光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S36风机温度 0 光缆盘号001光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号A3接头塔号A3纤芯衰减测试测试线路长度0. 844km方向升压站至S36风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3218W0.350.312OR0.350.3219R0.350.303G0.350.3120N0.350.314BR0.350.3021Y0.350.325GR0.350.3122V0.350.316W0.350.3223P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.302610V0.350.312711P0.350.322812AQ0.350.312913B0.350.303014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3034测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S24风机温度 0 光缆盘号001光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号A18接头塔号A18纤芯衰减测试测试线路长度 0.524 km方向S24至S25风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3218W0.350.312OR0.350.3219R0.350.303G0.350.3120N0.350.314BR0.350.3021Y0.350.315GR0.350.3122V0.350.316W0.350.3223P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.302610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S25风机温度 0 光缆盘号001光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号A17接头塔号A17纤芯衰减测试测试线路长度1.125 km方向S25至S26风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3018W0.350.302OR0.350.3119R0.350.313G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.302610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S26风机温度 0 光缆盘号001光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号A15接头塔号A15纤芯衰减测试测试线路长度1.102 km方向S26至S29风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3018W0.350.302OR0.350.3119R0.350.313G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.302610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S27风机温度 0 光缆盘号004光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号AB4接头塔号AB4纤芯衰减测试测试线路长度0.648 km方向S27至S28风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3018W0.350.302OR0.350.3119R0.350.313G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.302610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S28风机温度 0 光缆盘号004光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号AB6接头塔号AB6纤芯衰减测试测试线路长度1.242 km方向S28至S25风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3018W0.350.302OR0.350.3119R0.350.313G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.302610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S29风机温度 0 光缆盘号002光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号AB6接头塔号AB6纤芯衰减测试测试线路长度 0.675 km方向S29至S26风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3018W0.350.302OR0.350.3119R0.350.313G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.302610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S30风机温度 0 光缆盘号002光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号A11接头塔号A11纤芯衰减测试测试线路长度 0.685 km方向S29至S30风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3018W0.350.302OR0.350.3119R0.350.313G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.302610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S31风机温度 0 光缆盘号001光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号A9接头塔号A9纤芯衰减测试测试线路长度0.665 km方向S30至S31风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3018W0.350.302OR0.350.3119R0.350.313G0.350.3120N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.302610V0.350.312711P0.350.312812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S38风机温度 0 光缆盘号002光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号AA6接头塔号AA6纤芯衰减测试测试线路长度 2.234 km方向S38至S36风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3118W0.350.302OR0.350.3119R0.350.313G0.350.3120N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.302610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S39风机温度 0 光缆盘号001光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号AA8接头塔号AA8纤芯衰减测试测试线路长度 0.952 km方向S38至S39风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3118W0.350.312OR0.350.3119R0.350.313G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.312610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S40风机温度 0 光缆盘号002光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号B11接头塔号B11纤芯衰减测试测试线路长度 1.436 km方向S40至S44风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3218W0.350.322OR0.350.3119R0.350.313G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.327R0.350.3124AQ0.350.318N0.350.31259Y0.350.302610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S41风机温度 0 光缆盘号002光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号B12接头塔号B12纤芯衰减测试测试线路长度 0.452 km方向S40至S41风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3218W0.350.322OR0.350.3119R0.350.323G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.312610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3234测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S44风机温度 0 光缆盘号003光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号BAA4接头塔号BAA4纤芯衰减测试测试线路长度 0.432 km方向S45至S44风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3118W0.350.312OR0.350.3119R0.350.313G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.312610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3034测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S45风机温度 0 光缆盘号002光纤芯数24测试波长1310 nm测试项目开盘测试标称长度4200 m外层损伤无光纤封头完好实测长度4200 m线盘质量完好无损坏接头衰减测试接头桩号BAA2接头塔号BAA2纤芯衰减测试测试线路长度 0.874 km方向S45至S29风机纤芯序号纤芯色别纤芯衰减(db/km)纤芯序号纤芯色别纤芯衰减(db/km)允许值实测值允许值实测值1B0.350.3218W0.350.312OR0.350.3119R0.350.313G0.350.3220N0.350.324BR0.350.3121Y0.350.315GR0.350.3222V0.350.326W0.350.3123P0.350.307R0.350.3124AQ0.350.318N0.350.31259Y0.350.302610V0.350.312711P0.350.322812AQ0.350.312913B0.350.323014OR0.350.313115G0.350.323216BR0.350.313317GR0.350.3134测试仪器:采用信维牌OTDR(光时域反射仪),具体型号为S20。测试结论:经测试光缆熔接损耗值符合图纸设计及规范要求,可以投入运行。试验单位(盖章): 审核人:年 月 日光缆测试报告工程名称: 生产厂家 测试日期2018年01月20日测试地点S46风机温度 0 光缆盘号003光纤芯数24测试波长1310
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年岸电系统行业当前发展趋势与投资机遇洞察报告
- 2025年应急产业行业当前发展现状及增长策略研究报告
- 收纳培训资料课件
- 收入确认五步法培训课件
- 2025年部编新版语文七年级上册第五单元复习课教案
- 2025年药品检查员培训试题及答案(GSP、GMP试题)
- 撞车后安全知识培训内容课件
- 2025年注册安全工程师考试真题(含答案)
- 2025会计专业技术人员继续教育考试试题和答案
- 摘苹果课件教学课件
- 医疗收费培训课件
- 通风设施构筑工安全知识题库
- 三福门店日常管理制度
- 公司叉车维修管理制度
- 2025年广东高考物理试卷真题及答案详解(精校打印版)
- 新肇地区葡萄花油层构造脊发育特征及其对油气分布的控制作用
- 二下快乐读书吧《愿望的实现》分享课课件
- 中医刮痧拔罐培训课件
- 简约美缝施工合同协议书
- 湖南省永州市祁阳市2025年中考模拟道德与法治仿真试卷(三)(含答案)
- 2025年纸杯机行业市场调研报告
评论
0/150
提交评论