused by getting water drop on the electrode, the judge fuction of alarm logical control is designed specially to avoid alarm of false level effectively. Besides, for avoiding the different kinds of interference caused by all sorts of thermal instrument and equipmetn in control room.as well as long distance transfer of signals, the higher interference protection measure is adapted in design of the present series instrument.5.In order to ensure boiler operation normally, when power supply suddenly stop the water level could be detected and alarmed still, the power self-supplying fuction is set up to supply power more than 4 hours after power accident by butteries in the instrument.6.The quick detecting button is fitted on the panel of instrument for checking the troble place of secondary meter conveniently.7.The blowdown button is also fitted on the instrument panel for avoiding malfunction and misalarm caused by attracting the control contacts of two sets of lower limit relay when measure cylinder doing blow-down.5.Structure and Function1.Measure cylinder Its structure is shown in Fig.1.Centerline spacing of vapour-liquid commumicating tubevapour tubeelectrode standcylinder bodyelectrodeliqid tubeblowdown tube Fig1 Structure of measure cylinderThe functions of every parts are shown in table 1.Table 1 Function of every parts of measure cylinderNonamefunction1vapour tubelink with the vapour space of drum2liquid tubelink with the liquid space of drum3blowdown tubeblowdown pipe for clearing cylinder4cylinder body5electrode standused for fitting electrode6electrodeused for checking liquid-vapour levelnote: The centerline spacing of vapour-liquid communicating tube is decided according to the demand of user.The specifications of measure cylinder are shown in table 2.Table 2 Specifications of measure cylinderNo number of measure cylinderpressuretemperaturecenterline spacing of vapour-liquid communicating pipe1016.3MPa250decided by user20216.0MPa350decided by user30322.0MPa380decided by usermanufacture standard of measure cylinder:According to the National Machinery Trode StandardTechnical Requirement for Electrode Liquidometer of BoilerJB/T6691-932.Electrode using ultra-pure ceramics electropolars working temperature37.2pressurization21.56Mpainsulating property500M The specifications of electrode are shown in table 3.Table 3 Specifications of electrodetypedimensionsfitting type with cylindernoteDJM1615-115M161.5115external threadinsulation typeDJM1615-87M161.587external threadno insulation typeDJY1712-1151712115press-in fitinsulation typeDJY1712-87171287press-in fitno insulation type3.Secondary meter1)front panelIt is shown in Fig.2.digit displayheight scale of liqid levelbuzzer+250+150+100+ 75+ 50+ 30+ 15 0- 15- 30- 50- 75-100-150-250-200+200alarm lamp of maximum limitmax limithigher limitblow downlower limitmin limitalarm lamp of higher limitindicator lamp of work and blow downalarm lamp of lower limitalarm lamp of minimum limitmufflealarmdetecting buttonBlow down buttonmuffle buttonworkworkBlow down detectliquid level displayFig 2 Front panelThe functions of every part of front panel are shown in table 4.Table 4 Functions of every part of front panelnamefunctionliquid level displayconsist of a set of colour changeable luminant diodes height scale of liquid levelconsist of a set of digit and scale line, corresponding to the liquid level display, indicate the real height of liquid level.sound alarmergive alarm sound when liquid level higher or lower then the alarm pointalarm lamp of maximum limitthe red lamp gives flash signal when liquid level reaches the maximum limitalarm lamp of higher limitthe yellow lamp gives flash signal when liquid level reaches the higher limitindicator lamp of work and blow downthe green lamp lights when instrument works, the red lamp lights when blow downalarm lamp of lower limitthe yellow lamp gives flash signal when liquid level reaches the lower limit.alarm lamp of minimum limitthe red lamp gives flash signal when liquid level reaches the minimum limit.muffle buttonpress the muffle button on the “muffle”, the alarm sound eliminates.Blow down buttonpress the blow down button on the “blow down”, the red lamp of blow down lights, meanwhile cut the output relays of lower limit and minimum limit.detecting buttonpress the detecting button on the “detect”, the all green lamps of liquid level indication lights, meanwhile cut the output relays of higher limit and maximum limit.2) rear panelIt is shown in Fig.3.The functions of every part of rear panel are shown in table 5.RS232-15 pinsfuse sockettoggl switchRS232-25 pins sockettwo fastening screwsFig.3 Rear panelTable 5 Functions of every part of rear panelNonameFunction1RS232-15 core socketconnecting to power source and the output contacts of relay2RS232-25 core socketconnecting to electrode contacts of measure cylinder3fuse and fuse socketovercurrent protection of power source4toggle switchpower switch5fastening screwfastening the inner parts of instrument6 Operating principle1.Operating principle of systemSXY2S sieres liquid level monitor system consists of measure cylinder electrods and secondary meter. Its functional schematic diagram is shown in Fig4.measured cylindersteam-water commuicating valve relay outputelectrodSecondary metermeasured vessellevel displaywireblow