



全文预览已结束
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1 Monitoring technique Voltage relay BA 9054 MK 9054 varimeter According to IEC 255 VDE 0435 part 303 One model for AC and DC voltages Measuring ranges from 15 mV to 500 V BA 9054 optionally with galvanic separated DC auxiliary supply MK 9054 optionally with remote potentiometer Open circuit operation Optionally closed circuit operation High overload possible Permissible frequency range of the measuring voltage 50 400 Hz Optionally with time delay LED indicators for operation and contact position Width MK 9054 22 5 mm Width BA 9054 45 mm Function diagram MK 9054BA 9054 Approvals and marking Function The relays measure the arithmetic mean value of the rectified measuring voltage The AC units are adjusted to the r m s value They have settings for response value and hysteresis The units work as overvoltage relays but can also be used for undervoltage detection The hysteresis is dependent on the response value The BA 9054 is optionally available with time delay On the MK 9054 a fixed time delay can be activated by linking terminals X3 X4 0221541 Applications Monitoring voltage in AC or DC systems BA 9054 Circuit diagrams Indicators upper LED on when auxiliary supply connected lower LED on when output relay acitvated MK 9054 see Variants USAUSA Canada Technical data Input Measuringinternalmax permissible range1 resistancecontinuous voltage 15 150 mV40kW6V 50 500 mV270kW20V 0 5 5V330kW200V 5 50V2 MW500V 2 25 250V2 MW500V 2 50 500V2 MW500V 2 1 DC or AC voltage 50 400 Hz 2 at Overvoltage category II 600 V Measuringinternalmax permissible range1 resistancecontinuous voltage 15 150 mV40kW100V 50 500 mV270kW250V 0 5 5V500kW300V 1 10V1 MW300V 5 50V2 MW600V2 25 250V2 MW600V2 50 500V2 MW600V2 1 DC or AC voltage 50 60 Hz 2 at Overvoltage category II 600 V BA 9054 MK 9054 2 Technical data Degree of protection Housing IP 40EN 60 529 Terminals IP 20EN 60 529 Housing Thermoplastic with V0 behaviour according to UL subject 94 Vibration resistance Amplitude 0 35 mm frequency 10 55 HzEN 60 068 2 6 Climate resistance BA 9054 40 060 04EN 60 068 1 MK 9054 20 060 04EN 60 068 1 Terminal designation EN 50 005 Wire connection BA 9054 2 x 2 5 mm2 solid or 2 x 1 5 mm2 stranded wire with sleeve DIN 46 228 1 2 3 4 MK 9054 2 x 1 5 mm2 solid or 2 x 1 mm2 stranded wire with sleeve DIN 46 228 1 2 3 4 Wire fixing Flat terminals with self lifting clamping pieceEN 60 999 Mounting DIN railEN 50 022 Weight BA 9054 270 g MK 9054 160 g Dimensions Width x height x depth BA 9054 45 x 73 x 132 mm MK 9054 22 5 x 82 x 102 mm Technical data Please note To avoid measuring mistakes on units with mV input the input must always be terminated In addition screened wires should be used Measuring principle arithmetic mean value Adjustment DC units are adjusted to the DC voltage mean value AC units to the r m s value It ist possible to use AC units to measure DC and the other way round The scaling is the shifted by the factor Ur m s 1 1 U U 0 9 Ur m s Temperature influence 0 05 K Setting ranges Setting Response value infinite variable 0 1 UN 1 UN relative scale Hysteresis infinite variable 0 5 0 98 of setting value Accuracy 5 Time delay tv BA 9054 