down valveFig 4. Functional schematic diagram of systemBecause the conductivity of water is very different from that of steam the function of measure cylinder is to get the signal of resistances changing of electrode as water level changes. Owing to the smaller resistivity of liquid medium, the current passed through electrodes is large when a electric voltage put on between electrodes. On the contrary, the current passed through electrldes is small as the electrodes are above the liquid level. The current difference of such two conditions is very large. It could be as a signal sending to secondary meter. After amplifying, it could be displaied and could control output. So the long-distance supervisory control is realized.2.Operating principle of secondary meter Its functional schematic diagram is shown in Fig.5. The electricity schematic diagram is shown in attached figure(SXY2S-19c as example)(1)detect and simulate display unitSince every electrode contact is corresponding to a route of detect and simulate display unit, so there are 19 electrode contacts corresponding to 19 routes of detect and simulate display unit. Every route of detect and simulate display unit consists of same detecting element, display drivecircuit and colour-changeable luminant diode, shown in Fig.6.digit display umitdiode encoderFig5 Functional schematic diogram of secondary meter圖6 檢測和模擬顯示電路圖 Fig.6 Detect and simulate display circuitWhen the electrode contact is not under liquid, owing to large resistivity of steam, the current passed through the electrode contact put from alternating signal power source is small which cuts the detecting biode D1 off. The integrated circuit puts out negative voltage(about 2V). So colour-changeable luminant biode back conducts and displays red.When the electrode contact is under liquid, owing to small resistivity of liquid, the current passed through the electrode contact put from alternating signal power source is large, which connects the detecting biode D1 on. The integrated circuit puts out positive voltage(about +3V). So colour-changeable luminant biode forward conducts and displays green.The output voltage signal of integrated circuit is sent to digital display circuit and logical control alarm circuit simultaneously, which numbers are B1-B19 respectively from low to high.(2) digital display circuitIts functional schematic diagram is shown in Fig.5. B1-B19 are the input signals of digital display circuit, the higher electrical level is +3V, the lower one is 2V: Whe the hight of liquid level changes, the electrical level of B1-B19 signal changes responsively. First the B1-B19 signalprior encode through three 4532 circuits, then address latch by three 4099 circuits, decoding by biode matrix, last the figure of the liquid level is displaied through four 45H circuits, which drives one digit symbolic identifier and three digits caractron, This figure shoule be consisitent with the value indicated on the scale of liquid level.(3) logical control alarm circuitIts functional schematic diagram is shown in Fig.5. B1-B19 are the input signals of logical control circuit, which could be connected with jumper wire according to the different demand of users conditions.The higher limit logical control circuit consists of AND gate 1,2,3, which four input terminals are H1,H2,H3,H4 in order. When the input signals of logical control circuit connected from H1,H2 are high electrical level, i.e. corresponding electrode contacts are under liquid, the output s1 becomeshigh electrical level. So the alarm lamp(yellow) of higher limit is lighted, the buzzer issues alarming sound. Meanwhile the relay J3 of higher limit is acted by the control of integrated circuit. If one signal of H1 and H2 is low electrical level. The SI is low electrical level still, the alarm of light and sound, as well as relay are not acted. So it is effective to prevent wrong alarm of false water level.When the signals of H1,H2,H3 are all high elevtrical level, the output S2 becomes high electrical level. So the alarm lamp (red) of maximum limit 1 is lighted, the buzzer issues alarming sound. Meanwhile the relay J4 of maximum limit 1 is acted by the control of integrated circuit.Similarly, when the signals of H1,H2,H3,H4 are all high electrical level, the output S3 becomes high electrical level. So the alarm lamp (red) of maximum limit 2 is lighted, the buzzer issues alarming sound. Meanwhile the relay J5 of maximum limit 2 is acted by the control of integrated circuit.The lower limit logical control circuit consists of AND gate 4.5, which four input terminals are L1,L2,L3,L4 in order. When one signal of L4,L3 is low electrical level, I,e. one of the two corresponding electrode contacts is above liquid level, the output X2 becomes low electrical level. This means that the liquid level decreases below the alarm point of lower limit. So the alarm lamp (yellow) of lower limit is lighted, the buzzer issues alarming sound. Meanwhile the relay J2 of lower limit is acted by the control of integrated cireuit.Similarly, when one signal of L2,L1 is low electrical level, the output X1 becomes low electrical level. This means that the liquid level decreases below the alarm point of minimum limit. So the alarm lamp(
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
评论
0/150
提交评论