infinite variable from 0 5 5 s only with BA 9054 010 BA 9054 011 BA 9054 012 BA 9054 013 other values on request MK 9054 approx 1 s or 5 s fixed The units are delivered with a bridge between terminals X3 X4 If this bridge is removed the time delay is inactive Auxiliary circuit Auxiliary voltage UH BA 9054 AC 24 42 110 127 230 V AC DC 24 60 V AC DC 110 230 V MK 9054 AC 24 42 110 127 230 V Voltage range 0 8 1 1 UH Nominal consumption BA 9054 approx 2 5 VA MK 9054 approx 2 0 VA Nominal frequency 50 60 Hz Frequency range 5 Output Contacts BA 9054 12 2 changeover contacts MK 9054 1 changeover contact Thermal current Ith 5 A Switching capacity to AC 15 NO contact MK9054 3 A AC 230 VEN 60 947 5 1 NC contact MK 9054 1 A AC 230 VEN 60 947 5 1 Electrical lifeEN 60 947 5 1 to AC 15 at 3 A AC 230 V 105 switching cycles Short circuit strength max fuse rating 6 AgLEN 60 947 5 1 Mechanical life 30 x 106 switching cycles General data Operating mode Continuous operation Temperature range BA 9054 40 60 C MK 9054 20 60 C Clearance and creepage distances overvoltage category contamination level 4 kV 2DIN VDE 0110 1 04 97 EMC Electrostatic discharge 8 kV air EN 61 000 4 2 HF irradiation 10 V mEN 61 000 4 3 Fast transients 4 kVEN 61 000 4 4 Surge voltages between wires for power supply 2 kVEN 61 000 4 5 between wire and ground 4 kVEN 61 000 4 5 Interference suppression Limit value class BEN 55 011 BA 9054 AC 25 250 A AC 230 V Article number 0029191 Measuring range AC 25 250 V Auxiliary voltage UH AC 230 V Without time delay Open circuit operation Width 45 mm MK 9054 AC 25 250 V AC 230 V 1 s Article number 0026686stock item Measuring range AC 25 250 V Auxiliary voltage UH AC 230 V Time delay 1 s Open circuit operation Width 22 5 mm Standard types Variants BA 9054 12 61 with UL approval BA 9054 001 closed circuit operation BA 9054 010 open circuit operation with time delay at Uan BA 9054 011 closed circuit operation with time delay at Uan BA 9054 012 closed circuit operation with time delay at Uab BA 9054 013 open circuit operation with time delay at Uoff The units BA MK 9054 012 and BA MK 9054 013 can be used as undervoltage relays The delay starts when the inputs signal drops below the setting value MK 9054 61 with UL approval Canada USA MK 9054 011 closed circuit operation MK 9054 012 closed circuit operation MK 9054 013 open circuit operation MK 9054 1 connection of remote potentiometer with 470 kW 3 Characteristics Switching delay The characteristic shows the switching delay depending on the values of Xon Xoff when switching the current on or off A slow current change reduces the delay F U applied U setting BA 9054 MK 9054 Se
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 中国热水器排气筒行业市场调查研究及发展战略规划报告
- 2025年海底观测市场分析报告
- 中国特种车改装行业市场全景监测及投资战略咨询报告
- 2025年唇膜市场调查报告
- 中国海鲜餐饮行业市场全景评估及发展战略规划报告
- 2024-2030年中国大理石板材行业市场全景监测及投资前景展望报告
- 中国高反应性聚异丁烯(HR-PIB)行业市场调查报告
- 中国入户门行业市场全景评估及投资方向研究报告
- 中国食用碱块行业市场发展前景及发展趋势与投资战略研究报告(2024-2030)
- 小学第29个爱国卫生月活动总结
- 电梯安装技术交底完整版
- 氧化铝溶出机组热试方案
- 小学阅读理解提分公开课课件
- esd防静电手册20.20标准
- 教育政策与法规课件
- 养老护理员职业道德27张课件
- 少儿美术课件-《长颈鹿不会跳舞》
- 人教版五年级数学下册单元及期中期末测试卷含答案(共16套)
- GB∕T 17989.1-2020 控制图 第1部分:通用指南
- EN485.32003铝及铝合金薄板、带材和厚板第三部分(译文)
- 商混企业整合方案
评论
0/150
提交评论